====== Ventilation system, Pflegezentrum Witikon — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:ventilation_system_pflegezentrum_witikon__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Ventilation system, Pflegezentrum Witikon [CH], per 1 p. EF v3.1 climate change 4.923e+05 kg CO2 eq (Monte Carlo 95 % interval 4.787e+05–5.850e+05). Main contributors: Ventilation duct, steel, zinc coated, s= 0.75mm, at plant 15 %; Ventilation unit 13000 m3/h, w. circuit connected heat excha… 14 %; Ventilation duct, steel, zinc coated, s= 0.62mm, at plant 12 %; Ventilation duct, steel, zinc coated, s= 0.87mm, at plant 8 %; EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium fo… 5 %; Ventilation system, Pflegezentrum Witikon, various component… 5 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Ventilation system, Pflegezentrum Witikon | | Dataset UUID / graph id | ''%%22d75160-d40f-3e2b-b646-e614691124f2%%'' / ''%%activity:ventilation_system_pflegezentrum_witikon__ch%%'' | | Reference product, unit | Ventilation system, Pflegezentrum Witikon, 1 p | | Location | CH | | Time period | 2014-01/2014-12 | | Category | ventilation / production of components | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Production of a ventilation system for a residential care home with apartments, kitchen, cafe/restaurant, multi-purpose hall, laundry and car park. The inventory is based on a building with a total heated gross floor area of 11358 m2 and a total nominal air flow of 74580 m3/h, total weight of the components: 30520 kg/Unit, building with a specific air flow rate of 6.6 m3/h per m2 heated gross floor area. Data from call of bid including components for air handling units, ducts including insulation, air valves, roof-hoods, dampers, fire dampers, silencers. The data represent a ductwork mainly made of galvanized steel and includes air handling units mainly with heat recovery. System with central air handling units. Building without ground heat exchanger.; UUID: 22d75160-d40f-3e2b-b646-e614691124f2 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Ventilation system, Pflegezentrum Witikon (CH). All results are given per unit of the reference flow. ==== System boundary ==== Materials used for the production. Energy use for the different production steps and for heating the production building. Transport of raw materials to the plant. Estimation for infrastructure of the production site included. ==== Technology ==== Technology, materials and components used for ventilation systems in commercial and public buildings ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Ventilation duct, steel, zinc coated, s= 0.75mm, at plant | technosphere | CH | 2870.5 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 14.6 | ███ | | | Ventilation unit 13000 m3/h, w. circuit connected heat exchanger, at plant | technosphere | CH | 4.635 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 14.2 | ███ | | | Ventilation duct, steel, zinc coated, s= 0.62mm, at plant | technosphere | CH | 2832.2 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 11.6 | ██ | | | Ventilation duct, steel, zinc coated, s= 0.87mm, at plant | technosphere | CH | 1446.4 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 8.3 | ██ | | | EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil, at plant | technosphere | CH | 2735 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 5.4 | █ | | | Ventilation system, Pflegezentrum Witikon, various components | technosphere | CH | 1 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 4.6 | █ | | | Ventilation duct, steel, zinc coated, s= 1.0mm, at plant | technosphere | CH | 667.21 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 4.3 | █ | | | Thermal insulation, 30mm, 40kg/m3, reinforced alumium foil, at plant | technosphere | CH | 4730 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 3.8 | █ | | | Ventilation system, Pflegezentrum Witikon, special components | technosphere | CH | 1 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 3.6 | █ | | | Ventilation duct, steel, zinc coated, s= 1.5mm, at plant | technosphere | CH | 379.07 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 3.5 | █ | | | Silencer for ventilator unit 13000 m3/h, modular, at plant | technosphere | CH | 20.54 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 