====== Disposal, ventilation system, Geschäftshaus C, Esslingen, special components — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:disposal_ventilation_system_gesch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Disposal, ventilation system, Geschäftshaus C, Esslingen, special components [CH], per 1 p. EF v3.1 climate change 76.96 kg CO2 eq (Monte Carlo 95 % interval 67.78–97.87). Main contributors: Disposal, building, electric wiring, to final disposal 39 %; Disposal, building, fibre board, to final disposal 22 %; Disposal, electronics for control units 20 %; Disposal, polystyrene, 0.2% water, to municipal incineration 19 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Disposal, ventilation system, Geschäftshaus C, Esslingen, special components | | Dataset UUID / graph id | ''%%483c8d29-e040-414a-a1ca-c50e74ab577e%%'' / ''%%activity:disposal_ventilation_system_geschäftshaus_c_esslingen_special_components__ch%%'' | | Reference product, unit | Disposal, ventilation system, Geschäftshaus C, Esslingen, special components, 1 p | | Location | CH — Specific to the technology mix encountered in sorting plants in Switzerland. | | Time period | 2014-01/2014-12 | | Category | waste management / building demolition | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Disposal of special components of a ventilation system for an office building with offices only (no kitchen, restaurant or car park). The inventory is based on a building with a total heated gross floor area of 2621 m2 and a total nominal air flow of 4000 m3/h, total weight of the components: 121 kg/Unit, building with a specific air flow rate of 1.5 m3/h per m2 heated gross floor area. Data from call of bid including decental ventilation units between circulation area and offices. Components including fans, wiring and transformer but without surrounding light-weight wall.; UUID: 483c8d29-e040-414a-a1ca-c50e74ab577e This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Disposal, ventilation system, Geschäftshaus C, Esslingen, special components (CH). All results are given per unit of the reference flow. ==== System boundary ==== Transport to dismantling facilities, machines for handling in sorting plant, electricity demand for sorting plant, final disposal of waste material. Cut-off to recycling for metals. ==== Technology ==== Disposal to a sorting plant assumed. Metal pieces, copper in cables and electronic devices are recycled, plastic parts are incinerated, inert wastes (e.g. rock wool) are landfilled. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Disposal, building, electric wiring, to final disposal | technosphere | CH | 22 | kg | lognormal, GSD² 1.34 | (3,4,1,1,3,5) | 39.4 | ████████ | | | Disposal, building, fibre board, to final disposal | technosphere | CH | 76.5 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 22.1 | ████ | | | Disposal, electronics for control units | technosphere | RER | 13.6 | kg | lognormal, GSD² 1.34 | (3,4,1,1,3,5) | 19.7 | ████ | | | Disposal, polystyrene, 0.2% water, to municipal incineration | technosphere | CH | 4.5 | kg | lognormal, GSD² 1.34 | (3,4,1,1,3,5) | 18.7 | ████ | | | Disposal, building, bulk iron (excluding reinforcement), to sorting plant | technosphere | CH | 4 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.0 | · | | ==== Data quality ==== 5 of 5 direct exchanges carry a declared pedigree, 5 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.0 · completeness 4.0 · temporal 1.0 · geographical 1.0 · technological 2.2 · sample size 5.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU) | | extrapolations | none | | sampling procedure | Waste-specific calculation based on production input data | | production volume | na | | uncertainty adjustments | none | | time period comment | Amount of material investigated in 2013. Disposal technology mix as used in late 1990ies | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **0.02063** | 0.01687 | 0.04556 | 1.67 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.01257** | 0.008891 | 0.03164 | 1.91 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **76.95** | 67.76 | 97.85 | 1.21 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.004412** | 0.002623 | 0.01074 | 2.04 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **76.96** | 67.78 | 97.87 | 1.21 | | EF-particulate Matter | Impact on human health | disease incidence | **2.826e-07** | 2.407e-07 | 5.746e-07 | 1.55 