====== Printed wiring board, power supply unit desktop PC, solder mix, at plant — GLO ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:printed_wiring_board_power_supply_unit_desktop_pc_solder_mix_at_plant__glo|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Printed wiring board, power supply unit desktop PC, solder mix, at plant [GLO], per 1 kg. EF v3.1 climate change 31.42 kg CO2 eq (Monte Carlo 95 % interval 24.17–51.76). Main contributors: Printed wiring board, power supply unit desktop PC, Pb free,… 100 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Printed wiring board, power supply unit desktop PC, solder mix, at plant | | Dataset UUID / graph id | ''%%2ab60468-7f67-3080-957a-13628226eb33%%'' / ''%%activity:printed_wiring_board_power_supply_unit_desktop_pc_solder_mix_at_plant__glo%%'' | | Reference product, unit | Printed wiring board, power supply unit desktop PC, solder mix, at plant, 1 kg | | Location | GLO — Own estimation - used for the global average | | Time period | 2023-01/2029-12 | | Category | electronics / component | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== After 2023, only Pb-free solder technologies are assumed here.; UUID: 2ab60468-7f67-3080-957a-13628226eb33 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kg** of Printed wiring board, power supply unit desktop PC, solder mix, at plant (GLO). All results are given per unit of the reference flow. ==== System boundary ==== This dataset represents a mix of Pb-containing and Pb-free soldered PWBs used in the power supply unit (PSU) of a Desktop PC. In includes only these two distinguished soldering processes as input. ==== Technology ==== average PWB mounting technology (wave soldering) ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Printed wiring board, power supply unit desktop PC, Pb free, at plant | technosphere | GLO | 1 | kg | lognormal, GSD² 1.33 | — | 100.0 | ████████████████████ | | ==== Data quality ==== 0 of 1 direct exchanges carry a declared pedigree, 1 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Lugas Raka Adrianto, Maulana Permana Ajie, Didier Beloin-Saint-Pierre (EMPA); data entry: Lugas Raka Adrianto, Maulana Permana Ajie, Didier Beloin-Saint-Pierre (EMPA); validation (proof reading): Mischa Zschokke (CARBOTECH) | | extrapolations | see Geography & Technology | | sampling procedure | own estimation | | uncertainty adjustments | | | validation details | Proof reading validation: Passed, Other validation: none, Validator: Mischa Zschokke, Company: Carbotech, Country: CH | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kg. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **0.1793** | 0.137 | 0.2962 | 1.48 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.1273** | 0.06994 | 0.3443 | 2.27 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **31.27** | 24.09 | 51.49 | 1.48 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.02152** | 0.01413 | 0.04406 | 1.78 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **31.42** | 24.17 | 51.76 | 1.48 | | EF-particulate Matter | Impact on human health | disease incidence | **1.368e-06** | 1.122e-06 | 2.421e-06 | 1.48 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **240.7** | 204.1 | 458.9 | 1.54 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **8.577** | 6.647 | 15.7 | 1.55 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **249.3** | 212.7 | 470.3 | 1.53 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **0.02799** | 0.02255 | 0.05027 | 1.52 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **0.04637** | 0.02821 | 0.286 | 3.14 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **0.2655** | 0.2111 | 0.4947 | 1.54 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.140e-08** | 1.883e-08 | 6.463e-08 | 1.89 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **9.883e-09** | 7.639e-09 | 1.930e-08 | 1.62 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **3.128e-08** | 2.768e-08 | 8.042e-08 | 1.72 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.689e-06** | 1.295e-06 | 5.114e-06 | 2.07 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **8.429e-08** | 5.570e-08 | 1.738e-07 | 1.8 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.773e-06** | 1.375e-06 | 5.224e-06 | 2.03 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **8.538** | 2.562 | 62.99 | 4.92 | | Land use | Soil quality index | pt (soil quality index) | **238.3** | 180.1 | 530.2 | 1.73 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **7.955e-07** | 6.474e-07 | 1.445e-06 | 1.51 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **0.1845** | 0.1424 | 0.3245 | 1.51 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **444.1** | 354.9 | 802.2 | 1.51 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.007639** | 0.005695 | 0.01111 | 1.41 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **4.285** | -1.113e+04 | 5502 | — | Climate change 31.42 kg CO2 eq per kg. Main contributors: Printed wiring board, power supply unit desktop PC, Pb free,… 100 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Printed wiring board, power supply unit desktop PC, Pb free,… 100 %. Most sensitive exchanges (Section 6.3): Printed wiring board, power supply unit desktop PC, Pb free, at plant [GLO] (-24.4 / +32.2 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 0.1793 | 0.2711 | 0.661 | | Climate change-Biogenic | 0.1273 | 0.1273 | 1.000 | | Climate change-Fossil | 31.27 | 31.27 | 1.000 | | Climate change-Land use and land use change | 0.02152 | 0.02152 | 1.000 | | Climate change | 31.42 | 31.42 | 1.000 | | EF-particulate Matter | 1.368e-06 | 1.368e-06 | 1.000 | | Ecotoxicity, freshwater_inorganics | 240.7 | 243.7 | 0.988 | | Ecotoxicity, freshwater_organics | 8.577 | 7.826 | 1.096 | | Ecotoxicity, freshwater | 249.3 | 250.4 | 0.996 | | Eutrophication marine | 0.02799 | 0.02798 | 1.000 | | Eutrophication, freshwater | 0.04637 | 0.04637 | 1.000 | | Eutrophication, terrestrial | 0.2655 | 0.2808 | 0.945 | | Human toxicity, cancer_inorganics | 2.140e-08 | 2.125e-08 | 1.007 | | Human toxicity, cancer_organics | 9.883e-09 | 9.883e-09 | 1.000 | | Human toxicity, cancer | 3.128e-08 | 3.113e-08 | 1.005 | | Human toxicity, non-cancer_inorganics | 1.689e-06 | 1.681e-06 | 1.005 | | Human toxicity, non-cancer_organics | 8.429e-08 | 8.425e-08 | 1.001 | | Human toxicity, non-cancer | 1.773e-06 | 1.765e-06 | 1.004 | | Ionising radiation, human health | 8.538 | 8.538 | 1.000 | | Land use | 238.3 | 190.1 | 1.254 | | Ozone depletion | 7.955e-07 | 7.955e-07 | 1.000 | | Photochemical ozone formation - human health | 0.1845 | 0.1845 | 1.000 | | Resource use, fossils | 444.1 | 444.3 | 1.000 | | Resource use, minerals and metals | 0.007639 | 0.007594 | 1.006 | | Water use | 4.285 | 4.612 | 0.929 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 31.41 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 8.08e+04 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Printed wiring board, power supply unit desktop PC, Pb free, at plant [GLO] | 1 kg | ×0.756 / ×1.32 | lognormal, GSD² 1.33 | -24.4 / +32.2 | 32.2 (Acidification) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 31.42 kg CO2 eq per kg (95 % interval 24.17–51.76). Dominant contributors: Printed wiring board, power supply unit desktop PC, Pb free,… 100 %. Most sensitive: Printed wiring board, power supply unit desktop PC, Pb free, at plant [GLO] (-24.4 / +32.2 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kg | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 0.0e+00 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 20/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 1/1 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 31.42 in [24.17, 51.76] | | time period declared | **PASS** | 2023-01/2029-12 | | geography is a known location code | **PASS** | GLO | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Raka Adrianto L. (2024) 2024 - LCI ICT sector - Raka Adrianto. Empa — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].