====== Heat pump, air-water, 15kW — RER ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:heat_pump_air_water_15kw__rer|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Heat pump, air-water, 15kW [RER], per 1 p. EF v3.1 climate change 1840 kg CO2 eq (Monte Carlo 95 % interval 1644–2676). Main contributors: Electronic component, unspecified, at plant 20 %; Steel, low-alloyed, at plant 19 %; Aluminium, primary, at plant 15 %; Pentafluoroethane 14 %; Electricity, medium voltage, production ENTSO-E, at grid 9 %; Natural gas, burned in industrial furnace 1MWth 7 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Heat pump, air-water, 15kW | | Dataset UUID / graph id | ''%%571f4171-b256-31f5-b54b-fe3b5cb0a5d5%%'' / ''%%activity:heat_pump_air_water_15kw__rer%%'' | | Reference product, unit | Heat pump, air-water, 15kW, 1 p | | Location | RER — Data apply to the supply in Switzerland. | | Time period | 2016-01/2020-12 | | Category | heat / heat pumps\heating systems | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Inventory for the production of an air-water heat pump, 15kW with a life time of 20 years.; Synonyms: Wärmepumpe mit Wärmetauscher Luft/ Wasser 15kW; UUID: 571f4171-b256-31f5-b54b-fe3b5cb0a5d5 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Heat pump, air-water, 15kW (RER). All results are given per unit of the reference flow. ==== System boundary ==== Infrastructure of the air-water heat pump including all material inputs (pipes, air heat exchanger, coolant) and also the energy use for the construction of the heat pump components. ==== Technology ==== Industry data. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electronic component, unspecified, at plant | technosphere | GLO | 2 | kg | lognormal, GSD² 1.4 | — | 19.7 | ████ | | | Steel, low-alloyed, at plant | technosphere | RER | 159.7 | kg | lognormal, GSD² 1.4 | — | 18.6 | ████ | | | Aluminium, primary, at plant | technosphere | RER | 30 | kg | lognormal, GSD² 1.4 | — | 14.5 | ███ | | | Electricity, medium voltage, production ENTSO-E, at grid | technosphere | ENTSO-E | 589.84 | kWh | lognormal, GSD² 1.55 | — | 8.8 | ██ | | | Natural gas, burned in industrial furnace 1MWth | technosphere | CH | 1586.2 | MJ | lognormal, GSD² 1.22 | — | 6.6 | █ | | | Copper, at regional storage | technosphere | RER | 60.2 | kg | lognormal, GSD² 1.4 | — | 5.3 | █ | | | Tube insulation, elastomere, at plant | technosphere | DE | 13.9 | kg | lognormal, GSD² 1.4 | — | 3.4 | █ | | | Disposal, plastics, mixture, 15.3% water, to municipal incineration | technosphere | CH | 15.3 | kg | lognormal, GSD² 1.4 | — | 2.0 | · | | | Heat, biomethane, at industrial furnace 1MW | technosphere | CH | 745.56 | MJ | lognormal, GSD² 1.55 | — | 1.6 | · | | | Trifluoromethane, at plant | technosphere | GLO | 2.25 | kg | lognormal, GSD² 1.62 | — | 1.2 | · | | | 1,1-difluoroethane, HFC-152a, at plant | technosphere | US | 2.25 | kg | lognormal, GSD² 1.62 | — | 0.6 | · | | | Rock wool, at plant | technosphere | CH | 5 | kg | lognormal, GSD² 1.31 | — | 0.3 | · | | | Light fuel oil, burned in industrial furnace 1MW, non-modulating | technosphere | RER | 50.04 | MJ | lognormal, GSD² 1.22 | — | 0.3 | · | | | Polyvinylchloride, bulk polymerised, at plant | technosphere | RER | 1.4 | kg | lognormal, GSD² 1.4 | — | 0.2 | · | | | Heat, mixed chips from forest, at furnace 1000kW | technosphere | CH | 604.44 | MJ | lognormal, GSD² 1.55 | — | 0.2 | · | | | Lubricating oil, at plant | technosphere | RER | 2.2 | kg | lognormal, GSD² 1.55 | — | 0.2 | · | | | Transport, freight, rail | technosphere | RER | 162.6 | tkm | lognormal, GSD² 2.34 | — | 0.1 | · | | | Transport, freight, lorry, 16t-32t gross weight, fleet average | technosphere | CH | 13.55 | tkm | lognormal, GSD² 2.34 | — | 0.1 | · | | | Pentafluoroethane | elementary | air/Ground level / Urban (>1000 people/s… | 0.0675 | kg | lognormal, GSD² 1.56 | — | 13.7 | ███ | | | Difluoromethane | elementary | air/Ground level / Urban (>1000 people/s… | 0.0675 | kg | lognormal, GSD² 1.56 | — | 2.8 | █ | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 2123.4 | MJ | lognormal, GSD² 1.4 | — | 0.0 | · | | | Industrial area | elementary | natural resource | 8.7422 | m2.a | lognormal, GSD² 1.57 | — | 0.0 | · | | | Industrial area | elementary | natural resource | 2.4101 | m2.a | lognormal, GSD² 1.57 | — | 0.0 | · | | | Water | elementary | natural resource | 1.009 | m3 | lognormal, GSD² 1.4 | — | 0.0 | · | | ==== Data quality ==== 0 of 24 direct exchanges carry a declared pedigree, 24 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Cyrill Kern (CARBOTECH); data entry: Thomas Kaegi (CARBOTECH); validation (proof reading): Andy Spoerri (EBP) | | extrapolations | | | sampling procedure | Data provided by manufacturer | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: 19.02.2021; Other validation: Z:\Schreibtisch\WinShare\BAFU Heizsysteme\A_zum konvertieren\WP[EcoSpold_heat pump, air-water _v0.3.xlsx]X-Process; | | time period comment | undefined | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **14.54** | 11.74 | 21.85 | 1.36 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **23.62** | 16 | 41.53 | 1.63 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1815** | 1618 | 2649 | 1.28 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.9034** | 0.7168 | 1.493 | 1.45 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1840** | 1644 | 2676 | 1.28 | | EF-particulate Matter | Impact on human health | disease incidence | **9.196e-05** | 8.363e-05 | 1.489e-04 | 1.34 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **8449** | 7469 | 2.232e+04 | 1.77 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **285.6** | 246.1 | 540.1 | 1.57 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **8735** | 7781 | 2.281e+04 | 1.75 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **1.936** | 1.58 | 4.028 | 1.6 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **5.864** | 3.343 | 42.58 | 3.62 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **18.86** | 15.24 | 33.49 | 1.5 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.017e-06** | 1.821e-06 | 5.916e-06 | 1.87 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.137e-07** | 5.968e-07 | 1.248e-06 | 1.48 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.731e-06** | 2.512e-06 | 7.003e-06 | 1.7 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.556e-04** | 1.291e-04 | 4.712e-04 | 1.97 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.047e-05** | 6.289e-06 | 1.991e-05 | 1.79 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.661e-04** | 1.403e-04 | 4.837e-04 | 1.93 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **561.4** | 197.7 | 3634 | 4.48 | | Land use | Soil quality index | pt (soil quality index) | **1.705e+04** | 1.441e+04 | 2.814e+04 | 1.4 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **0.002944** | 0.001288 | 0.007097 | 2.38 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **6.51** | 5.711 | 11.05 | 1.4 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **2.147e+04** | 1.901e+04 | 3.576e+04 | 1.37 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.4551** | 0.2437 | 1.171 | 2.25 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **207.3** | -6.010e+05 | 2.987e+05 | — | Climate change 1840 kg CO2 eq per p. Main contributors: Electronic component, unspecified, at plant 20 %; Steel, low-alloyed, at plant 19 %; Aluminium, primary, at plant 15 %; Pentafluoroethane 14 %; Electricity, medium voltage, production ENTSO-E, at grid 9 %; Natural gas, burned in industrial furnace 1MWth 7 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electronic component, unspecified, at plant 20 %; Steel, low-alloyed, at plant 19 %; Aluminium, primary, at plant 15 %; Pentafluoroethane 14 %; Electricity, medium voltage, production ENTSO-E, at grid 9 %; Natural gas, burned in industrial furnace 1MWth 7 %. Most sensitive exchanges (Section 6.3): Electronic component, unspecified, at plant [GLO] (-5.5 / +7.6 %); Steel, low-alloyed, at plant [RER] (-5.2 / +7.2 %); Pentafluoroethane [air/Ground level / Urban (>1000 people/square mile)] (-4.8 / +7.5 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 14.54 | 16.22 | 0.896 | | Climate change-Biogenic | 23.62 | 23.62 | 1.000 | | Climate change-Fossil | 1815 | 1815 | 1.000 | | Climate change-Land use and land use change | 0.9034 | 0.9034 | 1.000 | | Climate change | 1840 | 1840 | 1.000 | | EF-particulate Matter | 9.196e-05 | 9.196e-05 | 1.000 | | Ecotoxicity, freshwater_inorganics | 8449 | 8770 | 0.963 | | Ecotoxicity, freshwater_organics | 285.6 | 269.3 | 1.061 | | Ecotoxicity, freshwater | 8735 | 8911 | 0.980 | | Eutrophication marine | 1.936 | 1.935 | 1.000 | | Eutrophication, freshwater | 5.864 | 5.864 | 1.000 | | Eutrophication, terrestrial | 18.86 | 19.85 | 0.950 | | Human toxicity, cancer_inorganics | 2.017e-06 | 2.005e-06 | 1.006 | | Human toxicity, cancer_organics | 7.137e-07 | 7.137e-07 | 1.000 | | Human toxicity, cancer | 2.731e-06 | 2.719e-06 | 1.004 | | Human toxicity, non-cancer_inorganics | 1.556e-04 | 1.549e-04 | 1.005 | | Human toxicity, non-cancer_organics | 1.047e-05 | 1.047e-05 | 1.000 | | Human toxicity, non-cancer | 1.661e-04 | 1.654e-04 | 1.004 | | Ionising radiation, human health | 561.4 | 561.4 | 1.000 | | Land use | 1.705e+04 | 1.209e+04 | 1.410 | | Ozone depletion | 0.002944 | 0.002944 | 1.000 | | Photochemical ozone formation - human health | 6.51 | 6.51 | 1.000 | | Resource use, fossils | 2.147e+04 | 2.148e+04 | 1.000 | | Resource use, minerals and metals | 0.4551 | 0.4548 | 1.001 | | Water use | 207.3 | 194.5 | 1.066 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 1840 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 5.878e+06 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Electronic component, unspecified, at plant [GLO] | 2 kg | ×0.721 / ×1.39 | lognormal, GSD² 1.4 | -5.5 / +7.6 | 32.5 (Resource use, minerals and metals) | | Steel, low-alloyed, at plant [RER] | 159.7 kg | ×0.721 / ×1.39 | lognormal, GSD² 1.4 | -5.2 / +7.2 | 9.8 (EF-particulate Matter) | | Pentafluoroethane [air/Ground level / Urban (>1000 people/square mile)] | 0.0675 kg | ×0.647 / ×1.55 | lognormal, GSD² 1.56 | -4.8 / +7.5 | 7.6 (Climate change-Fossil) | | Aluminium, primary, at plant [RER] | 30 kg | ×0.721 / ×1.39 | lognormal, GSD² 1.4 | -4.0 / +5.6 | 16.2 (Climate change-Land use and land use change) | | Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] | 589.8 kWh | ×0.652 / ×1.53 | lognormal, GSD² 1.55 | -3.1 / +4.7 | 20.3 (Ionising radiation, human health) | | Copper, at regional storage [RER] | 60.2 kg | ×0.721 / ×1.39 | lognormal, GSD² 1.4 | -1.5 / +2.0 | 35.1 (Human toxicity, non-cancer_organics) | | Difluoromethane [air/Ground level / Urban (>1000 people/square mile)] | 0.0675 kg | ×0.647 / ×1.55 | lognormal, GSD² 1.56 | -1.0 / +1.5 | 1.6 (Climate change-Fossil) | | Natural gas, burned in industrial furnace 1MWth [CH] | 1586 MJ | ×0.826 / ×1.21 | lognormal, GSD² 1.22 | -1.1 / +1.4 | 1.9 (Resource use, fossils) | | Tube insulation, elastomere, at plant [DE] | 13.9 kg | ×0.721 / ×1.39 | lognormal, GSD² 1.4 | -0.9 / +1.3 | 3.6 (Climate change-Land use and land use change) | | Heat, biomethane, at industrial furnace 1MW [CH] | 745.6 MJ | ×0.652 / ×1.53 | lognormal, GSD² 1.55 | -0.6 / +0.9 | 38.6 (Climate change-Biogenic) | | Disposal, plastics, mixture, 15.3% water, to municipal incineration [CH] | 15.3 kg | ×0.721 / ×1.39 | lognormal, GSD² 1.4 | -0.6 / +0.8 | 0.8 (Climate change-Fossil) | | Trifluoromethane, at plant [GLO] | 2.25 kg | ×0.621 / ×1.61 | lognormal, GSD² 1.62 | -0.4 / +0.7 | 59.6 (Ozone depletion) | | 1,1-difluoroethane, HFC-152a, at plant [US] | 2.25 kg | ×0.621 / ×1.61 | lognormal, GSD² 1.62 | -0.2 / +0.4 | 0.5 (Water use) | | Transport, freight, rail [RER] | 162.6 tkm | ×0.435 / ×2.3 | lognormal, GSD² 2.34 | -0.1 / +0.2 | 0.7 (Land use) | | Transport, freight, lorry, 16t-32t gross weight, fleet average [CH] | 13.55 tkm | ×0.435 / ×2.3 | lognormal, GSD² 2.34 | -0.1 / +0.2 | 0.3 (Photochemical ozone formation - human health) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 1840 kg CO2 eq per p (95 % interval 1644–2676). Dominant contributors: Electronic component, unspecified, at plant 20 %; Steel, low-alloyed, at plant 19 %; Aluminium, primary, at plant 15 %; Pentafluoroethane 14 %; Electricity, medium voltage, production ENTSO-E, at grid 9 %; Natural gas, burned in industrial furnace 1MWth 7 %. Most sensitive: Electronic component, unspecified, at plant [GLO] (-5.5 / +7.6 %); Steel, low-alloyed, at plant [RER] (-5.2 / +7.2 %); Pentafluoroethane [air/Ground level / Urban (>1000 people/square mile)] (-4.8 / +7.5 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.1e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 24/24 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 1840 in [1644, 2676] | | time period declared | **PASS** | 2016-01/2020-12 | | geography is a known location code | **PASS** | RER | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Kägi Thomas, Livia Waldburger, Cyril Kern, Gavin Roberts, Mischa Zschokke, Flora Conte, Lea Weber (2020) LCI of heating systems. Carbotech im Auftrag des BAFU. Carbotech AG. Zürich. CH. Type: Separate publication Source: Report First author: Kägi Thomas Other authors: Livia Waldburger, Cyril Kern, Gavin Roberts, Mischa Zschokke, Flora Conte, Lea Weber Year: 2020 Title of anthology: Carbotech im Au… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].