====== Electricity, hydropower, at pumped storage plant, ENTSO, winter 2018 — DE ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:electricity_hydropower_at_pumped_storage_plant_entso_winter_2018__de|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity, hydropower, at pumped storage plant, ENTSO, winter 2018 [DE], per 1 kWh. EF v3.1 climate change 0.6318 kg CO2 eq (Monte Carlo 95 % interval 0.4016–1.092). Main contributors: Electricity, high voltage, operation storage pumps, ENTSO, w… 99 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Electricity, hydropower, at pumped storage plant, ENTSO, winter 2018 | | Dataset UUID / graph id | ''%%69261fe8-77e9-347a-a623-4e6584ebb70f%%'' / ''%%activity:electricity_hydropower_at_pumped_storage_plant_entso_winter_2018__de%%'' | | Reference product, unit | Electricity, hydropower, at pumped storage plant, ENTSO, winter 2018, 1 kWh | | Location | DE — Germany | | Time period | 2018-01/2018-12 | | Category | electricity by fuel / hydro\power plants | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== The electricity used to run the pump storage power plant is modelled by a specific electricity mix used for the operation of storage pumps in Germany in winter 2018.; UUID: 69261fe8-77e9-347a-a623-4e6584ebb70f This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kWh** of Electricity, hydropower, at pumped storage plant, ENTSO, winter 2018 (DE). All results are given per unit of the reference flow. ==== System boundary ==== This dataset includes the shares of different technologies of the electricity mix used for the operation of storage pumps in Germany. ==== Technology ==== Average technology ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electricity, high voltage, operation storage pumps, ENTSO, winter 2018, at grid | technosphere | DE | 1.25 | kWh | lognormal, GSD² 1.57 | — | 99.2 | ████████████████████ | | | Reservoir hydropower plant | technosphere | CH | 3.3470e-11 | p | lognormal, GSD² 3.27 | — | 0.6 | · | | | Sulphur hexafluoride, liquid, at plant | technosphere | RER | 3.4000e-10 | kg | lognormal, GSD² 1.69 | — | 0.0 | · | | | Lubricating oil, at plant | technosphere | RER | 3.2440e-08 | kg | lognormal, GSD² 1.69 | — | 0.0 | · | | | Carbon Dioxide (land Use Change) | elementary | air/Medium stack, <150 meters / Rural (<… | 0.0013609 | kg | lognormal, GSD² 1.75 | — | 0.2 | · | | | Sulfur hexafluoride | elementary | air/Medium stack, <150 meters / Rural (<… | 3.4000e-10 | kg | lognormal, GSD² 1.94 | — | 0.0 | · | | | Methane (biogenic) | elementary | air/Medium stack, <150 meters / Rural (<… | 2.6424e-07 | kg | lognormal, GSD² 1.83 | — | 0.0 | · | | | Nitrous Oxide | elementary | air/Medium stack, <150 meters / Rural (<… | 2.5618e-08 | kg | lognormal, GSD² 1.84 | — | 0.0 | · | | | Industrial area, DE | elementary | natural resource [DE] | 3.6198e-05 | m2.a | lognormal, GSD² 1.83 | — | 0.0 | · | | | Oils, Unspecified | elementary | soil/Industrial | 9.7600e-09 | kg | lognormal, GSD² 1.94 | — | 0.0 | · | | | To lake, artificial | elementary | natural resource | 2.4132e-05 | m2 | lognormal, GSD² 2.24 | — | 0.0 | · | | | Lake, artificial | elementary | natural resource | 0.0036198 | m2.a | lognormal, GSD² 1.79 | — | 0.0 | · | | | Volume Occupied, Reservoir | elementary | natural resource | 0.16418 | m3.a | lognormal, GSD² 1.52 | — | 0.0 | · | | | Turbine water, DE | elementary | natural resource [DE] | 1.4036 | m3 | lognormal, GSD² 