====== xxx Electricity, consumer mix, Bereich 1 — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:xxx_electricity_consumer_mix_bereich_1__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset xxx Electricity, consumer mix, Bereich 1 [CH], per 1 kWh. EF v3.1 climate change 0.03508 kg CO2 eq (Monte Carlo 95 % interval 0.03448–0.04364). Main contributors: Electricity, hard coal, at power plant 32 %; Disposal, municipal solid waste, 22.9% water, to municipal i… 21 %; Electricity, residual mix 7 %; Electricity, from natural gas 7 %; Electricity, at cogen 300kWth, natural gas, allocation exerg… 4 %; Electricity, nuclear, at power plant pressure water reactor 4 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | xxx Electricity, consumer mix, Bereich 1 | | Dataset UUID / graph id | ''%%57647374-f5f3-3a80-876b-8daf8b268bb6%%'' / ''%%activity:xxx_electricity_consumer_mix_bereich_1__ch%%'' | | Reference product, unit | xxx Electricity, consumer mix, Bereich 1, 1 kWh | | Location | CH — Data apply to public and self producers in Switzerland and from imports. | | Time period | 2018-01/2018-12 | | Category | electricity / notMaintained | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Electricity domestic net production shares are based on annual averages for the year 2018.; UUID: 57647374-f5f3-3a80-876b-8daf8b268bb6 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kWh** of xxx Electricity, consumer mix, Bereich 1 (CH). All results are given per unit of the reference flow. ==== System boundary ==== Included are the shares of domestic electricity production and imports by technology at the busbar. Not included are transformation, transport or distribution losses ==== Technology ==== No technology description is provided because the dataset just describes the power plant portfolio of the respective country using current average technology per energy carrier. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electricity, hard coal, at power plant | technosphere | DE | 0.011069 | kWh | lognormal, GSD² 1.07 | — | 32.3 | ██████ | | | Disposal, municipal solid waste, 22.9% water, to municipal incineration | technosphere | CH | 0.014446 | kg | lognormal, GSD² 1.07 | — | 21.5 | ████ | | | Electricity, residual mix | technosphere | CH | 0.06652 | kWh | lognormal, GSD² 1.07 | — | 6.6 | █ | | | Electricity, from natural gas | technosphere | ENTSO-E | 0.0045766 | kWh | lognormal, GSD² 1.07 | — | 6.6 | █ | | | Electricity, at cogen 300kWth, natural gas, allocation exergy | technosphere | CH | 0.0023415 | kWh | lognormal, GSD² 1.07 | — | 4.1 | █ | | | Electricity, nuclear, at power plant pressure water reactor | technosphere | CH | 0.10272 | kWh | lognormal, GSD² 1.07 | — | 4.0 | █ | | | Electricity, hydropower, net, at reservoir power plant | technosphere | CH | 0.27684 | kWh | lognormal, GSD² 1.07 | — | 4.0 | █ | | | Electricity, nuclear, at power plant boiling water reactor | technosphere | CH | 0.080978 | kWh | lognormal, GSD² 1.07 | — | 3.6 | █ | | | Electricity, at cogen 300kWth, biomethane, allocation exergy | technosphere | CH | 0.003527 | kWh | lognormal, GSD² 1.07 | — | 3.2 | █ | | | Electricity, hydropower, at run-of-river power plant | technosphere | CH | 0.22619 | kWh | lognormal, GSD² 1.07 | — | 2.3 | · | | | Disposal, biowaste, 60% H2O, to municipal incineration, allocation price | technosphere | CH | 0.020776 | kg | lognormal, GSD² 1.07 | — | 2.3 | · | | | Electricity, production mix photovoltaic, at plant | technosphere | CH | 0.023716 | kWh | lognormal, GSD² 1.07 | — | 2.0 | · | | | Electricity, hydropower, at run-of-river power plant | technosphere | RER | 0.14242 | kWh | lognormal, GSD² 1.07 | — | 1.5 | · | | | Disposal, paper, 11.2% water, to municipal incineration | technosphere | CH | 0.011522 | kg | lognormal, GSD² 1.07 | — | 1.3 | · | | | Electricity, hydropower, at reservoir power plant, non alpine regions | technosphere | RER | 0.027127 | kWh | lognormal, GSD² 1.07 | — | 1.3 | · | | | Electricity, at cogen with biogas engine, agricultural covered, alloc. exergy | technosphere | CH | 0.0022944 | kWh | lognormal, GSD² 1.07 | — | 1.0 | · | | | Electricity, hydropower, at small hydropower plant | technosphere | CH | 0.056933 | kWh | lognormal, GSD² 1.07 | — | 0.8 | · | | | Electricity, at cogen 1MWth, wood chips, allocation exergy | technosphere | CH | 0.0042082 | kWh | lognormal, GSD² 1.07 | — | 0.7 | · | | | Electricity, at cogen 300kWth, diesel, allocation exergy | technosphere | CH | 2.1286e-04 | kWh | lognormal, GSD² 1.07 | — | 0.5 | · | | | Electricity, at wind farm | technosphere | RER | 0.0040444 | kWh | lognormal, GSD² 1.07 | — | 0.2 | · | | | Electricity, at wind farm | technosphere | CH | 0.0022268 | kWh | lognormal, GSD² 1.07 | — | 0.1 | · | | | Electricity, at cogen 1MWth, wood chips, allocation exergy | technosphere | CH | 5.9274e-04 | kWh | lognormal, GSD² 1.07 | — | 0.1 | · | | | Electricity, production mix photovoltaic, at plant | technosphere | DE | 1.0643e-04 | kWh | lognormal, GSD² 1.07 | — | 0.0 | · | | | Electricity, nuclear, at power plant pressure water reactor | technosphere | FR | 3.1930e-04 | kWh | lognormal, GSD² 1.07 | — | 0.0 | · | | | Electricity from waste, at municipal waste incineration plant | technosphere | CH | 0.0018815 | kWh | lognormal, GSD² 1.07 | — | -0.0 | · | | ==== Data quality ==== 0 of 25 direct exchanges carry a declared pedigree, 25 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Philippe Stolz (TREEZE); data entry: Luana Krebs (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | | | sampling procedure | Statistical data | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: automatic validation in Excel; Other validation: G:\Projekte laufend\726 Umweltbilanz Strommix Schweiz 2018\EcoSpold[726-Strommix-Schweiz-2018-v0.6.xlsx]X-Process; | | time period comment | Time period of statistics used. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **6.289e-05** | 6.370e-05 | 8.363e-05 | 1.16 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **9.788e-04** | 7.903e-04 | 0.001329 | 1.32 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.03341** | 0.03271 | 0.04181 | 1.14 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **6.869e-04** | 4.692e-04 | 0.001108 | 1.54 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.03508** | 0.03448 | 0.04364 | 1.13 | | EF-particulate Matter | Impact on human health | disease incidence | **2.458e-09** | 1.975e-09 | 4.255e-09 | 1.47 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.1274** | 0.121 | 0.2313 | 1.39 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.001311** | 0.001333 | 0.00302 | 1.59 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.1287** | 0.1228 | 0.2339 | 1.38 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **3.269e-05** | 3.207e-05 | 5.071e-05 | 1.27 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **1.155e-05** | 8.455e-06 | 1.352e-04 | 3.99 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **2.594e-04** | 2.501e-04 | 4.080e-04 | 1.28 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.389e-12** | 7.729e-12 | 2.480e-11 | 1.82 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.543e-11** | 1.097e-11 | 2.506e-11 | 1.54 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.282e-11** | 2.129e-11 | 4.496e-11 | 1.45 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.895e-10** | 4.053e-10 | 1.389e-09 | 1.93 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.270e-11** | 1.205e-11 | 2.118e-11 | 1.32 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **4.022e-10** | 4.193e-10 | 1.406e-09 | 1.91 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.3791** | 0.1413 | 2.116 | 4.14 | | Land use | Soil quality index | pt (soil quality index) | **0.6205** | 0.3976 | 1.067 | 1.65 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **9.894e-09** | 8.406e-09 | 1.195e-08 | 1.2 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **7.620e-05** | 7.498e-05 | 1.275e-04 | 1.31 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **3.528** | 3.17 | 4.382 | 1.18 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **1.037e-07** | 1.003e-07 | 1.874e-07 | 1.39 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.03635** | -408.5 | 207.1 | — | Climate change 0.03508 kg CO2 eq per kWh. Main contributors: Electricity, hard coal, at power plant 32 %; Disposal, municipal solid waste, 22.9% water, to municipal i… 21 %; Electricity, residual mix 7 %; Electricity, from natural gas 7 %; Electricity, at cogen 300kWth, natural gas, allocation exerg… 4 %; Electricity, nuclear, at power plant pressure water reactor 4 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electricity, hard coal, at power plant 32 %; Disposal, municipal solid waste, 22.9% water, to municipal i… 21 %; Electricity, residual mix 7 %; Electricity, from natural gas 7 %; Electricity, at cogen 300kWth, natural gas, allocation exerg… 4 %; Electricity, nuclear, at power plant pressure water reactor 4 %. Most sensitive exchanges (Section 6.3): Electricity, hard coal, at power plant [DE] (-2.1 / +2.3 %); Disposal, municipal solid waste, 22.9% water, to municipal incineration [CH] (-1.4 / +1.5 %); Electricity, residual mix [CH] (-0.4 / +0.5 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh: ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 6.289e-05 | 8.947e-05 | 0.703 | | Climate change-Biogenic | 9.788e-04 | 9.788e-04 | 1.000 | | Climate change-Fossil | 0.03341 | 0.0334 | 1.000 | | Climate change-Land use and land use change | 6.869e-04 | 6.869e-04 | 1.000 | | Climate change | 0.03508 | 0.03507 | 1.000 | | EF-particulate Matter | 2.458e-09 | 2.458e-09 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.1274 | 0.137 | 0.930 | | Ecotoxicity, freshwater_organics | 0.001311 | 0.001263 | 1.038 | | Ecotoxicity, freshwater | 0.1287 | 0.1382 | 0.931 | | Eutrophication marine | 3.269e-05 | 3.240e-05 | 1.009 | | Eutrophication, freshwater | 1.155e-05 | 1.155e-05 | 1.000 | | Eutrophication, terrestrial | 2.594e-04 | 2.856e-04 | 0.908 | | Human toxicity, cancer_inorganics | 7.389e-12 | 