====== Electricity, photovoltaic mix slanted-roof, at plant — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:electricity_photovoltaic_mix_slanted_roof_at_plant__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity, photovoltaic mix slanted-roof, at plant [CH], per 1 kWh. EF v3.1 climate change 0.0272 kg CO2 eq (Monte Carlo 95 % interval 0.02236–0.1091). Main contributors: Electricity, PV, at 93 kWp slanted-roof, multi-Si, panel, mo… 24 %; Electricity, PV, at 93 kWp slanted-roof, multi-Si, laminated… 14 %; Electricity, PV, at 3kWp slanted-roof, multi-Si, panel, moun… 14 %; Electricity, PV, at 93 kWp slanted-roof, single-Si, panel, m… 13 %; Electricity, PV, at 3kWp slanted-roof, multi-Si, laminated, … 8 %; Electricity, PV, at 93 kWp slanted-roof, single-Si, laminate… 7 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Electricity, photovoltaic mix slanted-roof, at plant | | Dataset UUID / graph id | ''%%180412fe-7ef9-38c1-9dc4-c2563886f73b%%'' / ''%%activity:electricity_photovoltaic_mix_slanted_roof_at_plant__ch%%'' | | Reference product, unit | Electricity, photovoltaic mix slanted-roof, at plant, 1 kWh | | Location | CH | | Time period | 2005-01/2018-12 | | Category | energy supply, kbob recommendation / electricity, delivered via network | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== UUID: 180412fe-7ef9-38c1-9dc4-c2563886f73b This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kWh** of Electricity, photovoltaic mix slanted-roof, at plant (CH). All results are given per unit of the reference flow. ==== System boundary ==== This data set describes the share of the different slanted PV technologies ==== Technology ==== — ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electricity, PV, at 93 kWp slanted-roof, multi-Si, panel, mounted | technosphere | CH | 0.25077 | kWh | lognormal, GSD² 1.05 | — | 24.1 | █████ | | | Electricity, PV, at 93 kWp slanted-roof, multi-Si, laminated, integrated | technosphere | CH | 0.16588 | kWh | lognormal, GSD² 1.05 | — | 14.1 | ███ | | | Electricity, PV, at 3kWp slanted-roof, multi-Si, panel, mounted | technosphere | CH | 0.10808 | kWh | lognormal, GSD² 1.05 | — | 13.5 | ███ | | | Electricity, PV, at 93 kWp slanted-roof, single-Si, panel, mounted | technosphere | CH | 0.13281 | kWh | lognormal, GSD² 1.05 | — | 12.6 | ███ | | | Electricity, PV, at 3kWp slanted-roof, multi-Si, laminated, integrated | technosphere | CH | 0.071492 | kWh | lognormal, GSD² 1.05 | — | 8.1 | ██ | | | Electricity, PV, at 93 kWp slanted-roof, single-Si, laminated, integrated | technosphere | CH | 0.08785 | kWh | lognormal, GSD² 1.05 | — | 7.5 | █ | | | Electricity, PV, at 3kWp slanted-roof, single-Si, panel, mounted | technosphere | CH | 0.05724 | kWh | lognormal, GSD² 1.05 | — | 7.1 | █ | | | Electricity, PV, at 3kWp slanted-roof, single-Si, laminated, integrated | technosphere | CH | 0.037862 | kWh | lognormal, GSD² 1.05 | — | 4.3 | █ | | | Electricity, PV, at 3kWp slanted-roof, CIS, panel, mounted | technosphere | CH | 0.023964 | kWh | lognormal, GSD² 1.05 | — | 2.8 | █ | | | Electricity, PV, at 3kWp slanted-roof, CdTe, panel, mounted | technosphere | CH | 0.029009 | kWh | lognormal, GSD² 1.05 | — | 2.6 | █ | | | Electricity, PV, at 3kWp slanted-roof, CdTe, laminated, integrated | technosphere | CH | 0.019189 | kWh | lognormal, GSD² 1.05 | — | 1.7 | · | | | Electricity, PV, at 3kWp slanted-roof, CIS, laminated, integrated | technosphere | CH | 0.015852 | kWh | lognormal, GSD² 1.05 | — | 1.6 | · | | ==== Data quality ==== 0 of 12 direct exchanges carry a declared pedigree, 12 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Rolf Frischknecht (TREEZE); data entry: Rolf Frischknecht (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | none | | sampling procedure | unknown | | production volume | unknown | | uncertainty adjustments | none | | validation details | 12.09.2023 | | time period comment | Time of publications. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **1.194e-04** | 1.063e-04 | 4.344e-04 | 2.07 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.249e-04** | 8.441e-05 | 7.107e-04 | 2.95 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.02706** | 0.02225 | 0.1087 | 2.24 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.742e-05** | 1.449e-05 | 6.417e-05 | 2.12 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.0272** | 0.02236 | 0.1091 | 2.24 | | EF-particulate Matter | Impact on human health | disease incidence | **9.860e-10** | 8.925e-10 | 9.025e-09 | 3.2 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.1658** | 0.1487 | 0.817 | 2.43 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.003539** | 0.003341 | 0.01471 | 2.14 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.1693** | 0.1521 | 0.832 | 2.42 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **3.484e-05** | 2.949e-05 | 1.423e-04 | 2.26 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **2.429e-05** | 1.901e-05 | 1.681e-04 | 3.02 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **2.534e-04** | 2.200e-04 | 0.001019 | 2.17 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.166e-11** | 1.250e-11 | 6.394e-11 | 2.27 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.343e-12** | 6.024e-12 | 3.336e-11 | 2.36 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.901e-11** | 1.943e-11 | 9.230e-11 | 2.17 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.137e-10** | 8.022e-10 | 3.460e-09 | 2.09 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.448e-11** | 3.049e-11 | 1.082e-10 | 1.91 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **7.482e-10** | 8.386e-10 | 3.538e-09 | 2.07 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.006736** | 0.002611 | 0.07903 | 5.73 | | Land use | Soil quality index | pt (soil quality index) | **0.199** | 0.1725 | 0.8976 | 2.34 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **1.019e-09** | 8.994e-10 | 4.102e-09 | 2.14 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **8.601e-05** | 7.670e-05 | 3.386e-04 | 2.14 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.3653** | 0.3089 | 1.491 | 2.26 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **2.578e-06** | 2.239e-06 | 5.920e-06 | 1.65 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.01428** | -9.871 | 5.726 | — | Climate change 0.0272 kg CO2 eq per kWh. Main contributors: Electricity, PV, at 93 kWp slanted-roof, multi-Si, panel, mo… 24 %; Electricity, PV, at 93 kWp slanted-roof, multi-Si, laminated… 14 %; Electricity, PV, at 3kWp slanted-roof, multi-Si, panel, moun… 14 %; Electricity, PV, at 93 kWp slanted-roof, single-Si, panel, m… 13 %; Electricity, PV, at 3kWp slanted-roof, multi-Si, laminated, … 8 %; Electricity, PV, at 93 kWp slanted-roof, single-Si, laminate… 7 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electricity, PV, at 93 kWp slanted-roof, multi-Si, panel, mo… 24 %; Electricity, PV, at 93 kWp slanted-roof, multi-Si, laminated… 14 %; Electricity, PV, at 3kWp slanted-roof, multi-Si, panel, moun… 14 %; Electricity, PV, at 93 kWp slanted-roof, single-Si, panel, m… 13 %; Electricity, PV, at 3kWp slanted-roof, multi-Si, laminated, … 8 %; Electricity, PV, at 93 kWp slanted-roof, single-Si, laminate… 7 %. Most sensitive exchanges (Section 6.3): Electricity, PV, at 93 kWp slanted-roof, multi-Si, panel, mounted [CH] (-1.1 / +1.2 %); Electricity, PV, at 93 kWp slanted-roof, multi-Si, laminated, integrated [CH] (-0.7 / +0.7 %); Electricity, PV, at 3kWp slanted-roof, multi-Si, panel, mounted [CH] (-0.6 / +0.7 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh: ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 1.194e-04 | 1.259e-04 | 0.948 | | Climate change-Biogenic | 1.249e-04 | 1.249e-04 | 1.000 | | Climate change-Fossil | 0.02706 | 0.02706 | 1.000 | | Climate change-Land use and land use change | 1.742e-05 | 1.742e-05 | 1.000 | | Climate change | 0.0272 | 0.0272 | 1.000 | | EF-particulate Matter | 9.860e-10 | 9.860e-10 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.1658 | 0.1694 | 0.979 | | Ecotoxicity, freshwater_organics | 0.003539 | 0.002955 | 1.197 | | Ecotoxicity, freshwater | 0.1693 | 0.1717 | 0.986 | | Eutrophication marine | 3.484e-05 | 3.483e-05 | 1.000 | | Eutrophication, freshwater | 2.429e-05 | 2.429e-05 | 1.000 | | Eutrophication, terrestrial | 2.534e-04 | 2.623e-04 | 0.966 | | Human toxicity, cancer_inorganics | 1.166e-11 | 1.159e-11 | 1.006 | | Human toxicity, cancer_organics | 7.343e-12 | 7.342e-12 | 1.000 | | Human toxicity, cancer | 1.901e-11 | 1.894e-11 | 