1.52 | — | 0.0 | · | | | Water vapour | elementary | air/Unknown | 0.001752 | m3 | lognormal, GSD² 2.12 | — | 0.0 | · | | | To industrial area | elementary | natural resource | 2.4132e-07 | m2 | lognormal, GSD² 2.28 | — | 0.0 | · | | | Waste Heat | elementary | air/Medium stack, <150 meters / Rural (<… | 0.9 | MJ | lognormal, GSD² 1.57 | — | 0.0 | · | | | From unspecified | elementary | natural resource | 2.4373e-05 | m2 | lognormal, GSD² 2.24 | — | 0.0 | · | | | Oils, Unspecified | elementary | water/River | 2.2680e-08 | kg | lognormal, GSD² 1.94 | — | 0.0 | · | | | Water, DE | elementary | water/Unknown [DE] | 1.4036 | m3 | lognormal, GSD² 2.52 | — | 0.0 | · | | ==== Data quality ==== 0 of 20 direct exchanges carry a declared pedigree, 20 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Philippe Stolz (TREEZE); data entry: Philippe Stolz (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | Some generic datasets from ecoinvent have been used. | | sampling procedure | Statistics | | production volume | na | | uncertainty adjustments | | | validation details | Proof reading validation: 20.07.2020; Other validation: G:\Projekte laufend\651 Strommixe LCA Gebäude BFE\EcoSpold[651-Electricity-Mixes-Attributional-CH-v0.19.xlsx]X-Process; | | time period comment | Time of publications | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **0.001065** | 6.977e-04 | 0.001925 | 1.69 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.005434** | 0.002966 | 0.01071 | 1.91 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.625** | 0.3958 | 1.085 | 1.67 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.001404** | 8.399e-04 | 0.002409 | 1.72 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.6318** | 0.4016 | 1.092 | 1.67 | | EF-particulate Matter | Impact on human health | disease incidence | **5.678e-09** | 4.041e-09 | 1.143e-08 | 1.71 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.82** | 1.042 | 4.011 | 1.99 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.007728** | 0.005252 | 0.0304 | 2.38 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.828** | 1.052 | 4.029 | 1.99 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **4.299e-04** | 2.767e-04 | 8.011e-04 | 1.71 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **9.242e-04** | 3.317e-04 | 0.003737 | 3.39 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **0.002302** | 0.00155 | 0.004363 | 1.71 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.400e-11** | 3.644e-11 | 2.525e-10 | 2.71 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.670e-10** | 9.477e-11 | 3.269e-10 | 1.84 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.210e-10** | 1.403e-10 | 4.890e-10 | 1.9 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.533e-09** | 2.120e-09 | 1.595e-08 | 2.72 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.158e-10** | 8.377e-11 | 2.418e-10 | 1.75 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **3.649e-09** | 2.204e-09 | 1.606e-08 | 2.67 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.2324** | 0.05717 | 1.576 | 5.6 | | Land use | Soil quality index | pt (soil quality index) | **3.965** | 2.164 | 8.833 | 2.05 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **8.524e-09** | 4.599e-09 | 2.460e-08 | 2.35 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **7.673e-04** | 5.148e-04 | 0.001526 | 1.75 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **8.731** | 5.614 | 16.64 | 1.74 