====== Heat exchanger, heat pump Limmatschulhaus — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:heat_exchanger_heat_pump_limmatschulhaus__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Heat exchanger, heat pump Limmatschulhaus [CH], per 1 p. EF v3.1 climate change 2.845e+04 kg CO2 eq (Monte Carlo 95 % interval 2.429e+04–3.668e+04). Main contributors: Chromium steel 18/8, at plant 96 %; Natural gas, burned in industrial furnace 1MW 3 %; Electricity, medium voltage, at grid 1 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Heat exchanger, heat pump Limmatschulhaus | | Dataset UUID / graph id | ''%%571eeed3-cbb4-3b2e-9499-8343710cb065%%'' / ''%%activity:heat_exchanger_heat_pump_limmatschulhaus__ch%%'' | | Reference product, unit | Heat exchanger, heat pump Limmatschulhaus, 1 p | | Location | CH — This data represent the production in Switzerland. | | Time period | 2004-01/2004-12 | | Category | energy supply, kbob recommendation / heat pumps, waste water | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== This data set describes the production of the heat exchanger. Data stems from questionnaire.; UUID: 571eeed3-cbb4-3b2e-9499-8343710cb065 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Heat exchanger, heat pump Limmatschulhaus (CH). All results are given per unit of the reference flow. ==== System boundary ==== This data set includes energy and material requirements for the production of the heat exchanger as well as the disposal of waste water and waste. ==== Technology ==== The heat exchanger is made from steel 1.4571 and has an exchanger surface of 80 m2. It is 100 m long. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Chromium steel 18/8, at plant | technosphere | RER | 6156 | kg | lognormal, GSD² 1.21 | (1,1,1,1,3,1) | 95.6 | ███████████████████ | | | Natural gas, burned in industrial furnace 1MW | technosphere | CH | 10314 | MJ | lognormal, GSD² 1.21 | (1,1,1,1,3,1) | 2.8 | █ | | | Electricity, medium voltage, at grid | technosphere | CH | 3800 | kWh | lognormal, GSD² 1.05 | (1,1,1,1,1,1) | 1.2 | · | | | Welding, arc, steel | technosphere | RER | 782 | m | lognormal, GSD² 1.21 | (1,1,1,1,3,1) | 0.4 | · | | | Disposal, plastics, mixture, 15.3% water, to municipal incineration | technosphere | CH | 10 | kg | lognormal, GSD² 1.21 | (1,1,1,1,3,1) | 0.1 | · | | | Treatment, lorry production effluent, to wastewater treatment, class 1 | technosphere | CH | 5 | m3 | lognormal, GSD² 1.21 | (1,1,1,1,3,1) | 0.0 | · | | | Tap water, at user | technosphere | CH | 4000 | kg | lognormal, GSD² 1.21 | (1,1,1,1,3,1) | 0.0 | · | | | Disposal, paper, 11.2% water, to municipal incineration | technosphere | CH | 10 | kg | lognormal, GSD² 1.21 | (1,1,1,1,3,1) | 0.0 | · | | ==== Data quality ==== 8 of 8 direct exchanges carry a declared pedigree, 8 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 1.0 · completeness 1.0 · temporal 1.0 · geographical 1.0 · technological 2.75 · sample size 1.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Matthias Tuchschmid; data entry: Matthias Tuchschmid; validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | none | | sampling procedure | unknown | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: automatic validation in Excel; Other validation: none; | | time period comment | Actual data. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **129.6** | 105 | 180.9 | 1.32 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **87.25** | 57.01 | 205.1 | 1.88 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2.836e+04** | 2.42e+04 | 3.655e+04 | 1.24 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **6.159** | 5.308 | 9.542 | 1.34 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2.845e+04** | 2.429e+04 | 3.668e+04 | 1.24 | | EF-particulate Matter | Impact on human health | disease incidence | **0.002028** | 0.001623 | 0.00335 | 1.44 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **7.026e+04** | 5.928e+04 | 1.430e+05 | 1.55 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1250** | 1069 | 3.09e+04 | 5.14 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **7.151e+04** | 6.156e+04 | 1.552e+05 | 1.7 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **24.94** | 20.63 | 35.89 | 1.33 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **10.48** | 6.59 | 35.95 | 2.4 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **254.1** | 208.8 | 370.8 | 1.35 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.506e-05** | 2.680e-05 | 7.049e-05 | 1.64 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.839e-06** | 6.345e-06 | 1.258e-05 | 1.42 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **4.290e-05** | 3.458e-05 | 8.010e-05 | 1.54 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **0.001325** | 8.290e-04 | 0.004181 | 2.32 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.069e-05** | 9.148e-06 | 2.183e-05 | 1.57 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **0.001336** | 8.390e-04 | 0.004197 | 2.3 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **8312** | 3035 | 4.929e+04 | 4.24 | | Land use | Soil quality