====== Tap water, water balance according to MoeK 2013, at user — ES ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:tap_water_water_balance_according_to_moek_2013_at_user__es|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Tap water, water balance according to MoeK 2013, at user [ES], per 1 kg. EF v3.1 climate change 1.751e-04 kg CO2 eq (Monte Carlo 95 % interval 1.396e-04–3.102e-04). Main contributors: Electricity, medium voltage, at grid 46 %; Water works 23 %; Water supply network 10 %; Ozone, liquid, at plant 8 %; Water storage 3 %; Charcoal, at plant 3 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Tap water, water balance according to MoeK 2013, at user | | Dataset UUID / graph id | ''%%4ef90574-4897-301c-b508-c06971a48763%%'' / ''%%activity:tap_water_water_balance_according_to_moek_2013_at_user__es%%'' | | Reference product, unit | Tap water, water balance according to MoeK 2013, at user, 1 kg | | Location | ES | | Time period | 2000-01/2017-12 | | Category | water / water supply\production | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== This process is based on the dataset "tap water, at user/kg/RER U" from Ecoinvent v2.2. The electricity consumption is regionalised. The water withdrawal and water emissions to water are regionalised. The water embodied in product (1 kg/kg) is not included and has to be accounted for in the processes, which use tap water.; CAS number: 007732-18-5; Formula: H2O; UUID: 4ef90574-4897-301c-b508-c06971a48763 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kg** of Tap water, water balance according to MoeK 2013, at user (ES). All results are given per unit of the reference flow. ==== System boundary ==== Infrastructure and energy use for water treatment and transportation to the end user. No emissions from water treatment. ==== Technology ==== Example of a water works in CH. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electricity, medium voltage, at grid | technosphere | ES | 3.9000e-04 | kWh | lognormal, GSD² 1.22 | — | 46.0 | █████████ | | | Water works | technosphere | CH | 1.1907e-11 | p | lognormal, GSD² 3.05 | — | 23.4 | █████ | | | Water supply network | technosphere | CH | 3.1429e-10 | km | lognormal, GSD² 3.05 | — | 9.6 | ██ | | | Ozone, liquid, at plant | technosphere | RER | 3.3333e-06 | kg | lognormal, GSD² 1.22 | — | 7.9 | ██ | | | Water storage | technosphere | CH | 2.0568e-11 | p | lognormal, GSD² 3.05 | — | 3.4 | █ | | | Charcoal, at plant | technosphere | GLO | 4.1700e-06 | kg | lognormal, GSD² 1.22 | — | 2.9 | █ | | | Treatment, sewage, unpolluted, to wastewater treatment, class 3 | technosphere | CH | 1.7656e-05 | m3 | lognormal, GSD² 1.22 | — | 2.8 | █ | | | Pump station | technosphere | CH | 2.0568e-11 | p | lognormal, GSD² 3.05 | — | 1.7 | · | | | Aluminium sulphate, powder, at plant | technosphere | RER | 6.3300e-06 | kg | lognormal, GSD² 1.22 | — | 1.3 | · | | | Hydrogen peroxide, 50% in H2O, at plant | technosphere | RER | 8.8000e-07 | kg | lognormal, GSD² 1.22 | — | 0.5 | · | | | Transport, freight, lorry, fleet average | technosphere | CH | 1.4813e-06 | tkm | lognormal, GSD² 2.1 | — | 0.1 | · | | | Transport, freight, rail | technosphere | RER | 8.8880e-06 | tkm | lognormal, GSD² 2.1 | — | 0.1 | · | | | Disposal, wood untreated, 20% water, to municipal incineration | technosphere | CH | 4.1700e-06 | kg | lognormal, GSD² 1.22 | — | 0.0 | · | | | Chlorine, liquid, production mix, at plant | technosphere | RER | 1.0000e-07 | kg | lognormal, GSD² 1.22 | — | 0.0 | · | | | Aluminium | elementary | water/River | 1.2948e-06 | kg | lognormal, GSD² 5.26 | — | 0.0 | · | | | Water, ES | elementary | natural resource [ES] | 0.0011287 | m3 | lognormal, GSD² 1.07 | — | 0.0 | · | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 0.001404 | MJ | lognormal, GSD² 1.22 | — | 0.0 | · | | | Water, ES | elementary | water/Unknown [ES] | 1.1100e-04 | m3 | lognormal, GSD² 1.62 | — | 0.0 | · | | | Chloride(1-) | elementary | water/River | 5.0352e-06 | kg | lognormal, GSD² 3.23 | — | 0.0 | · | | | Chlorine | elementary | water/River | 1.0000e-07 | kg | lognormal, GSD² 3.23 | — | 0.0 | · | | ==== Data quality ==== 0 of 20 direct exchanges carry a declared pedigree, 20 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Philippe Stolz (TREEZE); data entry: Philippe Stolz (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | | | sampling procedure | | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: 29.03.2019; Other validation: \SRV01\ESU-Docs\Projekte laufend\174 Photovoltaic, IEA Task 12\2017 National PV Mixes\EcoSpold[603-Tap-Water-aus-Proj603-v0.7.xlsx]X-Process; | | time period comment | Time of publications. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kg. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **2.537e-07** | 2.221e-07 | 4.735e-07 | 1.49 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **5.094e-06** | 3.347e-06 | 7.822e-06 | 1.53 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.698e-04** | 1.338e-04 | 3.053e-04 | 1.53 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.730e-07** | 1.173e-07 | 3.070e-07 | 1.66 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.751e-04** | 1.396e-04 | 3.102e-04 | 1.51 | | EF-particulate Matter | Impact on human health | disease incidence | **7.654e-12** | 5.822e-12 | 1.834e-11 | 1.78 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.008781** | 0.004335 | 0.032 | 2.83 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.208e-05** | 8.898e-06 | 4.111e-05 | 2.26 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.008793** | 0.004349 | 0.03202 | 2.83 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **1.167e-07** | 9.612e-08 | 2.254e-07 | 1.55 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **4.112e-08** | 2.909e-08 | 1.832e-07 | 2.58 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **1.058e-06** | 8.710e-07 | 2.097e-06 | 1.57 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **4.625e-14** | 3.616e-14 | 1.775e-13 | 2.24 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.578e-13** | 1.062e-13 | 2.825e-13 | 1.65 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.041e-13** | 1.564e-13 | 3.985e-13 | 1.61 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.492e-12** | 2.086e-12 | 1.681e-11 | 2.93 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **9.514e-14** | 7.889e-14 | 2.043e-13 | 1.65 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **3.587e-12** | 2.186e-12 | 1.695e-11 | 2.87 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **1.893e-04** | 6.927e-05 | 0.001097 | 4.03 | | Land use | Soil quality index | pt (soil quality index) | **0.008141** | 0.005922 | 0.01641 | 1.69 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **3.452e-12** | 2.687e-12 | 8.529e-12 | 1.78 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **4.863e-07** | 3.971e-07 | 1.101e-06 | 1.66 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.003304** | 0.002536 | 0.007652 | 1.73 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **3.901e-10** | 2.638e-10 | 9.433e-10 | 2.16 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.0791** | 0.01811 | 0.1113 | — | Climate change 1.751e-04 kg CO2 eq per kg. Main contributors: Electricity, medium voltage, at grid 46 %; Water