====== Production of heat distribution system, office building Fribourg — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:production_of_heat_distribution_system_office_building_fribourg__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Production of heat distribution system, office building Fribourg [CH], per 1 m2. EF v3.1 climate change 9.358 kg CO2 eq (Monte Carlo 95 % interval 8.72–11.23). Main contributors: Steel pipe, black, primed 70 %; Various components for heating system 15 %; PIR insulation with PVC cladding, insulation thickness 40mm 5 %; PIR insulation with PVC cladding, insulation thickness 50mm 2 %; PIR insulation with PVC cladding, insulation thickness 60mm 2 %; PIR insulation with PVC cladding, insulation thickness 80mm 2 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Production of heat distribution system, office building Fribourg | | Dataset UUID / graph id | ''%%26fb4a2c-acc0-3943-a64e-885019337652%%'' / ''%%activity:production_of_heat_distribution_system_office_building_fribourg__ch%%'' | | Reference product, unit | Production of heat distribution system, office building Fribourg, 1 m2 | | Location | CH | | Time period | 1994-01/2008-12 | | Category | heating / heating systems | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Production of components for the heat distribution system; UUID: 26fb4a2c-acc0-3943-a64e-885019337652 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 m2** of Production of heat distribution system, office building Fribourg (CH). All results are given per unit of the reference flow. ==== System boundary ==== Materials used for the production. Energy use for the different production steps. Transport of raw materials to the plant. ==== Technology ==== Technology, materials and components used for heating systems in office buildings ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Steel pipe, black, primed | technosphere | CH | 2.481 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,1) | 70.3 | ██████████████ | | | Various components for heating system | technosphere | CH | 0.3208 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,1) | 15.5 | ███ | | | PIR insulation with PVC cladding, insulation thickness 40mm | technosphere | CH | 0.07027 | m2 | lognormal, GSD² 1.07 | (1,1,1,1,1,1) | 4.8 | █ | | | PIR insulation with PVC cladding, insulation thickness 50mm | technosphere | CH | 0.02932 | m2 | lognormal, GSD² 1.07 | (1,1,1,1,1,1) | 2.4 | · | | | PIR insulation with PVC cladding, insulation thickness 60mm | technosphere | CH | 0.02421 | m2 | lognormal, GSD² 1.07 | (1,1,1,1,1,1) | 2.3 | · | | | PIR insulation with PVC cladding, insulation thickness 80mm | technosphere | CH | 0.01582 | m2 | lognormal, GSD² 1.07 | (1,1,1,1,1,1) | 2.0 | · | | | Pipe, stainless steel | technosphere | CH | 0.02607 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,1) | 1.4 | · | | | PIR insulation with PVC cladding, insulation thickness 30mm | technosphere | CH | 0.02469 | m2 | lognormal, GSD² 1.07 | (1,1,1,1,1,1) | 1.3 | · | | ==== Data quality ==== 8 of 8 direct exchanges carry a declared pedigree, 8 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 1.0 · completeness 1.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 1.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Matthias Klingler; data entry: Matthias Klingler; validation (proof reading): Matthias Klingler | | extrapolations | none | | sampling procedure | Data from call of bids for a heating system of a specific building used. Data completed with information from literature and from manufacturers | | production volume | na | | uncertainty adjustments | none | | time period comment | Amount of material investigated in 2013. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 m2. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **0.03155** | 0.02965 | 0.04152 | 1.19 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.02622** | 0.01819 | 0.05731 | 1.82 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **9.33** | 8.696 | 11.17 | 1.14 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.002364** | 0.002057 | 0.004208 | 1.47 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **9.358** | 8.72 | 11.23 | 1.14 | | EF-particulate Matter | Impact on human health | disease incidence | **6.800e-07** | 5.895e-07 | 1.076e-06 | 1.38 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **59.18** | 53.69 | 84.32 | 1.26 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1** | 0.914 | 2.762 | 1.99 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **60.18** | 54.87 | 86.39 | 1.27 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **0.006996** | 0.006519 | 0.009486 | 1.21 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **0.004307** | 0.003232 | 0.01534 | 2.26 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **0.07243** | 0.06623 | 0.1106 | 1.29 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **6.037e-09** | 5.694e-09 | 1.264e-08 | 1.53 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.394e-09** | 2.680e-09 | 5.870e-09 | 1.47 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **9.431e-09** | 9.115e-09 | 1.706e-08 | 1.39 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.632e-07** | 2.501e-07 | 6.095e-07 | 1.58 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **8.331e-09** | 7.156e-09 | 1.332e-08 | 1.38 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.715e-07** | 2.595e-07 | 6.212e-07 | 1.56 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **1.809** | 0.6598 | 10.9 | 4.26 | | Land use | Soil quality index | pt (soil quality index) | **45.11** | 39.01 | 88.37 | 1.54 