====== xxx Electricity mix, GO cancellations — SI ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:xxx_electricity_mix_go_cancellations__si|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset xxx Electricity mix, GO cancellations [SI], per 1 kWh. EF v3.1 climate change 0.01679 kg CO2 eq (Monte Carlo 95 % interval 0.01462–0.0296). Main contributors: Electricity, at cogen 1MWth, wood chips, allocation exergy 54 %; Electricity, hydropower, at reservoir power plant, non alpin… 19 %; Electricity, production mix photovoltaic, at plant 11 %; Electricity, hydropower, at run-of-river power plant 9 %; Electricity, hydropower, at reservoir power plant, alpine re… 6 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | xxx Electricity mix, GO cancellations | | Dataset UUID / graph id | ''%%2bc5ca65-ac54-32ed-b6fb-d2eb7854763d%%'' / ''%%activity:xxx_electricity_mix_go_cancellations__si%%'' | | Reference product, unit | xxx Electricity mix, GO cancellations, 1 kWh | | Location | SI — undefined | | Time period | 2018-01/2018-12 | | Category | electricity / notMaintained | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== The location and technology of the production of the residual attributes have been for some technologies (biomass, solar, hydropower) adapted by the ENTSO-mix based on technologies, which is a rough estimation. Time period: Time of publications. Version: 1 Energy values: Undefined Local category: Elektrizität Local subcategory: Erzeugungsmix UVEK 2022 source file:726-Strommixe-EU_v0.8._X-GO cancellations 2018.xml UUID: 2bc5ca65-ac54-32ed-b6fb-d2eb7854763d This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kWh** of xxx Electricity mix, GO cancellations (SI). All results are given per unit of the reference flow. ==== System boundary ==== Included are the shares of cancelled GOs by technology in 2018. Not included are transformation, transport or distribution losses. ==== Technology ==== undefined ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electricity, at cogen 1MWth, wood chips, allocation exergy | technosphere | CH | 0.14584 | kWh | lognormal, GSD² 1.05 | — | 54.3 | ███████████ | | | Electricity, hydropower, at reservoir power plant, non alpine regions | technosphere | RER | 0.20134 | kWh | lognormal, GSD² 1.05 | — | 19.4 | ████ | | | Electricity, production mix photovoltaic, at plant | technosphere | DE | 0.06065 | kWh | lognormal, GSD² 1.05 | — | 11.3 | ██ | | | Electricity, hydropower, at run-of-river power plant | technosphere | RER | 0.39083 | kWh | lognormal, GSD² 1.05 | — | 8.7 | ██ | | | Electricity, hydropower, at reservoir power plant, alpine region | technosphere | RER | 0.20134 | kWh | lognormal, GSD² 1.05 | — | 6.2 | █ | | | Electricity, at wind farm | technosphere | RER | 1.4575e-07 | kWh | lognormal, GSD² 1.05 | — | 0.0 | · | | ==== Data quality ==== 0 of 6 direct exchanges carry a declared pedigree, 6 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Luana Krebs (TREEZE); data entry: Luana Krebs (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | | | sampling procedure | | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: 10.02.2021; Other validation: G:\Projekte laufend\726 Umweltbilanz Strommix Schweiz 2018\EcoSpold[726-Strommixe-EU_v0.8.xlsx]X-Process; | | time period comment | Time of publications. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **8.131e-05** | 6.860e-05 | 1.233e-04 | 1.35 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **5.630e-04** | 3.842e-04 | 9.531e-04 | 1.57 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.01376** | 0.0119 | 0.02606 | 1.53 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.002459** | 0.001261 | 0.00519 | 2.03 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.01679** | 0.01462 | 0.0296 | 1.45 | | EF-particulate Matter | Impact on human health | disease incidence | **3.804e-09** | 2.011e-09 | 9.776e-09 | 2.29 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.04127** | 0.03804 | 0.121 | 1.8 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.003846** | 0.003148 | 0.006781 | 1.49 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.04512** | 0.04217 | 0.1261 | 1.75 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **6.961e-05** | 5.095e-05 | 1.057e-04 | 1.46 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **4.684e-06** | 3.550e-06 | 4.913e-05 | 3.55 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **7.164e-04** | 5.427e-04 | 0.001037 | 1.39 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **4.473e-12** | 4.687e-12 | 1.309e-11 | 1.69 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.110e-10** | 1.159e-10 | 3.906e-10 | 1.83 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.154e-10** | 1.233e-10 | 4.003e-10 | 1.8 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **4.616e-10** | 3.985e-10 | 1.380e-09 | 1.91 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.720e-11** | 1.428e-11 | 3.675e-11 | 1.62 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **4.788e-10** | 4.163e-10 | 1.405e-09 | 1.89 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.001964** | 8.586e-04 | 0.01454 | 4.59 | | Land use | Soil quality index | pt (soil quality index) | **11.57** | 6.956 | 19.77 | 1.71 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **3.215e-10** | 2.731e-10 | 7.089e-10 | 1.62 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **2.246e-04** | 1.720e-04 | 3.344e-04 | 1.4 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.1628** | 0.1382 | 0.3407 | 1.6 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **1.959e-07** | 1.774e-07 | 3.923e-07 | 1.52 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.001407** | -1139 | 563.2 | — | Climate change 0.01679 kg CO2 eq per kWh. Main contributors: Electricity, at cogen 1MWth, wood chips, allocation exergy 54 %; Electricity, hydropower, at reservoir power plant, non alpin… 19 %; Electricity, production mix photovoltaic, at plant 11 %; Electricity, hydropower, at run-of-river power plant 9 %; Electricity, hydropower, at reservoir power plant, alpine re… 6 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electricity, at cogen 1MWth, wood chips, allocation exergy 54 %; Electricity, hydropower, at reservoir power plant, non alpin… 19 %; Electricity, production mix photovoltaic, at plant 11 %; Electricity, hydropower, at run-of-river power plant 9 %; Electricity, hydropower, at reservoir power plant, alpine re… 6 %. Most sensitive exchanges (Section 6.3): Electricity, at cogen 1MWth, wood chips, allocation exergy [CH] (-2.5 / +2.7 %); Electricity, hydropower, at reservoir power plant, non alpine regions [RER] (-0.9 / +1.0 %); Electricity, production mix photovoltaic, at plant [DE] (-0.5 / +0.6 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh: ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 8.131e-05 | 1.834e-04 | 0.443 | | Climate change-Biogenic | 5.630e-04 | 5.630e-04 | 1.000 | | Climate change-Fossil | 0.01376 | 0.01376 | 1.000 | | Climate change-Land use and land use change | 0.002459 | 0.002459 | 1.000 | | Climate change | 0.01679 | 0.01679 | 1.000 | | EF-particulate Matter | 3.804e-09 | 3.804e-09 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.04127 | 0.04187 | 0.986 | | Ecotoxicity, freshwater_organics | 0.003846 | 0.003808 | 1.010 | | Ecotoxicity, freshwater | 0.04512 | 0.04562 | 0.989 | | Eutrophication marine | 6.961e-05 | 6.961e-05 | 1.000 | | Eutrophication, freshwater | 4.684e-06 | 4.684e-06 | 1.000 | | Eutrophication, terrestrial | 7.164e-04 | 8.262e-04 | 0.867 | | Human toxicity, cancer_inorganics | 4.473e-12 | 4.447e-12 | 1.006 | | Human toxicity, cancer_organics | 2.110e-10 | 2.110e-10 | 1.000 | | Human toxicity, cancer | 2.154e-10 | 2.154e-10 | 1.000 | | Human toxicity, non-cancer_inorganics | 4.616e-10 | 4.606e-10 | 1.002 | | Human toxicity, non-cancer_organics | 1.720e-11 | 1.720e-11 | 1.000 | | Human toxicity, non-cancer | 4.788e-10 | 4.778e-10 | 1.002 | | Ionising radiation, human health | 0.001964 | 0.001964 | 1.000 | | Land use | 11.57 | 9.251 | 1.251 | | Ozone depletion | 3.215e-10 | 3.215e-10 | 1.000 | | Photochemical ozone formation - human health | 2.246e-04 | 2.246e-04 | 1.000 | | Resource use, fossils | 0.1628 | 0.1628 | 1.000 | | Resource use, minerals and metals | 1.959e-07 | 1.943e-07 | 1.009 | | Water