====== Electricity, high voltage,PV, slanted roof, multi-Si, panel — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:electricity_high_voltage_pv_slanted_roof_multi_si_panel__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity, high voltage,PV, slanted roof, multi-Si, panel [CH], per 1 kWh. EF v3.1 climate change 0.03759 kg CO2 eq (Monte Carlo 95 % interval 0.02552–0.09258). Main contributors: Electricity, PV, at 3kWp slanted-roof, multi-Si, panel, moun… 93 %; Nitrous Oxide 4 %; Transmission network, electricity, high voltage 3 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Electricity, high voltage,PV, slanted roof, multi-Si, panel | | Dataset UUID / graph id | ''%%67792dff-f137-3df6-bc2b-d4648c5def7a%%'' / ''%%activity:electricity_high_voltage_pv_slanted_roof_multi_si_panel__ch%%'' | | Reference product, unit | Electricity, high voltage,PV, slanted roof, multi-Si, panel, 1 kWh | | Location | CH — Data apply to public and self producers. Geographical classification according to IEA. Ozone- and NO2-emission factors are based on published measurements made in various countries. Assumptions for transmission network, losses and emissions are based on Swiss data. | | Time period | 2005-01/2005-12 | | Category | energy supply, kbob recommendation / electricity, delivered via network | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== This dataset describes the transmission of high voltage electricity.; UUID: 67792dff-f137-3df6-bc2b-d4648c5def7a This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kWh** of Electricity, high voltage,PV, slanted roof, multi-Si, panel (CH). All results are given per unit of the reference flow. ==== System boundary ==== Included are the electricity production in 0, the transmission network and direct emissions to air (ozone and N2O). Electricity losses are accounted for. ==== Technology ==== Average technology used to transmit and distribute electricity. Includes underground and overhead lines. Electricity production according to related datasets ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electricity, PV, at 3kWp slanted-roof, multi-Si, panel, mounted | technosphere | CH | 1.033 | kWh | lognormal, GSD² 1.24 | (3,1,1,1,3,1) | 93.5 | ███████████████████ | | | Transmission network, electricity, high voltage | technosphere | CH | 6.8199e-09 | km | lognormal, GSD² 3.16 | (3,1,4,5,3,5) | 2.9 | █ | | | Nitrous Oxide | elementary | air/Unknown | 5.0000e-06 | kg | lognormal, GSD² 1.5 | — | 3.6 | █ | | | Waste Heat | elementary | soil/Unknown | 0.0059435 | MJ | lognormal, GSD² 1.32 | (4,1,3,1,1,5) | 0.0 | · | | | Waste Heat | elementary | air/Unknown | 0.11293 | MJ | lognormal, GSD² 1.32 | (4,1,3,1,1,5) | 0.0 | · | | | Ozone | elementary | air/Unknown | 4.5000e-06 | kg | lognormal, GSD² 1.5 | — | 0.0 | · | | ==== Data quality ==== 4 of 6 direct exchanges carry a declared pedigree, 6 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.5 · completeness 1.0 · temporal 2.75 · geographical 2.0 · technological 2.0 · sample size 4.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: René Itten (ZHAW); data entry: René Itten (ZHAW); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | | | sampling procedure | statistics | | production volume | total electricity in Switzerland: 60 TWh | | uncertainty adjustments | none | | validation details | Proof reading validation: 08.05.2014; Other validation: G:\Projekte laufend\388 Aktualisierung PEF Energie\EcoSpold[388_60_electricity_from_grid-v0.3.xlsx]X-Process; | | time period comment | Time of publications. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **1.780e-04** | 1.298e-04 | 3.780e-04 | 1.76 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.602e-04** | 7.903e-05 | 6.166e-04 | 2.86 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.03741** | 0.02537 | 0.09195 | 1.94 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2.234e-05** | 1.552e-05 | 4.976e-05 | 1.85 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.03759** | 0.02552 | 0.09258 | 1.94 | | EF-particulate Matter | Impact on human health | disease incidence | **1.388e-09** | 1.052e-09 | 7.101e-09 | 2.68 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.2203** | 0.1603 | 0.6964 | 2.13 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.004656** | 0.003559 | 0.01255 | 1.91 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.2249** | 0.1639 | 0.7051 | 2.12 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **4.353e-05** | 2.957e-05 | 1.103e-04 | 1.95 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **5.187e-05** | 3.246e-05 | 3.270e-04 | 3.29 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **3.505e-04** | 2.539e-04 | 8.184e-04 | 1.86 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.068e-11** | 1.848e-11 | 7.162e-11 | 2 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **9.717e-12** | 6.677e-12 | 2.846e-11 | 2.1 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **3.040e-11** | 