====== Transport, Bicycle, electric (<25 km/h), NMC battery, 2020 — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:transport_bicycle_electric_lt_25_km_h_nmc_battery_2020__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Transport, Bicycle, electric (<25 km/h), NMC battery, 2020 [CH], per 1 km. EF v3.1 climate change 0.01106 kg CO2 eq (Monte Carlo 95 % interval 0.0105–0.01373). Main contributors: Bicycle, electric (<25 km/h), NMC battery, 2020 78 %; Maintenance, electric bicycle, without battery 9 %; Electricity, low voltage, at grid 7 %; Road 5 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Transport, Bicycle, electric (<25 km/h), NMC battery, 2020 | | Dataset UUID / graph id | ''%%4d677321-4458-3bf2-9dae-0e7bb942ba51%%'' / ''%%activity:transport_bicycle_electric_lt_25_km_h_nmc_battery_2020__ch%%'' | | Reference product, unit | Transport, Bicycle, electric (<25 km/h), NMC battery, 2020, 1 km | | Location | CH | | Time period | 2020-01/2020-12 | | Category | transport systems / road\Transformation | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Power: 0.25 kW. Lifetime: 20000 km. Annual kilometers: 2000 km. Number of passengers: 1. Curb mass: 23.1 kg. Lightweighting of glider: 0%. Emission standard: None. Service visits throughout lifetime: 1.3. Range: 58 km. Battery capacity: 0.5 kWh. Available battery capacity: 0.4 kWh. Battery mass: 3.1 kg. Battery replacement throughout lifetime: 1. Fuel tank capacity: 0 kWh. Fuel mass: 0 kg. Source: Sacchi R., Bauer C. Life cycle inventories for on-road vehicles. Paul Scherrer Institut, 2023. DOI: 10.5281/zenodo.5156043. UUID: 4d677321-4458-3bf2-9dae-0e7bb942ba51 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 km** of Transport, Bicycle, electric (<25 km/h), NMC battery, 2020 (CH). All results are given per unit of the reference flow. ==== System boundary ==== — ==== Technology ==== Power: 0.25 kW. Lifetime: 20000 km. Annual kilometers: 2000 km. Number of passengers: 1. Curb mass: 23.1 kg. Lightweighting of glider: 0%. Emission standard: None. Service visits throughout lifetime: 1.3. Range: 58 km. Battery capacity: 0.5 kWh. Available battery capacity: 0.4 kWh. Battery mass: 3.1 kg. Battery replacement throughout lifetime: 1. Fuel tank capacity: 0 kWh. Fuel mass: 0 kg. Source: Sacchi R., Bauer C. Life cycle inventories for on-road vehicles. Paul Scherrer Institut, 2023. DOI: 10.5281/zenodo.5156043 ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Bicycle, electric (<25 km/h), NMC battery, 2020 | technosphere | CH | 5.0000e-05 | p | lognormal, GSD² 1.13 | (3,3,2,1,1,3) | 78.5 | ████████████████ | | | Maintenance, electric bicycle, without battery | technosphere | CH | 6.6700e-05 | p | lognormal, GSD² 1.13 | (3,3,2,1,1,3) | 9.5 | ██ | | | Electricity, low voltage, at grid | technosphere | CH | 0.00754 | kWh | lognormal, GSD² 1.24 | (4,4,2,2,1,3) | 6.6 | █ | | | Road | technosphere | CH | 5.3300e-05 | my | lognormal, GSD² 1.52 | (3,1,5,2,1,1) | 5.4 | █ | | | Disposal, road | technosphere | RER | 7.6000e-05 | my | lognormal, GSD² 1.52 | (3,1,5,2,1,1) | 0.1 | · | | | Road wear emissions, passenger car | technosphere | RER | 4.1900e-06 | kg | lognormal, GSD² 1.62 | (4,5,2,3,4,3) | 0.0 | · | | | Tyre wear emissions, passenger car | technosphere | RER | 4.1300e-06 | kg | lognormal, GSD² 1.62 | (4,5,2,3,4,3) | 0.0 | · | | | Brake wear emissions, passenger car | technosphere | RER | 3.8400e-06 | kg | lognormal, GSD² 1.62 | (4,5,2,3,4,3) | 0.0 | · | | ==== Data quality ==== 8 of 8 direct exchanges carry a declared pedigree, 8 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.5 · completeness 3.38 · temporal 2.75 · geographical 2.12 · technological 2.12 · sample size 2.5. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Romain Sacchi (PSI); data entry: Julien McTighe (INFRAS); validation (proof reading): Brian Cox (INFRAS) | | time period comment | Technology and vehicle lightweighting factors match manufacture year of 2020 | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 km. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **1.500e-04** | 1.128e-04 | 2.374e-04 | 1.46 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **4.738e-05** | 3.580e-05 | 9.290e-05 | 1.62 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.011** | 0.01045 | 0.01366 | 1.15 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **9.204e-06** | 7.646e-06 | 1.327e-05 | 1.32 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.01106** | 0.0105 | 0.01373 | 1.15 | | EF-particulate Matter | Impact on human health | disease incidence | **1.420e-09** | 1.250e-09 | 1.918e-09 | 1.24 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.0845** | 0.07549 | 0.1421 | 1.4 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.001873** | 0.001756 | 0.003123 | 1.42 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.08638** | 0.07766 | 0.1444 | 1.39 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **2.148e-05** | 1.787e-05 | 3.239e-05 | 1.35 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **1.792e-05** | 1.185e-05 | 1.077e-04 | 3.15 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **1.279e-04** | 1.140e-04 | 1.776e-04 | 1.26 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.035e-11** | 8.812e-12 | 2.915e-11 | 1.85 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.662e-12** | 3.239e-12 | 5.545e-12 | 1.32 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.401e-11** | 1.280e-11 | 3.355e-11 | 1.65 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **8.128e-10** | 6.171e-10 | 2.442e-09 | 2 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.174e-11** | 3.539e-11 | 9.546e-11 | 1.67 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **8.646e-10** | 6.685e-10 | 2.493e-09 | 1.94 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.008341** | 0.003031 | 0.04765 | 4.24 | | Land use | Soil quality index | pt (soil quality index) | **0.06274** | 0.05945 | 0.09539 | 1.28 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **3.928e-10** | 3.621e-10 | 5.525e-10 | 1.24 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **5.360e-05** | 4.895e-05 | 7.336e-05 | 1.24 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.2079** | 0.1927 | 0.2789 | 1.2 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **3.665e-07** | 3.198e-07 | 4.942e-07 | 1.25 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.005795** | -5.317 | 2.602 | — | Climate change 0.01106 kg CO2 eq per km. Main contributors: Bicycle, electric (<25 km/h), NMC battery, 2020 78 %; Maintenance, electric bicycle, without battery 9 %; Electricity, low voltage, at grid 7 %; Road 5 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Bicycle, electric (<25 km/h), NMC battery, 2020 78 %; Maintenance, electric bicycle, without battery 9 %; Electricity, low voltage, at grid 7 %; Road 5 %. Most sensitive exchanges (Section 6.3): Bicycle, electric (<25 km/h), NMC battery, 2020 [CH] (-8.8 / +9.9 %); Road [CH] (-1.8 / +2.7 %); Electricity, low voltage, at grid [CH] (-1.2 / +1.5 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per m, converted ×1000 to per km: ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 1.500e-04 | 1.570e-04 | 0.955 | | Climate change-Biogenic | 4.738e-05 | 4.738e-05 | 1.000 | | Climate change-Fossil | 0.011 | 0.011 | 1.000 | | Climate change-Land use and land use change | 9.204e-06 | 9.204e-06 | 1.000 | | Climate change | 0.01106 | 0.01106 | 1.000 | | EF-particulate Matter | 1.420e-09 | 1.420e-09 