7.164e-12 | 1.031 | | Human toxicity, cancer_organics | 1.543e-11 | 1.543e-11 | 1.000 | | Human toxicity, cancer | 2.282e-11 | 2.259e-11 | 1.010 | | Human toxicity, non-cancer_inorganics | 3.895e-10 | 3.734e-10 | 1.043 | | Human toxicity, non-cancer_organics | 1.270e-11 | 1.270e-11 | 0.999 | | Human toxicity, non-cancer | 4.022e-10 | 3.861e-10 | 1.042 | | Ionising radiation, human health | 0.3791 | 0.3791 | 1.000 | | Land use | 0.6205 | 0.4847 | 1.280 | | Ozone depletion | 9.894e-09 | 9.893e-09 | 1.000 | | Photochemical ozone formation - human health | 7.620e-05 | 7.627e-05 | 0.999 | | Resource use, fossils | 3.528 | 3.527 | 1.000 | | Resource use, minerals and metals | 1.037e-07 | 1.014e-07 | 1.023 | | Water use | 0.03635 | 0.0395 | 0.920 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.03507 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 194.5 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Electricity, hard coal, at power plant [DE] | 0.01107 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -2.1 / +2.3 | 3.7 (Eutrophication, freshwater) | | Disposal, municipal solid waste, 22.9% water, to municipal incineration [CH] | 0.01445 kg | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -1.4 / +1.5 | 1.7 (Human toxicity, cancer_inorganics) | | Electricity, residual mix [CH] | 0.06652 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.4 / +0.5 | 2.3 (Land use) | | Electricity, from natural gas [ENTSO-E] | 0.004577 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.4 / +0.5 | 0.9 (Ecotoxicity, freshwater_organics) | | Electricity, at cogen 300kWth, natural gas, allocation exergy [CH] | 0.002341 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.3 / +0.3 | 0.6 (Ecotoxicity, freshwater_organics) | | Electricity, nuclear, at power plant pressure water reactor [CH] | 0.1027 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.3 / +0.3 | 3.3 (Ozone depletion) | | Electricity, hydropower, net, at reservoir power plant [CH] | 0.2768 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.3 / +0.3 | 3.8 (Climate change-Land use and land use change) | | Electricity, nuclear, at power plant boiling water reactor [CH] | 0.08098 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.2 / +0.2 | 3.1 (Ozone depletion) | | Electricity, at cogen 300kWth, biomethane, allocation exergy [CH] | 0.003527 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.2 / +0.2 | 4.7 (Climate change-Biogenic) | | Electricity, hydropower, at run-of-river power plant [CH] | 0.2262 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.2 / +0.2 | 0.6 (Human toxicity, non-cancer_organics) | | Disposal, biowaste, 60% H2O, to municipal incineration, allocation price [CH] | 0.02078 kg | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.2 / +0.2 | 1.4 (Human toxicity, cancer_inorganics) | | Electricity, production mix photovoltaic, at plant [CH] | 0.02372 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.1 / +0.1 | 4.3 (Resource use, minerals and metals) | | Electricity, hydropower, at run-of-river power plant [RER] | 0.1424 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.1 / +0.1 | 0.4 (Human toxicity, non-cancer_organics) | | Disposal, paper, 11.2% water, to municipal incineration [CH] | 0.01152 kg | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.1 / +0.1 | 1.1 (Human toxicity, cancer_inorganics) | | Electricity, hydropower, at reservoir power plant, non alpine regions [RER] | 0.02713 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.1 / +0.1 | 3.0 (Climate change-Land use and land use change) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.03508 kg CO2 eq per kWh (95 % interval 0.03448–0.04364). Dominant contributors: Electricity, hard coal, at power plant 32 %; Disposal, municipal solid waste, 22.9% water, to municipal i… 21 %; Electricity, residual mix 7 %; Electricity, from natural gas 7 %; Electricity, at cogen 300kWth, natural gas, allocation exerg… 4 %; Electricity, nuclear, at power plant pressure water reactor 4 %. Most sensitive: Electricity, hard coal, at power plant [DE] (-2.1 / +2.3 %); Disposal, municipal solid waste, 22.9% water, to municipal incineration [CH] (-1.4 / +1.5 %); Electricity, residual mix [CH] (-0.4 / +0.5 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kWh | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 4.4e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 19/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 25/25 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.03508 in [0.03448, 0.04364] | | time period declared | **PASS** | 2018-01/2018-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Krebs L., Stolz P., Frischknecht R. (2020) Umweltbilanz Strommix Schweiz 2018. Project reports. Volume: 723. treeze Ltd.. Uster, CH. Type: Separate publication First author: Krebs L. Other authors: Stolz P., Frischknecht R. Year: 2020 Title of anthology: Project reports Place of publication: Uster, CH Publisher: treeze Ltd. Volume No: 723 — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].