====== Cogen unit 160kWe, components for heat only — RER ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:cogen_unit_160kwe_components_for_heat_only__rer|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Cogen unit 160kWe, components for heat only [RER], per 1 p. EF v3.1 climate change 1.485e+04 kg CO2 eq (Monte Carlo 95 % interval 1.165e+04–2.486e+04). Main contributors: Storage 10000 l 56 %; Heating, sanitary equipment cogen unit 160kWe 27 %; Heat exchanger of cogen unit 160kWe 18 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Cogen unit 160kWe, components for heat only | | Dataset UUID / graph id | ''%%41b4ff40-63f9-3f17-88d0-61564aa2f2cc%%'' / ''%%activity:cogen_unit_160kwe_components_for_heat_only__rer%%'' | | Reference product, unit | Cogen unit 160kWe, components for heat only, 1 p | | Location | RER — Data refers to a plant in Switzerland, assumed valid for Europe (RER) | | Time period | 1990-01/2000-12 | | Category | heat / natural gas\cogeneration\power unit\infrastructure | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== The module summarises infrastructure components of a cogeneration unit. ; UUID: 41b4ff40-63f9-3f17-88d0-61564aa2f2cc This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Cogen unit 160kWe, components for heat only (RER). All results are given per unit of the reference flow. ==== System boundary ==== The module includes all components related exclusively to heat production. ==== Technology ==== Infrastructure of a specific cogeneration unit installed in Switzerland. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Storage 10000 l | technosphere | RER | 2 | p | lognormal, GSD² 1.3 | — | 55.6 | ███████████ | | | Heating, sanitary equipment cogen unit 160kWe | technosphere | RER | 1 | p | lognormal, GSD² 1.3 | — | 26.6 | █████ | | | Heat exchanger of cogen unit 160kWe | technosphere | RER | 1.25 | p | lognormal, GSD² 1.7 | — | 17.8 | ████ | | ==== Data quality ==== 0 of 3 direct exchanges carry a declared pedigree, 3 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Thomas Heck; data entry: Thomas Heck; validation (proof reading): Gerald Rebitzer | | extrapolations | see Geography/Text | | sampling procedure | Operator and manufacturer information | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: passed; Other validation: none; | | time period comment | undefined | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **36.67** | 29.6 | 61.88 | 1.48 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **51.47** | 28.02 | 153.3 | 2.38 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.479e+04** | 1.16e+04 | 2.466e+04 | 1.48 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **7.812** | 6.005 | 14.6 | 1.61 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.485e+04** | 1.165e+04 | 2.486e+04 | 1.48 | | EF-particulate Matter | Impact on human health | disease incidence | **7.213e-04** | 5.319e-04 | 0.00146 | 1.69 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **3.574e+04** | 2.943e+04 | 8.809e+04 | 1.77 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1804** | 1459 | 4135 | 1.84 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **3.754e+04** | 3.127e+04 | 9.055e+04 | 1.76 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **9.906** | 8.145 | 17.55 | 1.49 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **5.265** | 3.436 | 18.86 | 2.35 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **93.8** | 76.76 | 170.2 | 1.51 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **8.460e-06** | 6.667e-06 | 2.589e-05 | 1.97 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.495e-06** | 4.089e-06 | 1.075e-05 | 1.65 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.396e-05** | 1.152e-05 | 3.410e-05 | 1.74 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.063e-04** | 2.470e-04 | 9.052e-04 | 1.98 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **6.069e-06** | 5.084e-06 | 1.237e-05 | 1.6 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **3.123e-04** | 2.527e-04 | 9.152e-04 | 1.96 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **4882** | 1719 | 3.23e+04 | 4.52 | | Land use | Soil quality index | pt (soil quality index) | **6.113e+04** | 4.977e+04 | 1.327e+05 | 1.62 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **3.511e-04** | 