====== xx Hydrogen, from butanediol dehdrogenation — GLO ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:xx_hydrogen_from_butanediol_dehdrogenation__glo|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset xx Hydrogen, from butanediol dehdrogenation [GLO], per 1 kg. EF v3.1 climate change 2.252 kg CO2 eq (Monte Carlo 95 % interval 1.65–3.728). Main contributors: Butane-1,4-diol, at plant 93 %; Heat, natural gas, at industrial furnace 1MW 3 %; Electricity, medium voltage, production ENTSO-E, at grid 2 %; Carbon Dioxide (fossil) 2 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | xx Hydrogen, from butanediol dehdrogenation | | Dataset UUID / graph id | ''%%0b68a03d-d566-3b69-a05c-b4706963c8e5%%'' / ''%%activity:xx_hydrogen_from_butanediol_dehdrogenation__glo%%'' | | Reference product, unit | xx Hydrogen, from butanediol dehdrogenation, 1 kg | | Location | GLO — The inventory is modelled for the world.. | | Time period | 2000-01/2007-12 | | Category | material, obsolete / chemicals, obsolete\gases, obsolete | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== The multioutput-process "butanediol dehygrogenation " delivers the co-products butyrolactone and hydrogen. The allocation is based on stoechiometric calculation.; UUID: 0b68a03d-d566-3b69-a05c-b4706963c8e5 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kg** of xx Hydrogen, from butanediol dehdrogenation (GLO). All results are given per unit of the reference flow. ==== System boundary ==== Butanediol dehydrogenation including materials, energy uses, infrastructure and emissions. ==== Technology ==== Dehygrogenation of butanediol ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Butane-1,4-diol, at plant | technosphere | RER | 0.48635 | kg | lognormal, GSD² 1.38 | (4,5,1,1,1,5) | 92.7 | ███████████████████ | | | Heat, natural gas, at industrial furnace 1MW | technosphere | CH | 0.88302 | MJ | lognormal, GSD² 1.3 | — | 3.1 | █ | | | Electricity, medium voltage, production ENTSO-E, at grid | technosphere | ENTSO-E | 0.14702 | kWh | lognormal, GSD² 1.3 | — | 1.8 | · | | | Transport, freight, lorry, fleet average | technosphere | RER | 0.048635 | tkm | lognormal, GSD² 2.1 | — | 0.4 | · | | | Transport, freight, rail | technosphere | RER | 0.29181 | tkm | lognormal, GSD² 2.1 | — | 0.2 | · | | | Chemical plant, organics | technosphere | RER | 4.4150e-11 | p | lognormal, GSD² 3.09 | — | 0.2 | · | | | Carbon Dioxide (fossil) | elementary | air/Ground level / Urban (>1000 people/s… | 0.034239 | kg | lognormal, GSD² 1.3 | — | 1.5 | · | | | Chemical Oxygen Demand | elementary | water/Surface water | 0.0036476 | kg | lognormal, GSD² 1.62 | — | 0.0 | · | | | Butylene Glycol | elementary | water/River | 0.0019454 | kg | lognormal, GSD² 1.3 | — | 0.0 | · | | | DOC, Dissolved Organic Carbon | elementary | water/River | 0.0010359 | kg | lognormal, GSD² 1.62 | — | 0.0 | · | | | Biological Oxygen Demand | elementary | water/River | 0.0036476 | kg | lognormal, GSD² 1.62 | — | 0.0 | · | | | Butylene Glycol | elementary | air/Ground level / Urban (>1000 people/s… | 0.0048635 | kg | lognormal, GSD² 1.3 | — | 0.0 | · | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 0.52925 | MJ | lognormal, GSD² 1.3 | — | 0.0 | · | | | Cooling water | elementary | natural resource | 0.010596 | m3 | lognormal, GSD² 1.3 | — | 0.0 | · | | | Total Organic Carbon | elementary | water/River | 0.010359 | kg | lognormal, GSD² 1.62 | — | 0.0 | · | | | Water | elementary | water/Unknown | 0.010066 | m3 | lognormal, GSD² 2.52 | — | 0.0 | · | | ==== Data quality ==== 1 of 16 direct exchanges carry a declared pedigree, 16 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 4.0 · completeness 5.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 5.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Juergen Sutter; data entry: Juergen Sutter; validation (proof reading): Roland Hischier (EMPA) | | extrapolations | Energy consumptions, emissions, infrastructure and transports are calculated with standard values. | | sampling procedure | Literature data | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: passed.; Other validation: none; | | time period comment | Time of publications. