====== Disposal, ventilation system, Altersheim Dorflinde — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:disposal_ventilation_system_altersheim_dorflinde__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Disposal, ventilation system, Altersheim Dorflinde [CH], per 1 p. EF v3.1 climate change 5137 kg CO2 eq (Monte Carlo 95 % interval 4782–6169). Main contributors: Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 19 %; Disposal, ventilation unit 6700 m3/h, w. cross plate heat ex… 18 %; Disposal, ventilation unit 13000 m3/h, w. circuit connected … 12 %; Disposal, ventilation unit 6700 m3/h, w. circuit connected h… 10 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 7 %; Disposal, ventilation duct, steel, zinc coated, s= 0.75mm 7 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Disposal, ventilation system, Altersheim Dorflinde | | Dataset UUID / graph id | ''%%1907244c-1647-4054-b5e9-429ca99b9b6a%%'' / ''%%activity:disposal_ventilation_system_altersheim_dorflinde__ch%%'' | | Reference product, unit | Disposal, ventilation system, Altersheim Dorflinde, 1 p | | Location | CH — Specific to the technology mix encountered in sorting plants in Switzerland. | | Time period | 2014-01/2014-12 | | Category | waste management / building demolition | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Disposal of a ventilation system for a residential care home with apartments, kitchen, cafe/restaurant, multi-purpose hall, wellness area and laundry. The inventory is based on a building with a total heated gross floor area of 9844 m2 and a total nominal air flow of 34460 m3/h, total weight of the components: 11910 kg/Unit, building with a specific air flow rate of 3.5 m3/h per m2 heated gross floor area. Data from call of bid including components for air handling units, ducts including insulation, air valves, roof-hoods, dampers, fire dampers, silencers. The data represent a ductwork mainly made of galvanized steel and includes air handling units mainly with heat recovery. System with central air handling units. Building without ground heat exchanger.; UUID: 1907244c-1647-4054-b5e9-429ca99b9b6a This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Disposal, ventilation system, Altersheim Dorflinde (CH). All results are given per unit of the reference flow. ==== System boundary ==== Transport to dismantling facilities, machines for handling in sorting plant, electricity demand for sorting plant, final disposal of waste material. Cut-off to recycling for metals. ==== Technology ==== Disposal to a sorting plant assumed. Metal pieces, copper in cables and electronic devices are recycled, plastic parts are incinerated, inert wastes (e.g. rock wool) are landfilled. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger | technosphere | CH | 3.223 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 18.7 | ████ | | | Disposal, ventilation unit 6700 m3/h, w. cross plate heat excanger | technosphere | CH | 1.775 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 18.1 | ████ | | | Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger | technosphere | CH | 0.751 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 12.2 | ██ | | | Disposal, ventilation unit 6700 m3/h, w. circuit connected heat exchanger | technosphere | CH | 0.996 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 9.6 | ██ | | | Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil | technosphere | CH | 1463 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 7.1 | █ | | | Disposal, ventilation duct, steel, zinc coated, s= 0.75mm | technosphere | CH | 1843.1 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 6.6 | █ | | | Disposal, ventilation system, Altersheim Dorflinde, various components | technosphere | CH | 1 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 5.9 | █ | | | Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm | technosphere | CH | 763.94 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 4.9 | █ | | | Disposal, ventilation duct, steel, zinc coated, s= 1.0mm | technosphere | CH | 1076.6 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 4.0 | █ | | | Disposal, ventilation duct, steel, zinc coated, s= 0.62mm | technosphere | CH | 1085.7 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 3.8 | █ | | | Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil | technosphere | CH | 1110 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 3.5 | █ | | | Disposal, ventilation duct, steel, zinc coated, s= 0.87mm | technosphere | CH | 794.03 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 2.9 | █ | | | Disposal, flexible duct, aluminum/PET, DN of 125 | technosphere | CH | 242.34 | m | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.3 | · | | | Disposal, ventilation duct, steel, zinc coated, s= 1.25mm | technosphere | CH | 158.27 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.6 | · | | | Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm | technosphere | CH | 70.915 