====== Controller, for electric scooter — RER ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:controller_for_electric_scooter__rer|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Controller, for electric scooter [RER], per 1 kg. EF v3.1 climate change 31.59 kg CO2 eq (Monte Carlo 95 % interval 27.86–47.32). Main contributors: Capacitor, electrolyte type, > 2cm height, at plant 29 %; Production efforts, capacitors 24 %; Insulated gate bipolar transistor, electric vehicle applicat… 20 %; Production efforts, transistors 7 %; Aluminium, production mix, cast alloy, at plant 6 %; Integrated circuit, IC, logic type, at plant 4 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Controller, for electric scooter | | Dataset UUID / graph id | ''%%030a7a5b-7a40-3037-a2a7-aa9a8058ea14%%'' / ''%%activity:controller_for_electric_scooter__rer%%'' | | Reference product, unit | Controller, for electric scooter, 1 kg | | Location | RER | | Time period | 2014-01/2014-12 | | Category | transport systems / road | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== This dataset describes the production of a controller suitable for the power electronics of an electric scooter. It comprises the various electronic components making out the logic control unit and the power transistors (IGBTs). The entries are given on a function of kg of device. The original data was collected for a device of approximately 1.3 kg weight. The dataset is based on direct inspection of existing commercial devices of current technology.; UUID: 030a7a5b-7a40-3037-a2a7-aa9a8058ea14 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kg** of Controller, for electric scooter (RER). All results are given per unit of the reference flow. ==== System boundary ==== The datasets takes as input the various electronic components required to build the controller and includes the components" production efforts. Assembly energy not included due to lack of data. The dataset returns the assembled device and production waste as a by-product. ==== Technology ==== — ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Capacitor, electrolyte type, > 2cm height, at plant | technosphere | GLO | 0.23228 | kg | lognormal, GSD² 1.15 | — | 29.5 | ██████ | | | Production efforts, capacitors | technosphere | GLO | 0.23474 | kg | lognormal, GSD² 1.15 | — | 23.7 | █████ | | | Insulated gate bipolar transistor, electric vehicle application | technosphere | RER | 0.5811 | kg | lognormal, GSD² 1.15 | — | 20.2 | ████ | | | Production efforts, transistors | technosphere | GLO | 0.020329 | kg | lognormal, GSD² 1.15 | — | 6.8 | █ | | | Aluminium, production mix, cast alloy, at plant | technosphere | RER | 0.44173 | kg | lognormal, GSD² 1.15 | — | 6.0 | █ | | | Integrated circuit, IC, logic type, at plant | technosphere | GLO | 0.002063 | kg | lognormal, GSD² 1.15 | — | 3.9 | █ | | | Aluminium product manufacturing, average metal working | technosphere | RER | 0.40157 | kg | lognormal, GSD² 1.28 | — | 2.7 | █ | | | Transistor, SMD type, surface mounting, at plant | technosphere | GLO | 0.003937 | kg | lognormal, GSD² 1.15 | — | 1.9 | · | | | Cable, ribbon cable, 20-pin, with plugs, at plant | technosphere | GLO | 0.047244 | kg | lognormal, GSD² 1.15 | — | 1.3 | · | | | Printed wiring board, through-hole, lead-free surface, at plant | technosphere | GLO | 0.0050551 | m2 | lognormal, GSD² 1.15 | — | 1.2 | · | | | Mounting, through-hole technology, Pb-free solder | technosphere | GLO | 0.0050551 | m2 | lognormal, GSD² 1.15 | — | 0.5 | · | | | Resistor, SMD type, surface mounting, at plant | technosphere | GLO | 5.4016e-04 | kg | lognormal, GSD² 