====== Inverter, 2500W, at plant — RER ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:inverter_2500w_at_plant__rer|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Inverter, 2500W, at plant [RER], per 1 p. EF v3.1 climate change 145.6 kg CO2 eq (Monte Carlo 95 % interval 140.6–184.9). Main contributors: Steel, low-alloyed, at plant 14 %; Printed wiring board, through-hole, at plant 12 %; Integrated circuit, IC, logic type, at plant 12 %; Capacitor, film, through-hole mounting, at plant 10 %; Inductor, ring core choke type, at plant 9 %; Capacitor, electrolyte type, > 2cm height, at plant 7 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Inverter, 2500W, at plant | | Dataset UUID / graph id | ''%%39068f0a-81e9-31c5-af5a-77a40e87c99b%%'' / ''%%activity:inverter_2500w_at_plant__rer%%'' | | Reference product, unit | Inverter, 2500W, at plant, 1 p | | Location | RER — Production in RER. | | Time period | 1992-01/2006-12 | | Category | electronics / photovoltaic\infrastructure | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Production of an inverter (2500W) with an efficiency of 93.5% (total efficiency factor which includes MPP-Tracking) for photovoltaic plant. Total weight about 18.5 kg.; Synonyms: inverse rectifier; UUID: 39068f0a-81e9-31c5-af5a-77a40e87c99b This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Inverter, 2500W, at plant (RER). All results are given per unit of the reference flow. ==== System boundary ==== Materials, packaging and electricity use for the production of an inverse rectifier. Disposal of the product after use. ==== Technology ==== Inverter for a photovoltaic grid-connected system with a capacity of 2.5kWp. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Steel, low-alloyed, at plant | technosphere | RER | 9.8 | kg | lognormal, GSD² 1.22 | (2,3,1,1,1,5) | 14.4 | ███ | | | Printed wiring board, through-hole, at plant | technosphere | GLO | 0.2246 | m2 | lognormal, GSD² 1.22 | (2,3,1,1,1,5) | 11.7 | ██ | | | Integrated circuit, IC, logic type, at plant | technosphere | GLO | 0.028 | kg | lognormal, GSD² 1.22 | (2,3,1,1,1,5) | 11.6 | ██ | | | Capacitor, film, through-hole mounting, at plant | technosphere | GLO | 0.341 | kg | lognormal, GSD² 1.22 | (2,3,1,1,1,5) | 10.0 | ██ | | | Inductor, ring core choke type, at plant | technosphere | GLO | 0.351 | kg | lognormal, GSD² 1.22 | (2,3,1,1,1,5) | 9.3 | ██ | | | Capacitor, electrolyte type, > 2cm height, at plant | technosphere | GLO | 0.256 | kg | lognormal, GSD² 1.22 | (2,3,1,1,1,5) | 7.0 | █ | | | Copper, at regional storage | technosphere | RER | 5.51 | kg | lognormal, GSD² 1.22 | (2,3,1,1,1,5) | 6.1 | █ | | | Diode, glass-, through-hole mounting, at plant | technosphere | GLO | 0.047 | kg | lognormal, GSD² 1.22 | (2,3,1,1,1,5) | 6.1 | █ | | | Aluminium, production mix, cast alloy, at plant | technosphere | RER | 1.4 | kg | lognormal, GSD² 1.22 | (2,3,1,1,1,5) | 4.1 | █ | | | Electricity, medium voltage, production ENTSO-E, at grid | technosphere | ENTSO-E | 21.2 | kWh | lognormal, GSD² 1.31 | (2,3,4,1,1,5) | 4.0 | █ | | | Transistor, wired, small size, through-hole mounting, at plant | technosphere | GLO | 0.038 | kg | lognormal, GSD² 1.22 | (2,3,1,1,1,5) | 2.9 | █ | | | Capacitor, Tantalum-, through-hole mounting, at plant | technosphere | GLO | 0.023 | kg | lognormal, GSD² 1.22 | (2,3,1,1,1,5) | 2.6 | █ | | | Sheet rolling, steel | technosphere | RER | 9.8 | kg | lognormal, GSD² 1.22 | (2,3,1,1,1,5) | 2.5 | █ | | | Corrugated board, mixed fibre, single wall, at plant | technosphere | RER | 2.5 | kg | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.6 | · | | | Wire drawing, copper | technosphere | RER | 5.51 | kg | lognormal, GSD² 1.22 | (2,3,1,1,1,5) | 1.4 | · | | | Connector, clamp connection, at plant | technosphere | GLO | 0.237 | kg | lognormal, GSD² 1.22 | (2,3,1,1,1,5) | 1.1 | · | | | Section bar extrusion, aluminium | technosphere | RER | 1.4 | kg | lognormal, GSD² 1.22 | (2,3,1,1,1,5) | 0.7 | · | | | Polystyrene foam slab, at plant | technosphere | RER | 0.3 | kg | lognormal, GSD² 1.31 | (2,3,4,1,1,5) | 0.7 | · | | | Disposal, polystyrene, 0.2% water, to municipal incineration | technosphere | CH | 0.31 | kg | lognormal, GSD² 1.25 | (2,3,1,5,1,5) | 0.7 | · | | | Metal working factory | technosphere | RER | 8.9722e-09 | p | lognormal, GSD² 3.06 | (2,4,1,1,1,5) | 0.6 | · | | | Transport, freight, lorry, fleet average | technosphere | RER | 2.2996 | tkm | lognormal, GSD² 2.1 | — | 0.3 | · | | | Transport, transoceanic freight ship | technosphere | OCE | 36.271 | tkm | lognormal, GSD² 2.1 | — | 0.2 | · | | | Fleece, polyethylene, at plant | technosphere | RER | 0.06 | kg | lognormal, GSD² 1.31 | (2,3,4,1,1,5) | 0.1 | · | | | Disposal, polyethylene, 0.4% water, to municipal incineration | technosphere | CH | 0.06 | kg | lognormal, GSD² 1.25 | (2,3,1,5,1,5) | 0.1 | · | | | Disposal, treatment of printed wiring boards | technosphere | GLO | 1.7028 | kg | lognormal, GSD² 1.25 | (2,3,1,5,1,5) | 0.1 | · | | | Resistor, metal film type, through-hole mounting, at plant | technosphere | GLO | 0.005 | kg | lognormal, GSD² 1.22 | (2,3,1,1,1,5) | 0.1 | · | | | Transport, freight, rail | technosphere | RER | 7.1134 | tkm | lognormal, GSD² 2.1 | — | 0.1 | · | | | Disposal, packaging cardboard, 19.6% water, to municipal incineration | technosphere | CH | 2.5 | kg | lognormal, GSD² 1.25 | (2,3,1,5,1,5) | 0.1 | · | | | Styrene-acrylonitrile copolymer, SAN, at plant | technosphere | RER | 0.01 | kg | lognormal, GSD² 1.22 | (2,3,1,1,1,5) | 0.0 | · | | | Polyvinylchloride, at regional storage | technosphere | RER | 0.01 | kg | lognormal, GSD² 1.22 | (2,3,1,1,1,5) | 0.0 | · | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 76.32 | MJ | lognormal, GSD² 1.22 | (2,3,1,1,1,5) | 0.0 | · | | ==== Data quality ==== 28 of 31 direct exchanges carry a declared pedigree, 31 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.0 · completeness 3.07 · temporal 1.32 · geographical 1.57 · technological 1.0 · sample size 5.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Matthias Tuchschmid; data entry: Matthias Tuchschmid; validation (proof reading): Christian Bauer (PSI) | | extrapolations | Data for electronic components has been extrapolated from 500 W-Inverter | | sampling procedure | Detailed analysis of materials for one product | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: passed; Other validation: none; | | time period comment | undefined | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **1.587** | 1.406 | 2.117 | 1.24 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.6153** | 0.3815 | 1.589 | 2.05 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **144.9** | 139.7 | 184 | 1.16 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.08353** | 0.06928 | 0.1314 | 1.4 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **145.6** | 140.6 | 184.9 | 1.16 | | EF-particulate Matter | Impact on human health | disease incidence | **7.864e-06** | 7.681e-06 | 1.146e-05 | 1.23 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1126** | 1112 | 2157 | 1.43 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **49.51** | 41.65 | 85.16 | 1.46 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1176** | 1164 | 2223 | 1.41 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **0.1904** | 0.1744 | 0.3118 | 1.38 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **0.5418** | 0.3406 | 3.504 | 3.3 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **1.931** | 1.684 | 2.871 | 1.31 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.023e-07** | 