====== Heat, at heat pump 30kW, allocation price — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:heat_at_heat_pump_30kw_allocation_price__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Heat, at heat pump 30kW, allocation price [CH], per 1 MJ. EF v3.1 climate change 0.04242 kg CO2 eq (Monte Carlo 95 % interval 0.03481–0.05536). Main contributors: Electricity, at cogen 160kWe Jakobsberg, allocation price 98 %; 1,1,1,2-Tetrafluoroethane 1 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Heat, at heat pump 30kW, allocation price | | Dataset UUID / graph id | ''%%357087ab-7e3e-3eb2-afa1-389a288bb452%%'' / ''%%activity:heat_at_heat_pump_30kw_allocation_price__ch%%'' | | Reference product, unit | Heat, at heat pump 30kW, allocation price, 1 MJ | | Location | CH — Could be used for European conditions. | | Time period | 2000-01/2000-12 | | Category | energy, obsolete / heat, obsolete\heat pumps, obsolete | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Heat from 30 kW heat pump installed at 160kW cogeneration unit.; UUID: 357087ab-7e3e-3eb2-afa1-389a288bb452 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 MJ** of Heat, at heat pump 30kW, allocation price (CH). All results are given per unit of the reference flow. ==== System boundary ==== Includes heat pump infrastructure, electricity from cogeneration unit, and refrigerant R134a emissions during operation. ==== Technology ==== none ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electricity, at cogen 160kWe Jakobsberg, allocation price | technosphere | CH | 0.0617 | kWh | lognormal, GSD² 1.2 | — | 98.2 | ████████████████████ | | | Heat pump 30kW | technosphere | RER | 3.4700e-08 | p | lognormal, GSD² 1.5 | — | 0.4 | · | | | 1,1,1,2-Tetrafluoroethane | elementary | air/Ground level / Urban (>1000 people/s… | 3.9300e-07 | kg | lognormal, GSD² 1.7 | — | 1.4 | · | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 0.222 | MJ | lognormal, GSD² 1.2 | — | 0.0 | · | | ==== Data quality ==== 0 of 4 direct exchanges carry a declared pedigree, 4 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Thomas Heck; data entry: Thomas Heck; validation (proof reading): Gerald Rebitzer | | extrapolations | none | | sampling procedure | Literature, manufacturer information | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: prepared; Other validation: none; | | time period comment | undefined | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 MJ. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **2.174e-05** | 1.459e-05 | 4.247e-05 | 1.74 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2.252e-05** | 9.850e-06 | 9.684e-05 | 3.22 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.04239** | 0.0348 | 0.05525 | 1.28 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **3.326e-06** | 2.159e-06 | 7.668e-06 | 1.89 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.04242** | 0.03481 | 0.05536 | 1.28 | | EF-particulate Matter | Impact on human health | disease incidence | **1.620e-10** | 1.222e-10 | 3.603e-10 | 1.71 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.1306** | 0.06675 | 0.3685 | 2.35 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.00307** | 0.00174 | 0.007806 | 2.17 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.1336** | 0.06855 | 0.3735 | 2.33 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **1.203e-05** | 8.216e-06 | 2.224e-05 | 1.7 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **1.476e-06** | 8.931e-07 | 8.201e-06 | 3.08 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **9.860e-05** | 6.584e-05 | 1.886e-04 | 1.71 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.023e-12** | 9.822e-13 | 3.367e-12 | 1.91 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.242e-12** | 8.349e-13 | 4.086e-12 | 2.21 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.265e-12** | 1.926e-12 | 7.020e-12 | 1.94 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.643e-11** | 6.746e-11 | 2.315e-10 | 1.93 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.082e-11** | 7.585e-12 | 1.969e-11 | 1.64 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **8.725e-11** | 7.478e-11 | 2.503e-10 | 1.88 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.001512** | 4.217e-04 | 0.01369 | 5.98 | | Land use | Soil quality index | pt (soil quality index) | **0.02712** | 0.01836 | 0.07872 | 2.08 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **3.948e-09** | 