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kg. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **0.004418** | 0.003275 | 0.007843 | 1.56 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.006053** | 0.003477 | 0.01601 | 2.21 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2.246** | 1.645 | 3.71 | 1.51 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **5.347e-04** | 4.180e-04 | 9.601e-04 | 1.51 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2.252** | 1.65 | 3.728 | 1.51 | | EF-particulate Matter | Impact on human health | disease incidence | **4.386e-08** | 3.234e-08 | 8.912e-08 | 1.69 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **7.193** | 4.593 | 20.38 | 2.15 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.6616** | 0.4919 | 1.295 | 1.64 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **7.855** | 5.218 | 21.41 | 2.06 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **0.001109** | 8.746e-04 | 0.001957 | 1.51 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **4.874e-04** | 2.964e-04 | 0.002041 | 2.66 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **0.009947** | 0.007703 | 0.0179 | 1.52 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.627e-10** | 1.652e-10 | 5.240e-10 | 1.82 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.259e-09** | 9.108e-10 | 1.956e-09 | 1.48 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.422e-09** | 1.123e-09 | 2.411e-09 | 1.48 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.079e-08** | 1.037e-08 | 3.553e-08 | 1.89 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.753e-09** | 1.493e-09 | 2.815e-09 | 1.38 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.254e-08** | 1.205e-08 | 3.836e-08 | 1.82 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.5178** | 0.1802 | 3.496 | 4.52 | | Land use | Soil quality index | pt (soil quality index) | **6.176** | 4.913 | 13.27 | 1.65 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **6.003e-08** | 4.244e-08 | 1.213e-07 | 1.72 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **0.006245** | 0.004613 | 0.01133 | 1.56 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **44.05** | 31.47 | 77.33 | 1.58 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **5.053e-06** | 2.837e-06 | 2.037e-05 | 2.76 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.6458** | -342 | 167.6 | — | Climate change 2.252 kg CO2 eq per kg. Main contributors: Butane-1,4-diol, at plant 93 %; Heat, natural gas, at industrial furnace 1MW 3 %; Electricity, medium voltage, production ENTSO-E, at grid 2 %; Carbon Dioxide (fossil) 2 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Butane-1,4-diol, at plant 93 %; Heat, natural gas, at industrial furnace 1MW 3 %; Electricity, medium voltage, production ENTSO-E, at grid 2 %; Carbon Dioxide (fossil) 2 %. Most sensitive exchanges (Section 6.3): Butane-1,4-diol, at plant [RER] (-24.9 / +34.1 %); Heat, natural gas, at industrial furnace 1MW [CH] (-0.7 / +0.9 %); Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] (-0.4 / +0.5 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 0.004418 | 0.005189 | 0.852 | | Climate change-Biogenic | 0.006053 | 0.006053 | 1.000 | | Climate change-Fossil | 2.246 | 2.246 | 1.000 | | Climate change-Land use and land use change | 5.347e-04 | 5.347e-04 | 1.000 | | Climate change | 2.252 | 2.252 | 1.000 | | EF-particulate Matter | 4.386e-08 | 4.386e-08 | 1.000 | | Ecotoxicity, freshwater_inorganics | 7.193 | 7.251 | 0.992 | | Ecotoxicity, freshwater_organics | 0.6616 | 0.5469 | 1.210 | | Ecotoxicity, freshwater | 7.855 | 7.794 | 1.008 | | Eutrophication marine | 0.001109 | 0.001109 | 1.000 | | Eutrophication, freshwater | 4.874e-04 | 4.874e-04 | 1.000 | | Eutrophication, terrestrial | 0.009947 | 0.01095 | 0.908 | | Human