====== Electricity, production mix photovoltaic, at plant — TR ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:electricity_production_mix_photovoltaic_at_plant__tr|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity, production mix photovoltaic, at plant [TR], per 1 kWh. EF v3.1 climate change 0.02021 kg CO2 eq (Monte Carlo 95 % interval 0.01599–0.04329). Main contributors: 570 kWp open ground installation, multi-Si, on open ground 63 %; 570 kWp open ground installation, single-Si, on open ground 33 %; 570 kWp open ground installation, CIS, on open ground 2 %; 570 kWp open ground installation, CdTe, on open ground 2 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Electricity, production mix photovoltaic, at plant | | Dataset UUID / graph id | ''%%4a76104d-e61b-372b-ae59-d2d8cc2d24e0%%'' / ''%%activity:electricity_production_mix_photovoltaic_at_plant__tr%%'' | | Reference product, unit | Electricity, production mix photovoltaic, at plant, 1 kWh | | Location | TR — undefined | | Time period | 2005-01/2018-12 | | Category | electricity by fuel / photovoltaic | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Annual output of grid-connected PV power plants differentiated for roof-top, facade and centralized power plants. Technology and installation type breakdown based on literature (IEA-PVPS Task 1 and Fraunhofer ISE reports) and expert estimates. Average yield based on population-weighted average according to Breyer & Schmid (2010), corrected by performance ratio as specified in IEA-PVPS Task 12 methodology guidelines. The lifetime of PV systems is estimated at 30 years based on the PEFCR PV electricity. Technology: Electricity production with grid-connected photovoltaic power plants. Time period: Time of publications Version: 1 Energy values: Undefined 100.0 Production volume: Unknown. Local category: Photovoltaik Local subcategory: Kraftwerke UVEK 2022 source file:174-photovoltaics-global-supply-chain-v2.5._X-elec-RER.xml UUID: 4a76104d-e61b-372b-ae59-d2d8cc2d24e0 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kWh** of Electricity, production mix photovoltaic, at plant (TR). All results are given per unit of the reference flow. ==== System boundary ==== Production mix of photovoltaic electricity in the country. Annual output, Roof-Top: 1388, Annual output, Facade: 971 kWh/kWp, Annual output, centralized PV systems: 1471 kWh/kWp. Amount of solar energy transformed to electricity. Waste heat emission due to losses of electricity in the system. ==== Technology ==== Electricity production with grid-connected photovoltaic power plants. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | 570 kWp open ground installation, multi-Si, on open ground | technosphere | RER | 2.4784e-08 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 63.2 | █████████████ | | | 570 kWp open ground installation, single-Si, on open ground | technosphere | RER | 1.3126e-08 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 32.9 | ███████ | | | 570 kWp open ground installation, CIS, on open ground | technosphere | RER | 7.7450e-10 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 1.8 | · | | | 570 kWp open ground installation, CdTe, on open ground | technosphere | RER | 9.3755e-10 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 1.6 | · | | | 570 kWp open ground installation, micro-Si, on open ground | technosphere | RER | 1.2229e-10 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.5 | · | | | Treatment, sewage, from residence, to wastewater treatment, class 2 | technosphere | CH | 2.2193e-06 | m3 | lognormal, GSD² 1.09 | (2,2,1,1,1,3) | 0.0 | · | | | Tap water, water balance according to MoeK 2013, at user | technosphere | TR | 0.0024659 | kg | lognormal, GSD² 1.09 | (2,2,1,1,1,3) | 0.0 | · | | | 156 kWp flat-roof installation, multi-Si, on roof | technosphere | CH | 4.2300e-12 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | 93 kWp slanted-roof installation, multi-Si, panel, mounted, on roof | technosphere | CH | 7.8839e-12 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | 3kWp flat roof installation, multi-Si, on roof | technosphere | RER | 1.0998e-10 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | 156 kWp flat-roof installation, single-Si, on roof | technosphere | CH | 2.2402e-12 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | 93 kWp slanted-roof installation, single-Si, panel, mounted, on roof | technosphere | CH | 4.1753e-12 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | 3kWp slanted-roof installation, multi-Si, panel, mounted, on roof | technosphere | RER | 9.0276e-11 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | 3kWp flat roof