====== Disposal, ventilation unit 1800 m3/h, w. rotary heat exchanger — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:disposal_ventilation_unit_1800_m3_h_w_rotary_heat_exchanger__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Disposal, ventilation unit 1800 m3/h, w. rotary heat exchanger [CH], per 1 p. EF v3.1 climate change 179 kg CO2 eq (Monte Carlo 95 % interval 156–230.6). Main contributors: Disposal, polyethylene terephtalate, 0.2% water, to municipa… 42 %; Disposal, building, polyurethane foam, to final disposal 33 %; Disposal, control and wiring, central unit 12 %; Disposal, rubber, unspecified, 0% water, to municipal incine… 6 %; Disposal, building, polyethylene/polypropylene products, to … 5 %; Disposal, building, bulk iron (excluding reinforcement), to … 2 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Disposal, ventilation unit 1800 m3/h, w. rotary heat exchanger | | Dataset UUID / graph id | ''%%6bd83b32-6ff8-4710-bdc2-52a7336e12d1%%'' / ''%%activity:disposal_ventilation_unit_1800_m3_h_w_rotary_heat_exchanger__ch%%'' | | Reference product, unit | Disposal, ventilation unit 1800 m3/h, w. rotary heat exchanger, 1 p | | Location | CH — Specific to the technology mix encountered in sorting plants in Switzerland. | | Time period | 2014-01/2014-12 | | Category | waste management / building demolition | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Disposal of a ventilation unit (air handling unit) with 1800 m3/h nominal air flow rate (at 2 m/s air speed in cross section of air filter or heat exchanger), component weight: 757 kg, total weight: 921 kg/Unit, including average components for controls, inverter and electric control cabinet, material for 20 filter replacements (once a year for 20 years lifetime). The air handling unit includes a frame construction, two radial belt drive fans, two multi-leaf damper, heat recovery with aluminium rotary heat exchanger (thermal wheel), heating elements, expansion plenum and empty section in supply and extract air. No cooling elements, humidifier, air-mixing plenum and silencer included. The frame construction made of aluminium-profiles, casing made of hot-dip galvanized and powder coated steel sheets insulated with polyurethane foam.; UUID: 6bd83b32-6ff8-4710-bdc2-52a7336e12d1 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Disposal, ventilation unit 1800 m3/h, w. rotary heat exchanger (CH). All results are given per unit of the reference flow. ==== System boundary ==== Transport to dismantling facilities, machines for handling in sorting plant, electricity demand for sorting plant, final disposal of waste material. Cut-off to recycling for metals. ==== Technology ==== Disposal to a sorting plant assumed. Metal pieces, copper in cables and electronic devices are recycled, plastic parts are incinerated, inert wastes (e.g. rock wool) are landfilled. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Disposal, polyethylene terephtalate, 0.2% water, to municipal incineration | technosphere | CH | 36.192 | kg | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 41.9 | ████████ | | | Disposal, building, polyurethane foam, to final disposal | technosphere | CH | 21.854 | kg | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 33.4 | ███████ | | | Disposal, control and wiring, central unit | technosphere | CH | 4.8611 | p | lognormal, GSD² 1.34 | (3,4,1,1,3,5) | 11.9 | ██ | | | Disposal, rubber, unspecified, 0% water, to municipal incineration | technosphere | CH | 3.606 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 6.4 | █ | | | Disposal, building, polyethylene/polypropylene products, to final disposal | technosphere | CH | 2.6975 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 4.6 | █ | | | Disposal, building, bulk iron (excluding reinforcement), to sorting plant | technosphere | CH | 837.29 | kg | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.6 | · | | | Disposal, wood untreated, 20% water, to municipal incineration | technosphere | CH | 18.096 | kg | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.2 | · | | | Transport, freight, lorry, 16t-32t gross weight, fleet average | technosphere | CH | 0.54288 | tkm | lognormal, GSD² 2.14 | (4,5,1,1,1,5) | 0.1 | · | | | Disposal, building, paint on metal, to sorting plant | technosphere | CH | 15.45 | kg | lognormal, GSD² 1.32 | (4,4,1,1,1,5) | 0.0 | · | | | Disposal, glass, 0% water, to municipal incineration | technosphere | CH | 1.1561 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.0 | · | | ==== Data quality ==== 10 of 10 direct exchanges carry a declared pedigree, 10 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.8 · completeness 4.1 · temporal 1.0 · geographical 1.0 · technological 1.2 · sample size 5.