====== Electricity, production mix ZA — ZA ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:electricity_production_mix_za__za|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity, production mix ZA [ZA], per 1 kWh. EF v3.1 climate change 1.012 kg CO2 eq (Monte Carlo 95 % interval 0.9425–1.113). Main contributors: Electricity, hard coal, at power plant 98 %; Electricity, hydropower, at pumped storage power plant 2 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Electricity, production mix ZA | | Dataset UUID / graph id | ''%%1d9ed2e5-7666-3719-a728-45f43cb44c00%%'' / ''%%activity:electricity_production_mix_za__za%%'' | | Reference product, unit | Electricity, production mix ZA, 1 kWh | | Location | ZA — Data apply to public and self producers in South Africa. | | Time period | 2006-01/2009-12 | | Category | electricity / production mix | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Electricity domestic net production shares are based on IEA statistics for the year 2008.; UUID: 1d9ed2e5-7666-3719-a728-45f43cb44c00 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kWh** of Electricity, production mix ZA (ZA). All results are given per unit of the reference flow. ==== System boundary ==== It includes the shares of domestic electricity production by technology at the busbar. It does not include transformation, transport nor distribution losses. Photovoltaic electricity modelled with country-specific dataset that was created within project 174; Philippe Stolz, June 2020. ==== Technology ==== No technology description is provided because the dataset just describes the power plant portfolio of the respective country using current (2004) average technology per energy carrier. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electricity, hard coal, at power plant | technosphere | ENTSO-E | 0.92737 | kWh | lognormal, GSD² 1.05 | (1,1,1,3,1,1) | 98.3 | ████████████████████ | | | Electricity, hydropower, at pumped storage power plant | technosphere | ZA | 0.011859 | kWh | lognormal, GSD² 1.05 | (1,1,1,3,1,1) | 1.5 | · | | | Electricity, oil, at power plant | technosphere | UCTE | 5.5073e-04 | kWh | lognormal, GSD² 1.05 | (1,1,1,3,1,1) | 0.1 | · | | | Electricity, nuclear, at power plant pressure water reactor | technosphere | UCTE | 0.053407 | kWh | lognormal, GSD² 1.05 | (1,1,1,3,1,1) | 0.0 | · | | | Electricity, hydropower, at reservoir power plant | technosphere | BR | 0.0055809 | kWh | lognormal, GSD² 1.05 | (1,1,1,3,1,1) | 0.0 | · | | | Electricity, at cogen 1MWth, wood chips, allocation exergy | technosphere | CH | 9.9747e-04 | kWh | lognormal, GSD² 1.05 | (1,1,1,3,1,1) | 0.0 | · | | | Electricity, at wind farm | technosphere | RER | 1.3981e-04 | kWh | lognormal, GSD² 1.05 | (1,1,1,3,1,1) | 0.0 | · | | | Electricity, production mix photovoltaic, at plant | technosphere | ZA | 9.0354e-05 | kWh | lognormal, GSD² 1.05 | (1,1,1,3,1,1) | 0.0 | · | | ==== Data quality ==== 8 of 8 direct exchanges carry a declared pedigree, 8 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 1.0 · completeness 1.0 · temporal 1.0 · geographical 3.0 · technological 1.0 · sample size 1.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: René Itten (ZHAW); data entry: René Itten (ZHAW); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | none | | sampling procedure | Statistical data | | production volume | 258 TWh | | uncertainty adjustments | none | | validation details | Proof reading validation: automatic validation in Excel; Other validation: Z:\ESU-Docs\Projekte laufend\401 Update Strommix v3.0\EcoSpold_Afrika[401-electricity-mix-south-africa-ZA-v1.0.xlsx]X-Process; | | time period comment | Time period of statistics used (2008). | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **0.001633** | 0.0015 | 0.001971 | 1.15 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **6.823e-04** | 4.876e-04 | 0.001468 | 1.76 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.01** | 0.9414 | 1.111 | 1.09 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **3.498e-04** | 2.361e-04 | 5.899e-04 | 1.6 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.012** | 0.9425 | 1.113 | 1.09 | | EF-particulate Matter | Impact on human health | disease incidence | **1.198e-08** | 1.099e-08 | 1.645e-08 | 1.23 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.248** | 1.842 | 3.592 | 1.42 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.006141** | 0.005891 | 0.01101 | 1.4 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.254** | 1.849 | 3.599 | 1.41 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **4.802e-04** | 4.303e-04 | 6.062e-04 | 1.2 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **4.395e-04** | 1.687e-04 | 0.001801 | 3.38 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **0.003223** | 0.002781 | 0.004532 | 1.29 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **9.854e-11** | 6.927e-11 | 4.349e-10 | 2.58 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **4.592e-11** | 3.956e-11 | 7.066e-11 | 1.35 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.445e-10** | 1.196e-10 | 4.914e-10 | 2.08 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.134e-09** | 4.178e-09 | 3.296e-08 | 2.83 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.495e-10** | 2.043e-10 | 3.579e-10 | 1.33 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **7.384e-09** | 4.458e-09 | 3.319e-08 | 2.76 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.1137** | 0.03921 | 0.6594 | 4.24 | | Land use | Soil quality index | pt (soil quality index) | **1.906** | 1.566 | 4.033 | 1.62 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **1.815e-09** | 1.657e-09 | 2.990e-09 | 1.35 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **0.001166** | 0.00105 | 0.001513 | 1.21 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **10.79** | 9.711 | 12.82 | 1.15 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **9.159e-08** | 8.553e-08 | 2.014e-07 | 1.52 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.1052** | -22.47 | 11.69 | — | Climate change 1.012 kg CO2 eq per kWh. Main contributors: Electricity, hard coal, at power plant 98 %; Electricity, hydropower, at pumped storage power plant 2 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electricity, hard coal, at power plant 98 %; Electricity, hydropower, at pumped storage power plant 2 %. Most sensitive exchanges (Section 6.3): Electricity, hard coal, at power plant [ENTSO-E] (-4.9 / +5.2 %); Electricity, hydropower, at pumped storage power plant [ZA] (-0.1 / +0.1 %); Electricity, oil, at power plant [UCTE] (-0.0 / +0.0 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh: ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 0.001633 | 0.001762 | 0.926 | | Climate change-Biogenic | 6.823e-04 | 6.823e-04 | 1.000 | | Climate change-Fossil | 1.01 | 1.01 | 1.000 | | Climate change-Land use and land use change | 3.498e-04 | 3.498e-04 | 1.000 | | Climate change | 1.012 | 1.012 | 1.000 | | EF-particulate Matter | 1.198e-08 | 1.198e-08 | 1.000 | | Ecotoxicity, freshwater_inorganics | 2.248 | 2.319 | 0.969 | | Ecotoxicity, freshwater_organics | 0.006141 | 0.006112 | 1.005 | | Ecotoxicity, freshwater | 2.254 | 2.325 | 0.969 | | Eutrophication marine | 4.802e-04 | 4.802e-04 | 1.000 | | Eutrophication, freshwater | 4.395e-04 | 4.395e-04 | 1.000 | | Eutrophication, terrestrial | 0.003223 | 0.004506 | 0.715 | | Human toxicity, cancer_inorganics | 9.854e-11 | 9.858e-11 | 1.000 | | Human toxicity, cancer_organics | 4.592e-11 | 4.592e-11 | 1.000 | | Human toxicity, cancer | 1.445e-10 | 1.445e-10 | 1.000 | | Human toxicity, non-cancer_inorganics | 7.134e-09 | 7.110e-09 | 1.003 | | Human toxicity, non-cancer_organics | 2.495e-10 | 2.495e-10 | 1.000 | | Human toxicity, non-cancer | 7.384e-09 | 7.360e-09 | 1.003 | | Ionising radiation, human health | 0.1137 | 0.1137 | 1.000 | | Land use | 1.906 | 1.555 | 1.226 | | Ozone depletion | 1.815e-09 | 1.815e-09 | 1.000 | | Photochemical ozone formation - human health | 0.001166 | 0.001166 | 1.000 | | Resource use, fossils | 10.79 | 10.79 | 1.000 | | Resource use, minerals and metals | 9.159e-08 | 8.635e-08 | 1.061 | | Water use | 0.1052 | 0.153 | 0.688 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 1.012 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 1266 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Electricity, hard coal, at power plant [ENTSO-E] | 0.9274 kWh | ×0.95 / ×1.05 | lognormal, GSD² 1.05 | -4.9 / +5.2 | 5.3 (Human toxicity, non-cancer_inorganics) | | Electricity, hydropower, at pumped storage power plant [ZA] | 0.01186 kWh | ×0.95 / ×1.05 | lognormal, GSD² 1.05 | -0.1 / +0.1 | 2.0 (Climate change-Land use and land use change) | | Electricity, oil, at power plant [UCTE] | 5.507e-04 kWh | ×0.95 / ×1.05 | lognormal, GSD² 1.05 | -0.0 / +0.0 | 0.0 (Ecotoxicity, freshwater_organics) | | Electricity, nuclear, at power plant pressure water reactor [UCTE] | 0.05341 kWh | ×0.95 / ×1.05 | lognormal, GSD² 1.05 | -0.0 / +0.0 | 3.9 (Ionising radiation, human health) | | Electricity, hydropower, at reservoir power plant [BR] | 0.005581 kWh | ×0.95 / ×1.05 | lognormal, GSD² 1.05 | -0.0 / +0.0 | 2.6 (Climate change-Land use and land use change) | | Electricity, at cogen 1MWth, wood chips, allocation exergy [CH] | 9.975e-04 kWh | ×0.95 / ×1.05 | lognormal, GSD² 1.05 | -0.0 / +0.0 | 0.2 (Land use) | | Electricity, at wind farm [RER] | 1.398e-04 kWh | ×0.95 / ×1.05 | lognormal, GSD² 1.05 | -0.0 / +0.0 | 0.0 (Resource use, minerals and metals) | | Electricity, production mix photovoltaic, at plant [ZA] | 9.035e-05 kWh | ×0.95 / ×1.05 | lognormal, GSD² 1.05 | -0.0 / +0.0 | 0.0 (Resource use, minerals and metals) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 1.012 kg CO2 eq per kWh (95 % interval 0.9425–1.113). Dominant contributors: Electricity, hard coal, at power plant 98 %; Electricity, hydropower, at pumped storage power plant 2 %. Most sensitive: Electricity, hard coal, at power plant [ENTSO-E] (-4.9 / +5.2 %); Electricity, hydropower, at pumped storage power plant [ZA] (-0.1 / +0.1 %); Electricity, oil, at power plant [UCTE] (-0.0 / +0.0 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kWh | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 5.9e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 20/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 8/8 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 1.012 in [0.9425, 1.113] | | time period declared | **PASS** | 2006-01/2009-12 | | geography is a known location code | **PASS** | ZA | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Itten, R., Frischknecht, R. (2012) Life Cycle Inventories of electricity mixes. Project reports. Volume: 401. ESU-services Ltd.. Uster, CH. Type: Separate publication First author: Itten, R. Other authors: Frischknecht, R. Year: 2012 Title of anthology: Project reports Place of publication: Uster, CH Publisher: ESU-services Ltd. Volume No: 401 — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].