1.960e-07 | 5.064e-07 | 1.67 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.457e-08** | 5.022e-08 | 9.105e-08 | 1.4 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.569e-07** | 2.568e-07 | 5.836e-07 | 1.54 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.757e-05** | 1.601e-05 | 4.537e-05 | 1.73 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.214e-06** | 8.440e-07 | 2.210e-06 | 1.63 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.878e-05** | 1.721e-05 | 4.671e-05 | 1.69 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **43.07** | 14.6 | 286.6 | 4.58 | | Land use | Soil quality index | pt (soil quality index) | **1360** | 1268 | 2212 | 1.34 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **5.019e-06** | 4.462e-06 | 7.702e-06 | 1.33 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **0.797** | 0.7479 | 1.122 | 1.23 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **1987** | 1901 | 2813 | 1.23 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.0448** | 0.0376 | 0.05676 | 1.23 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **19.43** | -6.111e+04 | 3.196e+04 | — | Climate change 145.6 kg CO2 eq per p. Main contributors: Steel, low-alloyed, at plant 14 %; Printed wiring board, through-hole, at plant 12 %; Integrated circuit, IC, logic type, at plant 12 %; Capacitor, film, through-hole mounting, at plant 10 %; Inductor, ring core choke type, at plant 9 %; Capacitor, electrolyte type, > 2cm height, at plant 7 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Steel, low-alloyed, at plant 14 %; Printed wiring board, through-hole, at plant 12 %; Integrated circuit, IC, logic type, at plant 12 %; Capacitor, film, through-hole mounting, at plant 10 %; Inductor, ring core choke type, at plant 9 %; Capacitor, electrolyte type, > 2cm height, at plant 7 %. Most sensitive exchanges (Section 6.3): Steel, low-alloyed, at plant [RER] (-2.6 / +3.1 %); Printed wiring board, through-hole, at plant [GLO] (-2.1 / +2.5 %); Integrated circuit, IC, logic type, at plant [GLO] (-2.1 / +2.5 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 1.587 | 1.645 | 0.965 | | Climate change-Biogenic | 0.6153 | 0.6153 | 1.000 | | Climate change-Fossil | 144.9 | 144.9 | 1.000 | | Climate change-Land use and land use change | 0.08353 | 0.08353 | 1.000 | | Climate change | 145.6 | 145.6 | 1.000 | | EF-particulate Matter | 7.864e-06 | 7.864e-06 | 1.000 | | Ecotoxicity, freshwater_inorganics | 1126 | 1155 | 0.975 | | Ecotoxicity, freshwater_organics | 49.51 | 47.52 | 1.042 | | Ecotoxicity, freshwater | 1176 | 1195 | 0.984 | | Eutrophication marine | 0.1904 | 0.1904 | 1.000 | | Eutrophication, freshwater | 0.5418 | 0.5418 | 1.000 | | Eutrophication, terrestrial | 1.931 | 2.009 | 0.961 | | Human toxicity, cancer_inorganics | 2.023e-07 | 2.012e-07 | 1.005 | | Human toxicity, cancer_organics | 5.457e-08 | 5.457e-08 | 1.000 | | Human toxicity, cancer | 2.569e-07 | 2.558e-07 | 1.004 | | Human toxicity, non-cancer_inorganics | 1.757e-05 | 1.751e-05 | 1.003 | | Human toxicity, non-cancer_organics | 1.214e-06 | 1.214e-06 | 1.000 | | Human toxicity, non-cancer | 1.878e-05 | 1.872e-05 | 1.003 | | Ionising radiation, human health | 43.07 | 43.07 | 1.000 | | Land use | 1360 | 1141 | 1.192 | | Ozone depletion | 5.019e-06 | 5.019e-06 | 1.000 | | Photochemical ozone formation - human health | 0.797 | 0.797 | 1.000 | | Resource use, fossils | 1987 | 1988 | 1.000 | | Resource use, minerals and metals | 0.0448 | 0.04461 | 1.004 | | Water use | 19.43 | 20.93 | 0.928 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 145.6 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 5.201e+05 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Steel, low-alloyed, at plant [RER] | 9.8 kg | ×0.821 / ×1.22 | lognormal, GSD² 1.22 | -2.6 / +3.1 | 3.9 (EF-particulate Matter) | | Printed wiring board, through-hole, at plant [GLO] | 0.2246 m2 | ×0.821 / ×1.22 | lognormal, GSD² 1.22 | -2.1 / +2.5 | 5.0 (Ecotoxicity, freshwater_inorganics) | | Integrated circuit, IC, logic type, at plant [GLO] | 0.028 kg | ×0.821 / ×1.22 | lognormal, GSD² 1.22 | -2.1 / +2.5 | 8.7 (Resource use, minerals and metals) | | Capacitor, film, through-hole mounting, at plant [GLO] | 0.341 kg | ×0.821 / ×1.22 | lognormal, GSD² 1.22 | -1.8 / +2.2 | 13.6 (Ecotoxicity, freshwater_organics) | | Inductor, ring core choke type, at plant [GLO] | 0.351 kg | ×0.821 / ×1.22 | lognormal, GSD² 1.22 | -1.7 / +2.0 | 2.5 (Photochemical ozone formation - human health) | | Capacitor, electrolyte type, > 2cm height, at plant [GLO] | 0.256 kg | ×0.821 / ×1.22 | lognormal, GSD² 1.22 | -1.3 / +1.5 | 2.3 (Climate change-Land use and land use change) | | Copper, at regional storage [RER] | 5.51 kg | ×0.821 / ×1.22 | lognormal, GSD² 1.22 | -1.1 / +1.3 | 15.6 (Human toxicity, non-cancer_organics) | | Diode, glass-, through-hole mounting, at plant [GLO] | 0.047 kg | ×0.821 / ×1.22 | lognormal, GSD² 1.22 | -1.1 / +1.3 | 1.7 (Climate change-Land use and land use change) | | Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] | 21.2 kWh | ×0.767 / ×1.3 | lognormal, GSD² 1.31 | -0.9 / +1.2 | 5.4 (Ionising radiation, human health) | | Aluminium, production mix, cast alloy, at plant [RER] | 1.4 kg | ×0.821 / ×1.22 | lognormal, GSD² 1.22 | -0.7 / +0.9 | 2.1 (Climate change-Land use and land use change) | | Metal working factory [RER] | 8.972e-09 p | ×0.334 / ×2.99 | lognormal, GSD² 3.06 | -0.4 / +1.2 | 16.1 (Land use) | | Transistor, wired, small size, through-hole mounting, at plant [GLO] | 0.038 kg | ×0.821 / ×1.22 | lognormal, GSD² 1.22 | -0.5 / +0.6 | 0.9 (Climate change-Land use and land use change) | | Capacitor, Tantalum-, through-hole mounting, at plant [GLO] | 0.023 kg | ×0.821 / ×1.22 | lognormal, GSD² 1.22 | -0.5 / +0.6 | 2.2 (Ozone depletion) | | Sheet rolling, steel [RER] | 9.8 kg | ×0.821 / ×1.22 | lognormal, GSD² 1.22 | -0.5 / +0.6 | 0.9 (Water use) | | Corrugated board, mixed fibre, single wall, at plant [RER] | 2.5 kg | ×0.808 / ×1.24 | lognormal, GSD² 1.24 | -0.3 / +0.4 | 2.2 (Land use) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 145.6 kg CO2 eq per p (95 % interval 140.6–184.9). Dominant contributors: Steel, low-alloyed, at plant 14 %; Printed wiring board, through-hole, at plant 12 %; Integrated circuit, IC, logic type, at plant 12 %; Capacitor, film, through-hole mounting, at plant 10 %; Inductor, ring core choke type, at plant 9 %; Capacitor, electrolyte type, > 2cm height, at plant 7 %. Most sensitive: Steel, low-alloyed, at plant [RER] (-2.6 / +3.1 %); Printed wiring board, through-hole, at plant [GLO] (-2.1 / +2.5 %); Integrated circuit, IC, logic type, at plant [GLO] (-2.1 / +2.5 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 5.8e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 23/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 31/31 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 145.6 in [140.6, 184.9] | | time period declared | **PASS** | 1992-01/2006-12 | | geography is a known location code | **PASS** | RER | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Jungbluth, N., Stucki, M., Frischknecht, R. (2009) Photovoltaics. Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent v2.1. Editors: Bauer C.. Volume: 6. Swiss Centre for LCI, PSI. Dübendorf and Villigen, CH. Type: Measurement on site Source: CD-ROM First author: Jungbluth, N. Other authors: Stucki, M., Frischknecht, R. Year: 2009 Name of editors: Bauer C. Title of anthology: Sachbilanz… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].