1.004 | | Human toxicity, non-cancer_inorganics | 7.137e-10 | 7.097e-10 | 1.006 | | Human toxicity, non-cancer_organics | 3.448e-11 | 3.445e-11 | 1.001 | | Human toxicity, non-cancer | 7.482e-10 | 7.441e-10 | 1.005 | | Ionising radiation, human health | 0.006736 | 0.006736 | 1.000 | | Land use | 0.199 | 0.1621 | 1.228 | | Ozone depletion | 1.019e-09 | 1.019e-09 | 1.000 | | Photochemical ozone formation - human health | 8.601e-05 | 8.601e-05 | 1.000 | | Resource use, fossils | 0.3653 | 0.3654 | 1.000 | | Resource use, minerals and metals | 2.578e-06 | 2.564e-06 | 1.006 | | Water use | 0.01428 | 0.01419 | 1.006 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.02718 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 70.64 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Electricity, PV, at 93 kWp slanted-roof, multi-Si, panel, mounted [CH] | 0.2508 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -1.1 / +1.2 | 1.3 (Ionising radiation, human health) | | Electricity, PV, at 93 kWp slanted-roof, multi-Si, laminated, integrated [CH] | 0.1659 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.7 / +0.7 | 0.7 (Land use) | | Electricity, PV, at 3kWp slanted-roof, multi-Si, panel, mounted [CH] | 0.1081 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.6 / +0.7 | 1.1 (Resource use, minerals and metals) | | Electricity, PV, at 93 kWp slanted-roof, single-Si, panel, mounted [CH] | 0.1328 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.6 / +0.6 | 1.2 (Water use) | | Electricity, PV, at 3kWp slanted-roof, multi-Si, laminated, integrated [CH] | 0.07149 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.4 / +0.4 | 0.8 (Resource use, minerals and metals) | | Electricity, PV, at 93 kWp slanted-roof, single-Si, laminated, integrated [CH] | 0.08785 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.3 / +0.4 | 0.8 (Water use) | | Electricity, PV, at 3kWp slanted-roof, single-Si, panel, mounted [CH] | 0.05724 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.3 / +0.3 | 0.6 (Resource use, minerals and metals) | | Electricity, PV, at 3kWp slanted-roof, single-Si, laminated, integrated [CH] | 0.03786 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.2 / +0.2 | 0.4 (Resource use, minerals and metals) | | Electricity, PV, at 3kWp slanted-roof, CIS, panel, mounted [CH] | 0.02396 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.1 / +0.1 | 0.5 (Ozone depletion) | | Electricity, PV, at 3kWp slanted-roof, CdTe, panel, mounted [CH] | 0.02901 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.1 / +0.1 | 0.3 (Resource use, minerals and metals) | | Electricity, PV, at 3kWp slanted-roof, CdTe, laminated, integrated [CH] | 0.01919 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.1 / +0.1 | 0.2 (Resource use, minerals and metals) | | Electricity, PV, at 3kWp slanted-roof, CIS, laminated, integrated [CH] | 0.01585 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.1 / +0.1 | 0.3 (Ozone depletion) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.0272 kg CO2 eq per kWh (95 % interval 0.02236–0.1091). Dominant contributors: Electricity, PV, at 93 kWp slanted-roof, multi-Si, panel, mo… 24 %; Electricity, PV, at 93 kWp slanted-roof, multi-Si, laminated… 14 %; Electricity, PV, at 3kWp slanted-roof, multi-Si, panel, moun… 14 %; Electricity, PV, at 93 kWp slanted-roof, single-Si, panel, m… 13 %; Electricity, PV, at 3kWp slanted-roof, multi-Si, laminated, … 8 %; Electricity, PV, at 93 kWp slanted-roof, single-Si, laminate… 7 %. Most sensitive: Electricity, PV, at 93 kWp slanted-roof, multi-Si, panel, mounted [CH] (-1.1 / +1.2 %); Electricity, PV, at 93 kWp slanted-roof, multi-Si, laminated, integrated [CH] (-0.7 / +0.7 %); Electricity, PV, at 3kWp slanted-roof, multi-Si, panel, mounted [CH] (-0.6 / +0.7 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kWh | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.9e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 22/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 12/12 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.0272 in [0.02236, 0.1091] | | time period declared | **PASS** | 2005-01/2018-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Report — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].