works 23 %; Water supply network 10 %; Ozone, liquid, at plant 8 %; Water storage 3 %; Charcoal, at plant 3 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electricity, medium voltage, at grid 46 %; Water works 23 %; Water supply network 10 %; Ozone, liquid, at plant 8 %; Water storage 3 %; Charcoal, at plant 3 %. Most sensitive exchanges (Section 6.3): Water works [CH] (-15.6 / +46.5 %); Water supply network [CH] (-6.4 / +19.1 %); Electricity, medium voltage, at grid [ES] (-8.3 / +10.1 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 2.537e-07 | 4.391e-07 | 0.578 | | Climate change-Biogenic | 5.094e-06 | 5.094e-06 | 1.000 | | Climate change-Fossil | 1.698e-04 | 1.698e-04 | 1.000 | | Climate change-Land use and land use change | 1.730e-07 | 1.730e-07 | 1.000 | | Climate change | 1.751e-04 | 1.751e-04 | 1.000 | | EF-particulate Matter | 7.654e-12 | 7.654e-12 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.008781 | 0.00879 | 0.999 | | Ecotoxicity, freshwater_organics | 1.208e-05 | 1.190e-05 | 1.016 | | Ecotoxicity, freshwater | 0.008793 | 0.008802 | 0.999 | | Eutrophication marine | 1.167e-07 | 1.166e-07 | 1.000 | | Eutrophication, freshwater | 4.112e-08 | 4.112e-08 | 1.000 | | Eutrophication, terrestrial | 1.058e-06 | 1.279e-06 | 0.827 | | Human toxicity, cancer_inorganics | 4.625e-14 | 4.562e-14 | 1.014 | | Human toxicity, cancer_organics | 1.578e-13 | 1.578e-13 | 1.000 | | Human toxicity, cancer | 2.041e-13 | 2.034e-13 | 1.003 | | Human toxicity, non-cancer_inorganics | 3.492e-12 | 3.466e-12 | 1.007 | | Human toxicity, non-cancer_organics | 9.514e-14 | 9.513e-14 | 1.000 | | Human toxicity, non-cancer | 3.587e-12 | 3.562e-12 | 1.007 | | Ionising radiation, human health | 1.893e-04 | 1.893e-04 | 1.000 | | Land use | 0.008141 | 0.00489 | 1.665 | | Ozone depletion | 3.452e-12 | 3.452e-12 | 1.000 | | Photochemical ozone formation - human health | 4.863e-07 | 4.863e-07 | 1.000 | | Resource use, fossils | 0.003304 | 0.003305 | 1.000 | | Resource use, minerals and metals | 3.901e-10 | 3.715e-10 | 1.050 | | Water use | 0.0791 | 0.0791 | 1.000 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 1.750e-04 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 0.3841 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Water works [CH] | 1.191e-11 p | ×0.335 / ×2.99 | lognormal, GSD² 3.05 | -15.6 / +46.5 | 77.0 (EF-particulate Matter) | | Water supply network [CH] | 3.143e-10 km | ×0.335 / ×2.99 | lognormal, GSD² 3.05 | -6.4 / +19.1 | 130.2 (Human toxicity, non-cancer_inorganics) | | Electricity, medium voltage, at grid [ES] | 3.900e-04 kWh | ×0.82 / ×1.22 | lognormal, GSD² 1.22 | -8.3 / +10.1 | 19.2 (Climate change-Land use and land use change) | | Water storage [CH] | 2.057e-11 p | ×0.335 / ×2.99 | lognormal, GSD² 3.05 | -2.3 / +6.8 | 30.2 (Land use) | | Pump station [CH] | 2.057e-11 p | ×0.335 / ×2.99 | lognormal, GSD² 3.05 | -1.2 / +3.5 | 13.7 (Resource use, minerals and metals) | | Ozone, liquid, at plant [RER] | 3.333e-06 kg | ×0.82 / ×1.22 | lognormal, GSD² 1.22 | -1.4 / +1.7 | 6.6 (Eutrophication, freshwater) | | Charcoal, at plant [GLO] | 4.170e-06 kg | ×0.82 / ×1.22 | lognormal, GSD² 1.22 | -0.5 / +0.6 | 19.5 (Climate change-Biogenic) | | Treatment, sewage, unpolluted, to wastewater treatment, class 3 [CH] | 1.766e-05 m3 | ×0.82 / ×1.22 | lognormal, GSD² 1.22 | -0.5 / +0.6 | 1.4 (Resource use, minerals and metals) | | Aluminium sulphate, powder, at plant [RER] | 6.330e-06 kg | ×0.82 / ×1.22 | lognormal, GSD² 1.22 | -0.2 / +0.3 | 2.8 (Acidification) | | Transport, freight, lorry, fleet average [CH] | 1.481e-06 tkm | ×0.484 / ×2.06 | lognormal, GSD² 