====== Electricity, natural gas, at power plant — NL ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:electricity_natural_gas_at_power_plant__nl|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity, natural gas, at power plant [NL], per 1 kWh. EF v3.1 climate change 0.4798 kg CO2 eq (Monte Carlo 95 % interval 0.2688–1.115). Main contributors: Natural gas, burned in power plant or heat plant 100 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Electricity, natural gas, at power plant | | Dataset UUID / graph id | ''%%15923ee9-790a-3c6d-aa0f-1c9f4a0fcd93%%'' / ''%%activity:electricity_natural_gas_at_power_plant__nl%%'' | | Reference product, unit | Electricity, natural gas, at power plant, 1 kWh | | Location | NL | | Time period | 2021-01-01+01:00/2023-12-31+01:00 | | Category | electricity by fuel / gas | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Translated name: Strom, ab Erdgas-Kraftwerk Included processes: Electricity output at busbar. The dataset uses the average net efficiency of power plants in the region. The average net electrical efficiency is about 53.6 %. The electricity generation of this technology in the region is at about 20'000 GWh based on international energy statistics. Technology: Average of installed power plants. Time period: 2022 Version: 2024 Percent representativeness: 90 % Production volume: 20'000 GWh Local category: Erdgas Local subcategory: Kraftwerke Generator: Christopher Oberschelp E-mail: contact@oberschelp-consulting.ch; Country: CH Former geography text: NA. UUID: 15923ee9-790a-3c6d-aa0f-1c9f4a0fcd93; UUID: This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kWh** of Electricity, natural gas, at power plant (NL). All results are given per unit of the reference flow. ==== System boundary ==== — ==== Technology ==== — ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Natural gas, burned in power plant or heat plant | technosphere | NL | 6.72 | MJ | lognormal, GSD² 1.21 | — | 100.0 | ████████████████████ | | ==== Data quality ==== 0 of 1 direct exchanges carry a declared pedigree, 1 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Christopher Oberschelp (ETH); data entry: Christopher Oberschelp (ETH); validation (proof reading): René Itten (ZHAW) | | sampling procedure | Databases / literature data based on regional statistics. | | validation details | Proof reading validation: Proof reading validation: had passed; Other validation: none; Validator: René Itten Telephone: 0041 58 934 52 32; E-mail: rene.itten@zhaw.ch; Country: CH | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **3.524e-04** | 1.695e-04 | 0.001403 | 3.01 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2.535e-04** | 4.803e-05 | 0.002148 | 7.26 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.4795** | 0.2684 | 1.112 | 2.07 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **3.454e-05** | 7.824e-06 | 2.271e-04 | 5.58 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.4798** | 0.2688 | 1.115 | 2.07 | | EF-particulate Matter | Impact on human health | disease incidence | **1.431e-09** | 5.906e-10 | 7.883e-09 | 3.88 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.465** | 0.2998 | 9.123 | 5.87 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.03339** | 0.007679 | 0.2172 | 5.42 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.498** | 0.3105 | 9.297 | 5.84 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **1.622e-04** | 7.466e-05 | 6.436e-04 | 3.11 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **1.384e-05** | 3.753e-06 | 1.445e-04 | 6.92 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **0.00118** | 4.705e-04 | 0.005315 | 3.55 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **9.460e-12** | 3.850e-12 | 8.927e-11 | 4.82 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.287e-11** | 3.738e-12 | 1.053e-10 | 5.7 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.233e-11** | 8.125e-12 | 1.855e-10 | 5.03 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.361e-10** | 3.007e-10 | 5.524e-09 | 4.54 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.274e-11** | 1.999e-11 | 4.230e-10 | 4.75 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **8.088e-10** | 3.244e-10 | 5.944e-09 | 4.51 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.0179** | 0.002375 | 0.2402 | 10.7 | | Land use | Soil quality index | pt (soil quality index) | **0.2821** | 0.07574 | 2.076 | 5.63 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **1.654e-08** | 3.535e-09 | 9.519e-08 | 5.36 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **7.009e-04** | 2.817e-04 | 0.003276 | 3.57 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **8.024** | 1.717 | 40.41 | 5.24 