====== Bicycle, electric (<25 km/h), NMC battery, 2020 — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:bicycle_electric_lt_25_km_h_nmc_battery_2020__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Bicycle, electric (<25 km/h), NMC battery, 2020 [CH], per 1 p. EF v3.1 climate change 173.5 kg CO2 eq (Monte Carlo 95 % interval 168.3–208). Main contributors: Electric bicycle production, without battery and motor 38 %; Battery cell, NMC-622 29 %; Electric motor, electric vehicle, at plant 7 %; Charging station, 500W 6 %; Battery BoP 6 %; Disposal, electric bicycle 4 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Bicycle, electric (<25 km/h), NMC battery, 2020 | | Dataset UUID / graph id | ''%%01856e75-9542-3c4f-bc37-fa1045038ad2%%'' / ''%%activity:bicycle_electric_lt_25_km_h_nmc_battery_2020__ch%%'' | | Reference product, unit | Bicycle, electric (<25 km/h), NMC battery, 2020, 1 p | | Location | CH | | Time period | 2020-01/2020-12 | | Category | transport systems / road\Transformation\Infrastructure | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Power: 0.25 kW. Lifetime: 20000 km. Annual kilometers: 2000 km. Number of passengers: 1. Curb mass: 23.1 kg. Lightweighting of glider: 0%. Emission standard: None. Service visits throughout lifetime: 1.3. Range: 58 km. Battery capacity: 0.5 kWh. Available battery capacity: 0.4 kWh. Battery mass: 3.1 kg. Battery replacement throughout lifetime: 1. Fuel tank capacity: 0 kWh. Fuel mass: 0 kg. Origin of manufacture: China. Shipping distance: 15900 km. Lorry distribution distance: 1000 km. Source: Sacchi R., Bauer C. Life cycle inventories for on-road vehicles. Paul Scherrer Institut, 2023. DOI: 10.5281/zenodo.5156043. UUID: 01856e75-9542-3c4f-bc37-fa1045038ad2 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Bicycle, electric (<25 km/h), NMC battery, 2020 (CH). All results are given per unit of the reference flow. ==== System boundary ==== — ==== Technology ==== Power: 0.25 kW. Lifetime: 20000 km. Annual kilometers: 2000 km. Number of passengers: 1. Curb mass: 23.1 kg. Lightweighting of glider: 0%. Emission standard: None. Service visits throughout lifetime: 1.3. Range: 58 km. Battery capacity: 0.5 kWh. Available battery capacity: 0.4 kWh. Battery mass: 3.1 kg. Battery replacement throughout lifetime: 1. Fuel tank capacity: 0 kWh. Fuel mass: 0 kg. Origin of manufacture: China. Shipping distance: 15900 km. Lorry distribution distance: 1000 km. Source: Sacchi R., Bauer C. Life cycle inventories for on-road vehicles. Paul Scherrer Institut, 2023. DOI: 10.5281/zenodo.5156043 ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electric bicycle production, without battery and motor | technosphere | RER | 0.941 | p | lognormal, GSD² 1.09 | (2,3,2,1,1,3) | 37.7 | ████████ | | | Battery cell, NMC-622 | technosphere | GLO | 5 | kg | lognormal, GSD² 1.09 | (2,3,2,1,1,3) | 28.9 | ██████ | | | Electric motor, electric vehicle, at plant | technosphere | RER | 4 | kg | lognormal, GSD² 1.09 | (2,3,2,1,1,3) | 6.6 | █ | | | Charging station, 500W | technosphere | GLO | 1 | p | lognormal, GSD² 1.09 | (2,3,2,1,1,3) | 6.3 | █ | | | Battery BoP | technosphere | GLO | 1.5 | kg | lognormal, GSD² 1.09 | (2,3,2,1,1,3) | 5.7 | █ | | | Disposal, electric bicycle | technosphere | CH | 0.667 | p | lognormal, GSD² 1.09 | (2,3,2,1,1,3) | 4.4 | █ | | | Transport, transoceanic container ship | technosphere | OCE | 370 | tkm | lognormal, GSD² 1.09 | (2,3,2,1,1,3) | 3.4 | █ | | | Transport, freight, lorry, 16t-32t gross weight, fleet average | technosphere | RER | 23.3 | tkm | lognormal, GSD² 1.09 | (2,3,2,1,1,3) | 3.0 | █ | | | Disposal, Li-ions batteries, mixed technology | technosphere | GLO | 6.5 | kg | lognormal, GSD² 1.09 | (2,3,2,1,1,3) | 2.9 | █ | | | Disposal, electric bicycle | technosphere | CH | 0.167 | p | lognormal, GSD² 1.09 | (2,3,2,1,1,3) | 1.1 | · | | | Glider lightweighting | technosphere | GLO | 0 | kg | none declared: tdc-doc default ±50 % | — | 0.0 | · | | ==== Data quality ==== 10 of 11 direct exchanges carry a declared pedigree, 10 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.0 · completeness 3.0 · temporal 2.0 · geographical 1.0 · technological 1.0 · sample size 3.