====== xxx Heat, at flat plate collector, multiple dwelling, for hot water — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:xxx_heat_at_flat_plate_collector_multiple_dwelling_for_hot_water__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset xxx Heat, at flat plate collector, multiple dwelling, for hot water [CH], per 1 MJ. EF v3.1 climate change 0.002223 kg CO2 eq (Monte Carlo 95 % interval 0.001033–0.006553). Main contributors: xxx Solar system, flat plate collector, multiple dwelling, h… 92 %; Electricity, low voltage, at grid 7 %; Transport, freight, lorry, 3.5t gross weight, fleet average 1 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | xxx Heat, at flat plate collector, multiple dwelling, for hot water | | Dataset UUID / graph id | ''%%3100dcab-dc76-36b3-b870-b6bba1171a66%%'' / ''%%activity:xxx_heat_at_flat_plate_collector_multiple_dwelling_for_hot_water__ch%%'' | | Reference product, unit | xxx Heat, at flat plate collector, multiple dwelling, for hot water, 1 MJ | | Location | CH | | Time period | 9999-01/9999-12 | | Category | energy, obsolete / others, obsolete | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Use of a solar system excluding the necessary auxiliary heating.; UUID: 3100dcab-dc76-36b3-b870-b6bba1171a66 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 MJ** of xxx Heat, at flat plate collector, multiple dwelling, for hot water (CH). All results are given per unit of the reference flow. ==== System boundary ==== Delivery of heat with a solar system including maintenance and electricity use for operation. Excluding the necessary auxiliary heating. ==== Technology ==== Operation of a solar system, not including the necessary additional heating. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | xxx Solar system, flat plate collector, multiple dwelling, hot water | technosphere | CH | 2.5707e-07 | p | lognormal, GSD² 3 | — | 91.8 | ██████████████████ | | | Electricity, low voltage, at grid | technosphere | CH | 0.0015579 | kWh | lognormal, GSD² 1.07 | — | 6.8 | █ | | | Transport, freight, lorry, 3.5t gross weight, fleet average | technosphere | CH | 2.8278e-05 | tkm | lognormal, GSD² 3 | — | 1.4 | · | | | Energy, Solar, Converted | elementary | natural resource | 1.1315 | MJ | lognormal, GSD² 1.07 | — | 0.0 | · | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 1.1372 | MJ | lognormal, GSD² 1.07 | — | 0.0 | · | | ==== Data quality ==== 0 of 5 direct exchanges carry a declared pedigree, 5 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Niels Jungbluth (ESU); data entry: Niels Jungbluth (ESU); validation (proof reading): Sebastiano Meier | | extrapolations | none | | sampling procedure | Simulation done by SPF Rapperswil with Polysun 3.3 computer programme. | | production volume | Total solar heat delivered by flat plate collectors in 2001 was 37TJ. | | uncertainty adjustments | none | | validation details | Proof reading validation: passed; Other validation: none; | | time period comment | Time of simulation. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 MJ. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **1.960e-05** | 7.848e-06 | 5.952e-05 | 2.84 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **9.853e-06** | 5.970e-06 | 2.809e-05 | 2.2 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.002211** | 0.001025 | 0.006523 | 2.58 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.647e-06** | 9.491e-07 | 4.308e-06 | 2.15 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.002223** | 0.001033 | 0.006553 | 2.57 | | EF-particulate Matter | Impact on human health | disease incidence | **1.281e-10** | 6.294e-11 | 6.155e-10 | 3.18 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.04827** | 0.01805 | 0.1843 | 3.21 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **3.889e-04** | 1.812e-04 | 0.001666 | 3.25 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.04866** | 0.01828 | 0.1864 | 3.2 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **2.950e-06** | 1.346e-06 | 9.309e-06 | 2.7 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **4.251e-06** | 1.672e-06 | 3.340e-05 | 4.6 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **2.958e-05** | 1.285e-05 | 9.207e-05 | 2.74 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.299e-12** | 1.113e-12 | 9.736e-12 | 3.1 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.404e-13** | 3.689e-13 | 2.507e-12 | 2.71 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **3.039e-12** | 1.552e-12 | 1.223e-11 | 2.93 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.685e-10** | 7.851e-11 | 7.590e-10 | 3.25 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.212e-11** | 4.369e-12 | 4.355e-11 | 3.31 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.806e-10** | 8.537e-11 | 8.092e-10 | 3.21 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.001731** | 