====== Hydrogen, gaseous, 25 bar, from electrolysis, from label-certified electricity — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:hydrogen_gaseous_25_bar_from_electrolysis_from_label_certified_electricity__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Hydrogen, gaseous, 25 bar, from electrolysis, from label-certified electricity [CH], per 1 kg. EF v3.1 climate change 0.8485 kg CO2 eq (Monte Carlo 95 % interval 0.7137–1.424). Main contributors: Electricity, low voltage, certified electricity, at grid 94 %; PEM electrolyzer, Operation and Maintenance 4 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Hydrogen, gaseous, 25 bar, from electrolysis, from label-certified electricity | | Dataset UUID / graph id | ''%%47b70b94-f94d-3f2d-9a3e-0d65ef735e2c%%'' / ''%%activity:hydrogen_gaseous_25_bar_from_electrolysis_from_label_certified_electricity__ch%%'' | | Reference product, unit | Hydrogen, gaseous, 25 bar, from electrolysis, from label-certified electricity, 1 kg | | Location | CH | | Time period | 2020-01/2020-12 | | Category | fuels / hydrogen\Transformation | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Hydrogen production by electrolysis. Output pressure of 25 bar. The electricity mix to operate the electrolyzer can be adapted. Assumed 58 kWh/kg H2. Original source: X. Zhang, C. Bauer, C.L. Mutel, K. Volkart, Life Cycle Assessment of Power-to-Gas: Approaches, system variations and their environmental implications, Appl Energy, 190 (2017), pp. 326-338, 10.1016/j.apenergy.2016.12.098. UUID: 47b70b94-f94d-3f2d-9a3e-0d65ef735e2c This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kg** of Hydrogen, gaseous, 25 bar, from electrolysis, from label-certified electricity (CH). All results are given per unit of the reference flow. ==== System boundary ==== — ==== Technology ==== Hydrogen production by electrolysis. Output pressure of 25 bar. The electricity mix to operate the electrolyzer can be adapted. Assumed 58 kWh/kg H2. Original source: X. Zhang, C. Bauer, C.L. Mutel, K. Volkart, Life Cycle Assessment of Power-to-Gas: Approaches, system variations and their environmental implications, Appl Energy, 190 (2017), pp. 326-338, 10.1016/j.apenergy.2016.12.098 ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electricity, low voltage, certified electricity, at grid | technosphere | CH | 55 | kWh | lognormal, GSD² 1.13 | (3,3,2,2,1,3) | 93.9 | ███████████████████ | | | PEM electrolyzer, Operation and Maintenance | technosphere | RER | 0.0185 | hr | lognormal, GSD² 1.13 | (3,3,2,2,1,3) | 3.8 | █ | | | PEM electrolyzer, Stack | technosphere | GLO | 8.1900e-06 | p | lognormal, GSD² 1.13 | (3,3,2,2,1,3) | 0.9 | · | | | Water, deionised, at plant | technosphere | CH | 12.3 | kg | lognormal, GSD² 1.13 | (3,3,2,2,1,3) | 0.7 | · | | | PEM electrolyzer, Balance of Plant | technosphere | GLO | 2.9700e-06 | p | lognormal, GSD² 1.13 | (3,3,2,2,1,3) | 0.3 | · | | | PEM electrolyzer, ACDC Converter | technosphere | GLO | 2.9700e-06 | p | lognormal, GSD² 1.13 | (3,3,2,2,1,3) | 0.2 | · | | | Diaphragm compressor module, high pressure | technosphere | GLO | 1.6900e-07 | p | lognormal, GSD² 1.13 | (3,3,2,2,1,3) | 0.2 | · | | ==== Data quality ==== 7 of 7 direct exchanges carry a declared pedigree, 7 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.0 · completeness 3.0 · temporal 2.0 · geographical 2.0 · technological 1.0 · sample size 3.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Romain Sacchi (PSI); data entry: Julien McTighe (INFRAS); validation (proof reading): Brian Cox (INFRAS) | | time period comment | Base technology year of 2020 | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kg. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **0.006186** | 0.003683 | 0.01571 | 2.16 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.04493** | 0.03233 | 0.06604 | 1.44 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.7591** | 0.6319 | 1.324 | 1.47 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.04445** | 0.02808 | 0.07026 | 1.6 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.8485** | 0.7137 | 1.424 | 1.43 | | EF-particulate Matter | Impact on human health | disease incidence | **5.232e-08** | 4.223e-08 | 1.107e-07 | 1.64 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **4.528** | 3.84 | 11.87 | 1.8 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.05638** | 0.05148 | 0.1519 | 1.84 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **4.585** | 3.902 | 12 | 1.79 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **8.627e-04** | 6.895e-04 | 0.001988 | 1.72 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **0.001652** | 8.421e-04 | 0.01151 | 4.03 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **0.01123** | 0.008836 | 0.02188 | 1.6 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.047e-09** | 7.496e-10 | 3.961e-09 | 2.31 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.655e-10** | 4.005e-10 | 1.088e-09 | 1.68 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.613e-09** | 1.275e-09 | 4.698e-09 | 1.93 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **6.500e-08** | 4.024e-08 | 2.875e-07 | 2.75 