3.2 | █ | | | Spiral-seam duct, steel, zinc coated, s= 0.5mm, at plant | technosphere | CH | 868.65 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 2.7 | █ | | | Ventilation duct, steel, zinc coated, s= 1.25mm, at plant | technosphere | CH | 331.1 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 2.6 | █ | | | Thermal insulation, 100mm, 40kg/m3, alumium cladding, at plant | technosphere | CH | 735 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 2.5 | · | | | Ventilation duct, stainless steel, s= 1.25mm, at plant | technosphere | CH | 155.14 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 2.1 | · | | | Ventilation unit 6700 m3/h, w. circuit connected heat exchanger, at plant | technosphere | CH | 1 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 1.8 | · | | | Ventilation unit 3500 m3/h, w. cross plate heat excanger, at plant | technosphere | CH | 0.977 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 1.4 | · | | | Ventilation duct, stainless steel, s= 1.0mm, at plant | technosphere | CH | 119 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.3 | · | | | Ventilation unit 1800 m3/h, w. cross plate heat excanger, at plant | technosphere | CH | 1.378 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 1.3 | · | | | EI 60 fire insulation, 70mm, 120kg/m3, reinforced alumium foil, at plant | technosphere | CH | 485 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.2 | · | | | Ventilation duct, stainless steel, s= 1.5mm, at plant | technosphere | CH | 66.6 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.1 | · | | | Ventilator unit 13000 m3/h, modular, w. filter, without silencer, at plant | technosphere | CH | 1 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.9 | · | | | Ventilation unit 3500 m3/h, w. circuit connected heat exchanger, at plant | technosphere | CH | 0.717 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.8 | · | | | Silencer for ventilator unit 3500 m3/h, modular, at plant | technosphere | CH | 10.164 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.8 | · | | | Ventilator unit 3500 m3/h, modular, w. filter, without silencer, at plant | technosphere | CH | 1.694 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.6 | · | | | Ventilation duct, stainless steel, s= 0.87mm, at plant | technosphere | CH | 61 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.6 | · | | | Silencer for ventilator unit 6700 m3/h, modular, at plant, Device | technosphere | CH | 4 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.4 | · | | | Silencer for ventilator unit 1800 m3/h, modular, at plant, Device | technosphere | CH | 5.512 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.3 | · | | | Thermal insulation, 100mm, 40kg/m3, reinforced alumium foil, at plant | technosphere | CH | 174 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.3 | · | | | Ventilation duct, stainless steel, s= 0.62mm, at plant | technosphere | CH | 30 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.2 | · | | | Ventilation duct, stainless steel, s= 0.75mm, at plant | technosphere | CH | 10.6 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · | | | Spiral-seam duct, steel, zinc coated, s= 0.6mm, at plant | technosphere | CH | 6.0781 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | | ==== Data quality ==== 32 of 32 direct exchanges carry a declared pedigree, 32 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.34 · completeness 4.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 5.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU) | | extrapolations | none | | sampling procedure | Data from call of bids for a ventilation system of a specific building used. Data completed with information from literature and from manufacturers | | production volume | na | | uncertainty adjustments | none | | time period comment | Amount of material investigated in 2013. Process information partly from 2003 to 2012 | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **6486** | 4279 | 1.196e+04 | 1.7 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1733** | 1200 | 3688 | 1.76 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **4.903e+05** | 4.765e+05 | 5.825e+05 | 1.11 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **259.4** | 213.9 | 426.1 | 1.44 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **4.923e+05** | 