====== Office, simple sanitary installation, incl. appliances and pipes, deconstruction — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:office_simple_sanitary_installation_incl_appliances_and_pipes_deconstruction__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Office, simple sanitary installation, incl. appliances and pipes, deconstruction [CH], per 1 m2. EF v3.1 climate change 1.147 kg CO2 eq (Monte Carlo 95 % interval 1.06–1.303). Main contributors: Disposal, polyethylene, 0.4% water, to municipal incineratio… 67 %; Disposal, plastics, mixture, 15.3% water, to municipal incin… 19 %; Disposal, polyurethane, 0.2% water, to municipal incineratio… 13 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Office, simple sanitary installation, incl. appliances and pipes, deconstruction | | Dataset UUID / graph id | ''%%3725d558-f901-3bba-b3a6-1a81d9dc2dd7%%'' / ''%%activity:office_simple_sanitary_installation_incl_appliances_and_pipes_deconstruction__ch%%'' | | Reference product, unit | Office, simple sanitary installation, incl. appliances and pipes, deconstruction, 1 m2 | | Location | CH — Data for Zurich, Switzerland | | Time period | 2014-01/2014-12 | | Category | construction materials / others | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Simple sanitary system for offices; UUID: 3725d558-f901-3bba-b3a6-1a81d9dc2dd7 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 m2** of Office, simple sanitary installation, incl. appliances and pipes, deconstruction (CH). All results are given per unit of the reference flow. ==== System boundary ==== This data set includes deconstruction and disposal of the sanitary system of an office building with simple sanitary installatons per energy reference area. Transport is included. ==== Technology ==== Average technology ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Disposal, polyethylene, 0.4% water, to municipal incineration | technosphere | CH | 0.25531 | kg | lognormal, GSD² 1.11 | — | 67.5 | █████████████ | | | Disposal, plastics, mixture, 15.3% water, to municipal incineration | technosphere | CH | 0.089456 | kg | lognormal, GSD² 1.11 | — | 18.6 | ████ | | | Disposal, polyurethane, 0.2% water, to municipal incineration | technosphere | CH | 0.056129 | kg | lognormal, GSD² 1.11 | — | 13.4 | ███ | | | Transport, freight, lorry, 16t-32t gross weight, fleet average | technosphere | CH | 0.029234 | tkm | lognormal, GSD² 2.01 | — | 0.4 | · | | | Diesel, burned in building machine, average | technosphere | CH | 0.0075229 | MJ | lognormal, GSD² 1.11 | — | 0.1 | · | | | Excavation, hydraulic digger, average | technosphere | CH | 5.8858e-04 | m3 | lognormal, GSD² 1.11 | — | 0.0 | · | | | Disposal, inert waste, 5% water, to construction waste landfill | technosphere | CH | 0.20074 | kg | lognormal, GSD² 1.11 | — | 0.0 | · | | | Shredding, electrical and electronic scrap | technosphere | CH | 0.021633 | kg | lognormal, GSD² 1.11 | — | 0.0 | · | | | Electricity, low voltage, consumer mix GO, at grid | technosphere | CH | 0.0036835 | kWh | lognormal, GSD² 1.11 | — | 0.0 | · | | ==== Data quality ==== 0 of 9 direct exchanges carry a declared pedigree, 9 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Franziska Wyss (TREEZE); data entry: Franziska Wyss (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | none | | sampling procedure | unknown | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: 20.02.2014; Other validation: G:\Projekte laufend\500 Aktualisierung KBOB-Liste 2014\EcoSpold[500_ecospold_Sanitärinstallationen_v0.1.xlsx]X-Process; | | time period comment | undefined | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 m2. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **1.163e-04** | 8.248e-05 | 3.355e-04 | 2.04 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **3.178e-05** | 2.384e-05 | 1.032e-04 | 2.1 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.147** | 1.06 | 1.303 | 1.11 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **6.599e-06** | 5.742e-06 | 1.279e-05 | 1.5 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.147** | 1.06 | 1.303 | 1.11 | | EF-particulate Matter | Impact on human health | disease incidence | **1.189e-09** | 1.034e-09 | 2.862e-09 | 1.68 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.9653** | 0.6895 | 1.991 | 1.69 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.002749** | 0.002246 | 0.007947 | 1.95 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.968** | 0.6937 | 1.995 | 1.68 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **1.886e-04** | 1.244e-04 | 5.122e-04 | 2.04 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **7.072e-06** | 3.340e-06 | 1.636e-04 | 6.96 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **0.001204** | 6.940e-04 | 0.003858 | 2.39 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.117e-11** | 3.816e-11 | 2.500e-10 | 2.61 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.082e-12** | 2.891e-12 | 7.278e-12 | 1.62 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **5.425e-11** | 4.235e-11 | 2.544e-10 | 2.5 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.231e-09** | 1.596e-09 | 1.217e-08 | 2.84 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.558e-11** | 1.375e-11 | 3.251e-11 | 1.53 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.246e-09** | 1.614e-09 | 1.218e-08 | 2.83 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.004698** | 0.001958 | 0.033 | 4.24 | | Land use | Soil quality index | pt (soil quality index) | **0.135** | 0.03225 | 0.3056 | — | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **9.929e-10** | 8.079e-10 | 2.636e-09 | 1.81 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **3.967e-04** | 2.417e-04 | 0.001233 | 2.28 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.3994** | 0.3022 | 1.236 | 2.01 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **4.727e-08** | 4.260e-08 | 1.214e-07 | 1.71 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.0341** | -4.295 | 2.431 | — | Climate change 1.147 kg CO2 eq per m2. Main contributors: Disposal, polyethylene, 0.4% water, to municipal incineratio… 67 %; Disposal, plastics, mixture, 15.3% water, to municipal incin… 19 %; Disposal, polyurethane, 0.2% water, to municipal incineratio… 13 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Disposal, polyethylene, 0.4% water, to municipal incineratio… 67 %; Disposal, plastics, mixture, 15.3% water, to municipal incin… 19 %; Disposal, polyurethane, 0.2% water, to municipal incineratio… 13 %. Most sensitive exchanges (Section 6.3): Disposal, polyethylene, 0.4% water, to municipal incineration [CH] (-6.8 / +7.6 %); Disposal, plastics, mixture, 15.3% water, to municipal incineration [CH] (-1.9 / +2.1 %); Disposal, polyurethane, 0.2% water, to municipal incineration [CH] (-1.4 / +1.5 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 1.163e-04 | 2.938e-04 | 0.396 | | Climate change-Biogenic | 3.178e-05 | 3.177e-05 | 1.000 | | Climate change-Fossil | 1.147 | 1.147 | 1.000 | | Climate change-Land use and land use change | 6.599e-06 | 6.599e-06 | 1.000 | | Climate change | 1.147 | 1.147 | 1.000 | | EF-particulate Matter | 1.189e-09 | 1.189e-09 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.9653 | 0.9985 | 0.967 | | Ecotoxicity, freshwater_organics | 0.002749 | 0.002737 | 1.004 | | Ecotoxicity, freshwater | 0.968 | 1.001 | 0.967 | | Eutrophication marine | 1.886e-04 | 1.886e-04 | 1.000 | | Eutrophication, freshwater | 7.072e-06 | 7.072e-06 | 1.000 | | Eutrophication, terrestrial | 0.001204 | 0.001554 | 0.775 | | Human