====== Photovoltaic panel, CIS, Sto, Ventec Artline inlay, at plant — DE ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:photovoltaic_panel_cis_sto_ventec_artline_inlay_at_plant__de|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Photovoltaic panel, CIS, Sto, Ventec Artline inlay, at plant [DE], per 1 m2. EF v3.1 climate change 83.24 kg CO2 eq (Monte Carlo 95 % interval 78.12–107). Main contributors: Electricity, medium voltage, at grid 23 %; Aluminium alloy, AlMg3, at plant 19 %; Solar glass, low-iron, at regional storage 13 %; Polyvinylbutyral foil, at plant 13 %; Flat glass, uncoated, at plant 9 %; Disposal, plastics, mixture, 15.3% water, to municipal incin… 5 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Photovoltaic panel, CIS, Sto, Ventec Artline inlay, at plant | | Dataset UUID / graph id | ''%%4dd27ae2-da99-325c-b25d-2ab3c95ece1a%%'' / ''%%activity:photovoltaic_panel_cis_sto_ventec_artline_inlay_at_plant__de%%'' | | Reference product, unit | Photovoltaic panel, CIS, Sto, Ventec Artline inlay, at plant, 1 m2 | | Location | DE | | Time period | 2018-01/2020-12 | | Category | photovoltaic / production of components | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Production of photovoltaic thin film modules by thermal vaporization in vacuum. The modules produced at NICE Solar Energy have a size of 0.72m2. The weight is 20.5kg/m2. The specific maximum power is 95 Wp/m2. with aluminium frame; Synonyms: Solarmodul, PV-module, copper indium selenide, thin film, CIGS; UUID: 4dd27ae2-da99-325c-b25d-2ab3c95ece1a This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 m2** of Photovoltaic panel, CIS, Sto, Ventec Artline inlay, at plant (DE). All results are given per unit of the reference flow. ==== System boundary ==== Electricity use, materials, transport of materials, treatment of production wastes. Disposal after end of life. ==== Technology ==== — ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electricity, medium voltage, at grid | technosphere | DE | 44.7 | kWh | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 23.1 | █████ | | | Aluminium alloy, AlMg3, at plant | technosphere | RER | 2.2 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 18.6 | ████ | | | Solar glass, low-iron, at regional storage | technosphere | RER | 10 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 13.3 | ███ | | | Polyvinylbutyral foil, at plant | technosphere | RER | 1.025 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 12.9 | ███ | | | Flat glass, uncoated, at plant | technosphere | RER | 7.5 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 9.0 | ██ | | | Disposal, plastics, mixture, 15.3% water, to municipal incineration | technosphere | CH | 1.8126 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 5.2 | █ | | | Nitrogen, liquid, at plant | technosphere | RER | 15.7 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 4.2 | █ | | | Tempering, flat glass | technosphere | RER | 10 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 3.0 | █ | | | Light fuel oil, burned in industrial furnace 1MW, non-modulating | technosphere | RER | 15.5 | MJ | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 1.8 | · | | | Silicone product, at plant | technosphere | RER | 0.404 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 1.4 | · | | | Polyethylene terephthalate, granulate, amorphous, at plant | technosphere | RER | 0.336 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 1.1 | · | | | Photovoltaic panel factory | technosphere | GLO | 4.0000e-06 | p | lognormal, GSD² 3.02 | (1,4,1,3,1,3) | 1.1 | · | | | Transport, freight, lorry, fleet average | technosphere | RER | 3.8351 | tkm | lognormal, GSD² 2.1 | — | 0.9 | · | | | Butyl acrylate, at plant | technosphere | RER | 0.101 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.5 | · | | | Polyphenylene sulfide, at plant | technosphere | GLO | 0.0859 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.5 | · | | | Transport, freight, rail | technosphere | RER | 22.846 | tkm | lognormal, GSD² 2.1 | — | 0.5 | · | | | Indium, at regional storage | technosphere | RER | 0.00282 | kg | lognormal, GSD² 1.13 | (3,2,2,1,1,3) | 0.5 | · | | | Glass fibre reinforced plastic, polyamide, injection moulding, at plant | technosphere | RER | 0.04 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.4 | · | | | Diode, unspecified, at plant | technosphere | GLO | 0.00144 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.3 | · | | | EUR-flat pallet | technosphere | RER | 0.05 | p | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.3 | · | | | Aluminium, production mix, at plant | technosphere | RER | 0.0444 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.3 | · | | | Ammonia, liquid, at regional storehouse | technosphere | RER | 0.0929 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.3 | · | | | Gallium, semiconductor-grade, at regional storage | technosphere | RER | 8.9900e-04 | kg | lognormal, GSD² 1.13 | (3,2,2,1,1,3) | 0.2 | · | | | Tin, at regional storage | technosphere | RER | 0.0123 | kg | lognormal, GSD² 1.13 | (3,2,2,1,1,3) | 0.2 | · | | | Polyethylene, HDPE, granulate, at plant | technosphere | RER | 0.0484 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.1 | · | | | Disposal, glass, 0% water, to municipal incineration | technosphere | CH | 4.6415 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.1 | · | | | Hydrochloric acid, 30% in H2O, at plant | technosphere | RER | 0.0994 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.1 | · | | | Hydrogen sulphide, H2S, at plant | technosphere | RER | 0.191 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.1 | · | | | Molybdenum, at regional storage | technosphere | RER | 0.00606 | kg | lognormal, GSD² 1.13 | (3,2,2,1,1,3) | 0.0 | · | | | Treatment, sewage, unpolluted, to wastewater treatment, class 3 | technosphere | CH | 0.131 | m3 | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.0 | · | | | Zinc oxide, at plant | technosphere | RER | 0.00909 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.0 | · | | | Tap water, at user | technosphere | RER | 131 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.0 | · | | | Flux, wave soldering, at plant | technosphere | GLO | 0.0123 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.0 | · | | | Hydrogen peroxide, 50% in H2O, at plant | technosphere | RER | 0.0231 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.0 | · | | | Sodium hydroxide, 50% in H2O, production mix, at plant | technosphere | RER | 0.0334 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.0 | · | | | Copper, at regional storage | technosphere | RER | 0.00977 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.0 | · | | | Selenium, at plant | technosphere | RER | 0.0056 | kg | lognormal, GSD² 1.13 | (3,2,2,1,1,3) | 0.0 | · | | | Disposal, waste, Si waferprod., inorg, 9.4% water, to residual material landfill | technosphere | CH | 0.0202 | kg | lognormal, GSD² 1.24 | (3,1,1,1,3,3) | 0.0 | · | | | Sulphuric acid, liquid, at plant | technosphere | RER | 0.0331 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.0 | · | | | Urea, as N, at regional storehouse | technosphere | RER | 0.00115 | kg | lognormal, GSD² 1.16 | (3,1,3,1,1,3) | 0.0 | · | | | Wire drawing, copper | technosphere | RER | 0.00977 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.0 | · | | | Argon, liquid, at plant | technosphere | RER | 0.019 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.0 | · | | | Disposal, inert waste, 5% water, to construction waste landfill | technosphere | CH | 0.65 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.0 | · | | | Diborane, at plant | technosphere | GLO | 2.0100e-04 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.0 | · | | | Cadmium sulphide, semiconductor-grade, at plant | technosphere | US | 2.6900e-04 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.0 | · | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 160.92 | MJ | lognormal, GSD² 1.07 | (1,1,1,1,1,3) | 0.0 | · | | | Cadmium | elementary | air/Ground level / Urban (>1000 people/s… | 2.1000e-08 | kg | lognormal, GSD² 5.09 | (3,4,3,3,1,5) | 0.0 | · | | ==== Data quality ==== 45 of 47 direct exchanges carry a declared pedigree, 47 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 1.36 · completeness 1.24 · temporal 1.2 · geographical 1.09 · technological 1.04 · sample size 3.04. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Luana Krebs (TREEZE); data entry: Luana Krebs (TREEZE); validation (proof reading): Luana Krebs (TREEZE) | | extrapolations | | | sampling procedure | Based on literature data and producer information | | production volume | na | | uncertainty adjustments | | | time period comment | Time of publication. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 m2. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **0.3694** | 0.303 | 0.5913 | 1.39 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.4846** | 0.3545 | 0.8837 | 1.57 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **82.72** | 77.65 | 106.3 | 1.17 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.03722** | 0.03054 | 0.05464 | 1.34 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **83.24** | 78.12 | 107 | 1.17 | | EF-particulate Matter | Impact on human health | disease incidence | **3.900e-06** | 2.940e-06 | 4.064e-05 | 3.79 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **393.9** | 347.4 | 625.3 | 1.35 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **63.06** | 51.71 | 89.99 | 1.34 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **456.9** | 418 | 687.3 | 1.31 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **0.07752** | 0.06701 | 0.1173 | 1.33 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **0.03717** | 0.02172 | 0.1282 | 2.5 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **0.7801** | 0.6577 | 1.25 | 1.39 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.675e-08** | 1.504e-08 | 5.084e-08 | 1.91 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.462e-08** | 2.867e-08 | 5.160e-08 | 1.35 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **5.137e-08** | 4.860e-08 | 9.157e-08 | 1.42 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.423e-07** | 7.991e-07 | 1.936e-06 | 1.56 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.258e-08** | 4.725e-08 | 8.341e-08 | 1.34 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **7.949e-07** | 8.530e-07 | 2.006e-06 | 1.53 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **19.45** | 6.893 | 118.2 | 4.31 | | Land use | Soil quality index | pt (soil quality index) | **555.8** | 509.2 | 873.7 | 1.31 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **7.040e-05** | 4.138e-05 | 1.227e-04 | 1.77 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **0.2533** | 0.2281 | 0.3819 | 1.31 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **1072** | 1008 | 1488 | 1.22 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **8.067e-04** | 4.234e-04 | 0.001623 | 1.99 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **8.322** | -1.341e+04 | 6798 | — | Climate change 83.24 kg CO2 eq per m2. Main contributors: Electricity, medium voltage, at grid 23 %; Aluminium alloy, AlMg3, at plant 19 %; Solar glass, low-iron, at regional storage 13 %; Polyvinylbutyral foil, at plant 13 %; Flat glass, uncoated, at plant 9 %; Disposal, plastics, mixture, 15.3% water, to municipal incin… 5 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electricity, medium voltage, at grid 23 %; Aluminium alloy, AlMg3, at plant 19 %; Solar glass, low-iron, at regional storage 13 %; Polyvinylbutyral foil, at plant 13 %; Flat glass, uncoated, at plant 9 %; Disposal, plastics, mixture, 15.3% water, to municipal incin… 5 %. Most sensitive exchanges (Section 6.3): Electricity, medium voltage, at grid [DE] (-1.5 / +1.6 %); Photovoltaic panel factory [GLO] (-0.7 / +2.2 %); Aluminium alloy, AlMg3, at plant [RER] (-1.2 / +1.3 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 0.3694 | 0.3834 | 0.963 | | Climate change-Biogenic | 0.4846 | 0.4846 | 1.000 | | Climate change-Fossil | 82.72 | 82.72 | 1.000 | | Climate change-Land use and land use change | 0.03722 | 0.03722 | 1.000 | | Climate change | 83.24 | 83.24 | 1.000 | | EF-particulate Matter | 3.900e-06 | 3.900e-06 | 1.000 | | Ecotoxicity, freshwater_inorganics | 393.9 | 397.4 | 0.991 | | Ecotoxicity, freshwater_organics | 63.06 | 36.03 | 1.750 | | Ecotoxicity, freshwater | 456.9 | 433.4 | 1.054 | | Eutrophication marine | 0.07752 | 0.07751 | 1.000 | | Eutrophication, freshwater | 0.03717 | 0.03717 | 1.000 | | Eutrophication, terrestrial | 0.7801 | 0.8164 | 0.956 | | Human toxicity, cancer_inorganics | 1.675e-08 | 1.634e-08 | 1.026 | | Human toxicity, cancer_organics | 3.462e-08 | 3.461e-08 | 1.000 | | Human toxicity, cancer | 5.137e-08 | 5.095e-08 | 1.008 | | Human toxicity, non-cancer_inorganics | 7.423e-07 | 7.273e-07 | 1.021 | | Human toxicity, non-cancer_organics | 5.258e-08 | 5.135e-08 | 1.024 | | Human toxicity, non-cancer | 7.949e-07 | 7.787e-07 | 1.021 | | Ionising radiation, human health | 19.45 | 19.45 | 1.000 | | Land use | 555.8 | 474.2 | 1.172 | | Ozone depletion | 7.040e-05 | 7.040e-05 | 1.000 | | Photochemical ozone formation - human health | 0.2533 | 0.2533 | 1.000 | | Resource use, fossils | 1072 | 1072 | 1.000 | | Resource use, minerals and metals | 8.067e-04 | 7.280e-04 | 1.108 | | Water use | 8.322 | 9.659 | 0.862 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 83.05 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 1.554e+05 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Electricity, medium voltage, at grid [DE] | 44.7 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -1.5 / +1.6 | 4.0 (Eutrophication, freshwater) | | Photovoltaic panel factory [GLO] | 4.000e-06 p | ×0.339 / ×2.95 | lognormal, GSD² 3.02 | -0.7 / +2.2 | 24.1 (Land use) | | Aluminium alloy, AlMg3, at plant [RER] | 2.2 kg | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -1.2 / +1.3 | 3.7 (Human toxicity, cancer_inorganics) | | Solar glass, low-iron, at regional storage [RER] | 10 kg | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.9 / +0.9 | 2.1 (Eutrophication, terrestrial) | | Polyvinylbutyral foil, at plant [RER] | 1.025 kg | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.8 / +0.9 | 6.8 (Ozone depletion) | | Transport, freight, lorry, fleet average [RER] | 3.835 tkm | ×0.484 / ×2.06 | lognormal, GSD² 2.1 | -0.4 / +0.9 | 8.0 (Climate change-Land use and land use change) | | Flat glass, uncoated, at plant [RER] | 7.5 kg | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.6 / +0.6 | 1.3 (Acidification) | | Transport, freight, rail [RER] | 22.85 tkm | ×0.484 / ×2.06 | lognormal, GSD² 2.1 | -0.2 / +0.5 | 2.7 (Human toxicity, non-cancer_organics) | | Disposal, plastics, mixture, 15.3% water, to municipal incineration [CH] | 1.813 kg | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.3 / +0.4 | 0.4 (Climate change-Fossil) | | Nitrogen, liquid, at plant [RER] | 15.7 kg | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.3 / +0.3 | 1.7 (Ionising radiation, human health) | | Tempering, flat glass [RER] | 10 kg | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.2 / +0.2 | 0.3 (Eutrophication, terrestrial) | | Light fuel oil, burned in industrial furnace 1MW, non-modulating [RER] | 15.5 MJ | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.1 / +0.1 | 0.1 (Climate change-Fossil) | | Silicone product, at plant [RER] | 0.404 kg | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.1 / +0.1 | 0.3 (Climate change-Biogenic) | | Polyethylene terephthalate, granulate, amorphous, at plant [RER] | 0.336 kg | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.1 / +0.1 | 0.1 (Resource use, fossils) | | Indium, at regional storage [RER] | 0.00282 kg | ×0.887 / ×1.13 | lognormal, GSD² 1.13 | -0.1 / +0.1 | 2.0 (Human toxicity, non-cancer_inorganics) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 83.24 kg CO2 eq per m2 (95 % interval 78.12–107). Dominant contributors: Electricity, medium voltage, at grid 23 %; Aluminium alloy, AlMg3, at plant 19 %; Solar glass, low-iron, at regional storage 13 %; Polyvinylbutyral foil, at plant 13 %; Flat glass, uncoated, at plant 9 %; Disposal, plastics, mixture, 15.3% water, to municipal incin… 5 %. Most sensitive: Electricity, medium voltage, at grid [DE] (-1.5 / +1.6 %); Photovoltaic panel factory [GLO] (-0.7 / +2.2 %); Aluminium alloy, AlMg3, at plant [RER] (-1.2 / +1.3 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 m2 | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 7.2e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 20/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 47/47 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 83.24 in [78.12, 107] | | time period declared | **PASS** | 2018-01/2020-12 | | geography is a known location code | **PASS** | DE | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Frischknecht R.,, Stolz P., Sinha P., de Wild-Scholten M. (2020) Life Cycle Inventories and Life Cycle Assessments of Photovoltaic Systems. Project report. Volume: 174. IEA PVPS Task 12. Type: Separate publication Source: Report First author: Frischknecht R., Other authors: Stolz P., Sinha P., de Wild-Scholten M. Year: 2020 Title of anthology: Project report Publisher: IEA PVPS Task 12 Volume No: … — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].