4.787e+05 | 5.850e+05 | 1.11 | | EF-particulate Matter | Impact on human health | disease incidence | **0.07037** | 0.05304 | 0.1157 | 1.48 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.185e+06** | 2.148e+06 | 3.645e+06 | 1.33 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **5.656e+04** | 5.161e+04 | 1.241e+05 | 1.75 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.241e+06** | 2.216e+06 | 3.757e+06 | 1.33 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **535.8** | 482.6 | 766.6 | 1.27 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **300.2** | 220.3 | 1434 | 2.55 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **2.47e+04** | 1.466e+04 | 4.9e+04 | 1.86 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.928e-04** | 2.925e-04 | 6.805e-04 | 1.54 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.133e-04** | 1.863e-04 | 3.725e-04 | 1.43 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **5.060e-04** | 5.199e-04 | 9.540e-04 | 1.37 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **0.01964** | 0.01828 | 0.04905 | 1.66 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.542e-04** | 5.506e-04 | 0.001429 | 1.62 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **0.02039** | 0.01897 | 0.04986 | 1.64 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **1.365e+05** | 4.965e+04 | 8.245e+05 | 4.28 | | Land use | Soil quality index | pt (soil quality index) | **2.484e+06** | 2.428e+06 | 3.950e+06 | 1.28 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **0.01292** | 0.01157 | 0.02065 | 1.34 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **1493** | 1424 | 2256 | 1.27 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **5.891e+06** | 5.607e+06 | 8.054e+06 | 1.2 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **11.47** | -7.774 | 50.25 | — | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **6.119e+04** | -1.331e+08 | 6.520e+07 | — | Climate change 4.923e+05 kg CO2 eq per p. Main contributors: Ventilation duct, steel, zinc coated, s= 0.75mm, at plant 15 %; Ventilation unit 13000 m3/h, w. circuit connected heat excha… 14 %; Ventilation duct, steel, zinc coated, s= 0.62mm, at plant 12 %; Ventilation duct, steel, zinc coated, s= 0.87mm, at plant 8 %; EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium fo… 5 %; Ventilation system, Pflegezentrum Witikon, various component… 5 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Ventilation duct, steel, zinc coated, s= 0.75mm, at plant 15 %; Ventilation unit 13000 m3/h, w. circuit connected heat excha… 14 %; Ventilation duct, steel, zinc coated, s= 0.62mm, at plant 12 %; Ventilation duct, steel, zinc coated, s= 0.87mm, at plant 8 %; EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium fo… 5 %; Ventilation system, Pflegezentrum Witikon, various component… 5 %. Most sensitive exchanges (Section 6.3): Ventilation unit 13000 m3/h, w. circuit connected heat exchanger, at plant [CH] (-2.9 / +3.6 %); Ventilation duct, steel, zinc coated, s= 0.75mm, at plant [CH] (-2.8 / +3.4 %); Ventilation duct, steel, zinc coated, s= 0.62mm, at plant [CH] (-2.2 / +2.7 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 6486 | 6836 | 0.949 | | Climate change-Biogenic | 1733 | 1733 | 1.000 | | Climate change-Fossil | 4.903e+05 | 4.903e+05 | 1.000 | | Climate change-Land use and land use change | 259.4 | 259.4 | 1.000 | | Climate change | 4.923e+05 | 4.923e+05 | 1.000 | | EF-particulate Matter | 0.07037 | 0.07037 | 1.000 | | Ecotoxicity, freshwater_inorganics | 2.185e+06 | 2.203e+06 | 0.992 | | Ecotoxicity, freshwater_organics | 5.656e+04 | 5.459e+04 | 1.036 | | Ecotoxicity, freshwater | 2.241e+06 | 2.255e+06 | 0.994 | | Eutrophication marine | 535.8 | 535.8 | 1.000 | | Eutrophication, freshwater | 300.2 | 300.2 | 1.000 | | Eutrophication, terrestrial | 2.47e+04 | 2.478e+04 | 0.997 | | Human toxicity, cancer_inorganics | 2.928e-04 | 2.911e-04 | 1.006 | | Human toxicity, cancer_organics | 2.133e-04 | 2.132e-04 | 1.000 | | Human toxicity, cancer | 5.060e-04 | 5.043e-04 | 1.003 | | Human toxicity, non-cancer_inorganics | 0.01964 | 0.01957 | 1.003 | | Human toxicity, non-cancer_organics | 7.542e-04 | 7.541e-04 | 1.000 | | Human toxicity, non-cancer | 0.02039 | 0.02033 | 1.003 | | Ionising radiation, human health | 1.365e+05 | 1.365e+05 | 1.000 | | Land use | 