2.1 | -0.1 / +0.2 | 0.5 (Ecotoxicity, freshwater_organics) | | Hydrogen peroxide, 50% in H2O, at plant [RER] | 8.800e-07 kg | ×0.82 / ×1.22 | lognormal, GSD² 1.22 | -0.1 / +0.1 | 0.2 (Ozone depletion) | | Transport, freight, rail [RER] | 8.888e-06 tkm | ×0.484 / ×2.06 | lognormal, GSD² 2.1 | -0.0 / +0.1 | 0.6 (Human toxicity, non-cancer_organics) | | Disposal, wood untreated, 20% water, to municipal incineration [CH] | 4.170e-06 kg | ×0.82 / ×1.22 | lognormal, GSD² 1.22 | -0.0 / +0.0 | 0.1 (Eutrophication marine) | | Chlorine, liquid, production mix, at plant [RER] | 1.000e-07 kg | ×0.82 / ×1.22 | lognormal, GSD² 1.22 | -0.0 / +0.0 | 1.0 (Ozone depletion) | | Aluminium [water/River] | 1.295e-06 kg | ×0.197 / ×5.09 | lognormal, GSD² 5.26 | -0.0 / +0.0 | 262.2 (Ecotoxicity, freshwater_inorganics) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== ^ Source ^ Scope ^ Value ^ This dataset ^ Ratio ^ Note ^ | bafu | Tap water, water balance according to MoeK 2013, at user [SE] | 1.104e-04 kg CO2 eq | 1.751e-04 | 1.59 | same dataset name, other location | | bafu | Tap water, water balance according to MoeK 2013, at user [NO] | 1.155e-04 kg CO2 eq | 1.751e-04 | 1.52 | same dataset name, other location | | bafu | Tap water, water balance according to MoeK 2013, at user [FR] | 1.231e-04 kg CO2 eq | 1.751e-04 | 1.42 | same dataset name, other location | | bafu | Tap water, water balance according to MoeK 2013, at user [CH] | 1.294e-04 kg CO2 eq | 1.751e-04 | 1.35 | same dataset name, other location | | bafu | Tap water, water balance according to MoeK 2013, at user [BR] | 1.330e-04 kg CO2 eq | 1.751e-04 | 1.32 | same dataset name, other location | | bafu | Tap water, water balance according to MoeK 2013, at user [MY] | 3.927e-04 kg CO2 eq | 1.751e-04 | 0.45 | same dataset name, other location | | bafu | Tap water, water balance according to MoeK 2013, at user [BA] | 4.279e-04 kg CO2 eq | 1.751e-04 | 0.41 | same dataset name, other location | | bafu | Tap water, water balance according to MoeK 2013, at user [RS] | 4.466e-04 kg CO2 eq | 1.751e-04 | 0.39 | same dataset name, other location | | bafu | Tap water, water balance according to MoeK 2013, at user [IN] | 4.719e-04 kg CO2 eq | 1.751e-04 | 0.37 | same dataset name, other location | | bafu | Tap water, water balance according to MoeK 2013, at user [ZA] | 4.961e-04 kg CO2 eq | 1.751e-04 | 0.35 | same dataset name, other location | ==== Conclusions and limitations ==== GWP100 1.751e-04 kg CO2 eq per kg (95 % interval 1.396e-04–3.102e-04). Dominant contributors: Electricity, medium voltage, at grid 46 %; Water works 23 %; Water supply network 10 %; Ozone, liquid, at plant 8 %; Water storage 3 %; Charcoal, at plant 3 %. Most sensitive: Water works [CH] (-15.6 / +46.5 %); Water supply network [CH] (-6.4 / +19.1 %); Electricity, medium voltage, at grid [ES] (-8.3 / +10.1 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kg | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.1e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 20/20 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 1.751e-04 in [1.396e-04, 3.102e-04] | | time period declared | **PASS** | 2000-01/2017-12 | | geography is a known location code | **PASS** | ES | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Stolz P., Frischknecht R. (2017) Life Cycle Water Use of Photovoltaic Electricity. Volume: 174. treeze Ltd.. Uster. Type: Separate publication Source: Report First author: Stolz P. Other authors: Frischknecht R. Year: 2017 Place of publication: Uster Publisher: treeze Ltd. Volume No: 174 — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].