====== Cogen unit 200kWe diesel SCR, common components for heat+electricity — RER ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:cogen_unit_200kwe_diesel_scr_common_components_for_heat_plus_electricity__rer|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Cogen unit 200kWe diesel SCR, common components for heat+electricity [RER], per 1 p. EF v3.1 climate change 9.322e+04 kg CO2 eq (Monte Carlo 95 % interval 8.222e+04–1.238e+05). Main contributors: Maintenance, cogen unit 160kWe 30 %; Control cabinet cogen unit 160kWe 17 %; Gas motor 206kW 12 %; Planning, cogen unit 160kWe 8 %; Steel, converter, unalloyed, at plant 8 %; Assembly, module cogen unit 160kWe 4 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Cogen unit 200kWe diesel SCR, common components for heat+electricity | | Dataset UUID / graph id | ''%%5e24cd07-20bf-31d2-b8f4-40bdf14cc4f9%%'' / ''%%activity:cogen_unit_200kwe_diesel_scr_common_components_for_heat_plus_electricity__rer%%'' | | Reference product, unit | Cogen unit 200kWe diesel SCR, common components for heat+electricity, 1 p | | Location | RER — Extrapolated from data of a plant in Switzerland, assumed valid for Europe (RER). | | Time period | 1990-01/2000-12 | | Category | heat / oil\cogeneration\power unit\infrastructure | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== The module summarises infrastructure components of a cogeneration unit. ; Synonyms: Selective Catalytic Reduction, SCR; UUID: 5e24cd07-20bf-31d2-b8f4-40bdf14cc4f9 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Cogen unit 200kWe diesel SCR, common components for heat+electricity (RER). All results are given per unit of the reference flow. ==== System boundary ==== The module includes all shared components for heat and electricity production. Includes also SCR and oxidation catalytic converter. ==== Technology ==== Partly extrapolated from data of a 160kWe lambda=1 natural gas plant, adjusted to diesel cogen with SCR and oxidation catalytic converters. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Maintenance, cogen unit 160kWe | technosphere | RER | 1 | p | lognormal, GSD² 1.5 | — | 30.0 | ██████ | | | Control cabinet cogen unit 160kWe | technosphere | RER | 1 | p | lognormal, GSD² 1.3 | — | 16.6 | ███ | | | Gas motor 206kW | technosphere | RER | 2.5 | p | lognormal, GSD² 1.7 | — | 11.6 | ██ | | | Planning, cogen unit 160kWe | technosphere | RER | 1 | p | lognormal, GSD² 1.3 | — | 8.4 | ██ | | | Steel, converter, unalloyed, at plant | technosphere | RER | 3000 | kg | lognormal, GSD² 1.2 | — | 7.8 | ██ | | | Assembly, module cogen unit 160kWe | technosphere | RER | 1 | p | lognormal, GSD² 1.3 | — | 4.3 | █ | | | Catalytic converter, SCR, 200 litre | technosphere | RER | 2.5 | p | lognormal, GSD² 2.5 | — | 4.0 | █ | | | Supply air input/spent air output cogen unit 160kWe | technosphere | RER | 1 | p | lognormal, GSD² 1.3 | — | 3.7 | █ | | | Catalytic converter, oxidation, 20 litre | technosphere | RER | 5 | p | lognormal, GSD² 2 | — | 3.6 | █ | | | Sound insulation cogen unit 160kWe | technosphere | RER | 1 | p | lognormal, GSD² 1.3 | — | 3.5 | █ | | | Construction work, cogen unit 160kWe | technosphere | RER | 1 | p | lognormal, GSD² 1.3 | — | 2.6 | █ | | | Light fuel oil, burned in industrial furnace 1MW, non-modulating | technosphere | CH | 16900 | MJ | lognormal, GSD² 1.6 | (3,3,3,3,4,3) | 1.7 | · | | | Natural gas, burned in industrial furnace 1MWth | technosphere | CH | 16900 | MJ | lognormal, GSD² 1.6 | (3,3,3,3,4,3) | 1.4 | · | | | Concrete, normal, at plant | technosphere | CH | 0.85 | m3 | lognormal, GSD² 1.2 | — | 0.2 | · | | | Polyethylene, HDPE, granulate, at plant | technosphere | RER | 70 | kg | lognormal, GSD² 1.2 | — | 0.2 | · | | | Alkyd paint, white, 60% in H2O, at plant | technosphere | RER | 40 | kg | lognormal, GSD² 1.2 | — | 0.1 | · | | | Electricity, medium voltage, production ENTSO-E, at grid | technosphere | ENTSO-E | 344 | kWh | lognormal, GSD² 1.6 | (3,3,3,3,4,3) | 0.1 | · | | | Transport, freight, lorry, fleet average | technosphere | RER | 300 | tkm | lognormal, GSD² 2.5 | — | 0.1 | · | | | Operation start, cogen unit 160kWe | technosphere | RER | 1 | p | lognormal, GSD² 1.3 | — | 0.0 | · | | | Transport, freight, rail | technosphere | RER | 600 | tkm | lognormal, GSD² 2.5 | — | 0.0 | · | | | Water | elementary | natural resource | 4.5 | m3 | lognormal, GSD² 3 | — | 0.0 | · | | | Water | elementary | water/Unknown | 4.275 | m3 | lognormal, GSD² 2.52 | — | 0.0 | · | | ==== Data quality ==== 3 of 22 direct exchanges carry a declared pedigree, 22 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.0 · completeness 3.0 · temporal 3.0 · geographical 3.0 · technological 4.0 · sample size 3.