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Romain Sacchi (PSI); data entry: Julien McTighe (INFRAS); validation (proof reading): Brian Cox (INFRAS) | | time period comment | Technology and vehicle lightweighting factors match manufacture year of 2020 | ==== Data gaps, proxies and assumptions ==== ^ Item ^ Class ^ Value used ^ Reason ^ Effect ^ | 1 exchange(s) without declared uncertainty | uncertainty | fixed in the Monte Carlo | the publisher declares no distribution | ±50 % in the sensitivity check (Section 6.3) | ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **2.887** | 2.177 | 4.532 | 1.45 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.4782** | 0.3075 | 1.183 | 2.01 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **172.9** | 167.7 | 207 | 1.12 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.1176** | 0.09532 | 0.1753 | 1.38 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **173.5** | 168.3 | 208 | 1.12 | | EF-particulate Matter | Impact on human health | disease incidence | **9.367e-06** | 8.941e-06 | 1.340e-05 | 1.22 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1444** | 1292 | 2435 | 1.4 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **31.26** | 28.97 | 50.97 | 1.4 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1475** | 1328 | 2476 | 1.4 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **0.3904** | 0.325 | 0.597 | 1.35 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **0.3381** | 0.2179 | 2.053 | 3.23 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **2.257** | 2.007 | 3.114 | 1.25 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.910e-07** | 1.580e-07 | 5.619e-07 | 1.89 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **6.068e-08** | 5.380e-08 | 9.192e-08 | 1.32 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.517e-07** | 2.258e-07 | 6.327e-07 | 1.68 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.383e-05** | 9.854e-06 | 4.314e-05 | 2.14 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **9.852e-07** | 6.707e-07 | 1.791e-06 | 1.69 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.482e-05** | 1.087e-05 | 4.403e-05 | 2.07 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **51.78** | 18.7 | 316.1 | 4.36 | | Land use | Soil quality index | pt (soil quality index) | **896.3** | 870.7 | 1366 | 1.25 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **4.676e-06** | 4.376e-06 | 6.744e-06 | 1.25 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **0.8711** | 0.8023 | 1.167 | 1.21 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **2418** | 2292 | 3314 | 1.2 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.007044** | 0.006291 | 0.009114 | 1.21 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **103.9** | -6.343e+04 | 3.261e+04 | — | Climate change 173.5 kg CO2 eq per p. Main contributors: Electric bicycle production, without battery and motor 38 %; Battery cell, NMC-622 29 %; Electric motor, electric vehicle, at plant 7 %; Charging station, 500W 6 %; Battery BoP 6 %; Disposal, electric bicycle 4 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electric bicycle production, without battery and motor 38 %; Battery cell, NMC-622 29 %; Electric motor, electric vehicle, at plant 7 %; Charging station, 500W 6 %; Battery BoP 6 %; Disposal, electric bicycle 4 %. Most sensitive exchanges (Section 6.3): Electric bicycle production, without battery and motor [RER] (-3.2 / +3.5 %); Battery cell, NMC-622 [GLO] (-2.4 / +2.7 %); Electric motor, electric vehicle, at plant [RER] (-0.6 / +0.6 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 2.887 | 3.006 | 0.960 | | Climate change-Biogenic | 0.4782 | 0.4782 | 1.000 | | Climate change-Fossil | 172.9 | 172.9 | 1.000 | | Climate change-Land use and land use change | 0.1176 | 0.1176 | 1.000 | | Climate change | 