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.5 | · | | | Disposal, thermal insulation, 100mm, 40kg/m3, alumium cladding | technosphere | CH | 80 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · | | | Disposal, ventilation system, Altersheim Dorflinde, special components | technosphere | CH | 1 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · | | | Disposal, spiral-seam duct, steel, zinc coated, s= 0.8mm | technosphere | CH | 6.0319 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | | | Disposal, ventilation duct, steel, zinc coated, s= 1.5mm | technosphere | CH | 7.1175 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | | | Disposal, spiral-seam duct, stainless steel, s= 0.8mm | technosphere | CH | 1.885 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | | ==== Data quality ==== 20 of 20 direct exchanges carry a declared pedigree, 20 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.2 · completeness 4.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 5.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU) | | extrapolations | none | | sampling procedure | Waste-specific calculation based on production input data | | production volume | na | | uncertainty adjustments | none | | time period comment | Amount of material investigated in 2013. Disposal technology mix as used in late 1990ies | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **1.48** | 1.348 | 2.904 | 1.49 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.085** | 0.874 | 2.075 | 1.56 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **5136** | 4780 | 6167 | 1.14 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.188** | 0.1634 | 0.2845 | 1.33 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **5137** | 4782 | 6169 | 1.14 | | EF-particulate Matter | Impact on human health | disease incidence | **1.111e-04** | 7.343e-05 | 2.324e-04 | 1.79 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.026e+04** | 1.613e+04 | 3.188e+04 | 1.42 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **84.58** | 73.28 | 157.6 | 1.5 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.035e+04** | 1.622e+04 | 3.199e+04 | 1.42 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **1.699** | 1.393 | 3.652 | 1.66 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **0.8486** | 0.1541 | 25.4 | 14.6 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **12.03** | 9.595 | 27.95 | 1.76 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.406e-07** | 2.436e-07 | 9.832e-07 | 1.98 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.085e-07** | 9.598e-08 | 1.658e-07 | 1.33 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **3.492e-07** | 3.649e-07 | 1.103e-06 | 1.72 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.506e-05** | 1.495e-05 | 5.318e-05 | 1.92 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **8.565e-07** | 6.790e-07 | 1.331e-06 | 1.41 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.591e-05** | 1.570e-05 | 5.421e-05 | 1.88 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **184.4** | 70.96 | 1081 | 4.16 | | Land use | Soil quality index | pt (soil quality index) | **7109** | 628.2 | 1.611e+04 | — | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **2.011e-05** | 1.816e-05 | 3.322e-05 | 1.34 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **4.692** | 3.87 | 9.944 | 1.62 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **9030** | 8341 | 1.493e+04 | 1.32 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.001232** | 0.00105 | 0.002433 | 1.53 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **671.5** | -7.856e+04 | 4.082e+04 | — | Climate change 5137 kg CO2 eq per p. Main contributors: Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 19 %; Disposal, ventilation unit 6700 m3/h, w. cross plate heat ex… 18 %; Disposal, ventilation unit 13000 m3/h, w. circuit connected … 12 %; Disposal, ventilation unit 6700 m3/h, w. circuit connected h… 10 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 7 %; Disposal, ventilation duct, steel, zinc coated, s= 0.75mm 7 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 19 %; Disposal, ventilation unit 6700 m3/h, w. cross plate heat ex… 18 %; Disposal, ventilation unit 13000 m3/h, w. circuit connected … 12 %; Disposal, ventilation unit 6700 m3/h, w. circuit connected h… 10 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 7 %; Disposal, ventilation duct, steel, zinc coated, s= 0.75mm 7 %. Most sensitive exchanges (Section 6.3): Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger [CH] (-3.8 / +4.8 %); Disposal, ventilation unit 6700 m3/h, w. cross plate heat excanger [CH] (-3.7 / +4.6 %); Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger [CH] (-2.5 / +3.1 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 1.48 | 3.18 | 0.465 | | Climate change-Biogenic | 1.085 | 1.085 | 1.000 | | Climate change-Fossil | 5136 | 5136 | 1.000 | | Climate change-Land use and land use change | 0.188 | 0.188 | 1.000 | | Climate