use | 0.001407 | 0.001528 | 0.921 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.01678 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 62.9 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Electricity, at cogen 1MWth, wood chips, allocation exergy [CH] | 0.1458 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -2.5 / +2.7 | 4.9 (Land use) | | Electricity, hydropower, at reservoir power plant, non alpine regions [RER] | 0.2013 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.9 / +1.0 | 4.3 (Climate change-Land use and land use change) | | Electricity, production mix photovoltaic, at plant [DE] | 0.06065 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.5 / +0.6 | 3.5 (Resource use, minerals and metals) | | Electricity, hydropower, at run-of-river power plant [RER] | 0.3908 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.4 / +0.4 | 1.2 (Climate change-Biogenic) | | Electricity, hydropower, at reservoir power plant, alpine region [RER] | 0.2013 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.3 / +0.3 | 0.5 (Climate change-Land use and land use change) | | Electricity, at wind farm [RER] | 1.457e-07 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.0 / +0.0 | 0.0 (Eutrophication, freshwater) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== ^ Source ^ Scope ^ Value ^ This dataset ^ Ratio ^ Note ^ | bafu | xxx Electricity mix, GO cancellations [CY] | 0.007271 kg CO2 eq | 0.01679 | 2.31 | same dataset name, other location | | bafu | xxx Electricity mix, GO cancellations [MT] | 0.007271 kg CO2 eq | 0.01679 | 2.31 | same dataset name, other location | | bafu | xxx Electricity mix, GO cancellations [PT] | 0.007289 kg CO2 eq | 0.01679 | 2.30 | same dataset name, other location | | bafu | xxx Electricity mix, GO cancellations [GR] | 0.008748 kg CO2 eq | 0.01679 | 1.92 | same dataset name, other location | | bafu | xxx Electricity mix, GO cancellations [NO] | 0.008867 kg CO2 eq | 0.01679 | 1.89 | same dataset name, other location | | bafu | xxx Electricity mix, GO cancellations [BE] | 0.08314 kg CO2 eq | 0.01679 | 0.20 | same dataset name, other location | | bafu | xxx Electricity mix, GO cancellations [ES] | 0.08837 kg CO2 eq | 0.01679 | 0.19 | same dataset name, other location | | bafu | xxx Electricity mix, GO cancellations [AT] | 0.14 kg CO2 eq | 0.01679 | 0.12 | same dataset name, other location | | bafu | xxx Electricity mix, GO cancellations [LU] | 0.1593 kg CO2 eq | 0.01679 | 0.11 | same dataset name, other location | | bafu | xxx Electricity mix, GO cancellations [IE] | 0.2115 kg CO2 eq | 0.01679 | 0.08 | same dataset name, other location | ==== Conclusions and limitations ==== GWP100 0.01679 kg CO2 eq per kWh (95 % interval 0.01462–0.0296). Dominant contributors: Electricity, at cogen 1MWth, wood chips, allocation exergy 54 %; Electricity, hydropower, at reservoir power plant, non alpin… 19 %; Electricity, production mix photovoltaic, at plant 11 %; Electricity, hydropower, at run-of-river power plant 9 %; Electricity, hydropower, at reservoir power plant, alpine re… 6 %. Most sensitive: Electricity, at cogen 1MWth, wood chips, allocation exergy [CH] (-2.5 / +2.7 %); Electricity, hydropower, at reservoir power plant, non alpine regions [RER] (-0.9 / +1.0 %); Electricity, production mix photovoltaic, at plant [DE] (-0.5 / +0.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kWh | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.5e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 6/6 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.01679 in [0.01462, 0.0296] | | time period declared | **PASS** | 2018-01/2018-12 | | geography is a known location code | **PASS** | SI | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Krebs L., Stolz P., Frischknecht R. (2020) Umweltbilanz Strommix Schweiz 2018. Project reports. Volume: 723. treeze Ltd.. Uster, CH. Type: Separate publication First author: Krebs L. Other authors: Stolz P., Frischknecht R. Year: 2020 Title of anthology: Project reports Place of publication: Uster, CH Publisher: treeze Ltd. Volume No: 723 — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].