2.815e-04 | 7.811e-04 | 1.67 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **43.22** | 35.37 | 82.9 | 1.56 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **1.851e+05** | 1.466e+05 | 3.356e+05 | 1.52 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.07302** | 0.05371 | 0.1333 | 1.61 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **1962** | -4.575e+06 | 2.782e+06 | — | Climate change 1.485e+04 kg CO2 eq per p. Main contributors: Storage 10000 l 56 %; Heating, sanitary equipment cogen unit 160kWe 27 %; Heat exchanger of cogen unit 160kWe 18 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Storage 10000 l 56 %; Heating, sanitary equipment cogen unit 160kWe 27 %; Heat exchanger of cogen unit 160kWe 18 %. Most sensitive exchanges (Section 6.3): Storage 10000 l [RER] (-12.6 / +16.3 %); Heat exchanger of cogen unit 160kWe [RER] (-7.2 / +12.1 %); Heating, sanitary equipment cogen unit 160kWe [RER] (-6.0 / +7.8 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 36.67 | 43.95 | 0.834 | | Climate change-Biogenic | 51.47 | 51.47 | 1.000 | | Climate change-Fossil | 1.479e+04 | 1.479e+04 | 1.000 | | Climate change-Land use and land use change | 7.812 | 7.812 | 1.000 | | Climate change | 1.485e+04 | 1.485e+04 | 1.000 | | EF-particulate Matter | 7.213e-04 | 7.213e-04 | 1.000 | | Ecotoxicity, freshwater_inorganics | 3.574e+04 | 3.747e+04 | 0.954 | | Ecotoxicity, freshwater_organics | 1804 | 1797 | 1.004 | | Ecotoxicity, freshwater | 3.754e+04 | 3.919e+04 | 0.958 | | Eutrophication marine | 9.906 | 9.905 | 1.000 | | Eutrophication, freshwater | 5.265 | 5.265 | 1.000 | | Eutrophication, terrestrial | 93.8 | 99.67 | 0.941 | | Human toxicity, cancer_inorganics | 8.460e-06 | 8.393e-06 | 1.008 | | Human toxicity, cancer_organics | 5.495e-06 | 5.495e-06 | 1.000 | | Human toxicity, cancer | 1.396e-05 | 1.389e-05 | 1.005 | | Human toxicity, non-cancer_inorganics | 3.063e-04 | 3.040e-04 | 1.007 | | Human toxicity, non-cancer_organics | 6.069e-06 | 6.069e-06 | 1.000 | | Human toxicity, non-cancer | 3.123e-04 | 3.101e-04 | 1.007 | | Ionising radiation, human health | 4882 | 4882 | 1.000 | | Land use | 6.113e+04 | 4.754e+04 | 1.286 | | Ozone depletion | 3.511e-04 | 3.511e-04 | 1.000 | | Photochemical ozone formation - human health | 43.22 | 43.22 | 1.000 | | Resource use, fossils | 1.851e+05 | 1.852e+05 | 0.999 | | Resource use, minerals and metals | 0.07302 | 0.07188 | 1.016 | | Water use | 1962 | 2110 | 0.930 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 1.484e+04 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 2.808e+07 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Storage 10000 l [RER] | 2 p | ×0.773 / ×1.29 | lognormal, GSD² 1.3 | -12.6 / +16.3 | 20.7 (Water use) | | Heat exchanger of cogen unit 160kWe [RER] | 1.25 p | ×0.595 / ×1.68 | lognormal, GSD² 1.7 | -7.2 / +12.1 | 19.8 (Resource use, minerals and metals) | | Heating, sanitary equipment cogen unit 160kWe [RER] | 1 p | ×0.773 / ×1.29 | lognormal, GSD² 1.3 | -6.0 / +7.8 | 16.3 (Ozone depletion) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 1.485e+04 kg CO2 eq per p (95 % interval 1.165e+04–2.486e+04). Dominant contributors: Storage 10000 l 56 %; Heating, sanitary equipment cogen unit 160kWe 27 %; Heat exchanger of cogen unit 160kWe 18 %. Most sensitive: Storage 10000 l [RER] (-12.6 / +16.3 %); Heat exchanger of cogen unit 160kWe [RER] (-7.2 / +12.1 %); Heating, sanitary equipment cogen unit 160kWe [RER] (-6.0 / +7.8 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 1.7e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 3/3 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 1.485e+04 in [1.165e+04, 2.486e+04] | | time period declared | **PASS** | 1990-01/2000-12 | | geography is a known location code | **PASS** | RER | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Heck, T. (2007) Wärme-Kraft-Kopplung. Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0. Editors: Dones R.. Volume: 6. Swiss Centre for LCI, PSI. Dübendorf and Villigen, CH. Type: Measurement on site Source: CD-ROM First author: Heck, T. Year: 2007 Name of editors: Dones R. Title of anthology: Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0 Place of … — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].