installation, single-Si, on roof | technosphere | RER | 5.8246e-11 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | 3kWp slanted-roof installation, single-Si, panel, mounted, on roof | technosphere | RER | 4.7810e-11 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | 3kWp slanted-roof installation, CIS, panel, mounted, on roof | technosphere | CH | 2.0618e-11 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | 3kWp slanted-roof installation, CdTe, panel, mounted, on roof | technosphere | CH | 2.4959e-11 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | 3kWp facade installation, multi-Si, panel, mounted, at building | technosphere | RER | 1.0474e-11 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | 93 kWp slanted-roof installation, multi-Si, laminated, integrated, on roof | technosphere | CH | 4.7303e-13 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | 3kWp facade installation, multi-Si, laminated, integrated, at building | technosphere | RER | 1.0474e-11 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | 3kWp facade installation, single-Si, panel, mounted, at building | technosphere | RER | 5.5472e-12 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | 93 kWp slanted-roof installation, single-Si, laminated, integrated, on roof | technosphere | CH | 2.5052e-13 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | 3kWp slanted-roof installation, micro-Si, panel, mounted, on roof | technosphere | RER | 3.2555e-12 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | 3kWp facade installation, single-Si, laminated, integrated, at building | technosphere | RER | 5.5472e-12 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | 3kWp slanted-roof installation, multi-Si, laminated, integrated, on roof | technosphere | RER | 5.4165e-12 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | 3kWp slanted-roof installation, single-Si, laminated, integrated, on roof | technosphere | RER | 2.8686e-12 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | 3kWp slanted-roof installation, CdTe, laminated, integrated, on roof | technosphere | CH | 1.4975e-12 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | 3kWp slanted-roof installation, CIS, laminated, integrated, on roof | technosphere | CH | 1.2371e-12 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | 3kWp slanted-roof installation, micro-Si, laminated, integrated, on roof | technosphere | RER | 1.9533e-13 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | Energy, Solar, Converted | elementary | natural resource | 3.8503 | MJ | lognormal, GSD² 1.09 | (2,2,1,1,1,3) | 0.0 | · | | | Water vapour | elementary | air/Unknown | 2.4659e-07 | m3 | lognormal, GSD² 1.51 | — | 0.0 | · | | | Waste Heat | elementary | air/Unknown | 0.25027 | MJ | lognormal, GSD² 1.05 | — | 0.0 | · | | ==== Data quality ==== 30 of 32 direct exchanges carry a declared pedigree, 32 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.0 · completeness 2.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 3.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Philippe Stolz (TREEZE); data entry: Philippe Stolz (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | Use of PV technology data investigated for other countries (Switzerland). Correction of average yield with Swiss data. | | sampling procedure | Statistical data and model calculations | | production volume | na | | uncertainty adjustments | | | validation details | Proof reading validation: 30.09.2020; Other validation: G:\Projekte laufend\174 Photovoltaic, IEA Task 12\2017 Global supply chain\EcoSpold[174-photovoltaics-global-supply-chain-v2.5.xlsx]X-Process; | | time period comment | Time of publications | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **8.711e-05** | 7.351e-05 | 1.824e-04 | 1.59 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **8.895e-05** | 5.416e-05 | 3.070e-04 | 2.45 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.02011** | 0.01592 | 0.04298 | 1.7 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.614e-05** | 1.286e-05 | 3.012e-05 | 1.56 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.02021** | 0.01599 | 0.04329 | 1.71 | | EF-particulate Matter | Impact on human health | disease incidence | **8.067e-10** | 7.107e-10 | 4.496e-09 | 2.48 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.1096** | 0.09058 | 0.3346 | 1.97 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.002431** | 0.002096 | 0.006251 | 1.79 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.112** | 0.09304 | 0.3409 | 1.96 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **2.441e-05** | 1.971e-05 | 5.534e-05 | 1.73 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **9.840e-06** | 