173.5 | 173.5 | 1.000 | | EF-particulate Matter | 9.367e-06 | 9.367e-06 | 1.000 | | Ecotoxicity, freshwater_inorganics | 1444 | 1469 | 0.983 | | Ecotoxicity, freshwater_organics | 31.26 | 27.4 | 1.141 | | Ecotoxicity, freshwater | 1475 | 1495 | 0.987 | | Eutrophication marine | 0.3904 | 0.3904 | 1.000 | | Eutrophication, freshwater | 0.3381 | 0.3381 | 1.000 | | Eutrophication, terrestrial | 2.257 | 2.337 | 0.966 | | Human toxicity, cancer_inorganics | 1.910e-07 | 1.903e-07 | 1.004 | | Human toxicity, cancer_organics | 6.068e-08 | 6.068e-08 | 1.000 | | Human toxicity, cancer | 2.517e-07 | 2.509e-07 | 1.003 | | Human toxicity, non-cancer_inorganics | 1.383e-05 | 1.380e-05 | 1.003 | | Human toxicity, non-cancer_organics | 9.852e-07 | 9.850e-07 | 1.000 | | Human toxicity, non-cancer | 1.482e-05 | 1.478e-05 | 1.002 | | Ionising radiation, human health | 51.78 | 51.78 | 1.000 | | Land use | 896.3 | 735.3 | 1.219 | | Ozone depletion | 4.676e-06 | 4.676e-06 | 1.000 | | Photochemical ozone formation - human health | 0.8711 | 0.8711 | 1.000 | | Resource use, fossils | 2418 | 2419 | 1.000 | | Resource use, minerals and metals | 0.007044 | 0.006955 | 1.013 | | Water use | 103.9 | 105.9 | 0.982 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 173.5 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 4.616e+05 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Electric bicycle production, without battery and motor [RER] | 0.941 p | ×0.916 / ×1.09 | lognormal, GSD² 1.09 | -3.2 / +3.5 | 4.9 (Ionising radiation, human health) | | Battery cell, NMC-622 [GLO] | 5 kg | ×0.916 / ×1.09 | lognormal, GSD² 1.09 | -2.4 / +2.7 | 8.0 (Water use) | | Electric motor, electric vehicle, at plant [RER] | 4 kg | ×0.916 / ×1.09 | lognormal, GSD² 1.09 | -0.6 / +0.6 | 0.8 (EF-particulate Matter) | | Charging station, 500W [GLO] | 1 p | ×0.916 / ×1.09 | lognormal, GSD² 1.09 | -0.5 / +0.6 | 2.5 (Resource use, minerals and metals) | | Battery BoP [GLO] | 1.5 kg | ×0.916 / ×1.09 | lognormal, GSD² 1.09 | -0.5 / +0.5 | 1.7 (Resource use, minerals and metals) | | Disposal, electric bicycle [CH] | 0.667 p | ×0.916 / ×1.09 | lognormal, GSD² 1.09 | -0.4 / +0.4 | 0.4 (Climate change-Fossil) | | Transport, transoceanic container ship [OCE] | 370 tkm | ×0.916 / ×1.09 | lognormal, GSD² 1.09 | -0.3 / +0.3 | 2.3 (Eutrophication, terrestrial) | | Transport, freight, lorry, 16t-32t gross weight, fleet average [RER] | 23.3 tkm | ×0.916 / ×1.09 | lognormal, GSD² 1.09 | -0.2 / +0.3 | 1.5 (Climate change-Land use and land use change) | | Disposal, Li-ions batteries, mixed technology [GLO] | 6.5 kg | ×0.916 / ×1.09 | lognormal, GSD² 1.09 | -0.2 / +0.3 | 0.5 (Climate change-Biogenic) | | Disposal, electric bicycle [CH] | 0.167 p | ×0.916 / ×1.09 | lognormal, GSD² 1.09 | -0.1 / +0.1 | 0.1 (Climate change-Fossil) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 173.5 kg CO2 eq per p (95 % interval 168.3–208). Dominant contributors: Electric bicycle production, without battery and motor 38 %; Battery cell, NMC-622 29 %; Electric motor, electric vehicle, at plant 7 %; Charging station, 500W 6 %; Battery BoP 6 %; Disposal, electric bicycle 4 %. Most sensitive: Electric bicycle production, without battery and motor [RER] (-3.2 / +3.5 %); Battery cell, NMC-622 [GLO] (-2.4 / +2.7 %); Electric motor, electric vehicle, at plant [RER] (-0.6 / +0.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.5e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 23/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 10/11 exchanges carry a distribution (91 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 173.5 in [168.3, 208] | | time period declared | **PASS** | 2020-01/2020-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 1 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Sacchi R., Bauer C. (2021). Life cycle inventories for on-road vehicles. Zenodo. https://doi.org/10.5281/ZENODO.5156043 — //published source; DOI resolved at doi.org// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].