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU) | | extrapolations | none | | sampling procedure | Waste-specific calculation based on production input data | | production volume | na | | uncertainty adjustments | none | | time period comment | Amount of material investigated in 2013. Disposal technology mix as used in late 1990ies | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **0.03652** | 0.02505 | 0.1175 | 2.21 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.01732** | 0.01322 | 0.04489 | 1.86 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **179** | 156 | 230.6 | 1.22 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.002766** | 0.002328 | 0.005377 | 1.52 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **179** | 156 | 230.6 | 1.22 | | EF-particulate Matter | Impact on human health | disease incidence | **4.193e-07** | 3.645e-07 | 1.055e-06 | 1.69 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **822.5** | 615 | 1357 | 1.51 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.138** | 0.968 | 3.146 | 1.81 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **823.6** | 616.3 | 1360 | 1.5 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **0.05896** | 0.03775 | 0.1838 | 2.23 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **0.001307** | 0.001084 | 0.009483 | 3.19 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **0.3527** | 0.1883 | 1.35 | 2.76 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.019e-08** | 8.892e-09 | 4.785e-08 | 2.33 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.222e-09** | 1.144e-09 | 2.826e-09 | 1.59 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.141e-08** | 1.022e-08 | 4.917e-08 | 2.19 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **6.187e-07** | 5.541e-07 | 2.585e-06 | 2.24 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.156e-09** | 4.616e-09 | 1.134e-08 | 1.55 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **6.238e-07** | 5.600e-07 | 2.591e-06 | 2.23 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **2.431** | 0.9517 | 15.41 | 4.23 | | Land use | Soil quality index | pt (soil quality index) | **69.62** | 61.27 | 106.1 | 1.32 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **3.537e-07** | 2.960e-07 | 9.629e-07 | 1.77 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **0.1196** | 0.06852 | 0.4255 | 2.56 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **147.5** | 115.4 | 449.7 | 1.97 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **2.161e-05** | 1.853e-05 | 5.105e-05 | 1.67 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **27.36** | -1195 | 678.2 | — | Climate change 179 kg CO2 eq per p. Main contributors: Disposal, polyethylene terephtalate, 0.2% water, to municipa… 42 %; Disposal, building, polyurethane foam, to final disposal 33 %; Disposal, control and wiring, central unit 12 %; Disposal, rubber, unspecified, 0% water, to municipal incine… 6 %; Disposal, building, polyethylene/polypropylene products, to … 5 %; Disposal, building, bulk iron (excluding reinforcement), to … 2 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Disposal, polyethylene terephtalate, 0.2% water, to municipa… 42 %; Disposal, building, polyurethane foam, to final disposal 33 %; Disposal, control and wiring, central unit 12 %; Disposal, rubber, unspecified, 0% water, to municipal incine… 6 %; Disposal, building, polyethylene/polypropylene products, to … 5 %; Disposal, building, bulk iron (excluding reinforcement), to … 2 %. Most sensitive exchanges (Section 6.3): Disposal, polyethylene terephtalate, 