toxicity, cancer_inorganics | 5.117e-11 | 5.113e-11 | 1.001 | | Human toxicity, cancer_organics | 3.082e-12 | 3.082e-12 | 1.000 | | Human toxicity, cancer | 5.425e-11 | 5.422e-11 | 1.001 | | Human toxicity, non-cancer_inorganics | 2.231e-09 | 2.212e-09 | 1.008 | | Human toxicity, non-cancer_organics | 1.558e-11 | 1.558e-11 | 1.000 | | Human toxicity, non-cancer | 2.246e-09 | 2.228e-09 | 1.008 | | Ionising radiation, human health | 0.004698 | 0.004698 | 1.000 | | Land use | 0.135 | 0.08794 | 1.535 | | Ozone depletion | 9.929e-10 | 9.929e-10 | 1.000 | | Photochemical ozone formation - human health | 3.967e-04 | 3.967e-04 | 1.000 | | Resource use, fossils | 0.3994 | 0.3995 | 1.000 | | Resource use, minerals and metals | 4.727e-08 | 3.730e-08 | 1.267 | | Water use | 0.0341 | 0.03423 | 0.996 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 1.147 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 1202 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Disposal, polyethylene, 0.4% water, to municipal incineration [CH] | 0.2553 kg | ×0.899 / ×1.11 | lognormal, GSD² 1.11 | -6.8 / +7.6 | 7.6 (Climate change-Fossil) | | Disposal, plastics, mixture, 15.3% water, to municipal incineration [CH] | 0.08946 kg | ×0.899 / ×1.11 | lognormal, GSD² 1.11 | -1.9 / +2.1 | 4.9 (Ecotoxicity, freshwater_inorganics) | | Disposal, polyurethane, 0.2% water, to municipal incineration [CH] | 0.05613 kg | ×0.899 / ×1.11 | lognormal, GSD² 1.11 | -1.4 / +1.5 | 6.0 (Eutrophication marine) | | Transport, freight, lorry, 16t-32t gross weight, fleet average [CH] | 0.02923 tkm | ×0.504 / ×1.99 | lognormal, GSD² 2.01 | -0.2 / +0.4 | 36.4 (Ecotoxicity, freshwater_organics) | | Diesel, burned in building machine, average [CH] | 0.007523 MJ | ×0.899 / ×1.11 | lognormal, GSD² 1.11 | -0.0 / +0.0 | 1.9 (Human toxicity, non-cancer_organics) | | Excavation, hydraulic digger, average [CH] | 5.886e-04 m3 | ×0.899 / ×1.11 | lognormal, GSD² 1.11 | -0.0 / +0.0 | 0.8 (Human toxicity, non-cancer_organics) | | Disposal, inert waste, 5% water, to construction waste landfill [CH] | 0.2007 kg | ×0.899 / ×1.11 | lognormal, GSD² 1.11 | -0.0 / +0.0 | 7.2 (Eutrophication, freshwater) | | Shredding, electrical and electronic scrap [CH] | 0.02163 kg | ×0.899 / ×1.11 | lognormal, GSD² 1.11 | -0.0 / +0.0 | 0.8 (Ionising radiation, human health) | | Electricity, low voltage, consumer mix GO, at grid [CH] | 0.003684 kWh | ×0.899 / ×1.11 | lognormal, GSD² 1.11 | -0.0 / +0.0 | 5.0 (Ionising radiation, human health) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 1.147 kg CO2 eq per m2 (95 % interval 1.06–1.303). Dominant contributors: Disposal, polyethylene, 0.4% water, to municipal incineratio… 67 %; Disposal, plastics, mixture, 15.3% water, to municipal incin… 19 %; Disposal, polyurethane, 0.2% water, to municipal incineratio… 13 %. Most sensitive: Disposal, polyethylene, 0.4% water, to municipal incineration [CH] (-6.8 / +7.6 %); Disposal, plastics, mixture, 15.3% water, to municipal incineration [CH] (-1.9 / +2.1 %); Disposal, polyurethane, 0.2% water, to municipal incineration [CH] (-1.4 / +1.5 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 m2 | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.7e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 9/9 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 1.147 in [1.06, 1.303] | | time period declared | **PASS** | 2014-01/2014-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Klingler, Kasser (2011) Graue Energie von Sanitär- und Elektroanlagen. Project report. Page: 100. BfE. BfE. Type: Separate publication Source: Report First author: Klingler Other authors: Kasser Year: 2011 Title of anthology: Project report Place of publication: BfE Publisher: BfE — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].