====== Cogen unit 500kWe, common components for heat+electricity — RER ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:cogen_unit_500kwe_common_components_for_heat_plus_electricity__rer|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Cogen unit 500kWe, common components for heat+electricity [RER], per 1 p. EF v3.1 climate change 1.246e+05 kg CO2 eq (Monte Carlo 95 % interval 1.051e+05–1.748e+05). Main contributors: Maintenance, cogen unit 160kWe 40 %; Control cabinet cogen unit 160kWe 21 %; Planning, cogen unit 160kWe 11 %; Gas motor 206kW 10 %; Assembly, module cogen unit 160kWe 5 %; Supply air input/spent air output cogen unit 160kWe 5 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Cogen unit 500kWe, common components for heat+electricity | | Dataset UUID / graph id | ''%%45c791f5-5a60-3adc-ae26-47483b103813%%'' / ''%%activity:cogen_unit_500kwe_common_components_for_heat_plus_electricity__rer%%'' | | Reference product, unit | Cogen unit 500kWe, common components for heat+electricity, 1 p | | Location | RER — Extrapolated from data of a plant in Switzerland, assumed valid for Europe (RER). | | Time period | 1990-01/2000-12 | | Category | heat / natural gas\cogeneration\power unit\infrastructure | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== The module summarises infrastructure components of a cogeneration unit. ; UUID: 45c791f5-5a60-3adc-ae26-47483b103813 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Cogen unit 500kWe, common components for heat+electricity (RER). All results are given per unit of the reference flow. ==== System boundary ==== The module includes all shared components for heat and electricity production. ==== Technology ==== Extrapolated from data of a 160kWe lambda=1 plant, adjusted to lean burn technology currently available on market, no catalytic converters. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Maintenance, cogen unit 160kWe | technosphere | RER | 1.8 | p | lognormal, GSD² 1.5 | — | 40.4 | ████████ | | | Control cabinet cogen unit 160kWe | technosphere | RER | 1.7 | p | lognormal, GSD² 1.5 | — | 21.2 | ████ | | | Planning, cogen unit 160kWe | technosphere | RER | 1.7 | p | lognormal, GSD² 1.5 | — | 10.7 | ██ | | | Gas motor 206kW | technosphere | RER | 2.78 | p | lognormal, GSD² 1.7 | — | 9.7 | ██ | | | Assembly, module cogen unit 160kWe | technosphere | RER | 1.7 | p | lognormal, GSD² 1.5 | — | 5.5 | █ | | | Supply air input/spent air output cogen unit 160kWe | technosphere | RER | 1.7 | p | lognormal, GSD² 1.5 | — | 4.7 | █ | | | Sound insulation cogen unit 160kWe | technosphere | RER | 1.7 | p | lognormal, GSD² 1.5 | — | 4.4 | █ | | | Construction work, cogen unit 160kWe | technosphere | RER | 1.7 | p | lognormal, GSD² 1.5 | — | 3.4 | █ | | | Operation start, cogen unit 160kWe | technosphere | RER | 1.7 | p | lognormal, GSD² 1.5 | — | 0.1 | · | | ==== Data quality ==== 0 of 9 direct exchanges carry a declared pedigree, 9 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Thomas Heck; data entry: Thomas Heck; validation (proof reading): Gerald Rebitzer | | extrapolations | see Geography/Text, see Technolgy Text | | sampling procedure | Operator and manufacturer information | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: passed; Other validation: none; | | time period comment | undefined | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **184.3** | 162 | 274.2 | 1.32 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **396.9** | 227.4 | 1030 | 2.11 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.242e+05** | 1.047e+05 | 1.742e+05 | 1.3 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **30.07** | 25.23 | 49.91 | 1.41 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.246e+05** | 1.051e+05 | 1.748e+05 | 1.3 | | EF-particulate Matter | Impact on human health | disease incidence | **0.002457** | 0.002085 | 0.004464 | 1.48 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.763e+05** | 2.069e+05 | 7.060e+05 | 1.88 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.054e+04** | 8903 | 2.075e+04 | 1.65 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.868e+05** | 2.185e+05 | 7.210e+05 | 1.85 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **54.61** | 48.64 | 82.38 | 1.32 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **28.76** | 17.61 | 101.8 | 2.46 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **502** | 446.2 | 762 | 1.34 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.822e-05** | 2.492e-05 | 8.058e-05 | 1.86 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.329e-05** | 2.713e-05 | 6.124e-05 | 1.52 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **6.151e-05** | 5.601e-05 | 1.307e-04 | 1.54 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **0.001825** | 0.001327 | 0.006137 | 2.24 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **4.851e-05** | 4.028e-05 | 8.409e-05 | 1.45 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **0.001873** | 0.001383 | 0.006204 | 2.2 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **3.128e+04** | 1.126e+04 | 2.064e+05 | 4.41 | | Land use | Soil quality index | pt (soil quality index) | **3.591e+05** | 3.129e+05 | 6.282e+05 | 1.45 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **0.003234** | 0.00266 | 0.005336 | 1.43 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **301.8** | 246.6 | 505.2 | 1.46 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **1.758e+06** | 1.484e+06 | 2.554e+06 | 1.34 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.3415** | 0.2821 | 0.5851 | 1.44 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **7298** | -2.336e+07 | 1.279e+07 | — | Climate change 1.246e+05 kg CO2 eq per p. Main contributors: Maintenance, cogen unit 160kWe 40 %; Control cabinet cogen unit 160kWe 21 %; Planning, cogen unit 160kWe 11 %; Gas motor 206kW 10 %; Assembly, module cogen unit 160kWe 5 %; Supply air input/spent air output cogen unit 160kWe 5 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Maintenance, cogen unit 160kWe 40 %; Control cabinet cogen unit 160kWe 21 %; Planning, cogen unit 160kWe 11 %; Gas motor 206kW 10 %; Assembly, module cogen unit 160kWe 5 %; Supply air input/spent air output cogen unit 160kWe 5 %. Most sensitive exchanges (Section 6.3): Maintenance, cogen unit 160kWe [RER] (-13.2 / +19.7 %); Control cabinet cogen unit 160kWe [RER] (-6.9 / +10.3 %); Gas motor 206kW [RER] (-3.9 / +6.6 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 184.3 | 247.8 | 0.744 | | Climate change-Biogenic | 396.9 | 396.9 | 1.000 | | Climate change-Fossil | 1.242e+05 | 1.242e+05 | 1.000 | | Climate change-Land use and land use change | 30.07 | 30.07 | 1.000 | | Climate change | 1.246e+05 | 1.246e+05 | 1.000 | | EF-particulate Matter | 0.002457 | 0.002457 | 1.000 | | Ecotoxicity, freshwater_inorganics | 2.763e+05 | 2.818e+05 | 0.980 | | Ecotoxicity, freshwater_organics | 1.054e+04 | 1.048e+04 | 1.006 | | Ecotoxicity, freshwater | 2.868e+05 | 2.920e+05 | 0.982 | | Eutrophication marine | 54.61 | 54.6 | 1.000 | | Eutrophication, freshwater | 28.76 | 28.76 | 1.000 | | Eutrophication, terrestrial | 502 | 544.8 | 0.921 | | Human toxicity, cancer_inorganics | 2.822e-05 | 2.770e-05 | 1.019 | | Human toxicity, cancer_organics | 3.329e-05 | 3.329e-05 | 1.000 | | Human toxicity, cancer | 6.151e-05 | 6.099e-05 | 1.008 | | Human toxicity, non-cancer_inorganics | 0.001825 | 0.001809 | 1.009 | | Human toxicity, non-cancer_organics | 4.851e-05 | 4.850e-05 | 1.000 | | Human toxicity, non-cancer | 0.001873 | 0.001857 | 1.009 | | Ionising radiation, human health | 3.128e+04 | 3.128e+04 | 1.000 | | Land use | 3.591e+05 | 3.047e+05 | 1.178 | | Ozone depletion | 0.003234 | 0.003234 | 1.000 | | Photochemical ozone formation - human health | 301.8 | 301.8 | 1.000 | | Resource use, fossils | 1.758e+06 | 1.758e+06 | 1.000 | | Resource use, minerals and metals | 0.3415 | 0.3376 | 1.012 | | Water use | 7298 | 8127 | 0.898 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 1.246e+05 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 1.962e+08 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Maintenance, cogen unit 160kWe [RER] | 1.8 p | ×0.672 / ×1.49 | lognormal, GSD² 1.5 | -13.2 / +19.7 | 22.2 (Water use) | | Control cabinet cogen unit 160kWe [RER] | 1.7 p | ×0.672 / ×1.49 | lognormal, GSD² 1.5 | -6.9 / +10.3 | 13.6 (Resource use, minerals and metals) | | Gas motor 206kW [RER] | 2.78 p | ×0.595 / ×1.68 | lognormal, GSD² 1.7 | -3.9 / +6.6 | 38.6 (Human toxicity, non-cancer_inorganics) | | Planning, cogen unit 160kWe [RER] | 1.7 p | ×0.672 / ×1.49 | lognormal, GSD² 1.5 | -3.5 / +5.2 | 7.6 (Climate change-Biogenic) | | Assembly, module cogen unit 160kWe [RER] | 1.7 p | ×0.672 / ×1.49 | lognormal, GSD² 1.5 | -1.8 / +2.7 | 5.3 (Climate change-Biogenic) | | Supply air input/spent air output cogen unit 160kWe [RER] | 1.7 p | ×0.672 / ×1.49 | lognormal, GSD² 1.5 | -1.5 / +2.3 | 5.2 (Climate change-Land use and land use change) | | Sound insulation cogen unit 160kWe [RER] | 1.7 p | ×0.672 / ×1.49 | lognormal, GSD² 1.5 | -1.5 / +2.2 | 6.4 (Human toxicity, cancer_inorganics) | | Construction work, cogen unit 160kWe [RER] | 1.7 p | ×0.672 / ×1.49 | lognormal, GSD² 1.5 | -1.1 / +1.6 | 3.4 (Climate change-Land use and land use change) | | Operation start, cogen unit 160kWe [RER] | 1.7 p | ×0.672 / ×1.49 | lognormal, GSD² 1.5 | -0.0 / +0.0 | 0.3 (Climate change-Land use and land use change) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 1.246e+05 kg CO2 eq per p (95 % interval 1.051e+05–1.748e+05). Dominant contributors: Maintenance, cogen unit 160kWe 40 %; Control cabinet cogen unit 160kWe 21 %; Planning, cogen unit 160kWe 11 %; Gas motor 206kW 10 %; Assembly, module cogen unit 160kWe 5 %; Supply air input/spent air output cogen unit 160kWe 5 %. Most sensitive: Maintenance, cogen unit 160kWe [RER] (-13.2 / +19.7 %); Control cabinet cogen unit 160kWe [RER] (-6.9 / +10.3 %); Gas motor 206kW [RER] (-3.9 / +6.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 4.1e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 9/9 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 1.246e+05 in [1.051e+05, 1.748e+05] | | time period declared | **PASS** | 1990-01/2000-12 | | geography is a known location code | **PASS** | RER | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Heck, T. (2007) Wärme-Kraft-Kopplung. Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0. Editors: Dones R.. Volume: 6. Swiss Centre for LCI, PSI. Dübendorf and Villigen, CH. Type: Measurement on site Source: CD-ROM First author: Heck, T. Year: 2007 Name of editors: Dones R. Title of anthology: Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0 Place of … — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].