2.660e-11 | 9.415e-11 | 1.92 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.360e-09** | 1.216e-09 | 4.361e-09 | 1.95 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **6.437e-11** | 4.334e-11 | 1.407e-10 | 1.84 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.425e-09** | 1.286e-09 | 4.455e-09 | 1.92 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.009215** | 0.002784 | 0.07434 | 5.39 | | Land use | Soil quality index | pt (soil quality index) | **0.2711** | 0.1825 | 0.7618 | 2.06 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **1.378e-09** | 9.803e-10 | 3.649e-09 | 1.96 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **1.202e-04** | 8.902e-05 | 2.733e-04 | 1.81 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.4781** | 0.3195 | 1.276 | 2.01 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **5.820e-06** | 3.943e-06 | 9.796e-06 | 1.6 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.01111** | -10.25 | 5.033 | — | Climate change 0.03759 kg CO2 eq per kWh. Main contributors: Electricity, PV, at 3kWp slanted-roof, multi-Si, panel, moun… 93 %; Nitrous Oxide 4 %; Transmission network, electricity, high voltage 3 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electricity, PV, at 3kWp slanted-roof, multi-Si, panel, moun… 93 %; Nitrous Oxide 4 %; Transmission network, electricity, high voltage 3 %. Most sensitive exchanges (Section 6.3): Electricity, PV, at 3kWp slanted-roof, multi-Si, panel, mounted [CH] (-17.5 / +21.5 %); Transmission network, electricity, high voltage [CH] (-1.9 / +6.0 %); Nitrous Oxide [air/Unknown] (-1.2 / +1.8 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh: ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 1.780e-04 | 1.884e-04 | 0.945 | | Climate change-Biogenic | 1.602e-04 | 1.602e-04 | 1.000 | | Climate change-Fossil | 0.03741 | 0.03741 | 1.000 | | Climate change-Land use and land use change | 2.234e-05 | 2.234e-05 | 1.000 | | Climate change | 0.03759 | 0.03759 | 1.000 | | EF-particulate Matter | 1.388e-09 | 1.388e-09 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.2203 | 0.2271 | 0.970 | | Ecotoxicity, freshwater_organics | 0.004656 | 0.003946 | 1.180 | | Ecotoxicity, freshwater | 0.2249 | 0.2295 | 0.980 | | Eutrophication marine | 4.353e-05 | 4.353e-05 | 1.000 | | Eutrophication, freshwater | 5.187e-05 | 5.187e-05 | 1.000 | | Eutrophication, terrestrial | 3.505e-04 | 3.642e-04 | 0.962 | | Human toxicity, cancer_inorganics | 2.068e-11 | 2.057e-11 | 1.005 | | Human toxicity, cancer_organics | 9.717e-12 | 9.716e-12 | 1.000 | | Human toxicity, cancer | 3.040e-11 | 3.029e-11 | 1.004 | | Human toxicity, non-cancer_inorganics | 1.360e-09 | 1.353e-09 | 1.006 | | Human toxicity, non-cancer_organics | 6.437e-11 | 6.434e-11 | 1.000 | | Human toxicity, non-cancer | 1.425e-09 | 1.417e-09 | 1.005 | | Ionising radiation, human health | 0.009215 | 0.009215 | 1.000 | | Land use | 0.2711 | 0.2209 | 1.228 | | Ozone depletion | 1.378e-09 | 1.378e-09 | 1.000 | | Photochemical ozone formation - human health | 1.202e-04 | 1.202e-04 | 1.000 | | Resource use, fossils | 0.4781 | 0.4782 | 1.000 | | Resource use, minerals and metals | 5.820e-06 | 5.802e-06 | 1.003 | | Water use | 0.01111 | 0.01129 | 0.984 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.03755 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 105.5 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Electricity, PV, at 3kWp slanted-roof, multi-Si, panel, mounted [CH] | 1.033 kWh | ×0.813 / ×1.23 | lognormal, GSD² 1.24 | -17.5 / +21.5 | 22.9 (Resource use, minerals and metals) | | Transmission network, electricity, high voltage [CH] | 6.820e-09 km | ×0.324 / ×3.09 | lognormal, GSD² 3.16 | -1.9 / +6.0 | 9.7 (EF-particulate Matter) | | Nitrous Oxide [air/Unknown] | 5.000e-06 kg | ×0.672 / ×1.49 | lognormal, GSD² 1.5 | -1.2 / +1.8 | 1.8 (Climate change-Fossil) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.03759 kg CO2 eq per kWh (95 % interval 0.02552–0.09258). Dominant contributors: Electricity, PV, at 3kWp slanted-roof, multi-Si, panel, moun… 93 %; Nitrous Oxide 4 %; Transmission network, electricity, high voltage 3 %. Most sensitive: Electricity, PV, at 3kWp slanted-roof, multi-Si, panel, mounted [CH] (-17.5 / +21.5 %); Transmission network, electricity, high voltage [CH] (-1.9 / +6.0 %); Nitrous Oxide [air/Unknown] (-1.2 / +1.8 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kWh | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.0e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 22/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 6/6 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.03759 in [0.02552, 0.09258] | | time period declared | **PASS** | 2005-01/2005-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Frischknecht R., Itten R., Tuchschmid M., (2010) Primärenergiefaktoren von Energiesystemen. Project reports. Volume: 387. ESU-services Ltd.. Uster, CH. — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].