====== Single-Si wafer, photovoltaics, at plant — CN ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:single_si_wafer_photovoltaics_at_plant__cn|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Single-Si wafer, photovoltaics, at plant [CN], per 1 m2. EF v3.1 climate change 50.71 kg CO2 eq (Monte Carlo 95 % interval 40.58–69.15). Main contributors: CZ single crystalline silicon, photovoltaics, at plant 89 %; Electricity, medium voltage, at grid 7 %; Dipropylene glycol monomethyl ether, at plant 2 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Single-Si wafer, photovoltaics, at plant | | Dataset UUID / graph id | ''%%3b7aed12-7639-3aa8-bcb3-5a7d680aca9e%%'' / ''%%activity:single_si_wafer_photovoltaics_at_plant__cn%%'' | | Reference product, unit | Single-Si wafer, photovoltaics, at plant, 1 m2 | | Location | CN | | Time period | 1992-01/2021-12 | | Category | photovoltaic / production of components | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== The reference flow for the life cycle inventory is 1 square metre of wafer surface. The single-crystalline silicon ingots are sawn into square wafers with a size 156.75x156.75 mm2 (0.0244 m2), a thickness of 170 um and a weight of 396 g/m2. The sawing losses are 121 um (95 um kerf loss and 26 um additional losses such as pot scrap, ingot top, squaring, cropping etc.) or 282 g/m2. The diamond wire is modelled as a stainless steel wire because data on industrial diamond manufacture are missing. Water is used as a cutting fluid.; Synonyms: monocrystalline, single crystalline, silicon; UUID: 3b7aed12-7639-3aa8-bcb3-5a7d680aca9e This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 m2** of Single-Si wafer, photovoltaics, at plant (CN). All results are given per unit of the reference flow. ==== System boundary ==== Diamond sawing and cleaning of wafers. The process data include electricity use, water and working material consumption. Production wastes to be treated and process-specific waterborne pollutants are considered. No data on other process specific air emissions. ==== Technology ==== Use of diamond wire saws. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | CZ single crystalline silicon, photovoltaics, at plant | technosphere | CN | 0.59524 | kg | lognormal, GSD² 1.22 | (2,2,1,2,1,5) | 88.9 | ██████████████████ | | | Electricity, medium voltage, at grid | technosphere | CN | 4.7619 | kWh | lognormal, GSD² 2.05 | (2,2,1,2,1,5) | 6.7 | █ | | | Dipropylene glycol monomethyl ether, at plant | technosphere | RER | 0.29997 | kg | lognormal, GSD² 1.22 | (1,2,4,1,1,3) | 1.9 | · | | | Alkylbenzene sulfonate, linear, petrochemical, at plant | technosphere | RER | 0.23997 | kg | lognormal, GSD² 1.22 | (1,2,4,1,1,3) | 0.8 | · | | | Natural gas, burned in industrial furnace 1MW | technosphere | CH | 3.9982 | MJ | lognormal, GSD² 1.22 | (1,2,4,1,1,3) | 0.6 | · | | | Wafer factory | technosphere | DE | 3.9982e-06 | p | lognormal, GSD² 3.05 | (1,2,4,1,1,3) | 0.6 | · | | | Acetic acid, 98% in H2O, at plant | technosphere | RER | 0.038996 | kg | lognormal, GSD² 1.22 | (1,2,4,1,1,3) | 0.1 | · | | | Water, deionised, water balance according to MoeK 2013, at plant | technosphere | CN | 55.556 | kg | lognormal, GSD² 1.26 | (3,4,2,3,1,5) | 0.1 | · | | | Transport, freight, lorry, fleet average | technosphere | RER | 0.23587 | tkm | lognormal, GSD² 2.1 | — | 0.1 | · | | | Transport, freight, rail | technosphere | RER | 1.2465 | tkm | lognormal, GSD² 2.1 | — | 0.0 | · | | | Treatment, sewage, to wastewater treatment, class 2 | technosphere | CH | 0.05 | m3 | lognormal, GSD² 1.26 | (3,4,2,3,1,5) | 0.0 | · | | | Brass, at plant | technosphere | CH | 0.0074375 | kg | lognormal, GSD² 1.22 | (1,2,4,1,1,3) | 0.0 | · | | | Disposal, waste, silicon wafer production, 0% water, to underground deposit | technosphere | DE | 0.11012 | kg | lognormal, GSD² 1.22 | (1,2,4,1,1,3) | 0.0 | · | | | Flat glass, uncoated, at plant | technosphere | RER | 0.0099852 | kg | lognormal, GSD² 1.26 | (3,4,2,3,1,5) | 0.0 | · | | | Sodium hydroxide, 50% in H2O, production mix, at plant | technosphere | RER | 0.014998 | kg | lognormal, GSD² 1.22 | (1,2,4,1,1,3) | 0.0 | · | | | Chromium steel 18/8, at plant | technosphere | RER | 0.0015105 | kg | lognormal, GSD² 1.32 | (3,2,1,1,3,5) | 0.0 | · | | | Wire drawing, steel | technosphere | RER | 0.008948 | kg | lognormal, GSD² 1.32 | (3,2,1,1,3,5) | 0.0 | · | | | Acrylic binder, 34% in H2O, at plant | technosphere | RER | 0.0020012 | kg | lognormal, GSD² 1.22 | (1,2,4,1,1,3) | 0.0 | · | | | Hydrochloric acid, 30% in H2O, at plant | technosphere | RER | 0.0026997 | kg | lognormal, GSD² 1.22 | (1,2,4,1,1,3) | 0.0 | · | | | Chemical Oxygen Demand | elementary | water/Surface water | 0.011095 | kg | lognormal, GSD² 1.85 | (3,4,5,3,1,5) | 0.0 | · | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 17.143 | MJ | lognormal, GSD² 1.34 | (3,4,4,3,1,5) | 0.0 | · | | | Water vapour | elementary | air/Unknown | 0.0055556 | m3 | lognormal, GSD² 1.65 | — | 0.0 | · | | | Biological Oxygen Demand | elementary | water/River | 0.029545 | kg | lognormal, GSD² 1.85 | (3,4,5,3,1,5) | 0.0 | · | | | Total Organic Carbon | elementary | water/River | 0.011095 | kg | lognormal, GSD² 1.85 | (3,4,5,3,1,5) | 0.0 | · | | | Chemical Oxygen Demand | elementary | water/Surface water | 0.029545 | kg | lognormal, GSD² 1.64 | (3,4,5,3,1,5) | 0.0 | · | | ==== Data quality ==== 22 of 25 direct exchanges carry a declared pedigree, 25 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.0 · completeness 2.73 · temporal 3.36 · geographical 1.82 · technological 1.18 · sample size 4.09. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Philippe Stolz (TREEZE); data entry: Philippe Stolz (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | Extrapolation of European LCI data by changing the electricity mix. | | sampling procedure | Data collection by factory representatives. Environmental report and LCA studies. | | production volume | Approximately 105000 MW for total c-Si in 2018 | | uncertainty adjustments | | | validation details | Proof reading validation: 30.09.2020; Other validation: G:\Projekte laufend\174 Photovoltaic, IEA Task 12\2017 Global supply chain\EcoSpold[174-photovoltaics-global-supply-chain-v2.5.xlsx]X-Process; | | time period comment | Collection of data in 2005. Use of some data from older publications. Silicon demand, electricity consumption as well as diamond wire and water demand updated for 2018. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 m2. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **0.09332** | 0.08025 | 0.1428 | 1.34 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.3921** | 0.2478 | 0.8483 | 1.89 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **50.31** | 40.23 | 68.37 | 1.32 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.009465** | 0.007504 | 0.01606 | 1.48 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **50.71** | 40.58 | 69.15 | 1.32 | | EF-particulate Matter | Impact on human health | disease incidence | **9.796e-07** | 8.626e-07 | 1.819e-06 | 1.45 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **521.2** | 411 | 964.8 | 1.55 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.088** | 1.776 | 5.57 | 1.77 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **523.3** | 413.1 | 968.8 | 1.55 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **0.09856** | 0.07606 | 0.1528 | 1.43 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **0.01447** | 0.009681 | 0.05494 | 2.43 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **0.3117** | 0.2633 | 0.5101 | 1.4 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.111e-08** | 8.751e-09 | 4.260e-08 | 2.33 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.567e-08** | 1.133e-08 | 2.533e-08 | 1.54 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.678e-08** | 2.221e-08 | 6.263e-08 | 1.73 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.003e-07** | 5.330e-07 | 2.633e-06 | 2.4 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.427e-08** | 1.263e-08 | 2.482e-08 | 1.43 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **7.145e-07** | 5.465e-07 | 2.653e-06 | 2.37 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **9.052** | 2.218 | 66.95 | 5.8 | | Land use | Soil quality index | pt (soil quality index) | **312.2** | 228.6 | 584.9 | — | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **1.791e-06** | 1.270e-06 | 3.377e-06 | 1.61 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **0.09342** | 0.07988 | 0.1516 | 1.39 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **655** | 515.8 | 1003 | 1.41 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **8.661e-05** | 6.690e-05 | 2.010e-04 | 1.72 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **137.7** | -1.446e+04 | 8442 | — | Climate change 50.71 kg CO2 eq per m2. Main contributors: CZ single crystalline silicon, photovoltaics, at plant 89 %; Electricity, medium voltage, at grid 7 %; Dipropylene glycol monomethyl ether, at plant 2 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: CZ single crystalline silicon, photovoltaics, at plant 89 %; Electricity, medium voltage, at grid 7 %; Dipropylene glycol monomethyl ether, at plant 2 %. Most sensitive exchanges (Section 6.3): CZ single crystalline silicon, photovoltaics, at plant [CN] (-15.6 / +18.9 %); Electricity, medium voltage, at grid [CN] (-3.4 / +6.9 %); Wafer factory [DE] (-0.4 / +1.1 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 0.09332 | 0.1014 | 0.920 | | Climate change-Biogenic | 0.3921 | 0.3921 | 1.000 | | Climate change-Fossil | 50.31 | 50.31 | 1.000 | | Climate change-Land use and land use change | 0.009465 | 0.009465 | 1.000 | | Climate change | 50.71 | 50.71 | 1.000 | | EF-particulate Matter | 9.796e-07 | 9.796e-07 | 1.000 | | Ecotoxicity, freshwater_inorganics | 521.2 | 523.9 | 0.995 | | Ecotoxicity, freshwater_organics | 2.088 | 2.071 | 1.008 | | Ecotoxicity, freshwater | 523.3 | 525.8 | 0.995 | | Eutrophication marine | 0.09856 | 0.09856 | 1.000 | | Eutrophication, freshwater | 0.01447 | 0.01447 | 1.000 | | Eutrophication, terrestrial | 0.3117 | 0.3166 | 0.985 | | Human toxicity, cancer_inorganics | 1.111e-08 | 1.107e-08 | 1.004 | | Human toxicity, cancer_organics | 1.567e-08 | 1.567e-08 | 1.000 | | Human toxicity, cancer | 2.678e-08 | 2.674e-08 | 1.002 | | Human toxicity, non-cancer_inorganics | 7.003e-07 | 6.976e-07 | 1.004 | | Human toxicity, non-cancer_organics | 1.427e-08 | 1.427e-08 | 1.000 | | Human toxicity, non-cancer | 7.145e-07 | 7.118e-07 | 1.004 | | Ionising radiation, human health | 9.052 | 9.052 | 1.000 | | Land use | 312.2 | 231.6 | 1.348 | | Ozone depletion | 1.791e-06 | 1.791e-06 | 1.000 | | Photochemical ozone formation - human health | 0.09342 | 0.09342 | 1.000 | | Resource use, fossils | 655 | 655 | 1.000 | | Resource use, minerals and metals | 8.661e-05 | 5.586e-05 | 1.551 | | Water use | 137.7 | 137.8 | 0.999 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 50.71 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 9.784e+04 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | CZ single crystalline silicon, photovoltaics, at plant [CN] | 0.5952 kg | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -15.6 / +18.9 | 20.7 (Water use) | | Electricity, medium voltage, at grid [CN] | 4.762 kWh | ×0.494 / ×2.02 | lognormal, GSD² 2.05 | -3.4 / +6.9 | 7.1 (Human toxicity, cancer_organics) | | Wafer factory [DE] | 3.998e-06 p | ×0.335 / ×2.98 | lognormal, GSD² 3.05 | -0.4 / +1.1 | 17.2 (Resource