====== Electric parts of Mini CHP plant — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:electric_parts_of_mini_chp_plant__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electric parts of Mini CHP plant [CH], per 1 p. EF v3.1 climate change 362.1 kg CO2 eq (Monte Carlo 95 % interval 306.1–500.8). Main contributors: Light fuel oil, burned in industrial furnace 1MW, non-modula… 32 %; Natural gas, burned in industrial furnace 1MWth 26 %; Electricity, medium voltage, production ENTSO-E, at grid 17 %; Reinforcing steel, at plant 13 %; Polyethylene, LDPE, granulate, at plant 8 %; Platinum, at regional storage 1 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Electric parts of Mini CHP plant | | Dataset UUID / graph id | ''%%033c2e16-6df5-3977-a829-869d40fa6dab%%'' / ''%%activity:electric_parts_of_mini_chp_plant__ch%%'' | | Reference product, unit | Electric parts of Mini CHP plant, 1 p | | Location | CH — Could be used for central European conditions. | | Time period | 1997-01/2000-12 | | Category | heat / natural gas\cogeneration\power unit\infrastructure | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Inventory based on information from manufacturer (Ecopower 1997; UUID: 033c2e16-6df5-3977-a829-869d40fa6dab This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Electric parts of Mini CHP plant (CH). All results are given per unit of the reference flow. ==== System boundary ==== The module includes the most important materials used for production. It includes also the transport of these materials and the energy and water needed for production. ==== Technology ==== Specific manufacturer (Ecopower in Switzerland) ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Light fuel oil, burned in industrial furnace 1MW, non-modulating | technosphere | CH | 1230 | MJ | lognormal, GSD² 1.55 | (3,3,3,3,4,3) | 32.3 | ██████ | | | Natural gas, burned in industrial furnace 1MWth | technosphere | CH | 1230 | MJ | lognormal, GSD² 1.55 | (3,3,3,3,4,3) | 25.9 | █████ | | | Electricity, medium voltage, production ENTSO-E, at grid | technosphere | ENTSO-E | 222 | kWh | lognormal, GSD² 1.55 | (3,3,3,3,4,3) | 16.8 | ███ | | | Reinforcing steel, at plant | technosphere | RER | 34.1 | kg | lognormal, GSD² 2.06 | — | 13.2 | ███ | | | Polyethylene, LDPE, granulate, at plant | technosphere | RER | 12.7 | kg | lognormal, GSD² 2.06 | — | 8.2 | ██ | | | Platinum, at regional storage | technosphere | RER | 5.0000e-04 | kg | lognormal, GSD² 2.06 | — | 1.4 | · | | | Polyvinylchloride, at regional storage | technosphere | RER | 1.2 | kg | lognormal, GSD² 2.06 | — | 0.8 | · | | | Copper, at regional storage | technosphere | RER | 1.74 | kg | lognormal, GSD² 2.06 | — | 0.8 | · | | | Transport, freight, lorry, fleet average | technosphere | RER | 5 | tkm | lognormal, GSD² 2.49 | — | 0.3 | · | | | Nickel, 99.5%, at plant | technosphere | GLO | 0.06 | kg | lognormal, GSD² 2.06 | — | 0.2 | · | | | Aluminium, primary, at plant | technosphere | RER | 0.03 | kg | lognormal, GSD² 2.06 | — | 0.1 | · | | | Transport, freight, rail | technosphere | RER | 10 | tkm | lognormal, GSD² 2.49 | — | 0.0 | · | | | Lead, at regional storage | technosphere | RER | 0.13 | kg | lognormal, GSD² 2.06 | — | 0.0 | · | | | Zinc, primary, at regional storage | technosphere | RER | 0.04 | kg | lognormal, GSD² 2.06 | — | 0.0 | · | | | Treatment, pig iron production effluent, to wastewater treatment, class 3 | technosphere | CH | 0.0433 | m3 | lognormal, GSD² 3 | — | 0.0 | · | | | Waste Heat | elementary | air/Unknown | 800 | MJ | lognormal, GSD² 1.55 | (3,3,3,3,4,3) | 0.0 | · | | | Water, CH | elementary | natural resource [CH] | 0.0541 | m3 | lognormal, GSD² 3 | — | 0.0 | · | | | Water, CH | elementary | water/Unknown [CH] | 0.051395 | m3 | lognormal, GSD² 2.52 | — | 0.0 | · | | ==== Data quality ==== 4 of 18 direct exchanges carry a declared pedigree, 18 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.0 · completeness 3.0 · temporal 3.0 · geographical 3.0 · technological 4.0 · sample size 3.