toxicity, cancer_inorganics | 1.627e-10 | 1.551e-10 | 1.049 | | Human toxicity, cancer_organics | 1.259e-09 | 1.259e-09 | 1.000 | | Human toxicity, cancer | 1.422e-09 | 1.415e-09 | 1.005 | | Human toxicity, non-cancer_inorganics | 1.079e-08 | 1.055e-08 | 1.023 | | Human toxicity, non-cancer_organics | 1.753e-09 | 1.655e-09 | 1.059 | | Human toxicity, non-cancer | 1.254e-08 | 1.220e-08 | 1.028 | | Ionising radiation, human health | 0.5178 | 0.5178 | 1.000 | | Land use | 6.176 | 5.113 | 1.208 | | Ozone depletion | 6.003e-08 | 6.003e-08 | 1.000 | | Photochemical ozone formation - human health | 0.006245 | 0.006245 | 1.000 | | Resource use, fossils | 44.05 | 44.06 | 1.000 | | Resource use, minerals and metals | 5.053e-06 | 4.896e-06 | 1.032 | | Water use | 0.6458 | 0.6567 | 0.983 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 2.252 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 3441 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Butane-1,4-diol, at plant [RER] | 0.4864 kg | ×0.731 / ×1.37 | lognormal, GSD² 1.38 | -24.9 / +34.1 | 35.6 (Human toxicity, cancer_organics) | | Heat, natural gas, at industrial furnace 1MW [CH] | 0.883 MJ | ×0.773 / ×1.29 | lognormal, GSD² 1.3 | -0.7 / +0.9 | 1.0 (Ozone depletion) | | Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] | 0.147 kWh | ×0.773 / ×1.29 | lognormal, GSD² 1.3 | -0.4 / +0.5 | 3.3 (Climate change-Biogenic) | | Carbon Dioxide (fossil) [air/Ground level / Urban (>1000 people/square mile)] | 0.03424 kg | ×0.773 / ×1.29 | lognormal, GSD² 1.3 | -0.3 / +0.4 | 0.4 (Climate change-Fossil) | | Transport, freight, lorry, fleet average [RER] | 0.04863 tkm | ×0.484 / ×2.06 | lognormal, GSD² 2.1 | -0.2 / +0.4 | 7.0 (Climate change-Land use and land use change) | | Chemical plant, organics [RER] | 4.415e-11 p | ×0.331 / ×3.02 | lognormal, GSD² 3.09 | -0.1 / +0.4 | 15.0 (Resource use, minerals and metals) | | Transport, freight, rail [RER] | 0.2918 tkm | ×0.484 / ×2.06 | lognormal, GSD² 2.1 | -0.1 / +0.2 | 2.8 (Land use) | | Butylene Glycol [water/River] | 0.001945 kg | ×0.773 / ×1.29 | lognormal, GSD² 1.3 | -0.0 / +0.0 | 5.0 (Ecotoxicity, freshwater_organics) | | Butylene Glycol [air/Ground level / Urban (>1000 people/square mile)] | 0.004863 kg | ×0.773 / ×1.29 | lognormal, GSD² 1.3 | -0.0 / +0.0 | 9.8 (Human toxicity, non-cancer_organics) | | Cooling water [natural resource] | 0.0106 m3 | ×0.773 / ×1.29 | lognormal, GSD² 1.3 | -0.0 / +0.0 | 20.7 (Water use) | | Water [water/Unknown] | 0.01007 m3 | ×0.404 / ×2.47 | lognormal, GSD² 2.52 | -0.0 / +0.0 | 98.6 (Water use) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 2.252 kg CO2 eq per kg (95 % interval 1.65–3.728). Dominant contributors: Butane-1,4-diol, at plant 93 %; Heat, natural gas, at industrial furnace 1MW 3 %; Electricity, medium voltage, production ENTSO-E, at grid 2 %; Carbon Dioxide (fossil) 2 %. Most sensitive: Butane-1,4-diol, at plant [RER] (-24.9 / +34.1 %); Heat, natural gas, at industrial furnace 1MW [CH] (-0.7 / +0.9 %); Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] (-0.4 / +0.5 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kg | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 4.0e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 20/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 16/16 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 2.252 in [1.65, 3.728] | | time period declared | **PASS** | 2000-01/2007-12 | | geography is a known location code | **PASS** | GLO | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Sutter, J., 0 (2007) Life Cycle Inventories of Petrochemical Solvents. Final report ecoinvent Data v2.0. Editors: 0. 0. Volume: 22. Issue: 0. Swiss Centre for LCI, ETHZ. Duebendorf and St. Gallen, CH. Type: Measurement on site Source: CD-ROM First author: Sutter, J. Other authors: 0 Year: 2007 Name of editors: 0 Title of anthology: Final report ecoinvent Data v2.0 Place of publication: Duebendorf … — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].