1.15 | — | 0.3 | · | | | Diode, glass-, through-hole mounting, at plant | technosphere | GLO | 4.5354e-04 | kg | lognormal, GSD² 1.15 | — | 0.3 | · | | | Production efforts, diodes | technosphere | GLO | 4.5354e-04 | kg | lognormal, GSD² 1.15 | — | 0.3 | · | | | Transistor, wired, small size, through-hole mounting, at plant | technosphere | GLO | 6.4409e-04 | kg | lognormal, GSD² 1.15 | — | 0.2 | · | | | Production efforts, resistors | technosphere | GLO | 0.0029024 | kg | lognormal, GSD² 1.15 | — | 0.2 | · | | | Capacitor, SMD type, surface-mounting, at plant | technosphere | GLO | 0.0013543 | kg | lognormal, GSD² 1.15 | — | 0.2 | · | | | Inductor, ring core choke type, at plant | technosphere | GLO | 0.0015748 | kg | lognormal, GSD² 1.15 | — | 0.2 | · | | | Resistor, wirewound, through-hole mounting, at plant | technosphere | GLO | 0.0023622 | kg | lognormal, GSD² 1.15 | — | 0.2 | · | | | Production efforts, inductors | technosphere | GLO | 0.0015748 | kg | lognormal, GSD² 1.15 | — | 0.1 | · | | | Capacitor, film, through-hole mounting, at plant | technosphere | GLO | 0.0011024 | kg | lognormal, GSD² 1.15 | — | 0.1 | · | | | Transformer, low voltage use, at plant | technosphere | GLO | 0.007874 | kg | lognormal, GSD² 1.17 | — | 0.1 | · | | | Transport, freight, lorry, fleet average | technosphere | RER | 0.059279 | tkm | lognormal, GSD² 1.25 | — | 0.0 | · | | | Polyethylene, HDPE, granulate, at plant | technosphere | RER | 0.003937 | kg | lognormal, GSD² 1.15 | — | 0.0 | · | | | Synthetic rubber, at plant | technosphere | RER | 0.0015748 | kg | lognormal, GSD² 1.15 | — | 0.0 | · | | | Copper, at regional storage | technosphere | RER | 0.002562 | kg | lognormal, GSD² 1.15 | — | 0.0 | · | | | Transport, freight, rail | technosphere | RER | 0.11856 | tkm | lognormal, GSD² 1.25 | — | 0.0 | · | | ==== Data quality ==== 0 of 27 direct exchanges carry a declared pedigree, 27 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Frank Werner (U+E); data entry: Andrea Delduce (QUANTIS); validation (proof reading): Andrea Delduce (QUANTIS) | | extrapolations | | | sampling procedure | Direct inspection of a typical device of common technology. | | production volume | 986370 kg | | uncertainty adjustments | | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kg. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **0.1228** | 0.1109 | 0.2046 | 1.38 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.1264** | 0.07444 | 0.3289 | 2.09 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **31.44** | 27.72 | 47.01 | 1.29 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.0225** | 0.01609 | 0.03813 | 1.56 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **31.59** | 27.86 | 47.32 | 1.29 | | EF-particulate Matter | Impact on human health | disease incidence | **1.056e-06** | 9.965e-07 | 1.886e-06 | 1.41 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **144.8** | 136.7 | 297.9 | 1.51 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **3.784** | 3.555 | 7.269 | 1.47 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **148.6** | 141 | 305 | 1.5 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **0.02573** | 0.02411 | 0.04368 | 1.36 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **0.03331** | 0.02246 | 0.1971 | 3.04 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **0.2307** | 0.2096 | 0.4183 | 1.45 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.586e-08** | 1.479e-08 | 5.340e-08 | 1.87 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.931e-09** | 6.573e-09 | 1.506e-08 | 1.52 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.379e-08** | 