====== Electricity, high voltage, photovoltaic mix slanted-roof, at grid — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:electricity_high_voltage_photovoltaic_mix_slanted_roof_at_grid__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity, high voltage, photovoltaic mix slanted-roof, at grid [CH], per 1 kWh. EF v3.1 climate change 0.03055 kg CO2 eq (Monte Carlo 95 % interval 0.02461–0.1256). Main contributors: Electricity, photovoltaic mix slanted-roof, at plant 92 %; Nitrous Oxide 4 %; Transmission network, electricity, high voltage 4 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Electricity, high voltage, photovoltaic mix slanted-roof, at grid | | Dataset UUID / graph id | ''%%4f59949a-a454-3c73-b19f-423d296b2c92%%'' / ''%%activity:electricity_high_voltage_photovoltaic_mix_slanted_roof_at_grid__ch%%'' | | Reference product, unit | Electricity, high voltage, photovoltaic mix slanted-roof, at grid, 1 kWh | | Location | CH — Data apply to public and self producers. Geographical classification according to IEA. Ozone- and NO2-emission factors are based on published measurements made in various countries. Assumptions for transmission network, losses and emissions are based on Swiss data. | | Time period | 2010-01/2010-12 | | Category | energy supply, kbob recommendation / electricity, delivered via network | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== This dataset describes the transmission of high voltage electricity.; UUID: 4f59949a-a454-3c73-b19f-423d296b2c92 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kWh** of Electricity, high voltage, photovoltaic mix slanted-roof, at grid (CH). All results are given per unit of the reference flow. ==== System boundary ==== Included are the electricity production in 0, the transmission network and direct emissions to air (ozone and N2O). Electricity losses are accounted for. ==== Technology ==== Average technology used to transmit and distribute electricity. Includes underground and overhead lines. Electricity production according to related datasets ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electricity, photovoltaic mix slanted-roof, at plant | technosphere | CH | 1.033 | kWh | lognormal, GSD² 1.24 | (3,1,1,1,3,1) | 92.0 | ██████████████████ | | | Transmission network, electricity, high voltage | technosphere | CH | 6.8199e-09 | km | lognormal, GSD² 3.16 | (3,1,4,5,3,5) | 3.5 | █ | | | Nitrous Oxide | elementary | air/Unknown | 5.0000e-06 | kg | lognormal, GSD² 1.5 | — | 4.5 | █ | | | Waste Heat | elementary | air/Unknown | 0.11293 | MJ | lognormal, GSD² 1.32 | (4,1,3,1,1,5) | 0.0 | · | | | Ozone | elementary | air/Unknown | 4.5000e-06 | kg | lognormal, GSD² 1.5 | — | 0.0 | · | | | Waste Heat | elementary | soil/Unknown | 0.0059435 | MJ | lognormal, GSD² 1.32 | (4,1,3,1,1,5) | 0.0 | · | | ==== Data quality ==== 4 of 6 direct exchanges carry a declared pedigree, 6 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.5 · completeness 1.0 · temporal 2.75 · geographical 2.0 · technological 2.0 · sample size 4.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: René Itten (ZHAW); data entry: René Itten (ZHAW); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | | | sampling procedure | statistics | | production volume | total electricity in Switzerland: 60 TWh | | uncertainty adjustments | none | | validation details | Proof reading validation: 08.05.2014; Other validation: G:\Projekte laufend\388 Aktualisierung PEF Energie\EcoSpold[388_60_electricity_from_grid-v0.3.xlsx]X-Process; | | time period comment | Time of publications. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **1.285e-04** | 1.097e-04 | 4.718e-04 | 2.11 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.304e-04** | 8.707e-05 | 7.718e-04 | 3.01 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.0304** | 0.0245 | 0.1247 | 2.22 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.864e-05** | 1.439e-05 | 6.600e-05 | 2.18 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.03055** | 0.02461 | 0.1256 | 2.22 | | EF-particulate Matter | Impact on human health | disease incidence | **1.083e-09** | 9.300e-10 | 9.923e-09 | 3.14 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.1738** | 0.1494 | 0.8966 | 2.49 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.003737** | 0.003358 | 0.01611 | 2.2 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.1775** | 0.1538 | 0.911 | 2.47 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **3.686e-05** | 2.987e-05 | 1.520e-04 | 2.31 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **2.588e-05** | 1.988e-05 | 1.958e-04 | 3.05 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **2.701e-04** | 2.264e-04 | 0.001068 | 2.21 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.275e-11** | 1.321e-11 | 6.986e-11 | 2.3 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.987e-12** | 6.296e-12 | 3.651e-11 | 2.37 