====== 3kWp slanted-roof installation, ribbon-Si, laminated, integrated, on roof — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:3kwp_slanted_roof_installation_ribbon_si_laminated_integrated_on_roof__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset 3kWp slanted-roof installation, ribbon-Si, laminated, integrated, on roof [CH], per 1 p. EF v3.1 climate change 3181 kg CO2 eq (Monte Carlo 95 % interval 2805–4525). Main contributors: Photovoltaic laminate, ribbon-Si, at plant 63 %; Slanted-roof construction, integrated, on roof 16 %; Inverter, 2500W, at plant 11 %; Electric installation, photovoltaic plant, at plant 4 %; Transport, freight, lorry, 3.5t gross weight, fleet average 3 %; Transport, freight, lorry, fleet average 2 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | 3kWp slanted-roof installation, ribbon-Si, laminated, integrated, on roof | | Dataset UUID / graph id | ''%%3b176199-fe1c-3d5a-8be1-00352bbc969f%%'' / ''%%activity:3kwp_slanted_roof_installation_ribbon_si_laminated_integrated_on_roof__ch%%'' | | Reference product, unit | 3kWp slanted-roof installation, ribbon-Si, laminated, integrated, on roof, 1 p | | Location | CH — Installation in CH | | Time period | 2005-01/2006-12 | | Category | photovoltaic / production of components | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Photovoltaic installation with a capacity of 3kWp and a life time of 30 years installed in CH.; Synonyms: polycrystalline, multi-crystalline, silicon; UUID: 3b176199-fe1c-3d5a-8be1-00352bbc969f This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of 3kWp slanted-roof installation, ribbon-Si, laminated, integrated, on roof (CH). All results are given per unit of the reference flow. ==== System boundary ==== All components for the installation of a 3kWp photovoltaic plant, energy use for the mounting, transport of materials and persons to the construction place. Disposal of components after end of life. ==== Technology ==== Current technology for mounting of panels or laminates, electric installations and other components. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Photovoltaic laminate, ribbon-Si, at plant | technosphere | RER | 24.671 | m2 | lognormal, GSD² 1.36 | (3,4,3,1,1,5) | 62.9 | █████████████ | | | Slanted-roof construction, integrated, on roof | technosphere | RER | 23.952 | m2 | lognormal, GSD² 1.23 | — | 16.2 | ███ | | | Inverter, 2500W, at plant | technosphere | RER | 2.4 | p | lognormal, GSD² 1.24 | — | 11.0 | ██ | | | Electric installation, photovoltaic plant, at plant | technosphere | CH | 1 | p | lognormal, GSD² 2.09 | (3,4,3,1,1,5) | 3.9 | █ | | | Transport, freight, lorry, 3.5t gross weight, fleet average | technosphere | CH | 91.913 | tkm | lognormal, GSD² 2.09 | (3,4,3,1,1,5) | 3.1 | █ | | | Transport, freight, lorry, fleet average | technosphere | RER | 413.71 | tkm | lognormal, GSD² 2.09 | (3,4,3,1,1,5) | 2.5 | · | | | Transport, transoceanic freight ship | technosphere | OCE | 1654.8 | tkm | lognormal, GSD² 2.09 | (3,4,3,1,1,5) | 0.4 | · | | | Electricity, low voltage, at grid | technosphere | CH | 0.04 | kWh | lognormal, GSD² 1.28 | (3,4,3,1,1,5) | 0.0 | · | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 0.144 | MJ | lognormal, GSD² 1.28 | (3,4,3,1,1,5) | 0.0 | · | | ==== Data quality ==== 7 of 9 direct exchanges carry a declared pedigree, 9 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.0 · completeness 4.0 · temporal 3.0 · geographical 1.0 · technological 1.0 · sample size 5.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Niels Jungbluth (ESU); data entry: Niels Jungbluth (ESU); validation (proof reading): Christian Bauer (PSI) | | extrapolations | Rough assumption for the decrease in material weights for mounting structures. | | sampling procedure | Publication for efficiency, mounting systems and own estimations for other components. | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: 27.04.2016; Other validation: \SRV01\ESU-Docs\Projekte laufend\174 Photovoltaic, IEA Task 12\2013 Global supply chain\EcoSpold[174-photovoltaics-global-supply-chain-v1.13.xlsx]X-Process; | | time period comment | Calculation of amount of panels used based on efficiency data for 2005. Other data are adopted. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **17.18** | 15.05 | 25.08 | 1.31 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **30.47** | 17.27 | 75.94 | 2.16 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **3148** | 2773 | 4476 | 1.29 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.931** | 1.593 | 2.961 | 1.38 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **3181** | 2805 | 4525 | 1.29 | | EF-particulate Matter | Impact on human health | disease incidence | **1.324e-04** | 1.141e-04 | 7.239e-04 | 2.44 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.619e+04** | 1.488e+04 | 3.117e+04 | 1.46 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **559.3** | 509.5 | 984.8 | 1.41 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.675e+04** | 1.554e+04 | 3.196e+04 | 1.45 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **3.799** | 3.31 | 5.802 | 1.33 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **3.505** | 2.354 | 18.77 | 2.81 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **29.9** | 26.44 | 47.21 | 1.35 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.496e-06** | 1.448e-06 | 4.049e-06 | 1.7 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.108e-06** | 9.002e-07 | 2.042e-06 | 1.52 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.605e-06** | 2.538e-06 | 5.701e-06 | 1.51 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.960e-04** | 1.596e-04 | 5.660e-04 | 1.94 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.594e-06** | 5.557e-06 | 1.419e-05 | 1.62 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.036e-04** | 1.660e-04 | 5.749e-04 | 1.91 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **1226** | 425.5 | 7656 | 4.56 | | Land use | Soil quality index | pt (soil quality index) | **2.281e+04** | 1.973e+04 | 3.8e+04 | 1.41 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **3.024e-04** | 2.161e-04 | 5.216e-04 | 1.6 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **15.35** | 13.08 | 23.43 | 1.34 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **4.751e+04** | 4.157e+04 | 7.347e+04 | 1.35 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.3891** | 0.3156 | 0.5149 | 1.29 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **490.9** | -1.143e+06 | 6.088e+05 | — | Climate change 3181 kg CO2 eq per p. Main contributors: Photovoltaic laminate, ribbon-Si, at plant 63 %; Slanted-roof construction, integrated, on roof 16 %; Inverter, 2500W, at plant 11 %; Electric installation, photovoltaic plant, at plant 4 %; Transport, freight, lorry, 3.5t gross weight, fleet average 3 %; Transport, freight, lorry, fleet average 2 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Photovoltaic laminate, ribbon-Si, at plant 63 %; Slanted-roof construction, integrated, on roof 16 %; Inverter, 2500W, at plant 11 %; Electric installation, photovoltaic plant, at plant 4 %; Transport, freight, lorry, 3.5t gross weight, fleet average 3 %; Transport, freight, lorry, fleet average 2 %. Most sensitive exchanges (Section 6.3): Photovoltaic laminate, ribbon-Si, at plant [RER] (-16.3 / +22.0 %); Slanted-roof construction, integrated, on roof [RER] (-3.0 / +3.6 %); Electric installation, photovoltaic plant, at plant [CH] (-2.0 / +4.2 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 17.18 | 18 | 0.955 | | Climate change-Biogenic | 30.47 | 30.47 | 1.000 | | Climate change-Fossil | 3148 | 3148 | 1.000 | | Climate change-Land use and land use change | 1.931 | 1.931 | 1.000 | | Climate change | 3181 | 3181 | 1.000 | | EF-particulate Matter | 1.324e-04 | 1.324e-04 | 1.000 | | Ecotoxicity, freshwater_inorganics | 1.619e+04 | 1.674e+04 | 0.967 | | Ecotoxicity, freshwater_organics | 559.3 | 482.9 | 1.158 | | Ecotoxicity, freshwater | 1.675e+04 | 1.718e+04 | 0.975 | | Eutrophication marine | 3.799 | 3.798 | 1.000 | | Eutrophication, freshwater | 3.505 | 3.505 | 1.000 | | Eutrophication, terrestrial | 29.9 | 32.59 | 0.918 | | Human toxicity, cancer_inorganics | 1.496e-06 | 1.475e-06 | 1.015 | | Human toxicity, cancer_organics | 1.108e-06 | 1.108e-06 | 1.000 | | Human toxicity, cancer | 2.605e-06 | 2.583e-06 | 1.008 | | Human toxicity, non-cancer_inorganics | 1.960e-04 | 1.952e-04 | 1.004 | | Human toxicity, non-cancer_organics | 7.594e-06 | 7.590e-06 | 1.000 | | Human toxicity, non-cancer | 2.036e-04 | 2.028e-04 | 1.004 | | Ionising radiation, human health | 1226 | 1226 | 1.000 | | Land use | 2.281e+04 | 1.815e+04 | 1.257 | | Ozone depletion | 3.024e-04 | 3.024e-04 | 1.000 | | Photochemical ozone formation - human health | 15.35 | 15.35 | 1.000 | | Resource use, fossils | 4.751e+04 | 4.753e+04 | 0.999 | | Resource use, minerals and metals | 0.3891 | 0.3871 | 1.005 | | Water use | 490.9 | 535.3 | 0.917 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 3180 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 7.124e+06 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Photovoltaic laminate, ribbon-Si, at plant [RER] | 24.67 m2 | ×0.741 / ×1.35 | lognormal, GSD² 1.36 | -16.3 / +22.0 | 31.8 (Climate change-Biogenic) | | Slanted-roof construction, integrated, on roof [RER] | 23.95 m2 | ×0.817 / ×1.22 | lognormal, GSD² 1.23 | -3.0 / +3.6 | 6.8 (Climate change-Land use and land use change) | | Electric installation, photovoltaic plant, at plant [CH] | 1 p | ×0.486 / ×2.06 | lognormal, GSD² 2.09 | -2.0 / +4.2 | 33.9 (Human toxicity, non-cancer_organics) | | Transport, freight, lorry, 3.5t gross weight, fleet average [CH] | 91.91 tkm | ×0.486 / ×2.06 | lognormal, GSD² 2.09 | -1.6 / +3.3 | 5.8 (Ecotoxicity, freshwater_organics) | | Inverter, 2500W, at plant [RER] | 2.4 p | ×0.813 / ×1.23 | lognormal, GSD² 1.24 | -2.1 / +2.5 | 8.8 (Human toxicity, non-cancer_organics) | | Transport, freight, lorry, fleet average [RER] | 413.7 tkm | ×0.486 / ×2.06 | lognormal, GSD² 2.09 | -1.3 / +2.6 | 16.4 (Climate change-Land use and land use change) | | Transport, transoceanic freight ship [OCE] | 1655 tkm | ×0.486 / ×2.06 | lognormal, GSD² 2.09 | -0.2 / +0.4 | 3.7 (Eutrophication, terrestrial) | | Electricity, low voltage, at grid [CH] | 0.04 kWh | ×0.782 / ×1.28 | lognormal, GSD² 1.28 | -0.0 / +0.0 | 0.0 (Ionising radiation, human health) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 3181 kg CO2 eq per p (95 % interval 2805–4525). Dominant contributors: Photovoltaic laminate, ribbon-Si, at plant 63 %; Slanted-roof construction, integrated, on roof 16 %; Inverter, 2500W, at plant 11 %; Electric installation, photovoltaic plant, at plant 4 %; Transport, freight, lorry, 3.5t gross weight, fleet average 3 %; Transport, freight, lorry, fleet average 2 %. Most sensitive: Photovoltaic laminate, ribbon-Si, at plant [RER] (-16.3 / +22.0 %); Slanted-roof construction, integrated, on roof [RER] (-3.0 / +3.6 %); Electric installation, photovoltaic plant, at plant [CH] (-2.0 / +4.2 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 4.1e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 9/9 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 3181 in [2805, 4525] | | time period declared | **PASS** | 2005-01/2006-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Itten R.,, Frischknecht R., (2013) LCI of global PV supply chain. Project report. Volume: 174. treeze Ltd.. Uster, CH. Type: Separate publication Source: Report First author: Itten R., Other authors: Frischknecht R., Year: 2013 Title of anthology: Project report Place of publication: Uster, CH Publisher: treeze Ltd. Volume No: 174 — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].