2.285e-08 | 6.661e-08 | 1.67 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **9.893e-07** | 9.367e-07 | 3.224e-06 | 1.85 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **4.806e-08** | 3.776e-08 | 1.054e-07 | 1.7 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.037e-06** | 9.879e-07 | 3.331e-06 | 1.83 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **7.862** | 2.479 | 53 | 4.89 | | Land use | Soil quality index | pt (soil quality index) | **206.1** | 161.9 | 513.9 | 1.83 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **9.219e-07** | 8.500e-07 | 1.446e-06 | 1.3 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **0.1752** | 0.1507 | 0.2775 | 1.36 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **457** | 411.5 | 724.9 | 1.33 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.003062** | 0.002601 | 0.004012 | 1.25 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **3.937** | -1.284e+04 | 6814 | — | Climate change 31.59 kg CO2 eq per kg. Main contributors: Capacitor, electrolyte type, > 2cm height, at plant 29 %; Production efforts, capacitors 24 %; Insulated gate bipolar transistor, electric vehicle applicat… 20 %; Production efforts, transistors 7 %; Aluminium, production mix, cast alloy, at plant 6 %; Integrated circuit, IC, logic type, at plant 4 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Capacitor, electrolyte type, > 2cm height, at plant 29 %; Production efforts, capacitors 24 %; Insulated gate bipolar transistor, electric vehicle applicat… 20 %; Production efforts, transistors 7 %; Aluminium, production mix, cast alloy, at plant 6 %; Integrated circuit, IC, logic type, at plant 4 %. Most sensitive exchanges (Section 6.3): Capacitor, electrolyte type, > 2cm height, at plant [GLO] (-3.7 / +4.2 %); Production efforts, capacitors [GLO] (-3.0 / +3.4 %); Insulated gate bipolar transistor, electric vehicle application [RER] (-2.5 / +2.9 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 0.1228 | 0.1663 | 0.738 | | Climate change-Biogenic | 0.1264 | 0.1264 | 1.000 | | Climate change-Fossil | 31.44 | 31.44 | 1.000 | | Climate change-Land use and land use change | 0.0225 | 0.0225 | 1.000 | | Climate change | 31.59 | 31.59 | 1.000 | | EF-particulate Matter | 1.056e-06 | 1.056e-06 | 1.000 | | Ecotoxicity, freshwater_inorganics | 144.8 | 147.1 | 0.984 | | Ecotoxicity, freshwater_organics | 3.784 | 3.32 | 1.140 | | Ecotoxicity, freshwater | 148.6 | 149.5 | 0.994 | | Eutrophication marine | 0.02573 | 0.02573 | 1.000 | | Eutrophication, freshwater | 0.03331 | 0.03331 | 1.000 | | Eutrophication, terrestrial | 0.2307 | 0.247 | 0.934 | | Human toxicity, cancer_inorganics | 1.586e-08 | 1.575e-08 | 1.007 | | Human toxicity, cancer_organics | 7.931e-09 | 7.930e-09 | 1.000 | | Human toxicity, cancer | 2.379e-08 | 2.369e-08 | 1.004 | | Human toxicity, non-cancer_inorganics | 9.893e-07 | 9.836e-07 | 1.006 | | Human toxicity, non-cancer_organics | 4.806e-08 | 4.803e-08 | 1.001 | | Human toxicity, non-cancer | 1.037e-06 | 1.032e-06 | 1.006 | | Ionising radiation, human health | 7.862 | 7.862 | 1.000 | | Land use | 206.1 | 161.3 | 1.278 | | Ozone depletion | 9.219e-07 | 9.219e-07 | 1.000 | | Photochemical ozone formation - human health | 0.1752 | 0.1752 | 1.000 | | Resource use, fossils | 457 | 457.1 | 1.000 | | Resource use, minerals and metals | 0.003062 | 0.00305 | 1.004 | | Water use | 3.937 | 10.21 | 0.385 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 31.59 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 7.112e+04 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Capacitor, electrolyte type, > 2cm height, at