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.221e-09** | 2.522e-09 | 1.533e-08 | 2.52 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **7.022e-08** | 4.334e-08 | 2.960e-07 | 2.7 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.1582** | 0.06396 | 1.194 | 4.38 | | Land use | Soil quality index | pt (soil quality index) | **25.63** | 16.17 | 47.19 | 1.73 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **1.819e-08** | 1.475e-08 | 4.227e-08 | 1.69 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **0.003003** | 0.002445 | 0.006242 | 1.63 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **6.201** | 5.354 | 12.33 | 1.54 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **5.672e-05** | 2.838e-05 | 1.715e-04 | 2.53 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.2418** | -1864 | 850.1 | — | Climate change 0.8485 kg CO2 eq per kg. Main contributors: Electricity, low voltage, certified electricity, at grid 94 %; PEM electrolyzer, Operation and Maintenance 4 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electricity, low voltage, certified electricity, at grid 94 %; PEM electrolyzer, Operation and Maintenance 4 %. Most sensitive exchanges (Section 6.3): Electricity, low voltage, certified electricity, at grid [CH] (-10.6 / +11.9 %); PEM electrolyzer, Operation and Maintenance [RER] (-0.4 / +0.5 %); PEM electrolyzer, Stack [GLO] (-0.1 / +0.1 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 0.006186 | 0.008988 | 0.688 | | Climate change-Biogenic | 0.04493 | 0.04493 | 1.000 | | Climate change-Fossil | 0.7591 | 0.7591 | 1.000 | | Climate change-Land use and land use change | 0.04445 | 0.04445 | 1.000 | | Climate change | 0.8485 | 0.8485 | 1.000 | | EF-particulate Matter | 5.232e-08 | 5.232e-08 | 1.000 | | Ecotoxicity, freshwater_inorganics | 4.528 | 4.616 | 0.981 | | Ecotoxicity, freshwater_organics | 0.05638 | 0.05366 | 1.051 | | Ecotoxicity, freshwater | 4.585 | 4.659 | 0.984 | | Eutrophication marine | 8.627e-04 | 8.627e-04 | 1.000 | | Eutrophication, freshwater | 0.001652 | 0.001652 | 1.000 | | Eutrophication, terrestrial | 0.01123 | 0.01098 | 1.022 | | Human toxicity, cancer_inorganics | 1.047e-09 | 1.045e-09 | 1.002 | | Human toxicity, cancer_organics | 5.655e-10 | 5.655e-10 | 1.000 | | Human toxicity, cancer | 1.613e-09 | 1.610e-09 | 1.002 | | Human toxicity, non-cancer_inorganics | 6.500e-08 | 6.485e-08 | 1.002 | | Human toxicity, non-cancer_organics | 5.221e-09 | 5.221e-09 | 1.000 | | Human toxicity, non-cancer | 7.022e-08 | 7.008e-08 | 1.002 | | Ionising radiation, human health | 0.1582 | 0.1582 | 1.000 | | Land use | 25.63 | 19.34 | 1.325 | | Ozone depletion | 1.819e-08 | 1.819e-08 | 1.000 | | Photochemical ozone formation - human health | 0.003003 | 0.003003 | 1.000 | | Resource use, fossils | 6.201 | 6.203 | 1.000 | | Resource use, minerals and metals | 5.672e-05 | 5.647e-05 | 1.004 | | Water use | 0.2418 | 0.2574 | 0.940 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.8452 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 4688 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Electricity, low voltage, certified electricity, at grid [CH] | 55 kWh | ×0.888 / ×1.13 | lognormal, GSD² 1.13 | -10.6 / +11.9 | 12.7 (Climate change-Land use and land use change) | | PEM electrolyzer, Operation and Maintenance [RER] | 0.0185 hr | ×0.888 / ×1.13 | lognormal, GSD² 1.13 | -0.4 / +0.5 | 0.7 (Resource use, fossils) | | PEM electrolyzer, Stack [GLO] | 8.190e-06 p | ×0.888 / ×1.13 | lognormal, GSD² 1.13 | -0.1 / +0.1 | 1.2 (Human toxicity, non-cancer_organics) | | Water, deionised, at plant [CH] | 12.3 kg | ×0.888 / ×1.13 | lognormal, GSD² 1.13 | -0.1 / +0.1 | 8.4 (Water use) | | PEM electrolyzer, Balance of Plant [GLO] | 2.970e-06 p | ×0.888 / ×1.13 | lognormal, GSD² 1.13 | -0.0 / +0.0 | 0.1 (Resource use, fossils) | | PEM electrolyzer, ACDC Converter [GLO] | 2.970e-06 p | ×0.888 / ×1.13 | lognormal, GSD² 1.13 | -0.0 / +0.0 | 0.2 (Human toxicity, non-cancer_inorganics) | | Diaphragm compressor module, high pressure [GLO] | 1.690e-07 p | ×0.888 / ×1.13 | lognormal, GSD² 1.13 | -0.0 / +0.0 | 0.0 (Resource use, fossils) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.8485 kg CO2 eq per kg (95 % interval 0.7137–1.424). Dominant contributors: Electricity, low voltage, certified electricity, at grid 94 %; PEM electrolyzer, Operation and Maintenance 4 %. Most sensitive: Electricity, low voltage, certified electricity, at grid [CH] (-10.6 / +11.9 %); PEM electrolyzer, Operation and Maintenance [RER] (-0.4 / +0.5 %); PEM electrolyzer, Stack [GLO] (-0.1 / +0.1 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kg | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.7e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 7/7 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.8485 in [0.7137, 1.424] | | time period declared | **PASS** | 2020-01/2020-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 1 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Sacchi R., Bauer C. (2021). Life cycle inventories for on-road vehicles. Zenodo. https://doi.org/10.5281/ZENODO.5156043 — //published source; DOI resolved at doi.org// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].