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **1.105e-07** | 3.205e-08 | 7.917e-07 | 5.26 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.004929** | -24.94 | 14.03 | — | Climate change 0.4798 kg CO2 eq per kWh. Main contributors: Natural gas, burned in power plant or heat plant 100 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Natural gas, burned in power plant or heat plant 100 %. Most sensitive exchanges (Section 6.3): Natural gas, burned in power plant or heat plant [NL] (-17.0 / +20.5 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh: ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 3.524e-04 | 3.513e-04 | 1.003 | | Climate change-Biogenic | 2.535e-04 | 2.535e-04 | 1.000 | | Climate change-Fossil | 0.4795 | 0.4795 | 1.000 | | Climate change-Land use and land use change | 3.454e-05 | 3.454e-05 | 1.000 | | Climate change | 0.4798 | 0.4798 | 1.000 | | EF-particulate Matter | 1.431e-09 | 1.431e-09 | 1.000 | | Ecotoxicity, freshwater_inorganics | 1.465 | 1.466 | 0.999 | | Ecotoxicity, freshwater_organics | 0.03339 | 0.0332 | 1.006 | | Ecotoxicity, freshwater | 1.498 | 1.499 | 0.999 | | Eutrophication marine | 1.622e-04 | 1.622e-04 | 1.000 | | Eutrophication, freshwater | 1.384e-05 | 1.384e-05 | 1.000 | | Eutrophication, terrestrial | 0.00118 | 0.001627 | 0.725 | | Human toxicity, cancer_inorganics | 9.460e-12 | 9.174e-12 | 1.031 | | Human toxicity, cancer_organics | 1.287e-11 | 1.287e-11 | 1.000 | | Human toxicity, cancer | 2.233e-11 | 2.205e-11 | 1.013 | | Human toxicity, non-cancer_inorganics | 7.361e-10 | 7.264e-10 | 1.013 | | Human toxicity, non-cancer_organics | 7.274e-11 | 7.271e-11 | 1.000 | | Human toxicity, non-cancer | 8.088e-10 | 7.991e-10 | 1.012 | | Ionising radiation, human health | 0.0179 | 0.0179 | 1.000 | | Land use | 0.2821 | 0.4075 | 0.692 | | Ozone depletion | 1.654e-08 | 1.654e-08 | 1.000 | | Photochemical ozone formation - human health | 7.009e-04 | 7.009e-04 | 1.000 | | Resource use, fossils | 8.024 | 8.024 | 1.000 | | Resource use, minerals and metals | 1.105e-07 | 7.997e-08 | 1.382 | | Water use | 0.004929 | 0.005062 | 0.974 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.4798 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 599.9 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Natural gas, burned in power plant or heat plant [NL] | 6.72 MJ | ×0.83 / ×1.21 | lognormal, GSD² 1.21 | -17.0 / +20.5 | 20.5 (Climate change-Land use and land use change) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== ^ Source ^ Scope ^ Value ^ This dataset ^ Ratio ^ Note ^ | bafu | Electricity, natural gas, at power plant [CZ] | 0.4477 kg CO2 eq | 0.4798 | 1.07 | same dataset name, other location | | bafu | Electricity, natural gas, at power plant [GB] | 0.4529 kg CO2 eq | 0.4798 | 1.06 | same dataset name, other location | | bafu | Electricity, natural gas, at power plant [IE] | 0.4658 kg CO2 eq | 0.4798 | 1.03 | same dataset name, other location | | bafu | Electricity, natural gas, at power plant [KR] | 0.4731 kg CO2 eq | 0.4798 | 1.01 | same dataset name, other location | | bafu | Electricity, natural gas, at power plant [FR] | 0.4741 kg CO2 eq | 0.4798 | 1.01 | same dataset name, other location | | bafu | Electricity, natural gas, at power plant [SI] | 0.7886 kg CO2 eq | 0.4798 | 0.61 | same dataset name, other location | | bafu | Electricity, natural gas, at power plant [BG] | 0.8322 kg CO2 eq | 0.4798 | 0.58 | same dataset name, other location | | bafu | Electricity, natural gas, at power plant [HR] | 0.9012 kg CO2 eq | 0.4798 | 0.53 | same dataset name, other location | | bafu | Electricity, natural gas, at power plant [FI] | 1.117 kg CO2 eq | 0.4798 | 0.43 | same dataset name, other location | | bafu | Electricity, natural gas, at power plant [RU] | 1.334 kg CO2 eq | 0.4798 | 0.36 | same dataset name, other location | ==== Conclusions and limitations ==== GWP100 0.4798 kg CO2 eq per kWh (95 % interval 0.2688–1.115). Dominant contributors: Natural gas, burned in power plant or heat plant 100 %. Most sensitive: Natural gas, burned in power plant or heat plant [NL] (-17.0 / +20.5 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kWh | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.1e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 22/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 1/1 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.4798 in [0.2688, 1.115] | | time period declared | **PASS** | 2021-01-01+01:00/2023-12-31+01:00 | | geography is a known location code | **PASS** | NL | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - On behalf of the Federal Office for the Environment, Bern — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].