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Thomas Heck; data entry: Thomas Heck; validation (proof reading): Gerald Rebitzer | | extrapolations | none | | sampling procedure | Operator and manufacturer information | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: had passed; Other validation: none; | | time period comment | undefined | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **0.9674** | 0.8152 | 1.471 | 1.37 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.35** | 0.7347 | 3.293 | 2.14 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **360.7** | 303.6 | 498.8 | 1.29 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.07066** | 0.05954 | 0.1174 | 1.42 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **362.1** | 306.1 | 500.8 | 1.29 | | EF-particulate Matter | Impact on human health | disease incidence | **8.207e-06** | 6.997e-06 | 1.445e-05 | 1.45 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1229** | 1036 | 3023 | 1.73 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **57.07** | 41.13 | 144 | 1.92 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1286** | 1091 | 3095 | 1.7 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **0.1741** | 0.1529 | 0.273 | 1.35 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **0.2011** | 0.1231 | 1.079 | 2.96 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **1.537** | 1.339 | 2.427 | 1.36 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.083e-07** | 9.760e-08 | 3.715e-07 | 2.01 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **6.565e-07** | 2.682e-07 | 2.339e-06 | 2.99 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **7.649e-07** | 4.288e-07 | 2.576e-06 | 2.46 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **6.152e-06** | 5.231e-06 | 1.978e-05 | 1.93 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **8.018e-07** | 5.017e-07 | 1.723e-06 | 1.89 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **6.954e-06** | 6.028e-06 | 2.081e-05 | 1.86 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **106.1** | 37.99 | 665.1 | 4.37 | | Land use | Soil quality index | pt (soil quality index) | **1006** | 830.5 | 1841 | 1.53 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **1.171e-05** | 9.650e-06 | 1.958e-05 | 1.44 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **0.9958** | 0.8467 | 1.558 | 1.36 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **6066** | 4968 | 9348 | 1.37 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.003944** | 0.002822 | 0.006602 | 1.55 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **25.71** | -8.028e+04 | 4.262e+04 | — | Climate change 362.1 kg CO2 eq per p. Main contributors: Light fuel oil, burned in industrial furnace 1MW, non-modula… 32 %; Natural gas, burned in industrial furnace 1MWth 26 %; Electricity, medium voltage, production ENTSO-E, at grid 17 %; Reinforcing steel, at plant 13 %; Polyethylene, LDPE, granulate, at plant 8 %; Platinum, at regional storage 1 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Light fuel oil, burned in industrial furnace 1MW, non-modula… 32 %; Natural gas, burned in industrial furnace 1MWth 26 %; Electricity, medium voltage, production ENTSO-E, at grid 17 %; Reinforcing steel, at plant 13 %; Polyethylene, LDPE, granulate, at plant 8 %; Platinum, at regional storage 1 %. Most sensitive exchanges (Section 6.3): Light fuel oil, burned in industrial furnace 1MW, non-modulating [CH] (-11.3 / +17.3 %); Natural gas, burned in industrial furnace 1MWth [CH] (-9.0 / +13.9 %); Reinforcing steel, at plant [RER] (-6.7 / +13.6 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 0.9674 | 2.814 | 0.344 | | Climate change-Biogenic | 1.35 | 1.35 | 1.000 | | Climate change-Fossil | 360.7 | 360.7 | 1.000 | | Climate change-Land use and land use change | 0.07066 | 0.07066 | 1.000 | | Climate change | 362.1 | 362.1 | 1.000 | | EF-particulate Matter | 8.207e-06 | 8.207e-06 | 1.000 | | Ecotoxicity, freshwater_inorganics | 1229 | 1248 | 0.984 | | Ecotoxicity, freshwater_organics | 57.07 | 56.93 | 1.002 | | Ecotoxicity, freshwater | 1286 | 1297 | 0.991 | | Eutrophication marine | 0.1741 | 0.174 | 1.000 | | Eutrophication, freshwater | 0.2011 | 0.2011 | 1.000 | | Eutrophication, terrestrial | 1.537 | 1.729 | 0.889 | | Human toxicity, cancer_inorganics | 1.083e-07 | 1.065e-07 | 1.017 | | Human toxicity, cancer_organics | 6.565e-07 | 6.565e-07 | 1.000 | | Human toxicity, cancer | 7.649e-07 | 7.631e-07 | 1.002 | | Human toxicity, non-cancer_inorganics | 6.152e-06 | 6.081e-06 | 1.012 | | Human toxicity, non-cancer_organics | 8.018e-07 | 8.018e-07 | 1.000 | | Human toxicity, non-cancer | 6.954e-06 | 6.882e-06 | 1.010 | | Ionising radiation, human health | 106.1 | 106.1 | 1.000 | | Land use | 1006 | 882.3 | 1.141 | | Ozone depletion | 1.171e-05 | 1.171e-05 | 1.000 | | Photochemical ozone formation - human health | 0.9958 | 0.9958 | 1.000 | | Resource use, fossils | 6066 | 6069 | 1.000 | | Resource use, minerals and metals | 0.003944 | 0.003913 | 1.008 | | Water use | 25.71 | 28.68 | 0.896 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 362.1 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 6.945e+05 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Light fuel oil, burned in industrial furnace 1MW, non-modulating [CH] | 1230 MJ | ×0.651 / ×1.54 | lognormal, GSD² 1.55 | -11.3 / +17.3 | 17.4 (Climate change-Fossil) | | Natural gas, burned in industrial furnace 1MWth [CH] | 1230 MJ | ×0.651 / ×1.54 | lognormal, GSD² 1.55 | -9.0 / +13.9 | 13.9 (Climate change-Fossil) | | Reinforcing steel, at plant [RER] | 34.1 kg | ×0.493 / ×2.03 | lognormal, GSD² 2.06 | -6.7 / +13.6 | 36.3 (EF-particulate Matter) | | Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] | 222 kWh | ×0.651 / ×1.54 | lognormal, GSD² 1.55 | -5.9 / +9.0 | 41.1 (Climate change-Biogenic) | | Polyethylene, LDPE, granulate, at plant [RER] | 12.7 kg | ×0.493 / ×2.03 | lognormal, GSD² 2.06 | -4.2 / +8.5 | 90.3 (Human toxicity, cancer_organics) | | Platinum, at regional storage [RER] | 5.000e-04 kg | ×0.493 / ×2.03 | lognormal, GSD² 2.06 | -0.7 / +1.5 | 50.6 (Human toxicity, non-cancer_organics) | | Polyvinylchloride, at regional storage [RER] | 1.2 kg | ×0.493 / ×2.03 | lognormal, GSD² 2.06 | -0.4 / +0.8 | 9.7 (Ozone depletion) | | Copper, at regional storage [RER] | 1.74 kg | ×0.493 / ×2.03 | lognormal, GSD² 2.06 | -0.4 / +0.8 | 52.5 (Human toxicity, non-cancer_inorganics) | | Transport, freight, lorry, fleet average [RER] | 5 tkm | ×0.409 / ×2.44 | lognormal, GSD² 2.49 | -0.2 / +0.4 | 7.4 (Climate change-Land use and land use change) | | Nickel, 99.5%, at plant [GLO] | 0.06 kg | ×0.493 / ×2.03 | lognormal, GSD² 2.06 | -0.1 / +0.2 | 11.9 (Acidification) | | Aluminium, primary, at plant [RER] | 0.03 kg | ×0.493 / ×2.03 | lognormal, GSD² 2.06 | -0.0 / +0.1 | 0.6 (Climate change-Land use and land use change) | | Transport, freight, rail [RER] | 10 tkm | ×0.409 / ×2.44 | lognormal, GSD² 2.49 | -0.0 / +0.1 | 0.8 (Land use) | | Lead, at regional storage [RER] | 0.13 kg | ×0.493 / ×2.03 | lognormal, GSD² 2.06 | -0.0 / +0.0 | 5.8 (Resource use, minerals and metals) | | Zinc, primary, at regional storage [RER] | 0.04 kg | ×0.493 / ×2.03 | lognormal, GSD² 2.06 | -0.0 / +0.0 | 0.7 (Resource use, minerals and metals) | | Treatment, pig iron production effluent, to wastewater treatment, class 3 [CH] | 0.0433 m3 | ×0.341 / ×2.93 | lognormal, GSD² 3 | -0.0 / +0.0 | 0.0 (Land use) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 362.1 kg CO2 eq per p (95 % interval 306.1–500.8). Dominant contributors: Light fuel oil, burned in industrial furnace 1MW, non-modula… 32 %; Natural gas, burned in industrial furnace 1MWth 26 %; Electricity, medium voltage, production ENTSO-E, at grid 17 %; Reinforcing steel, at plant 13 %; Polyethylene, LDPE, granulate, at plant 8 %; Platinum, at regional storage 1 %. Most sensitive: Light fuel oil, burned in industrial furnace 1MW, non-modulating [CH] (-11.3 / +17.3 %); Natural gas, burned in industrial furnace 1MWth [CH] (-9.0 / +13.9 %); Reinforcing steel, at plant [RER] (-6.7 / +13.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 4.8e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 18/18 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 362.1 in [306.1, 500.8] | | time period declared | **PASS** | 1997-01/2000-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Heck, T. (2007) Wärme-Kraft-Kopplung. Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0. Editors: Dones R.. Volume: 6. Swiss Centre for LCI, PSI. Dübendorf and Villigen, CH. Type: Measurement on site Source: CD-ROM First author: Heck, T. Year: 2007 Name of editors: Dones R. Title of anthology: Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0 Place of … — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].