index | pt (soil quality index) | **1.547e+05** | 1.272e+05 | 3.038e+05 | 1.56 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **4.135e-04** | 3.314e-04 | 7.046e-04 | 1.47 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **92.48** | 78.77 | 139.4 | 1.33 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **3.571e+05** | 2.948e+05 | 5.150e+05 | 1.31 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.7494** | 0.5986 | 0.9938 | 1.3 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **1436** | -4.478e+07 | 2.345e+07 | — | Climate change 2.845e+04 kg CO2 eq per p. Main contributors: Chromium steel 18/8, at plant 96 %; Natural gas, burned in industrial furnace 1MW 3 %; Electricity, medium voltage, at grid 1 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Chromium steel 18/8, at plant 96 %; Natural gas, burned in industrial furnace 1MW 3 %; Electricity, medium voltage, at grid 1 %. Most sensitive exchanges (Section 6.3): Chromium steel 18/8, at plant [RER] (-16.1 / +19.4 %); Natural gas, burned in industrial furnace 1MW [CH] (-0.5 / +0.6 %); Welding, arc, steel [RER] (-0.1 / +0.1 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 129.6 | 139.6 | 0.929 | | Climate change-Biogenic | 87.25 | 87.25 | 1.000 | | Climate change-Fossil | 2.836e+04 | 2.836e+04 | 1.000 | | Climate change-Land use and land use change | 6.159 | 6.159 | 1.000 | | Climate change | 2.845e+04 | 2.845e+04 | 1.000 | | EF-particulate Matter | 0.002028 | 0.002028 | 1.000 | | Ecotoxicity, freshwater_inorganics | 7.026e+04 | 7.367e+04 | 0.954 | | Ecotoxicity, freshwater_organics | 1250 | 1243 | 1.006 | | Ecotoxicity, freshwater | 7.151e+04 | 7.487e+04 | 0.955 | | Eutrophication marine | 24.94 | 24.94 | 1.000 | | Eutrophication, freshwater | 10.48 | 10.48 | 1.000 | | Eutrophication, terrestrial | 254.1 | 265.3 | 0.958 | | Human toxicity, cancer_inorganics | 3.506e-05 | 3.497e-05 | 1.003 | | Human toxicity, cancer_organics | 7.839e-06 | 7.839e-06 | 1.000 | | Human toxicity, cancer | 4.290e-05 | 4.280e-05 | 1.002 | | Human toxicity, non-cancer_inorganics | 0.001325 | 0.001322 | 1.003 | | Human toxicity, non-cancer_organics | 1.069e-05 | 1.068e-05 | 1.000 | | Human toxicity, non-cancer | 0.001336 | 0.001333 | 1.002 | | Ionising radiation, human health | 8312 | 8312 | 1.000 | | Land use | 1.547e+05 | 1.182e+05 | 1.309 | | Ozone depletion | 4.135e-04 | 4.135e-04 | 1.000 | | Photochemical ozone formation - human health | 92.48 | 92.48 | 1.000 | | Resource use, fossils | 3.571e+05 | 3.572e+05 | 1.000 | | Resource use, minerals and metals | 0.7494 | 0.7486 | 1.001 | | Water use | 1436 | 1686 | 0.852 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 2.845e+04 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 7.208e+07 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Chromium steel 18/8, at plant [RER] | 6156 kg | ×0.831 / ×1.2 | lognormal, GSD² 1.21 | -16.1 / +19.4 | 20.3 (Resource use, minerals and metals) | | Natural gas, burned in industrial furnace 1MW [CH] | 1.031e+04 MJ | ×0.831 / ×1.2 | lognormal, GSD² 1.21 | -0.5 / +0.6 | 1.2 (Ozone depletion) | | Welding, arc, steel [RER] | 782 m | ×0.831 / ×1.2 | lognormal, GSD² 1.21 | -0.1 / +0.1 | 0.3 (EF-particulate Matter) | | Electricity, medium voltage, at grid [CH] | 3800 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.1 / +0.1 | 1.5 (Ionising radiation, human health) | | Disposal, plastics, mixture, 15.3% water, to municipal incineration [CH] | 10 kg | ×0.831 / ×1.2 | lognormal, GSD² 1.21 | -0.0 / +0.0 | 0.0 (Water use) | | Treatment, lorry production effluent, to wastewater treatment, class 1 [CH] | 5 m3 | ×0.831 / ×1.2 | lognormal, GSD² 1.21 | -0.0 / +0.0 | 0.0 (Human toxicity, cancer_inorganics) | | Tap water, at user [CH] | 4000 kg | ×0.831 / ×1.2 | lognormal, GSD² 1.21 | -0.0 / +0.0 | 0.0 (Water use) | | Disposal, paper, 11.2% water, to municipal incineration [CH] | 10 kg | ×0.831 / ×1.2 | lognormal, GSD² 1.21 | -0.0 / +0.0 | 0.0 (Water use) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 2.845e+04 kg CO2 eq per p (95 % interval 2.429e+04–3.668e+04). Dominant contributors: Chromium steel 18/8, at plant 96 %; Natural gas, burned in industrial furnace 1MW 3 %; Electricity, medium voltage, at grid 1 %. Most sensitive: Chromium steel 18/8, at plant [RER] (-16.1 / +19.4 %); Natural gas, burned in industrial furnace 1MW [CH] (-0.5 / +0.6 %); Welding, arc, steel [RER] (-0.1 / +0.1 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.6e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 22/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 8/8 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 2.845e+04 in [2.429e+04, 3.668e+04] | | time period declared | **PASS** | 2004-01/2004-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Rolf Frischknecht, Mireille Faist Emmenegger (2004) Nutzwärmebereitstellung mit Wärmepumpe für Rohabwasser. Uster. Type: Separate publication Source: Interner Bericht First author: Rolf Frischknecht Other authors: Mireille Faist Emmenegger Year: 2004 Place of publication: Uster — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].