====== Disposal, ventilation system, Bürohaus Fribourg — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:disposal_ventilation_system_b|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Disposal, ventilation system, Bürohaus Fribourg [CH], per 1 p. EF v3.1 climate change 5811 kg CO2 eq (Monte Carlo 95 % interval 5364–6982). Main contributors: Disposal, ventilation unit 13000 m3/h, w. rotary heat exchan… 16 %; Disposal, ventilation unit 6700 m3/h, w. circuit connected h… 13 %; Disposal, ventilation unit 13000 m3/h, w. cross plate heat e… 8 %; Disposal, ventilation unit 6700 m3/h, w. cross plate heat ex… 8 %; Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 8 %; Disposal, flexible duct, aluminum/PET, DN of 125 7 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Disposal, ventilation system, Bürohaus Fribourg | | Dataset UUID / graph id | ''%%5f51097c-7943-4c6c-ac11-f169541964d9%%'' / ''%%activity:disposal_ventilation_system_bürohaus_fribourg__ch%%'' | | Reference product, unit | Disposal, ventilation system, Bürohaus Fribourg, 1 p | | Location | CH — Specific to the technology mix encountered in sorting plants in Switzerland. | | Time period | 2014-01/2014-12 | | Category | waste management / building demolition | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Disposal of a ventilation system for an office building with offices, common rooms, kitchen, restaurant, auditorium and car park. The inventory is based on a building with a total heated gross floor area of 10161 m2 and a total nominal air flow of 54400 m3/h, total weight of the components: 15755 kg/Unit, building with a specific air flow rate of 5.4 m3/h per m2 heated gross floor area. Data from call of bid including components for air handling units, ducts including insulation, air valves, roof-hoods, dampers, fire dampers, silencers. The data represent a ductwork mainly made of galvanized steel and includes air handling units mainly with heat recovery. System with central air handling units. Building without ground heat exchanger.; UUID: 5f51097c-7943-4c6c-ac11-f169541964d9 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Disposal, ventilation system, Bürohaus Fribourg (CH). All results are given per unit of the reference flow. ==== System boundary ==== Transport to dismantling facilities, machines for handling in sorting plant, electricity demand for sorting plant, final disposal of waste material. Cut-off to recycling for metals. ==== Technology ==== Disposal to a sorting plant assumed. Metal pieces, copper in cables and electronic devices are recycled, plastic parts are incinerated, inert wastes (e.g. rock wool) are landfilled. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Disposal, ventilation unit 13000 m3/h, w. rotary heat exchanger | technosphere | CH | 1.1 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 15.8 | ███ | | | Disposal, ventilation unit 6700 m3/h, w. circuit connected heat exchanger | technosphere | CH | 1.567 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 13.4 | ███ | | | Disposal, ventilation unit 13000 m3/h, w. cross plate heat excanger | technosphere | CH | 0.546 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 8.3 | ██ | | | Disposal, ventilation unit 6700 m3/h, w. cross plate heat excanger | technosphere | CH | 0.896 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 8.1 | ██ | | | Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger | technosphere | CH | 1.486 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 7.6 | ██ | | | Disposal, flexible duct, aluminum/PET, DN of 125 | technosphere | CH | 1434.4 | m | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 6.7 | █ | | | Disposal, ventilation system, Bürohaus Fribourg, various components | technosphere | CH | 1 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 6.0 | █ | | | Disposal, ventilator unit 13000 m3/h, modular, w. filter, without silencer | technosphere | CH | 0.769 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 4.8 | █ | | | Disposal, ventilation duct, steel, zinc coated, s= 0.75mm | technosphere | CH | 1402.1 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 4.4 | █ | | | Disposal, ventilation duct, steel, zinc coated, s= 0.87mm | technosphere | CH | 1102.6 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 3.6 | █ | | | Disposal, silencer for ventilator unit 13000 m3/h, modular | technosphere | CH | 8.122 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 3.5 | █ | | | Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm | technosphere | CH | 563.78 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 3.2 | █ | | | Disposal, silencer for ventilator unit 6700 m3/h, modular, Device | technosphere | CH | 9.852 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 3.1 | █ | | | Disposal, ventilation duct, steel, zinc coated, s= 1.0mm | technosphere | CH | 791.4 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 