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.0845 | 0.08805 | 0.960 | | Ecotoxicity, freshwater_organics | 0.001873 | 0.001677 | 1.117 | | Ecotoxicity, freshwater | 0.08638 | 0.08968 | 0.963 | | Eutrophication marine | 2.148e-05 | 2.147e-05 | 1.000 | | Eutrophication, freshwater | 1.792e-05 | 1.792e-05 | 1.000 | | Eutrophication, terrestrial | 1.279e-04 | 1.338e-04 | 0.956 | | Human toxicity, cancer_inorganics | 1.035e-11 | 1.030e-11 | 1.005 | | Human toxicity, cancer_organics | 3.662e-12 | 3.662e-12 | 1.000 | | Human toxicity, cancer | 1.401e-11 | 1.396e-11 | 1.003 | | Human toxicity, non-cancer_inorganics | 8.128e-10 | 8.104e-10 | 1.003 | | Human toxicity, non-cancer_organics | 5.174e-11 | 5.172e-11 | 1.000 | | Human toxicity, non-cancer | 8.646e-10 | 8.622e-10 | 1.003 | | Ionising radiation, human health | 0.008341 | 0.008341 | 1.000 | | Land use | 0.06274 | 0.05134 | 1.222 | | Ozone depletion | 3.928e-10 | 3.928e-10 | 1.000 | | Photochemical ozone formation - human health | 5.360e-05 | 5.360e-05 | 1.000 | | Resource use, fossils | 0.2079 | 0.208 | 1.000 | | Resource use, minerals and metals | 3.665e-07 | 3.618e-07 | 1.013 | | Water use | 0.005795 | 0.005971 | 0.971 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.01105 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 31.97 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Bicycle, electric (<25 km/h), NMC battery, 2020 [CH] | 5.000e-05 p | ×0.888 / ×1.13 | lognormal, GSD² 1.13 | -8.8 / +9.9 | 12.1 (Acidification) | | Road [CH] | 5.330e-05 my | ×0.665 / ×1.5 | lognormal, GSD² 1.52 | -1.8 / +2.7 | 5.4 (Photochemical ozone formation - human health) | | Electricity, low voltage, at grid [CH] | 0.00754 kWh | ×0.811 / ×1.23 | lognormal, GSD² 1.24 | -1.2 / +1.5 | 15.1 (Ionising radiation, human health) | | Maintenance, electric bicycle, without battery [CH] | 6.670e-05 p | ×0.888 / ×1.13 | lognormal, GSD² 1.13 | -1.1 / +1.2 | 1.6 (Ozone depletion) | | Disposal, road [RER] | 7.600e-05 my | ×0.665 / ×1.5 | lognormal, GSD² 1.52 | -0.0 / +0.0 | 0.1 (Eutrophication, terrestrial) | | Road wear emissions, passenger car [RER] | 4.190e-06 kg | ×0.622 / ×1.61 | lognormal, GSD² 1.62 | -0.0 / +0.0 | 13.8 (EF-particulate Matter) | | Tyre wear emissions, passenger car [RER] | 4.130e-06 kg | ×0.622 / ×1.61 | lognormal, GSD² 1.62 | -0.0 / +0.0 | 2.3 (EF-particulate Matter) | | Brake wear emissions, passenger car [RER] | 3.840e-06 kg | ×0.622 / ×1.61 | lognormal, GSD² 1.62 | -0.0 / +0.0 | 20.6 (EF-particulate Matter) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.01106 kg CO2 eq per km (95 % interval 0.0105–0.01373). Dominant contributors: Bicycle, electric (<25 km/h), NMC battery, 2020 78 %; Maintenance, electric bicycle, without battery 9 %; Electricity, low voltage, at grid 7 %; Road 5 %. Most sensitive: Bicycle, electric (<25 km/h), NMC battery, 2020 [CH] (-8.8 / +9.9 %); Road [CH] (-1.8 / +2.7 %); Electricity, low voltage, at grid [CH] (-1.2 / +1.5 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 km | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.6e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per m, converted ×1000 to per km (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 23/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 8/8 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.01106 in [0.0105, 0.01373] | | time period declared | **PASS** | 2020-01/2020-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 1 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Sacchi R., Bauer C. (2021). Life cycle inventories for on-road vehicles. Zenodo. https://doi.org/10.5281/ZENODO.5156043 — //published source; DOI resolved at doi.org// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].