7.736e-06 | 5.241e-05 | 2.7 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **1.953e-04** | 1.637e-04 | 4.238e-04 | 1.62 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **8.741e-12** | 7.789e-12 | 3.272e-11 | 2.06 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.533e-12** | 4.468e-12 | 1.368e-11 | 1.82 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.427e-11** | 1.345e-11 | 4.160e-11 | 1.84 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **4.457e-10** | 4.460e-10 | 1.456e-09 | 1.86 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.146e-11** | 1.680e-11 | 4.546e-11 | 1.65 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **4.672e-10** | 4.686e-10 | 1.488e-09 | 1.83 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.005555** | 0.001903 | 0.04445 | 5 | | Land use | Soil quality index | pt (soil quality index) | **5.682** | 3.975 | 10.01 | 1.6 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **6.146e-10** | 4.847e-10 | 1.691e-09 | 1.85 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **6.082e-05** | 5.256e-05 | 1.362e-04 | 1.62 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.268** | 0.217 | 0.6078 | 1.73 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **6.760e-07** | 4.484e-07 | 1.603e-06 | 1.95 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.01018** | -6.047 | 2.936 | — | Climate change 0.02021 kg CO2 eq per kWh. Main contributors: 570 kWp open ground installation, multi-Si, on open ground 63 %; 570 kWp open ground installation, single-Si, on open ground 33 %; 570 kWp open ground installation, CIS, on open ground 2 %; 570 kWp open ground installation, CdTe, on open ground 2 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: 570 kWp open ground installation, multi-Si, on open ground 63 %; 570 kWp open ground installation, single-Si, on open ground 33 %; 570 kWp open ground installation, CIS, on open ground 2 %; 570 kWp open ground installation, CdTe, on open ground 2 %. Most sensitive exchanges (Section 6.3): 570 kWp open ground installation, multi-Si, on open ground [RER] (-11.0 / +13.4 %); 570 kWp open ground installation, single-Si, on open ground [RER] (-5.7 / +7.0 %); 570 kWp open ground installation, CIS, on open ground [RER] (-0.3 / +0.4 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh: ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 8.711e-05 | 9.138e-05 | 0.953 | | Climate change-Biogenic | 8.895e-05 | 8.895e-05 | 1.000 | | Climate change-Fossil | 0.02011 | 0.02011 | 1.000 | | Climate change-Land use and land use change | 1.614e-05 | 1.614e-05 | 1.000 | | Climate change | 0.02021 | 0.02021 | 1.000 | | EF-particulate Matter | 8.067e-10 | 8.067e-10 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.1096 | 0.1117 | 0.981 | | Ecotoxicity, freshwater_organics | 0.002431 | 0.002097 | 1.159 | | Ecotoxicity, freshwater | 0.112 | 0.1137 | 0.985 | | Eutrophication marine | 2.441e-05 | 2.440e-05 | 1.000 | | Eutrophication, freshwater | 9.840e-06 | 9.840e-06 | 1.000 | | Eutrophication, terrestrial | 1.953e-04 | 2.021e-04 | 0.966 | | Human toxicity, cancer_inorganics | 8.741e-12 | 8.695e-12 | 1.005 | | Human toxicity, cancer_organics | 5.533e-12 | 5.532e-12 | 1.000 | | Human toxicity, cancer | 1.427e-11 | 1.423e-11 | 1.003 | | Human toxicity, non-cancer_inorganics | 4.457e-10 | 4.438e-10 | 1.004 | | Human toxicity, non-cancer_organics | 2.146e-11 | 2.144e-11 | 1.001 | | Human toxicity, non-cancer | 4.672e-10 | 4.652e-10 | 1.004 | | Ionising radiation, human health | 0.005555 | 0.005555 | 1.000 | | Land use | 5.682 | 5.656 | 1.005 | | Ozone depletion | 6.146e-10 | 6.146e-10 | 1.000 | | Photochemical ozone formation - human health | 6.082e-05 | 6.082e-05 | 1.000 | | Resource use, fossils | 0.268 | 0.268 | 1.000 | | Resource use, minerals and metals | 6.760e-07 | 6.655e-07 | 1.016 | | Water use | 0.01018 | 0.01013 | 1.005 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.02019 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 61.12 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | 570 kWp open ground installation, multi-Si, on open ground [RER] | 2.478e-08 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -11.0 / +13.4 | 13.7 (Resource use, minerals and metals) | | 570 kWp open ground installation, single-Si, on open ground [RER] | 1.313e-08 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -5.7 / +7.0 | 12.0 (Water use) | | 570 kWp open ground installation, CIS, on open ground [RER] | 7.745e-10 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.3 / +0.4 | 1.6 (Ozone depletion) | | 570 kWp open ground installation, CdTe, on open ground [RER] | 9.375e-10 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.3 / +0.3 | 0.5 (Land use) | | 570 kWp open ground installation, micro-Si, on open ground [RER] | 1.223e-10 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.1 / +0.1 | 0.1 (Climate change-Land use and land use change) | | 156 kWp flat-roof installation, multi-Si, on roof [CH] | 4.230e-12 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.0 / +0.0 | 0.0 (Human toxicity, non-cancer_organics) | | 93 kWp slanted-roof installation, multi-Si, panel, mounted, on roof [CH] | 7.884e-12 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.0 / +0.0 | 0.0 (Resource use, minerals and metals) | | Treatment, sewage, from residence, to wastewater treatment, class 2 [CH] | 2.219e-06 m3 | ×0.918 / ×1.09 | lognormal, GSD² 1.09 | -0.0 / +0.0 | 0.0 (Eutrophication marine) | | 3kWp flat roof installation, multi-Si, on roof [RER] | 1.100e-10 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.0 / +0.0 | 0.0 (Resource use, minerals and metals) | | Tap water, water balance according to MoeK 2013, at user [TR] | 0.002466 kg | ×0.918 / ×1.09 | lognormal, GSD² 1.09 | -0.0 / +0.0 | 0.1 (Water use) | | 156 kWp flat-roof installation, single-Si, on roof [CH] | 2.240e-12 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.0 / +0.0 | 0.0 (Water use) | | 93 kWp slanted-roof installation, single-Si, panel, mounted, on roof [CH] | 4.175e-12 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.0 / +0.0 | 0.0 (Water use) | | 3kWp slanted-roof installation, multi-Si, panel, mounted, on roof [RER] | 9.028e-11 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.0 / +0.0 | 0.0 (Resource use, minerals and metals) | | 3kWp flat roof installation, single-Si, on roof [RER] | 5.825e-11 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.0 / +0.0 | 0.0 (Resource use, minerals and metals) | | 3kWp slanted-roof installation, single-Si, panel, mounted, on roof [RER] | 4.781e-11 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.0 / +0.0 | 0.0 (Resource use, minerals and metals) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== ^ Source ^ Scope ^ Value ^ This dataset ^ Ratio ^ Note ^ | bafu | Electricity, production mix photovoltaic, at plant [IL] | 0.01673 kg CO2 eq | 0.02021 | 1.21 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [ZA] | 0.01723 kg CO2 eq | 0.02021 | 1.17 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [MX] | 0.01749 kg CO2 eq | 0.02021 | 1.16 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [CL] | 0.01751 kg CO2 eq | 0.02021 | 1.15 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [US] | 0.01921 kg CO2 eq | 0.02021 | 1.05 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [BE] | 0.0319 kg CO2 eq | 0.02021 | 0.63 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [FI] | 0.03271 kg CO2 eq | 0.02021 | 0.62 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [GB] | 0.0339 kg CO2 eq | 0.02021 | 0.60 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [NO] | 0.03502 kg CO2 eq | 0.02021 | 0.58 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [IE] | 0.0361 kg CO2 eq | 0.02021 | 0.56 | same dataset name, other location | ==== Conclusions and limitations ==== GWP100 0.02021 kg CO2 eq per kWh (95 % interval 0.01599–0.04329). Dominant contributors: 570 kWp open ground installation, multi-Si, on open ground 63 %; 570 kWp open ground installation, single-Si, on open ground 33 %; 570 kWp open ground installation, CIS, on open ground 2 %; 570 kWp open ground installation, CdTe, on open ground 2 %. Most sensitive: 570 kWp open ground installation, multi-Si, on open ground [RER] (-11.0 / +13.4 %); 570 kWp open ground installation, single-Si, on open ground [RER] (-5.7 / +7.0 %); 570 kWp open ground installation, CIS, on open ground [RER] (-0.3 / +0.4 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kWh | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 4.4e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 24/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 32/32 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.02021 in [0.01599, 0.04329] | | time period declared | **PASS** | 2005-01/2018-12 | | geography is a known location code | **PASS** | TR | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 1 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Frischknecht Rolf Stolz Philippe Krebs Luana de Wild-Scholten Mariska Sinha Parikhit (2020). Task 12 PV Sustainability - Life Cycle Inventories and Life Cycle Assessments of Photovoltaic Systems. Office of Scientific and Technical Information (OSTI). https://doi.org/10.2172/2308831 — //published source; matched in Crossref (author, year ±1, title overlap)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].