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Thomas Heck; data entry: Thomas Heck; validation (proof reading): Gerald Rebitzer | | extrapolations | see Geography/Text, see Technolgy Text | | sampling procedure | Operator and manufacturer information | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: passed; Other validation: none; | | time period comment | undefined | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **197.3** | 173.8 | 306.4 | 1.34 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **299.3** | 184.6 | 751.9 | 2.07 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **9.29e+04** | 8.194e+04 | 1.234e+05 | 1.23 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **21.31** | 18.97 | 34.33 | 1.36 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **9.322e+04** | 8.222e+04 | 1.238e+05 | 1.23 | | EF-particulate Matter | Impact on human health | disease incidence | **0.003038** | 0.002631 | 0.005279 | 1.44 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.329e+05** | 1.980e+05 | 5.925e+05 | 1.78 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **7261** | 6489 | 1.696e+04 | 1.84 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.402e+05** | 2.063e+05 | 6.033e+05 | 1.77 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **44.94** | 41.81 | 66.3 | 1.26 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **29.16** | 19.65 | 115 | 2.51 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **415.9** | 385.4 | 612.9 | 1.28 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.240e-05** | 2.847e-05 | 1.096e-04 | 1.97 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.784e-05** | 2.372e-05 | 4.839e-05 | 1.44 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **6.024e-05** | 5.646e-05 | 1.461e-04 | 1.62 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **0.00186** | 0.001437 | 0.006967 | 2.2 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.322e-04** | 7.205e-05 | 4.079e-04 | 2.37 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **0.001992** | 0.001585 | 0.007094 | 2.13 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **2.356e+04** | 8684 | 1.575e+05 | 4.37 | | Land use | Soil quality index | pt (soil quality index) | **2.848e+05** | 2.629e+05 | 5.124e+05 | 1.41 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **0.002205** | 0.001949 | 0.003593 | 1.37 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **275.1** | 241.1 | 448.3 | 1.38 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **1.258e+06** | 1.115e+06 | 1.805e+06 | 1.28 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.6162** | 0.4504 | 1.177 | 1.67 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **5432** | -2.503e+07 | 1.292e+07 | — | Climate change 9.322e+04 kg CO2 eq per p. Main contributors: Maintenance, cogen unit 160kWe 30 %; Control cabinet cogen unit 160kWe 17 %; Gas motor 206kW 12 %; Planning, cogen unit 160kWe 8 %; Steel, converter, unalloyed, at plant 8 %; Assembly, module cogen unit 160kWe 4 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Maintenance, cogen unit 160kWe 30 %; Control cabinet cogen unit 160kWe 17 %; Gas motor 206kW 12 %; Planning, cogen unit 160kWe 8 %; Steel, converter, unalloyed, at plant 8 %; Assembly, module cogen unit 160kWe 4 %. Most sensitive exchanges (Section 6.3): Maintenance, cogen unit 160kWe [RER] (-9.8 / +14.6 %); Gas motor 206kW [RER] (-4.7 / +7.9 %); Control cabinet cogen unit 160kWe [RER] (-3.8 / +4.9 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 197.3 | 896.2 | 0.220 | | Climate change-Biogenic | 299.3 | 299.3 | 1.000 | | Climate change-Fossil | 9.29e+04 | 9.29e+04 | 1.000 | | Climate change-Land use and land use change | 21.31 | 21.31 | 1.000 | | Climate change | 9.322e+04 | 9.322e+04 | 1.000 | | EF-particulate Matter | 0.003038 | 0.003038 | 1.000 | | Ecotoxicity, freshwater_inorganics | 2.329e+05 | 2.376e+05 | 0.980 | | Ecotoxicity, freshwater_organics | 7261 | 7222 | 1.005 | | Ecotoxicity, freshwater | 2.402e+05 | 2.429e+05 | 0.989 | | Eutrophication marine | 44.94 | 44.93 | 1.000 | | Eutrophication, freshwater | 29.16 | 29.16 | 1.000 | | Eutrophication, terrestrial | 415.9 | 449.7 | 0.925 | | Human toxicity, cancer_inorganics | 3.240e-05 | 