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1185** | 852.7 | 1787 | 1.47 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.6912** | 0.5599 | 1.629 | 1.77 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1186** | 853.4 | 1788 | 1.47 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **0.02487** | 0.01847 | 0.05985 | 1.86 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **0.00141** | 9.857e-04 | 0.02744 | 5.61 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **0.1689** | 0.1168 | 0.46 | 2.04 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **8.505e-09** | 7.917e-09 | 3.676e-08 | 2.16 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **9.926e-10** | 9.020e-10 | 1.920e-09 | 1.48 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **9.498e-09** | 9.093e-09 | 3.800e-08 | 2.05 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **6.774e-07** | 5.400e-07 | 2.700e-06 | 2.23 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.835e-09** | 2.529e-09 | 5.892e-09 | 1.53 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **6.803e-07** | 5.443e-07 | 2.704e-06 | 2.23 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **1.04** | 0.4027 | 7.218 | 4.27 | | Land use | Soil quality index | pt (soil quality index) | **40.01** | 34.61 | 66.49 | 1.4 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **2.116e-07** | 1.847e-07 | 4.291e-07 | 1.53 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **0.05774** | 0.04093 | 0.147 | 1.94 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **79.62** | 68.22 | 180.8 | 1.63 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **1.761e-05** | 1.385e-05 | 4.260e-05 | 1.78 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **38.05** | -641.7 | 401.8 | — | Climate change 76.96 kg CO2 eq per p. Main contributors: Disposal, building, electric wiring, to final disposal 39 %; Disposal, building, fibre board, to final disposal 22 %; Disposal, electronics for control units 20 %; Disposal, polystyrene, 0.2% water, to municipal incineration 19 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Disposal, building, electric wiring, to final disposal 39 %; Disposal, building, fibre board, to final disposal 22 %; Disposal, electronics for control units 20 %; Disposal, polystyrene, 0.2% water, to municipal incineration 19 %. Most sensitive exchanges (Section 6.3): Disposal, building, electric wiring, to final disposal [CH] (-9.8 / +13.1 %); Disposal, electronics for control units [RER] (-4.9 / +6.5 %); Disposal, polystyrene, 0.2% water, to municipal incineration [CH] (-4.7 / +6.2 %). ==== Independent recalculation ==== The publisher publishes no LCIA result for this dataset; the closure check of Section 7 is the recalculation test. ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Disposal, building, electric wiring, to final disposal [CH] | 22 kg | ×0.751 / ×1.33 | lognormal, GSD² 1.34 | -9.8 / +13.1 | 30.3 (Water use) | | Disposal, electronics for control units [RER] | 13.6 kg | ×0.751 / ×1.33 | lognormal, GSD² 1.34 | -4.9 / +6.5 | 27.6 (Climate change-Land use and land use change) | | Disposal, polystyrene, 0.2% water, to municipal incineration [CH] | 4.5 kg | ×0.751 / ×1.33 | lognormal, GSD² 1.34 | -4.7 / +6.2 | 6.2 (Climate change-Fossil) | | Disposal, building, fibre board, to final disposal [CH] | 76.5 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -4.5 / +5.6 | 16.9 (Eutrophication marine) | | Disposal, building, bulk iron (excluding reinforcement), to sorting plant [CH] | 4 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.0 / +0.0 | 0.2 (Ionising radiation, human health) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 76.96 kg CO2 eq per p (95 % interval 67.78–97.87). Dominant contributors: Disposal, building, electric wiring, to final disposal 39 %; Disposal, building, fibre board, to final disposal 22 %; Disposal, electronics for control units 20 %; Disposal, polystyrene, 0.2% water, to municipal incineration 19 %. Most sensitive: Disposal, building, electric wiring, to final disposal [CH] (-9.8 / +13.1 %); Disposal, electronics for control units [RER] (-4.9 / +6.5 %); Disposal, polystyrene, 0.2% water, to municipal incineration [CH] (-4.7 / +6.2 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.0e-16 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 5/5 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 76.96 in [67.78, 97.87] | | time period declared | **PASS** | 2014-01/2014-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].