change | 5137 | 5137 | 1.000 | | EF-particulate Matter | 1.111e-04 | 1.111e-04 | 1.000 | | Ecotoxicity, freshwater_inorganics | 2.026e+04 | 2.119e+04 | 0.956 | | Ecotoxicity, freshwater_organics | 84.58 | 84.3 | 1.003 | | Ecotoxicity, freshwater | 2.035e+04 | 2.127e+04 | 0.957 | | Eutrophication marine | 1.699 | 1.699 | 1.000 | | Eutrophication, freshwater | 0.8486 | 0.8486 | 1.000 | | Eutrophication, terrestrial | 12.03 | 15.25 | 0.789 | | Human toxicity, cancer_inorganics | 2.406e-07 | 2.398e-07 | 1.003 | | Human toxicity, cancer_organics | 1.085e-07 | 1.085e-07 | 1.000 | | Human toxicity, cancer | 3.492e-07 | 3.484e-07 | 1.002 | | Human toxicity, non-cancer_inorganics | 1.506e-05 | 1.498e-05 | 1.005 | | Human toxicity, non-cancer_organics | 8.565e-07 | 8.565e-07 | 1.000 | | Human toxicity, non-cancer | 1.591e-05 | 1.583e-05 | 1.005 | | Ionising radiation, human health | 184.4 | 184.4 | 1.000 | | Land use | 7109 | 4209 | 1.689 | | Ozone depletion | 2.011e-05 | 2.011e-05 | 1.000 | | Photochemical ozone formation - human health | 4.692 | 4.692 | 1.000 | | Resource use, fossils | 9030 | 9031 | 1.000 | | Resource use, minerals and metals | 0.001232 | 0.001053 | 1.170 | | Water use | 671.5 | 676.6 | 0.992 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 5137 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 9.335e+06 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger [CH] | 3.223 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -3.8 / +4.8 | 6.3 (Water use) | | Disposal, ventilation unit 6700 m3/h, w. cross plate heat excanger [CH] | 1.775 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -3.7 / +4.6 | 6.6 (Water use) | | Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger [CH] | 0.751 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -2.5 / +3.1 | 5.1 (Water use) | | Disposal, ventilation unit 6700 m3/h, w. circuit connected heat exchanger [CH] | 0.996 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -1.9 / +2.4 | 3.6 (Water use) | | Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil [CH] | 1463 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -1.4 / +1.7 | 17.5 (Eutrophication, freshwater) | | Disposal, ventilation duct, steel, zinc coated, s= 0.75mm [CH] | 1843 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -1.3 / +1.5 | 3.5 (Ionising radiation, human health) | | Disposal, ventilation system, Altersheim Dorflinde, various components [CH] | 1 p | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -1.1 / +1.4 | 2.6 (Ionising radiation, human health) | | Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm [CH] | 763.9 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.9 / +1.2 | 1.2 (Climate change-Fossil) | | Disposal, ventilation duct, steel, zinc coated, s= 1.0mm [CH] | 1077 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.8 / +0.9 | 2.7 (Ionising radiation, human health) | | Disposal, ventilation duct, steel, zinc coated, s= 0.62mm [CH] | 1086 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.7 / +0.9 | 1.7 (Ionising radiation, human health) | | Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil [CH] | 1110 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.7 / +0.8 | 2.7 (Eutrophication, freshwater) | | Disposal, ventilation duct, steel, zinc coated, s= 0.87mm [CH] | 794 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.6 / +0.7 | 1.8 (Ionising radiation, human health) | | Disposal, flexible duct, aluminum/PET, DN of 125 [CH] | 242.3 m | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.2 / +0.3 | 0.3 (Human toxicity, non-cancer_inorganics) | | Disposal, ventilation duct, steel, zinc coated, s= 1.25mm [CH] | 158.3 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.1 / +0.1 | 0.5 (Ionising radiation, human health) | | Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm [CH] | 70.92 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.1 / +0.1 | 0.1 (Climate change-Fossil) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 5137 kg CO2 eq per p (95 % interval 4782–6169). Dominant contributors: Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 19 %; Disposal, ventilation unit 6700 m3/h, w. cross plate heat ex… 18 %; Disposal, ventilation unit 13000 m3/h, w. circuit connected … 12 %; Disposal, ventilation unit 6700 m3/h, w. circuit connected h… 10 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 7 %; Disposal, ventilation duct, steel, zinc coated, s= 0.75mm 7 %. Most sensitive: Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger [CH] (-3.8 / +4.8 %); Disposal, ventilation unit 6700 m3/h, w. cross plate heat excanger [CH] (-3.7 / +4.6 %); Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger [CH] (-2.5 / +3.1 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.9e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 20/20 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 5137 in [4782, 6169] | | time period declared | **PASS** | 2014-01/2014-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].