3.201e-05 | 1.012 | | Human toxicity, cancer_organics | 2.784e-05 | 2.784e-05 | 1.000 | | Human toxicity, cancer | 6.024e-05 | 5.984e-05 | 1.007 | | Human toxicity, non-cancer_inorganics | 0.00186 | 0.001844 | 1.008 | | Human toxicity, non-cancer_organics | 1.322e-04 | 1.322e-04 | 1.000 | | Human toxicity, non-cancer | 0.001992 | 0.001977 | 1.008 | | Ionising radiation, human health | 2.356e+04 | 2.356e+04 | 1.000 | | Land use | 2.848e+05 | 2.376e+05 | 1.199 | | Ozone depletion | 0.002205 | 0.002205 | 1.000 | | Photochemical ozone formation - human health | 275.1 | 275.1 | 1.000 | | Resource use, fossils | 1.258e+06 | 1.259e+06 | 1.000 | | Resource use, minerals and metals | 0.6162 | 0.6123 | 1.006 | | Water use | 5432 | 6108 | 0.889 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 9.321e+04 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 1.855e+08 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Maintenance, cogen unit 160kWe [RER] | 1 p | ×0.672 / ×1.49 | lognormal, GSD² 1.5 | -9.8 / +14.6 | 17.3 (Climate change-Land use and land use change) | | Gas motor 206kW [RER] | 2.5 p | ×0.595 / ×1.68 | lognormal, GSD² 1.7 | -4.7 / +7.9 | 34.1 (Human toxicity, non-cancer_inorganics) | | Control cabinet cogen unit 160kWe [RER] | 1 p | ×0.773 / ×1.29 | lognormal, GSD² 1.3 | -3.8 / +4.9 | 5.4 (Ozone depletion) | | Catalytic converter, SCR, 200 litre [RER] | 2.5 p | ×0.407 / ×2.45 | lognormal, GSD² 2.5 | -2.4 / +5.8 | 15.0 (Resource use, minerals and metals) | | Catalytic converter, oxidation, 20 litre [RER] | 5 p | ×0.507 / ×1.97 | lognormal, GSD² 2 | -1.8 / +3.5 | 73.0 (Human toxicity, non-cancer_organics) | | Planning, cogen unit 160kWe [RER] | 1 p | ×0.773 / ×1.29 | lognormal, GSD² 1.3 | -1.9 / +2.5 | 3.6 (Climate change-Biogenic) | | Steel, converter, unalloyed, at plant [RER] | 3000 kg | ×0.836 / ×1.2 | lognormal, GSD² 1.2 | -1.3 / +1.5 | 3.2 (EF-particulate Matter) | | Assembly, module cogen unit 160kWe [RER] | 1 p | ×0.773 / ×1.29 | lognormal, GSD² 1.3 | -1.0 / +1.3 | 2.5 (Climate change-Biogenic) | | Supply air input/spent air output cogen unit 160kWe [RER] | 1 p | ×0.773 / ×1.29 | lognormal, GSD² 1.3 | -0.8 / +1.1 | 2.6 (Climate change-Land use and land use change) | | Sound insulation cogen unit 160kWe [RER] | 1 p | ×0.773 / ×1.29 | lognormal, GSD² 1.3 | -0.8 / +1.0 | 2.6 (Water use) | | Light fuel oil, burned in industrial furnace 1MW, non-modulating [CH] | 1.69e+04 MJ | ×0.631 / ×1.59 | lognormal, GSD² 1.6 | -0.6 / +1.0 | 1.0 (Climate change-Fossil) | | Construction work, cogen unit 160kWe [RER] | 1 p | ×0.773 / ×1.29 | lognormal, GSD² 1.3 | -0.6 / +0.8 | 1.7 (Climate change-Land use and land use change) | | Natural gas, burned in industrial furnace 1MWth [CH] | 1.69e+04 MJ | ×0.631 / ×1.59 | lognormal, GSD² 1.6 | -0.5 / +0.8 | 1.0 (Ecotoxicity, freshwater_inorganics) | | Transport, freight, lorry, fleet average [RER] | 300 tkm | ×0.407 / ×2.45 | lognormal, GSD² 2.5 | -0.0 / +0.1 | 1.5 (Climate change-Land use and land use change) | | Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] | 344 kWh | ×0.631 / ×1.59 | lognormal, GSD² 1.6 | -0.0 / +0.1 | 0.3 (Climate change-Biogenic) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 9.322e+04 kg CO2 eq per p (95 % interval 8.222e+04–1.238e+05). Dominant contributors: Maintenance, cogen unit 160kWe 30 %; Control cabinet cogen unit 160kWe 17 %; Gas motor 206kW 12 %; Planning, cogen unit 160kWe 8 %; Steel, converter, unalloyed, at plant 8 %; Assembly, module cogen unit 160kWe 4 %. Most sensitive: Maintenance, cogen unit 160kWe [RER] (-9.8 / +14.6 %); Gas motor 206kW [RER] (-4.7 / +7.9 %); Control cabinet cogen unit 160kWe [RER] (-3.8 / +4.9 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 7.2e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 22/22 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 9.322e+04 in [8.222e+04, 1.238e+05] | | time period declared | **PASS** | 1990-01/2000-12 | | geography is a known location code | **PASS** | RER | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Heck, T. (2007) Wärme-Kraft-Kopplung. Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0. Editors: Dones R.. Volume: 6. Swiss Centre for LCI, PSI. Dübendorf and Villigen, CH. Type: Measurement on site Source: CD-ROM First author: Heck, T. Year: 2007 Name of editors: Dones R. Title of anthology: Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0 Place of … — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].