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.074e-11** | 2.062e-11 | 9.692e-11 | 2.19 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.817e-10** | 8.702e-10 | 3.805e-09 | 2.12 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.771e-11** | 3.182e-11 | 1.159e-10 | 1.96 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **8.194e-10** | 9.095e-10 | 3.871e-09 | 2.1 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.007247** | 0.002675 | 0.08206 | 5.72 | | Land use | Soil quality index | pt (soil quality index) | **0.2141** | 0.1762 | 0.9618 | 2.37 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **1.065e-09** | 9.231e-10 | 4.431e-09 | 2.2 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **9.221e-05** | 7.906e-05 | 3.593e-04 | 2.17 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.388** | 0.3172 | 1.648 | 2.3 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **2.700e-06** | 2.214e-06 | 6.598e-06 | 1.72 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.01483** | -10.64 | 5.881 | — | Climate change 0.03055 kg CO2 eq per kWh. Main contributors: Electricity, photovoltaic mix slanted-roof, at plant 92 %; Nitrous Oxide 4 %; Transmission network, electricity, high voltage 4 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electricity, photovoltaic mix slanted-roof, at plant 92 %; Nitrous Oxide 4 %; Transmission network, electricity, high voltage 4 %. Most sensitive exchanges (Section 6.3): Electricity, photovoltaic mix slanted-roof, at plant [CH] (-17.2 / +21.2 %); Transmission network, electricity, high voltage [CH] (-2.4 / +7.4 %); Nitrous Oxide [air/Unknown] (-1.5 / +2.2 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh: ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 1.285e-04 | 1.354e-04 | 0.949 | | Climate change-Biogenic | 1.304e-04 | 1.304e-04 | 1.000 | | Climate change-Fossil | 0.0304 | 0.0304 | 1.000 | | Climate change-Land use and land use change | 1.864e-05 | 1.864e-05 | 1.000 | | Climate change | 0.03055 | 0.03055 | 1.000 | | EF-particulate Matter | 1.083e-09 | 1.083e-09 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.1738 | 0.1775 | 0.979 | | Ecotoxicity, freshwater_organics | 0.003737 | 0.003133 | 1.192 | | Ecotoxicity, freshwater | 0.1775 | 0.18 | 0.986 | | Eutrophication marine | 3.686e-05 | 3.686e-05 | 1.000 | | Eutrophication, freshwater | 2.588e-05 | 2.588e-05 | 1.000 | | Eutrophication, terrestrial | 2.701e-04 | 2.797e-04 | 0.966 | | Human toxicity, cancer_inorganics | 1.275e-11 | 1.268e-11 | 1.006 | | Human toxicity, cancer_organics | 7.987e-12 | 7.987e-12 | 1.000 | | Human toxicity, cancer | 2.074e-11 | 2.066e-11 | 1.004 | | Human toxicity, non-cancer_inorganics | 7.817e-10 | 7.775e-10 | 1.005 | | Human toxicity, non-cancer_organics | 3.771e-11 | 3.769e-11 | 1.001 | | Human toxicity, non-cancer | 8.194e-10 | 8.152e-10 | 1.005 | | Ionising radiation, human health | 0.007247 | 0.007247 | 1.000 | | Land use | 0.2141 | 0.1733 | 1.235 | | Ozone depletion | 1.065e-09 | 1.065e-09 | 1.000 | | Photochemical ozone formation - human health | 9.221e-05 | 9.221e-05 | 1.000 | | Resource use, fossils | 0.388 | 0.3881 | 1.000 | | Resource use, minerals and metals | 2.700e-06 | 2.684e-06 | 1.006 | | Water use | 0.01483 | 0.01475 | 1.005 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.03052 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 76.78 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Electricity, photovoltaic mix slanted-roof, at plant [CH] | 1.033 kWh | ×0.813 / ×1.23 | lognormal, GSD² 1.24 | -17.2 / +21.2 | 22.9 (Water use) | | Transmission network, electricity, high voltage [CH] | 6.820e-09 km | ×0.324 / ×3.09 | lognormal, GSD² 3.16 | -2.4 / +7.4 | 12.5 (EF-particulate Matter) | | Nitrous Oxide [air/Unknown] | 5.000e-06 kg | ×0.672 / ×1.49 | lognormal, GSD² 1.5 | -1.5 / +2.2 | 2.2 (Climate change-Fossil) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.03055 kg CO2 eq per kWh (95 % interval 0.02461–0.1256). Dominant contributors: Electricity, photovoltaic mix slanted-roof, at plant 92 %; Nitrous Oxide 4 %; Transmission network, electricity, high voltage 4 %. Most sensitive: Electricity, photovoltaic mix slanted-roof, at plant [CH] (-17.2 / +21.2 %); Transmission network, electricity, high voltage [CH] (-2.4 / +7.4 %); Nitrous Oxide [air/Unknown] (-1.5 / +2.2 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kWh | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 1.9e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 22/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 6/6 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.03055 in [0.02461, 0.1256] | | time period declared | **PASS** | 2010-01/2010-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Frischknecht R., Itten R., Tuchschmid M., (2010) Primärenergiefaktoren von Energiesystemen. Project reports. Volume: 387. ESU-services Ltd.. Uster, CH. — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].