====== xxx Electricity, production mix CH, Bereich 4 — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:xxx_electricity_production_mix_ch_bereich_4__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset xxx Electricity, production mix CH, Bereich 4 [CH], per 1 kWh. EF v3.1 climate change 0.006084 kg CO2 eq (Monte Carlo 95 % interval -1.821e-04–0.0131). Main contributors: Disposal, municipal solid waste, 22.9% water, to municipal i… -227 %; Electricity, at cogen 300kWth, natural gas, allocation exerg… 94 %; Electricity, hydropower, at pumped storage power plant 76 %; Electricity, nuclear, at power plant pressure water reactor 46 %; Electricity, nuclear, at power plant boiling water reactor 40 %; Electricity, hydropower, at reservoir power plant 39 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | xxx Electricity, production mix CH, Bereich 4 | | Dataset UUID / graph id | ''%%5f6b057b-7759-319d-bc12-b757bd795c59%%'' / ''%%activity:xxx_electricity_production_mix_ch_bereich_4__ch%%'' | | Reference product, unit | xxx Electricity, production mix CH, Bereich 4, 1 kWh | | Location | CH — Data apply to public and self producers in Switzerland. | | Time period | 9999-01/9999-12 | | Category | electricity / notMaintained | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Electricity domestic net production shares are based on annual averages for the year 2018.; UUID: 5f6b057b-7759-319d-bc12-b757bd795c59 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kWh** of xxx Electricity, production mix CH, Bereich 4 (CH). All results are given per unit of the reference flow. ==== System boundary ==== Included are the shares of domestic electricity production by technology at the busbar. Not included are transformation, transport or distribution losses. ==== Technology ==== No technology description is provided because the dataset just describes the power plant portfolio of the respective country using current average technology per energy carrier. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Disposal, municipal solid waste, 22.9% water, to municipal incineration | technosphere | CH | -0.026509 | kg | lognormal, GSD² 1.07 | — | -227.2 | ████████████████████ | | | Electricity, at cogen 300kWth, natural gas, allocation exergy | technosphere | CH | 0.0092411 | kWh | lognormal, GSD² 1.07 | — | 94.0 | ███████████████████ | | | Electricity, hydropower, at pumped storage power plant | technosphere | CH | 0.037997 | kWh | lognormal, GSD² 1.07 | — | 75.8 | ███████████████ | | | Electricity, nuclear, at power plant pressure water reactor | technosphere | CH | 0.20185 | kWh | lognormal, GSD² 1.07 | — | 45.8 | █████████ | | | Electricity, nuclear, at power plant boiling water reactor | technosphere | CH | 0.15912 | kWh | lognormal, GSD² 1.07 | — | 40.4 | ████████ | | | Electricity, hydropower, at reservoir power plant | technosphere | CH | 0.2654 | kWh | lognormal, GSD² 1.07 | — | 38.6 | ████████ | | | Disposal, biowaste, 60% H2O, to municipal incineration, allocation price | technosphere | CH | -0.026977 | kg | lognormal, GSD² 1.07 | — | -17.4 | ███ | | | Electricity, at cogen 300kWth, biomethane, allocation exergy | technosphere | CH | 0.0031523 | kWh | lognormal, GSD² 1.07 | — | 16.5 | ███ | | | Electricity, production mix photovoltaic, at plant | technosphere | CH | 0.028717 | kWh | lognormal, GSD² 1.07 | — | 13.9 | ███ | | | Electricity, hydropower, at run-of-river power plant | technosphere | CH | 0.19972 | kWh | lognormal, GSD² 1.07 | — | 11.9 | ██ | | | Disposal, paper, 11.2% water, to municipal incineration | technosphere | CH | -0.014961 | kg | lognormal, GSD² 1.07 | — | -10.1 | ██ | | | Electricity, at cogen with biogas engine, agricultural covered, alloc. exergy | technosphere | CH | 0.0020478 | kWh | lognormal, GSD² 1.07 | — | 5.2 | █ | | | Electricity, at cogen 1MWth, wood chips, allocation exergy | technosphere | CH | 0.0044727 | kWh | lognormal, GSD² 1.07 | — | 4.6 | █ | | | Electricity, hydropower, at small hydropower plant | technosphere | CH | 0.050271 | kWh | lognormal, GSD² 1.07 | — | 3.9 | █ | | | Electricity, at cogen 300kWth, diesel, allocation exergy | technosphere | CH | 2.9424e-04 | kWh | lognormal, GSD² 1.07 | — | 3.6 | █ | | | Electricity, at wind farm | technosphere | CH | 0.0018009 | kWh | lognormal, GSD² 1.07 | — | 0.5 | · | | | Electricity, at wind farm | technosphere | RER | 4.4357e-08 | kWh | lognormal, GSD² 1.07 | — | 0.0 | · | | ==== Data quality ==== 0 of 17 direct exchanges carry a declared pedigree, 17 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Philippe Stolz (TREEZE); data entry: Luana Krebs (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | | | sampling procedure | Statistical data | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: automatic validation in Excel; Other validation: G:\Projekte laufend\726 Umweltbilanz Strommix Schweiz 2018\EcoSpold[726-Strommix-Schweiz-2018-v0.5.xlsx]X-Process; | | time period comment | Time period of statistics used. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **4.921e-05** | 4.143e-05 | 6.550e-05 | 1.28 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **9.413e-04** | 7.342e-04 | 0.001333 | 1.36 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.004706** | -0.001492 | 0.01163 | — | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **4.367e-04** | 3.277e-04 | 6.050e-04 | 1.37 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.006084** | -1.821e-04 | 0.0131 | — | | EF-particulate Matter | Impact on human health | disease incidence | **3.144e-09** | 2.211e-09 | 5.804e-09 | 1.63 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **-0.009579** | -0.08688 | 0.06767 | — | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.001267** | 0.00115 | 0.002803 | 1.67 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **-0.008312** | -0.08446 | 0.07111 | — | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **1.635e-05** | -1.162e-06 | 2.496e-05 | — | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **6.382e-06** | -1.576e-04 | 2.728e-05 | — | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **1.356e-04** | -1.567e-05 | 2.037e-04 | — | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **-3.478e-12** | -2.466e-11 | 7.840e-13 | — | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.379e-11** | 9.950e-12 | 2.152e-11 | 1.49 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.032e-11** | -1.009e-11 | 1.874e-11 | — | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **-9.990e-11** | -1.329e-09 | 1.579e-10 | — | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **9.928e-12** | 9.054e-12 | 1.700e-11 | 1.37 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **-8.997e-11** | -1.316e-09 | 1.713e-10 | — | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.618** | 0.2326 | 3.382 | 4.12 | | Land use | Soil quality index | pt (soil quality index) | **0.4512** | 0.2884 | 0.7815 | 1.67 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **1.862e-08** | 1.537e-08 | 2.283e-08 | 1.22 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **3.794e-05** | -7.481e-06 | 6.457e-05 | — | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **5.464** | 4.695 | 7.101 | 1.23 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **1.138e-07** | 1.077e-07 | 2.102e-07 | 1.42 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.05044** | -23.82 | 12.06 | — | Climate change 0.006084 kg CO2 eq per kWh. Main contributors: Disposal, municipal solid waste, 22.9% water, to municipal i… -227 %; Electricity, at cogen 300kWth, natural gas, allocation exerg… 94 %; Electricity, hydropower, at pumped storage power plant 76 %; Electricity, nuclear, at power plant pressure water reactor 46 %; Electricity, nuclear, at power plant boiling water reactor 40 %; Electricity, hydropower, at reservoir power plant 39 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Disposal, municipal solid waste, 22.9% water, to municipal i… -227 %; Electricity, at cogen 300kWth, natural gas, allocation exerg… 94 %; Electricity, hydropower, at pumped storage power plant 76 %; Electricity, nuclear, at power plant pressure water reactor 46 %; Electricity, nuclear, at power plant boiling water reactor 40 %; Electricity, hydropower, at reservoir power plant 39 %. Most sensitive exchanges (Section 6.3): Disposal, municipal solid waste, 22.9% water, to municipal incineration [CH] (+14.9 / -15.9 %); Electricity, at cogen 300kWth, natural gas, allocation exergy [CH] (-6.1 / +6.6 %); Electricity, hydropower, at pumped storage power plant [CH] (-5.0 / +5.3 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh: ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 4.921e-05 | 6.140e-05 | 0.802 | | Climate change-Biogenic | 9.413e-04 | 9.413e-04 | 1.000 | | Climate change-Fossil | 0.004706 | 0.004706 | 1.000 | | Climate change-Land use and land use change | 4.367e-04 | 4.367e-04 | 1.000 | | Climate change | 0.006084 | 0.006084 | 1.000 | | EF-particulate Matter | 3.144e-09 | 3.144e-09 | 1.000 | | Ecotoxicity, freshwater_inorganics | -0.009579 | -0.003933 | 2.436 | | Ecotoxicity, freshwater_organics | 0.001267 | 0.001196 | 1.060 | | Ecotoxicity, freshwater | -0.008312 | -0.002778 | 2.992 | | Eutrophication marine | 1.635e-05 | 1.580e-05 | 1.035 | | Eutrophication, freshwater | 6.382e-06 | 6.382e-06 | 1.000 | | Eutrophication, terrestrial | 1.356e-04 | 1.254e-04 | 1.081 | | Human toxicity, cancer_inorganics | -3.478e-12 | -3.833e-12 | 0.907 | | Human toxicity, cancer_organics | 1.379e-11 | 1.379e-11 | 1.000 | | Human toxicity, cancer | 1.032e-11 | 9.962e-12 | 1.036 | | Human toxicity, non-cancer_inorganics | -9.990e-11 | -1.238e-10 | 0.807 | | Human toxicity, non-cancer_organics | 9.928e-12 | 9.921e-12 | 1.001 | | Human toxicity, non-cancer | -8.997e-11 | -1.138e-10 | 0.790 | | Ionising radiation, human health | 0.618 | 0.618 | 1.000 | | Land use | 0.4512 | 0.3595 | 1.255 | | Ozone depletion | 1.862e-08 | 1.862e-08 | 1.000 | | Photochemical ozone formation - human health | 3.794e-05 | 3.794e-05 | 1.000 | | Resource use, fossils | 5.464 | 5.464 | 1.000 | | Resource use, minerals and metals | 1.138e-07 | 1.128e-07 | 1.009 | | Water use | 0.05044 | 0.05533 | 0.912 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.006082 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 229.9 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Disposal, municipal solid waste, 22.9% water, to municipal incineration [CH] | -0.02651 kg | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | +14.9 / -15.9 | 46.8 (Ecotoxicity, freshwater) | | Electricity, at cogen 300kWth, natural gas, allocation exergy [CH] | 0.009241 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -6.1 / +6.6 | 15.2 (Ecotoxicity, freshwater) | | Electricity, hydropower, at pumped storage power plant [CH] | 0.038 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -5.0 / +5.3 | 11.5 (Ecotoxicity, freshwater) | | Electricity, nuclear, at power plant pressure water reactor [CH] | 0.2019 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -3.0 / +3.2 | 13.8 (Ecotoxicity, freshwater) | | Electricity, nuclear, at power plant boiling water reactor [CH] | 0.1591 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -2.6 / +2.8 | 11.1 (Ecotoxicity, freshwater) | | Electricity, hydropower, at reservoir power plant [CH] | 0.2654 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -2.5 / +2.7 | 5.8 (Climate change-Land use and land use change) | | Disposal, biowaste, 60% H2O, to municipal incineration, allocation price [CH] | -0.02698 kg | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | +1.1 / -1.2 | 20.4 (Ecotoxicity, freshwater) | | Electricity, at cogen 300kWth, biomethane, allocation exergy [CH] | 0.003152 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -1.1 / +1.2 | 4.4 (Climate change-Biogenic) | | Electricity, production mix photovoltaic, at plant [CH] | 0.02872 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.9 / +1.0 | 4.7 (Resource use, minerals and metals) | | Electricity, hydropower, at run-of-river power plant [CH] | 0.1997 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.8 / +0.8 | 1.0 (Human toxicity, non-cancer) | | Disposal, paper, 11.2% water, to municipal incineration [CH] | -0.01496 kg | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | +0.7 / -0.7 | 6.6 (Ecotoxicity, freshwater) | | Electricity, at cogen with biogas engine, agricultural covered, alloc. exergy [CH] | 0.002048 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.3 / +0.4 | 3.0 (Ecotoxicity, freshwater) | | Electricity, at cogen 1MWth, wood chips, allocation exergy [CH] | 0.004473 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.3 / +0.3 | 5.5 (Land use) | | Electricity, hydropower, at small hydropower plant [CH] | 0.05027 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.3 / +0.3 | 0.7 (Human toxicity, non-cancer) | | Electricity, at cogen 300kWth, diesel, allocation exergy [CH] | 2.942e-04 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.2 / +0.3 | 2.5 (Human toxicity, cancer) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.006084 kg CO2 eq per kWh (95 % interval -1.821e-04–0.0131). Dominant contributors: Disposal, municipal solid waste, 22.9% water, to municipal i… -227 %; Electricity, at cogen 300kWth, natural gas, allocation exerg… 94 %; Electricity, hydropower, at pumped storage power plant 76 %; Electricity, nuclear, at power plant pressure water reactor 46 %; Electricity, nuclear, at power plant boiling water reactor 40 %; Electricity, hydropower, at reservoir power plant 39 %. Most sensitive: Disposal, municipal solid waste, 22.9% water, to municipal incineration [CH] (+14.9 / -15.9 %); Electricity, at cogen 300kWth, natural gas, allocation exergy [CH] (-6.1 / +6.6 %); Electricity, hydropower, at pumped storage power plant [CH] (-5.0 / +5.3 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kWh | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.3e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 15/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 17/17 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.006084 in [-1.821e-04, 0.0131] | | time period declared | **PASS** | 9999-01/9999-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Krebs L., Stolz P., Frischknecht R. (2020) Umweltbilanz Strommix Schweiz 2018. Project reports. Volume: 723. treeze Ltd.. Uster, CH. Type: Separate publication First author: Krebs L. Other authors: Stolz P., Frischknecht R. Year: 2020 Title of anthology: Project reports Place of publication: Uster, CH Publisher: treeze Ltd. Volume No: 723 — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].