2.261e-09 | 8.145e-09 | 1.95 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **6.345e-05** | 4.032e-05 | 1.289e-04 | 1.81 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.6606** | 0.3631 | 1.241 | 1.86 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **1.733e-08** | 1.380e-08 | 3.815e-08 | 1.7 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **4.416e-04** | -1.507 | 0.7844 | — | Climate change 0.04242 kg CO2 eq per MJ. Main contributors: Electricity, at cogen 160kWe Jakobsberg, allocation price 98 %; 1,1,1,2-Tetrafluoroethane 1 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electricity, at cogen 160kWe Jakobsberg, allocation price 98 %; 1,1,1,2-Tetrafluoroethane 1 %. Most sensitive exchanges (Section 6.3): Electricity, at cogen 160kWe Jakobsberg, allocation price [CH] (-16.1 / +19.2 %); 1,1,1,2-Tetrafluoroethane [air/Ground level / Urban (>1000 people/square mile)] (-0.6 / +1.0 %); Heat pump 30kW [RER] (-0.1 / +0.2 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 2.174e-05 | 3.254e-05 | 0.668 | | Climate change-Biogenic | 2.252e-05 | 2.252e-05 | 1.000 | | Climate change-Fossil | 0.04239 | 0.04239 | 1.000 | | Climate change-Land use and land use change | 3.326e-06 | 3.326e-06 | 1.000 | | Climate change | 0.04242 | 0.04242 | 1.000 | | EF-particulate Matter | 1.620e-10 | 1.620e-10 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.1306 | 0.1307 | 0.999 | | Ecotoxicity, freshwater_organics | 0.00307 | 0.003052 | 1.006 | | Ecotoxicity, freshwater | 0.1336 | 0.1337 | 0.999 | | Eutrophication marine | 1.203e-05 | 1.203e-05 | 1.000 | | Eutrophication, freshwater | 1.476e-06 | 1.476e-06 | 1.000 | | Eutrophication, terrestrial | 9.860e-05 | 1.200e-04 | 0.822 | | Human toxicity, cancer_inorganics | 1.023e-12 | 9.980e-13 | 1.025 | | Human toxicity, cancer_organics | 1.242e-12 | 1.242e-12 | 1.000 | | Human toxicity, cancer | 2.265e-12 | 2.240e-12 | 1.011 | | Human toxicity, non-cancer_inorganics | 7.643e-11 | 7.557e-11 | 1.011 | | Human toxicity, non-cancer_organics | 1.082e-11 | 1.082e-11 | 1.000 | | Human toxicity, non-cancer | 8.725e-11 | 8.639e-11 | 1.010 | | Ionising radiation, human health | 0.001512 | 0.001512 | 1.000 | | Land use | 0.02712 | 0.03258 | 0.833 | | Ozone depletion | 3.948e-09 | 3.948e-09 | 1.000 | | Photochemical ozone formation - human health | 6.345e-05 | 6.345e-05 | 1.000 | | Resource use, fossils | 0.6606 | 0.6606 | 1.000 | | Resource use, minerals and metals | 1.733e-08 | 1.455e-08 | 1.191 | | Water use | 4.416e-04 | 4.402e-04 | 1.003 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.04241 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 52.79 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Electricity, at cogen 160kWe Jakobsberg, allocation price [CH] | 0.0617 kWh | ×0.836 / ×1.2 | lognormal, GSD² 1.2 | -16.1 / +19.2 | 19.5 (Resource use, fossils) | | 1,1,1,2-Tetrafluoroethane [air/Ground level / Urban (>1000 people/square mile)] | 3.930e-07 kg | ×0.595 / ×1.68 | lognormal, GSD² 1.7 | -0.6 / +1.0 | 1.0 (Climate change-Fossil) | | Heat pump 30kW [RER] | 3.470e-08 p | ×0.672 / ×1.49 | lognormal, GSD² 1.5 | -0.1 / +0.2 | 33.6 (Ozone depletion) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.04242 kg CO2 eq per MJ (95 % interval 0.03481–0.05536). Dominant contributors: Electricity, at cogen 160kWe Jakobsberg, allocation price 98 %; 1,1,1,2-Tetrafluoroethane 1 %. Most sensitive: Electricity, at cogen 160kWe Jakobsberg, allocation price [CH] (-16.1 / +19.2 %); 1,1,1,2-Tetrafluoroethane [air/Ground level / Urban (>1000 people/square mile)] (-0.6 / +1.0 %); Heat pump 30kW [RER] (-0.1 / +0.2 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 MJ | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.0e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 4/4 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.04242 in [0.03481, 0.05536] | | time period declared | **PASS** | 2000-01/2000-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Heck, T. (2007) Wärme-Kraft-Kopplung. Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0. Editors: Dones R.. Volume: 6. Swiss Centre for LCI, PSI. Dübendorf and Villigen, CH. Type: Measurement on site Source: CD-ROM First author: Heck, T. Year: 2007 Name of editors: Dones R. Title of anthology: Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0 Place of … — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].