use, minerals and metals) | | Dipropylene glycol monomethyl ether, at plant [RER] | 0.3 kg | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.3 / +0.4 | 7.9 (Ecotoxicity, freshwater_inorganics) | | Alkylbenzene sulfonate, linear, petrochemical, at plant [RER] | 0.24 kg | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.1 / +0.2 | 0.5 (Resource use, minerals and metals) | | Natural gas, burned in industrial furnace 1MW [CH] | 3.998 MJ | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.1 / +0.1 | 0.2 (Ecotoxicity, freshwater_organics) | | Transport, freight, lorry, fleet average [RER] | 0.2359 tkm | ×0.484 / ×2.06 | lognormal, GSD² 2.1 | -0.0 / +0.1 | 1.9 (Climate change-Land use and land use change) | | Transport, freight, rail [RER] | 1.246 tkm | ×0.484 / ×2.06 | lognormal, GSD² 2.1 | -0.0 / +0.0 | 0.5 (Human toxicity, non-cancer_organics) | | Water, deionised, water balance according to MoeK 2013, at plant [CN] | 55.56 kg | ×0.795 / ×1.26 | lognormal, GSD² 1.26 | -0.0 / +0.0 | 0.5 (Water use) | | Acetic acid, 98% in H2O, at plant [RER] | 0.039 kg | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.0 / +0.0 | 0.4 (Human toxicity, non-cancer_organics) | | Treatment, sewage, to wastewater treatment, class 2 [CH] | 0.05 m3 | ×0.795 / ×1.26 | lognormal, GSD² 1.26 | -0.0 / +0.0 | 0.3 (Eutrophication marine) | | Brass, at plant [CH] | 0.007437 kg | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.0 / +0.0 | 1.8 (Resource use, minerals and metals) | | Disposal, waste, silicon wafer production, 0% water, to underground deposit [DE] | 0.1101 kg | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.0 / +0.0 | 0.0 (EF-particulate Matter) | | Flat glass, uncoated, at plant [RER] | 0.009985 kg | ×0.795 / ×1.26 | lognormal, GSD² 1.26 | -0.0 / +0.0 | 0.0 (Acidification) | | Chromium steel 18/8, at plant [RER] | 0.00151 kg | ×0.76 / ×1.32 | lognormal, GSD² 1.32 | -0.0 / +0.0 | 0.1 (Resource use, minerals and metals) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== ^ Source ^ Scope ^ Value ^ This dataset ^ Ratio ^ Note ^ | bafu | Single-Si wafer, photovoltaics, at plant [RER] | 30.67 kg CO2 eq | 50.71 | 1.65 | same dataset name, other location | | bafu | Single-Si wafer, photovoltaics, at plant [US] | 33.56 kg CO2 eq | 50.71 | 1.51 | same dataset name, other location | | bafu | Single-Si wafer, photovoltaics, at plant [APAC] | 45.23 kg CO2 eq | 50.71 | 1.12 | same dataset name, other location | ==== Conclusions and limitations ==== GWP100 50.71 kg CO2 eq per m2 (95 % interval 40.58–69.15). Dominant contributors: CZ single crystalline silicon, photovoltaics, at plant 89 %; Electricity, medium voltage, at grid 7 %; Dipropylene glycol monomethyl ether, at plant 2 %. Most sensitive: CZ single crystalline silicon, photovoltaics, at plant [CN] (-15.6 / +18.9 %); Electricity, medium voltage, at grid [CN] (-3.4 / +6.9 %); Wafer factory [DE] (-0.4 / +1.1 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 m2 | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.5e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 22/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 25/25 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 50.71 in [40.58, 69.15] | | time period declared | **PASS** | 1992-01/2021-12 | | geography is a known location code | **PASS** | CN | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 1 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Frischknecht Rolf Stolz Philippe Krebs Luana de Wild-Scholten Mariska Sinha Parikhit (2020). Task 12 PV Sustainability - Life Cycle Inventories and Life Cycle Assessments of Photovoltaic Systems. Office of Scientific and Technical Information (OSTI). https://doi.org/10.2172/2308831 — //published source; matched in Crossref (author, year ±1, title overlap)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].