2.6 | █ | | | Disposal, EI 60 fire insulation, 70mm, 120kg/m3, reinforced alumium foil | technosphere | CH | 364 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.8 | · | | | Disposal, ventilation duct, steel, zinc coated, s= 0.62mm | technosphere | CH | 548.52 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.7 | · | | | Disposal, silencer for ventilator unit 3500 m3/h, modular | technosphere | CH | 5.944 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 1.3 | · | | | Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil | technosphere | CH | 374 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.0 | · | | | Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm | technosphere | CH | 181.73 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.0 | · | | | Disposal, ventilation system, Bürohaus Fribourg, special components | technosphere | CH | 1 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.0 | · | | | Disposal, ventilation duct, steel, zinc coated, s= 1.25mm | technosphere | CH | 210.68 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.7 | · | | | Disposal, spiral-seam duct, stainless steel, s= 0.8mm | technosphere | CH | 32.044 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.2 | · | | | Disposal, spiral-seam duct, steel, zinc coated, s= 0.8mm | technosphere | CH | 15.368 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · | | | Disposal, spiral-seam duct, stainless steel, s= 0.5mm | technosphere | CH | 12.818 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · | | | Disposal, ventilation duct, stainless steel, s= 1.0mm | technosphere | CH | 3.4234 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | | | Disposal, ventilation duct, stainless steel, s= 0.87mm | technosphere | CH | 1.68 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | | | Disposal, ventilation duct, stainless steel, s= 0.62mm | technosphere | CH | 0.175 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | | ==== Data quality ==== 27 of 27 direct exchanges carry a declared pedigree, 27 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.33 · completeness 4.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 5.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU) | | extrapolations | none | | sampling procedure | Waste-specific calculation based on production input data | | production volume | na | | uncertainty adjustments | none | | time period comment | Amount of material investigated in 2013. Disposal technology mix as used in late 1990ies | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **1.48** | 1.265 | 3.513 | 1.69 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.018** | 0.8104 | 2.086 | 1.6 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **5810** | 5363 | 6980 | 1.15 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.1709** | 0.1483 | 0.2668 | 1.35 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **5811** | 5364 | 6982 | 1.15 | | EF-particulate Matter | Impact on human health | disease incidence | **6.883e-05** | 5.119e-05 | 1.334e-04 | 1.62 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.43e+04** | 1.957e+04 | 3.869e+04 | 1.42 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **74.55** | 65.5 | 146.5 | 1.54 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.437e+04** | 1.965e+04 | 3.877e+04 | 1.42 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **1.899** | 1.448 | 5.088 | 1.86 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **0.4775** | 0.1284 | 12.69 | 11.2 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **12.63** | 9.12 | 37.43 | 2.07 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.933e-07** | 2.821e-07 | 1.263e-06 | 2.11 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **8.440e-08** | 8.021e-08 | 1.395e-07 | 1.32 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **3.777e-07** | 3.828e-07 | 1.368e-06 | 1.89 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.835e-05** | 1.794e-05 | 6.980e-05 | 2.03 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.837e-07** | 5.082e-07 | 8.841e-07 | 1.32 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.894e-05** | 1.852e-05 | 7.061e-05 | 2 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **170.2** | 64.95 | 1040 | 4.17 | | Land use | Soil quality index | pt (soil quality index) | **5769** | 2525 | 1.093e+04 | — | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **1.871e-05** | 1.704e-05 | 3.443e-05 | 1.42 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **4.709** | 3.639 | 12.57 | 1.88 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **8201** | 7502 | 1.596e+04 | 1.45 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.001166** | 0.001017 | 0.002342 | 1.54 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **801.8** | -7.109e+04 | 3.854e+04 | — | Climate change 5811 kg CO2 eq per p. Main contributors: Disposal, ventilation unit 13000 m3/h, w. rotary heat exchan… 16 %; Disposal, ventilation unit 6700 m3/h, w. circuit connected h… 13 %; Disposal, ventilation unit 13000 m3/h, w. cross plate heat e… 8 %; Disposal, ventilation unit 6700 m3/h, w. cross plate heat ex… 8 %; Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 8 %; Disposal, flexible duct, aluminum/PET, DN of 125 7 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Disposal, ventilation unit 13000 m3/h, w. rotary heat exchan… 16 %; Disposal, ventilation unit 6700 m3/h, w. circuit connected h… 13 %; Disposal, ventilation unit 13000 m3/h, w. cross plate heat e… 8 %; Disposal, ventilation unit 6700 m3/h, w. cross plate heat ex… 8 %; Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 8 %; Disposal, flexible duct, aluminum/PET, DN of 125 7 %. Most sensitive exchanges (Section 6.3): Disposal, ventilation unit 13000 m3/h, w. rotary heat exchanger [CH] (-3.2 / +4.0 %); Disposal, ventilation unit 6700 m3/h, w. circuit connected heat exchanger [CH] (-2.7 / +3.4 %); Disposal, ventilation unit 13000 m3/h, w. cross plate heat excanger [CH] (-1.7 / +2.1 %). ==== Independent recalculation ==== The publisher publishes no LCIA result for this dataset; the closure check of Section 7 is the recalculation test. ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Disposal, ventilation unit 13000 m3/h, w. rotary heat exchanger [CH] | 1.1 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -3.2 / +4.0 | 6.2 (Water use) | | Disposal, ventilation unit 6700 m3/h, w. circuit connected heat exchanger [CH] | 1.567 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -2.7 / +3.4 | 4.7 (Water use) | | Disposal, ventilation unit 13000 m3/h, w. cross plate heat excanger [CH] | 0.546 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -1.7 / +2.1 | 3.2 (Water use) | | Disposal, ventilation unit 6700 m3/h, w. cross plate heat excanger [CH] | 0.896 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -1.6 / +2.1 | 2.8 (Water use) | | Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger [CH] | 1.486 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -1.5 / +1.9 | 2.4 (Water use) | | Disposal, flexible duct, aluminum/PET, DN of 125 [CH] | 1434 m | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -1.3 / +1.6 | 1.6 (Climate change-Fossil) | | Disposal, ventilation system, Bürohaus Fribourg, various components [CH] | 1 p | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -1.1 / +1.4 | 5.0 (EF-particulate Matter) | | Disposal, ventilator unit 13000 m3/h, modular, w. filter, without silencer [CH] | 0.769 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -1.0 / +1.2 | 2.1 (Water use) | | Disposal, ventilation duct, steel, zinc coated, s= 0.75mm [CH] | 1402 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.8 / +1.0 | 2.9 (Ionising radiation, human health) | | Disposal, silencer for ventilator unit 13000 m3/h, modular [CH] | 8.122 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.7 / +0.9 | 2.0 (Eutrophication marine) | | Disposal, ventilation duct, steel, zinc coated, s= 0.87mm [CH] | 1103 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.7 / +0.8 | 2.6 (Ionising radiation, human health) | | Disposal, silencer for ventilator unit 6700 m3/h, modular, Device [CH] | 9.852 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.6 / +0.8 | 1.7 (Eutrophication marine) | | Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm [CH] | 563.8 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.6 / +0.8 | 0.8 (Climate change-Fossil) | | Disposal, ventilation duct, steel, zinc coated, s= 1.0mm [CH] | 791.4 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.5 / +0.6 | 2.2 (Ionising radiation, human health) | | Disposal, EI 60 fire insulation, 70mm, 120kg/m3, reinforced alumium foil [CH] | 364 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.3 / +0.4 | 10.8 (Eutrophication, freshwater) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 5811 kg CO2 eq per p (95 % interval 5364–6982). Dominant contributors: Disposal, ventilation unit 13000 m3/h, w. rotary heat exchan… 16 %; Disposal, ventilation unit 6700 m3/h, w. circuit connected h… 13 %; Disposal, ventilation unit 13000 m3/h, w. cross plate heat e… 8 %; Disposal, ventilation unit 6700 m3/h, w. cross plate heat ex… 8 %; Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 8 %; Disposal, flexible duct, aluminum/PET, DN of 125 7 %. Most sensitive: Disposal, ventilation unit 13000 m3/h, w. rotary heat exchanger [CH] (-3.2 / +4.0 %); Disposal, ventilation unit 6700 m3/h, w. circuit connected heat exchanger [CH] (-2.7 / +3.4 %); Disposal, ventilation unit 13000 m3/h, w. cross plate heat excanger [CH] (-1.7 / +2.1 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.6e-16 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 27/27 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 5811 in [5364, 6982] | | time period declared | **PASS** | 2014-01/2014-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].