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **2.079e-07** | 1.778e-07 | 3.382e-07 | 1.36 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **0.02999** | 0.02763 | 0.04779 | 1.32 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **109.6** | 103.2 | 144.2 | 1.18 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **1.165e-04** | 4.752e-05 | 2.458e-04 | — | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.858** | -3720 | 1881 | — | Climate change 9.358 kg CO2 eq per m2. Main contributors: Steel pipe, black, primed 70 %; Various components for heating system 15 %; PIR insulation with PVC cladding, insulation thickness 40mm 5 %; PIR insulation with PVC cladding, insulation thickness 50mm 2 %; PIR insulation with PVC cladding, insulation thickness 60mm 2 %; PIR insulation with PVC cladding, insulation thickness 80mm 2 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Steel pipe, black, primed 70 %; Various components for heating system 15 %; PIR insulation with PVC cladding, insulation thickness 40mm 5 %; PIR insulation with PVC cladding, insulation thickness 50mm 2 %; PIR insulation with PVC cladding, insulation thickness 60mm 2 %; PIR insulation with PVC cladding, insulation thickness 80mm 2 %. Most sensitive exchanges (Section 6.3): Steel pipe, black, primed [CH] (-4.6 / +4.9 %); Various components for heating system [CH] (-1.0 / +1.1 %); PIR insulation with PVC cladding, insulation thickness 40mm [CH] (-0.3 / +0.3 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 0.03155 | 0.03446 | 0.916 | | Climate change-Biogenic | 0.02622 | 0.02622 | 1.000 | | Climate change-Fossil | 9.33 | 9.33 | 1.000 | | Climate change-Land use and land use change | 0.002364 | 0.002364 | 1.000 | | Climate change | 9.358 | 9.358 | 1.000 | | EF-particulate Matter | 6.800e-07 | 6.800e-07 | 1.000 | | Ecotoxicity, freshwater_inorganics | 59.18 | 60.57 | 0.977 | | Ecotoxicity, freshwater_organics | 1 | 0.8938 | 1.119 | | Ecotoxicity, freshwater | 60.18 | 61.42 | 0.980 | | Eutrophication marine | 0.006996 | 0.006996 | 1.000 | | Eutrophication, freshwater | 0.004307 | 0.004307 | 1.000 | | Eutrophication, terrestrial | 0.07243 | 0.0754 | 0.961 | | Human toxicity, cancer_inorganics | 6.037e-09 | 6.006e-09 | 1.005 | | Human toxicity, cancer_organics | 3.394e-09 | 3.394e-09 | 1.000 | | Human toxicity, cancer | 9.431e-09 | 9.401e-09 | 1.003 | | Human toxicity, non-cancer_inorganics | 2.632e-07 | 2.621e-07 | 1.004 | | Human toxicity, non-cancer_organics | 8.331e-09 | 8.326e-09 | 1.001 | | Human toxicity, non-cancer | 2.715e-07 | 2.704e-07 | 1.004 | | Ionising radiation, human health | 1.809 | 1.809 | 1.000 | | Land use | 45.11 | 38.01 | 1.187 | | Ozone depletion | 2.079e-07 | 2.079e-07 | 1.000 | | Photochemical ozone formation - human health | 0.02999 | 0.02999 | 1.000 | | Resource use, fossils | 109.6 | 109.6 | 1.000 | | Resource use, minerals and metals | 1.165e-04 | 1.110e-04 | 1.050 | | Water use | 0.858 | 0.912 | 0.941 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 9.358 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 1.928e+04 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Steel pipe, black, primed [CH] | 2.481 kg | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -4.6 / +4.9 | 5.8 (Human toxicity, cancer_organics) | | Various components for heating system [CH] | 0.3208 kg | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -1.0 / +1.1 | 3.4 (Human toxicity, non-cancer_organics) | | PIR insulation with PVC cladding, insulation thickness 40mm [CH] | 0.07027 m2 | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.3 / +0.3 | 1.7 (Ecotoxicity, freshwater_inorganics) | | PIR insulation with PVC cladding, insulation thickness 50mm [CH] | 0.02932 m2 | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.2 / +0.2 | 0.9 (Ecotoxicity, freshwater_inorganics) | | PIR insulation with PVC cladding, insulation thickness 60mm [CH] | 0.02421 m2 | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.2 / +0.2 | 0.9 (Ecotoxicity, freshwater_inorganics) | | PIR insulation with PVC cladding, insulation thickness 80mm [CH] | 0.01582 m2 | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.1 / +0.1 | 0.7 (Ecotoxicity, freshwater_inorganics) | | Pipe, stainless steel [CH] | 0.02607 kg | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.1 / +0.1 | 0.2 (Climate change-Land use and land use change) | | PIR insulation with PVC cladding, insulation thickness 30mm [CH] | 0.02469 m2 | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.1 / +0.1 | 0.5 (Ecotoxicity, freshwater_inorganics) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 9.358 kg CO2 eq per m2 (95 % interval 8.72–11.23). Dominant contributors: Steel pipe, black, primed 70 %; Various components for heating system 15 %; PIR insulation with PVC cladding, insulation thickness 40mm 5 %; PIR insulation with PVC cladding, insulation thickness 50mm 2 %; PIR insulation with PVC cladding, insulation thickness 60mm 2 %; PIR insulation with PVC cladding, insulation thickness 80mm 2 %. Most sensitive: Steel pipe, black, primed [CH] (-4.6 / +4.9 %); Various components for heating system [CH] (-1.0 / +1.1 %); PIR insulation with PVC cladding, insulation thickness 40mm [CH] (-0.3 / +0.3 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 m2 | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 4.7e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 20/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 8/8 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 9.358 in [8.72, 11.23] | | time period declared | **PASS** | 1994-01/2008-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].