6.408e-04 | 0.01068 | 4.37 | | Land use | Soil quality index | pt (soil quality index) | **0.0224** | 0.0115 | 0.06782 | 2.53 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **2.131e-10** | 9.905e-11 | 7.117e-10 | 2.7 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **1.020e-05** | 4.633e-06 | 3.303e-05 | 2.7 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.04011** | 0.02428 | 0.1045 | 2.13 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **1.114e-07** | 4.273e-08 | 3.224e-07 | 2.82 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **2.867e-04** | -1.782 | 0.8999 | — | Climate change 0.002223 kg CO2 eq per MJ. Main contributors: xxx Solar system, flat plate collector, multiple dwelling, h… 92 %; Electricity, low voltage, at grid 7 %; Transport, freight, lorry, 3.5t gross weight, fleet average 1 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: xxx Solar system, flat plate collector, multiple dwelling, h… 92 %; Electricity, low voltage, at grid 7 %; Transport, freight, lorry, 3.5t gross weight, fleet average 1 %. Most sensitive exchanges (Section 6.3): xxx Solar system, flat plate collector, multiple dwelling, hot water [CH] (-60.6 / +178.0 %); Transport, freight, lorry, 3.5t gross weight, fleet average [CH] (-0.9 / +2.7 %); Electricity, low voltage, at grid [CH] (-0.4 / +0.5 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 1.960e-05 | 2.086e-05 | 0.939 | | Climate change-Biogenic | 9.853e-06 | 9.853e-06 | 1.000 | | Climate change-Fossil | 0.002211 | 0.002211 | 1.000 | | Climate change-Land use and land use change | 1.647e-06 | 1.647e-06 | 1.000 | | Climate change | 0.002223 | 0.002223 | 1.000 | | EF-particulate Matter | 1.281e-10 | 1.281e-10 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.04827 | 0.04856 | 0.994 | | Ecotoxicity, freshwater_organics | 3.889e-04 | 3.872e-04 | 1.004 | | Ecotoxicity, freshwater | 0.04866 | 0.04894 | 0.994 | | Eutrophication marine | 2.950e-06 | 2.949e-06 | 1.000 | | Eutrophication, freshwater | 4.251e-06 | 4.251e-06 | 1.000 | | Eutrophication, terrestrial | 2.958e-05 | 3.149e-05 | 0.939 | | Human toxicity, cancer_inorganics | 2.299e-12 | 2.288e-12 | 1.005 | | Human toxicity, cancer_organics | 7.404e-13 | 7.404e-13 | 1.000 | | Human toxicity, cancer | 3.039e-12 | 3.028e-12 | 1.004 | | Human toxicity, non-cancer_inorganics | 1.685e-10 | 1.680e-10 | 1.003 | | Human toxicity, non-cancer_organics | 1.212e-11 | 1.212e-11 | 1.000 | | Human toxicity, non-cancer | 1.806e-10 | 1.801e-10 | 1.003 | | Ionising radiation, human health | 0.001731 | 0.001731 | 1.000 | | Land use | 0.0224 | 0.01658 | 1.351 | | Ozone depletion | 2.131e-10 | 2.131e-10 | 1.000 | | Photochemical ozone formation - human health | 1.020e-05 | 1.020e-05 | 1.000 | | Resource use, fossils | 0.04011 | 0.04012 | 1.000 | | Resource use, minerals and metals | 1.114e-07 | 1.087e-07 | 1.025 | | Water use | 2.867e-04 | 3.170e-04 | 0.904 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.002223 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 9.854 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | xxx Solar system, flat plate collector, multiple dwelling, hot water [CH] | 2.571e-07 p | ×0.34 / ×2.94 | lognormal, GSD² 3 | -60.6 / +178.0 | 191.6 (Ecotoxicity, freshwater_inorganics) | | Transport, freight, lorry, 3.5t gross weight, fleet average [CH] | 2.828e-05 tkm | ×0.34 / ×2.94 | lognormal, GSD² 3 | -0.9 / +2.7 | 4.7 (Ecotoxicity, freshwater_organics) | | Electricity, low voltage, at grid [CH] | 0.001558 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.4 / +0.5 | 4.5 (Ionising radiation, human health) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.002223 kg CO2 eq per MJ (95 % interval 0.001033–0.006553). Dominant contributors: xxx Solar system, flat plate collector, multiple dwelling, h… 92 %; Electricity, low voltage, at grid 7 %; Transport, freight, lorry, 3.5t gross weight, fleet average 1 %. Most sensitive: xxx Solar system, flat plate collector, multiple dwelling, hot water [CH] (-60.6 / +178.0 %); Transport, freight, lorry, 3.5t gross weight, fleet average [CH] (-0.9 / +2.7 %); Electricity, low voltage, at grid [CH] (-0.4 / +0.5 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 MJ | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.0e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 5/5 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.002223 in [0.001033, 0.006553] | | time period declared | **PASS** | 9999-01/9999-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Jungbluth, N. (2007) Sonnenkollektor-Anlagen. Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0. Editors: Dones R.. Volume: 6. Swiss Centre for LCI, PSI. Dübendorf and Villigen, CH. Type: Measurement on site Source: CD-ROM First author: Jungbluth, N. Year: 2007 Name of editors: Dones R. Title of anthology: Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].