2.484e+06 | 2.076e+06 | 1.196 | | Ozone depletion | 0.01292 | 0.01292 | 1.000 | | Photochemical ozone formation - human health | 1493 | 1492 | 1.000 | | Resource use, fossils | 5.891e+06 | 5.893e+06 | 1.000 | | Resource use, minerals and metals | 11.47 | 11.29 | 1.016 | | Water use | 6.119e+04 | 6.647e+04 | 0.921 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 4.922e+05 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 1.193e+09 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Ventilation unit 13000 m3/h, w. circuit connected heat exchanger, at plant [CH] | 4.635 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -2.9 / +3.6 | 10.3 (Human toxicity, non-cancer_organics) | | Ventilation duct, steel, zinc coated, s= 0.75mm, at plant [CH] | 2870 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -2.8 / +3.4 | 5.5 (Eutrophication, terrestrial) | | Ventilation duct, steel, zinc coated, s= 0.62mm, at plant [CH] | 2832 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -2.2 / +2.7 | 5.3 (Eutrophication, terrestrial) | | Ventilation duct, steel, zinc coated, s= 0.87mm, at plant [CH] | 1446 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -1.6 / +2.0 | 2.8 (Eutrophication, terrestrial) | | EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil, at plant [CH] | 2735 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -1.0 / +1.3 | 4.6 (Ecotoxicity, freshwater_organics) | | Ventilation system, Pflegezentrum Witikon, various components [CH] | 1 p | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.9 / +1.1 | 1.2 (Ionising radiation, human health) | | Ventilation duct, steel, zinc coated, s= 1.0mm, at plant [CH] | 667.2 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.8 / +1.0 | 1.3 (Eutrophication, terrestrial) | | Thermal insulation, 30mm, 40kg/m3, reinforced alumium foil, at plant [CH] | 4730 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.7 / +0.9 | 2.1 (Ecotoxicity, freshwater_organics) | | Ventilation system, Pflegezentrum Witikon, special components [CH] | 1 p | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.7 / +0.8 | 1.6 (Climate change-Land use and land use change) | | Ventilation duct, steel, zinc coated, s= 1.5mm, at plant [CH] | 379.1 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.7 / +0.8 | 1.0 (Water use) | | Silencer for ventilator unit 13000 m3/h, modular, at plant [CH] | 20.54 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.6 / +0.8 | 1.0 (Ecotoxicity, freshwater_inorganics) | | Spiral-seam duct, steel, zinc coated, s= 0.5mm, at plant [CH] | 868.6 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.5 / +0.6 | 1.4 (Eutrophication, terrestrial) | | Ventilation duct, steel, zinc coated, s= 1.25mm, at plant [CH] | 331.1 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.5 / +0.6 | 0.7 (Water use) | | Thermal insulation, 100mm, 40kg/m3, alumium cladding, at plant [CH] | 735 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.5 / +0.6 | 1.3 (Ecotoxicity, freshwater_organics) | | Ventilation duct, stainless steel, s= 1.25mm, at plant [CH] | 155.1 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.4 / +0.5 | 0.9 (Human toxicity, cancer_inorganics) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 4.923e+05 kg CO2 eq per p (95 % interval 4.787e+05–5.850e+05). Dominant contributors: Ventilation duct, steel, zinc coated, s= 0.75mm, at plant 15 %; Ventilation unit 13000 m3/h, w. circuit connected heat excha… 14 %; Ventilation duct, steel, zinc coated, s= 0.62mm, at plant 12 %; Ventilation duct, steel, zinc coated, s= 0.87mm, at plant 8 %; EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium fo… 5 %; Ventilation system, Pflegezentrum Witikon, various component… 5 %. Most sensitive: Ventilation unit 13000 m3/h, w. circuit connected heat exchanger, at plant [CH] (-2.9 / +3.6 %); Ventilation duct, steel, zinc coated, s= 0.75mm, at plant [CH] (-2.8 / +3.4 %); Ventilation duct, steel, zinc coated, s= 0.62mm, at plant [CH] (-2.2 / +2.7 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 4.4e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 22/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 32/32 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 4.923e+05 in [4.787e+05, 5.850e+05] | | time period declared | **PASS** | 2014-01/2014-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].