plant [GLO] | 0.2323 kg | ×0.876 / ×1.14 | lognormal, GSD² 1.15 | -3.7 / +4.2 | 5.1 (Land use) | | Production efforts, capacitors [GLO] | 0.2347 kg | ×0.876 / ×1.14 | lognormal, GSD² 1.15 | -3.0 / +3.4 | 4.5 (Photochemical ozone formation - human health) | | Insulated gate bipolar transistor, electric vehicle application [RER] | 0.5811 kg | ×0.876 / ×1.14 | lognormal, GSD² 1.15 | -2.5 / +2.9 | 5.7 (Ozone depletion) | | Production efforts, transistors [GLO] | 0.02033 kg | ×0.876 / ×1.14 | lognormal, GSD² 1.15 | -0.8 / +1.0 | 1.3 (Human toxicity, cancer_organics) | | Aluminium, production mix, cast alloy, at plant [RER] | 0.4417 kg | ×0.876 / ×1.14 | lognormal, GSD² 1.15 | -0.7 / +0.8 | 1.8 (Ionising radiation, human health) | | Aluminium product manufacturing, average metal working [RER] | 0.4016 kg | ×0.785 / ×1.27 | lognormal, GSD² 1.28 | -0.6 / +0.7 | 1.5 (Ionising radiation, human health) | | Integrated circuit, IC, logic type, at plant [GLO] | 0.002063 kg | ×0.876 / ×1.14 | lognormal, GSD² 1.15 | -0.5 / +0.6 | 6.1 (Resource use, minerals and metals) | | Transistor, SMD type, surface mounting, at plant [GLO] | 0.003937 kg | ×0.876 / ×1.14 | lognormal, GSD² 1.15 | -0.2 / +0.3 | 2.4 (Resource use, minerals and metals) | | Cable, ribbon cable, 20-pin, with plugs, at plant [GLO] | 0.04724 kg | ×0.876 / ×1.14 | lognormal, GSD² 1.15 | -0.2 / +0.2 | 1.6 (Human toxicity, non-cancer_inorganics) | | Printed wiring board, through-hole, lead-free surface, at plant [GLO] | 0.005055 m2 | ×0.876 / ×1.14 | lognormal, GSD² 1.15 | -0.2 / +0.2 | 0.6 (Human toxicity, non-cancer_organics) | | Mounting, through-hole technology, Pb-free solder [GLO] | 0.005055 m2 | ×0.876 / ×1.14 | lognormal, GSD² 1.15 | -0.1 / +0.1 | 0.6 (Resource use, minerals and metals) | | Resistor, SMD type, surface mounting, at plant [GLO] | 5.402e-04 kg | ×0.876 / ×1.14 | lognormal, GSD² 1.15 | -0.0 / +0.0 | 1.0 (Resource use, minerals and metals) | | Diode, glass-, through-hole mounting, at plant [GLO] | 4.535e-04 kg | ×0.876 / ×1.14 | lognormal, GSD² 1.15 | -0.0 / +0.0 | 0.1 (Ionising radiation, human health) | | Production efforts, diodes [GLO] | 4.535e-04 kg | ×0.876 / ×1.14 | lognormal, GSD² 1.15 | -0.0 / +0.0 | 0.1 (Ionising radiation, human health) | | Transistor, wired, small size, through-hole mounting, at plant [GLO] | 6.441e-04 kg | ×0.876 / ×1.14 | lognormal, GSD² 1.15 | -0.0 / +0.0 | 0.0 (Human toxicity, non-cancer_organics) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 31.59 kg CO2 eq per kg (95 % interval 27.86–47.32). Dominant contributors: Capacitor, electrolyte type, > 2cm height, at plant 29 %; Production efforts, capacitors 24 %; Insulated gate bipolar transistor, electric vehicle applicat… 20 %; Production efforts, transistors 7 %; Aluminium, production mix, cast alloy, at plant 6 %; Integrated circuit, IC, logic type, at plant 4 %. Most sensitive: Capacitor, electrolyte type, > 2cm height, at plant [GLO] (-3.7 / +4.2 %); Production efforts, capacitors [GLO] (-3.0 / +3.4 %); Insulated gate bipolar transistor, electric vehicle application [RER] (-2.5 / +2.9 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kg | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 5.7e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 20/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 27/27 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 31.59 in [27.86, 47.32] | | time period declared | **PASS** | 2014-01/2014-12 | | geography is a known location code | **PASS** | RER | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - none — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].