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **2.667e-07** | 1.907e-07 | 6.579e-07 | 1.9 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.07034** | -102.6 | 57.73 | — | Climate change 0.6318 kg CO2 eq per kWh. Main contributors: Electricity, high voltage, operation storage pumps, ENTSO, w… 99 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electricity, high voltage, operation storage pumps, ENTSO, w… 99 %. Most sensitive exchanges (Section 6.3): Electricity, high voltage, operation storage pumps, ENTSO, winter 2018, at grid [DE] (-35.4 / +55.0 %); Reservoir hydropower plant [CH] (-0.4 / +1.3 %); Carbon Dioxide (land Use Change) [air/Medium stack, <150 meters / Rural (<1000 people/squa… (-0.1 / +0.2 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh: ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 0.001065 | 9.179e-04 | 1.161 | | Climate change-Biogenic | 0.005434 | 0.005434 | 1.000 | | Climate change-Fossil | 0.625 | 0.625 | 1.000 | | Climate change-Land use and land use change | 0.001404 | 0.001404 | 1.000 | | Climate change | 0.6318 | 0.6318 | 1.000 | | EF-particulate Matter | 5.678e-09 | 5.678e-09 | 1.000 | | Ecotoxicity, freshwater_inorganics | 1.82 | 1.89 | 0.963 | | Ecotoxicity, freshwater_organics | 0.007728 | 0.007664 | 1.008 | | Ecotoxicity, freshwater | 1.828 | 1.897 | 0.964 | | Eutrophication marine | 4.299e-04 | 4.299e-04 | 1.000 | | Eutrophication, freshwater | 9.242e-04 | 9.242e-04 | 1.000 | | Eutrophication, terrestrial | 0.002302 | 0.002798 | 0.823 | | Human toxicity, cancer_inorganics | 5.400e-11 | 4.341e-11 | 1.244 | | Human toxicity, cancer_organics | 1.670e-10 | 1.670e-10 | 1.000 | | Human toxicity, cancer | 2.210e-10 | 2.104e-10 | 1.050 | | Human toxicity, non-cancer_inorganics | 3.533e-09 | 3.137e-09 | 1.126 | | Human toxicity, non-cancer_organics | 1.158e-10 | 1.158e-10 | 1.000 | | Human toxicity, non-cancer | 3.649e-09 | 3.253e-09 | 1.122 | | Ionising radiation, human health | 0.2324 | 0.2324 | 1.000 | | Land use | 3.965 | 3.188 | 1.244 | | Ozone depletion | 8.524e-09 | 8.524e-09 | 1.000 | | Photochemical ozone formation - human health | 7.673e-04 | 7.673e-04 | 1.000 | | Resource use, fossils | 8.731 | 8.731 | 1.000 | | Resource use, minerals and metals | 2.667e-07 | 2.596e-07 | 1.027 | | Water use | 0.07034 | 0.1102 | 0.638 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.6318 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 887.7 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Electricity, high voltage, operation storage pumps, ENTSO, winter 2018, at grid [DE] | 1.25 kWh | ×0.643 / ×1.55 | lognormal, GSD² 1.57 | -35.4 / +55.0 | 56.0 (Land use) | | Reservoir hydropower plant [CH] | 3.347e-11 p | ×0.313 / ×3.2 | lognormal, GSD² 3.27 | -0.4 / +1.3 | 19.3 (Resource use, minerals and metals) | | Carbon Dioxide (land Use Change) [air/Medium stack, <150 meters / Rural (<1000 people/squa… | 0.001361 kg | ×0.576 / ×1.73 | lognormal, GSD² 1.75 | -0.1 / +0.2 | 71.2 (Climate change-Land use and land use change) | | Sulfur hexafluoride [air/Medium stack, <150 meters / Rural (<1000 people/square mile)] | 3.400e-10 kg | ×0.523 / ×1.91 | lognormal, GSD² 1.94 | -0.0 / +0.0 | 0.0 (Climate change-Fossil) | | Methane (biogenic) [air/Medium stack, <150 meters / Rural (<1000 people/square mile)] | 2.642e-07 kg | ×0.552 / ×1.81 | lognormal, GSD² 1.83 | -0.0 / +0.0 | 0.1 (Climate change-Biogenic) | | Nitrous Oxide [air/Medium stack, <150 meters / Rural (<1000 people/square mile)] | 2.562e-08 kg | ×0.549 / ×1.82 | lognormal, GSD² 1.84 | -0.0 / +0.0 | 0.0 (Climate change-Fossil) | | Sulphur hexafluoride, liquid, at plant [RER] | 3.400e-10 kg | ×0.598 / ×1.67 | lognormal, GSD² 1.69 | -0.0 / +0.0 | 0.0 (Climate change-Fossil) | | Lubricating oil, at plant [RER] | 3.244e-08 kg | ×0.598 / ×1.67 | lognormal, GSD² 1.69 | -0.0 / +0.0 | 0.0 (Ecotoxicity, freshwater_organics) | | Industrial area, DE [natural resource [DE%%]]%% | 3.620e-05 m2.a | ×0.555 / ×1.8 | lognormal, GSD² 1.83 | -0.0 / +0.0 | 0.1 (Land use) | | Oils, Unspecified [soil/Industrial] | 9.760e-09 kg | ×0.523 / ×1.91 | lognormal, GSD² 1.94 | -0.0 / +0.0 | 0.0 (Ecotoxicity, freshwater_organics) | | Turbine water, DE [natural resource [DE%%]]%% | 1.404 m3 | ×0.663 / ×1.51 | lognormal, GSD² 1.52 | -0.0 / +0.0 | 1379.4 (Water use) | | To industrial area [natural resource] | 2.413e-07 m2 | ×0.446 / ×2.24 | lognormal, GSD² 2.28 | -0.0 / +0.0 | 0.0 (Land use) | | From unspecified [natural resource] | 2.437e-05 m2 | ×0.453 / ×2.21 | lognormal, GSD² 2.24 | -0.0 / +0.0 | 2.2 (Land use) | | Oils, Unspecified [water/River] | 2.268e-08 kg | ×0.523 / ×1.91 | lognormal, GSD² 1.94 | -0.0 / +0.0 | 0.2 (Ecotoxicity, freshwater_organics) | | Water, DE [water/Unknown [DE%%]]%% | 1.404 m3 | ×0.404 / ×2.47 | lognormal, GSD² 2.52 | -0.0 / +0.0 | 3998.8 (Water use) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== ^ Source ^ Scope ^ Value ^ This dataset ^ Ratio ^ Note ^ | bafu | Electricity, hydropower, at pumped storage plant, ENTSO, winter 2018 [FR] | 0.09178 kg CO2 eq | 0.6318 | 6.88 | same dataset name, other location | | bafu | Electricity, hydropower, at pumped storage plant, ENTSO, winter 2018 [CH] | 0.1791 kg CO2 eq | 0.6318 | 3.53 | same dataset name, other location | | bafu | Electricity, hydropower, at pumped storage plant, ENTSO, winter 2018 [AT] | 0.2466 kg CO2 eq | 0.6318 | 2.56 | same dataset name, other location | | bafu | Electricity, hydropower, at pumped storage plant, ENTSO, winter 2018 [IT] | 0.8888 kg CO2 eq | 0.6318 | 0.71 | same dataset name, other location | ==== Conclusions and limitations ==== GWP100 0.6318 kg CO2 eq per kWh (95 % interval 0.4016–1.092). Dominant contributors: Electricity, high voltage, operation storage pumps, ENTSO, w… 99 %. Most sensitive: Electricity, high voltage, operation storage pumps, ENTSO, winter 2018, at grid [DE] (-35.4 / +55.0 %); Reservoir hydropower plant [CH] (-0.4 / +1.3 %); Carbon Dioxide (land Use Change) [air/Medium stack, <150 meters / Rural (<1000 people/squa… (-0.1 / +0.2 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kWh | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.5e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 17/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 20/20 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.6318 in [0.4016, 1.092] | | time period declared | **PASS** | 2018-01/2018-12 | | geography is a known location code | **PASS** | DE | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Stolz P., Frischknecht R. (2020) Electricity Mixes in Life Cycle Assessments of Buildings. Project report. Volume: 651. treeze Ltd.. Uster, CH. Type: Separate publication Source: Report First author: Stolz P. Other authors: Frischknecht R. Year: 2020 Title of anthology: Project report Place of publication: Uster, CH Publisher: treeze Ltd. Volume No: 651 — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].