0.2% water, to municipal incineration [CH] (-8.0 / +9.8 %); Disposal, building, polyurethane foam, to final disposal [CH] (-6.4 / +7.8 %); Disposal, control and wiring, central unit [CH] (-3.0 / +4.0 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 0.03652 | 0.08787 | 0.416 | | Climate change-Biogenic | 0.01732 | 0.01732 | 1.000 | | Climate change-Fossil | 179 | 179 | 1.000 | | Climate change-Land use and land use change | 0.002766 | 0.002766 | 1.000 | | Climate change | 179 | 179 | 1.000 | | EF-particulate Matter | 4.193e-07 | 4.193e-07 | 1.000 | | Ecotoxicity, freshwater_inorganics | 822.5 | 866.6 | 0.949 | | Ecotoxicity, freshwater_organics | 1.138 | 1.133 | 1.004 | | Ecotoxicity, freshwater | 823.6 | 867.7 | 0.949 | | Eutrophication marine | 0.05896 | 0.05896 | 1.000 | | Eutrophication, freshwater | 0.001307 | 0.001307 | 1.000 | | Eutrophication, terrestrial | 0.3527 | 0.4526 | 0.779 | | Human toxicity, cancer_inorganics | 1.019e-08 | 1.017e-08 | 1.002 | | Human toxicity, cancer_organics | 1.222e-09 | 1.222e-09 | 1.000 | | Human toxicity, cancer | 1.141e-08 | 1.139e-08 | 1.001 | | Human toxicity, non-cancer_inorganics | 6.187e-07 | 6.162e-07 | 1.004 | | Human toxicity, non-cancer_organics | 5.156e-09 | 5.155e-09 | 1.000 | | Human toxicity, non-cancer | 6.238e-07 | 6.213e-07 | 1.004 | | Ionising radiation, human health | 2.431 | 2.431 | 1.000 | | Land use | 69.62 | 46.67 | 1.492 | | Ozone depletion | 3.537e-07 | 3.537e-07 | 1.000 | | Photochemical ozone formation - human health | 0.1196 | 0.1196 | 1.000 | | Resource use, fossils | 147.5 | 147.5 | 1.000 | | Resource use, minerals and metals | 2.161e-05 | 1.521e-05 | 1.420 | | Water use | 27.36 | 27.41 | 0.998 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 179 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 1.922e+05 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Disposal, polyethylene terephtalate, 0.2% water, to municipal incineration [CH] | 36.19 kg | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -8.0 / +9.8 | 9.8 (Climate change-Fossil) | | Disposal, building, polyurethane foam, to final disposal [CH] | 21.85 kg | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -6.4 / +7.8 | 15.7 (Eutrophication marine) | | Disposal, control and wiring, central unit [CH] | 4.861 p | ×0.751 / ×1.33 | lognormal, GSD² 1.34 | -3.0 / +4.0 | 25.4 (Water use) | | Disposal, rubber, unspecified, 0% water, to municipal incineration [CH] | 3.606 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -1.3 / +1.6 | 1.6 (Climate change-Fossil) | | Disposal, building, polyethylene/polypropylene products, to final disposal [CH] | 2.697 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.9 / +1.2 | 1.2 (Climate change-Fossil) | | Disposal, building, bulk iron (excluding reinforcement), to sorting plant [CH] | 837.3 kg | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.3 / +0.4 | 15.6 (Ionising radiation, human health) | | Transport, freight, lorry, 16t-32t gross weight, fleet average [CH] | 0.5429 tkm | ×0.474 / ×2.11 | lognormal, GSD² 2.14 | -0.0 / +0.1 | 1.8 (Ecotoxicity, freshwater_organics) | | Disposal, wood untreated, 20% water, to municipal incineration [CH] | 18.1 kg | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.0 / +0.0 | 2.0 (Eutrophication, freshwater) | | Disposal, building, paint on metal, to sorting plant [CH] | 15.45 kg | ×0.762 / ×1.31 | lognormal, GSD² 1.32 | -0.0 / +0.0 | 0.5 (Human toxicity, non-cancer_organics) | | Disposal, glass, 0% water, to municipal incineration [CH] | 1.156 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.0 / +0.0 | 0.4 (Land use) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 179 kg CO2 eq per p (95 % interval 156–230.6). Dominant contributors: Disposal, polyethylene terephtalate, 0.2% water, to municipa… 42 %; Disposal, building, polyurethane foam, to final disposal 33 %; Disposal, control and wiring, central unit 12 %; Disposal, rubber, unspecified, 0% water, to municipal incine… 6 %; Disposal, building, polyethylene/polypropylene products, to … 5 %; Disposal, building, bulk iron (excluding reinforcement), to … 2 %. Most sensitive: Disposal, polyethylene terephtalate, 0.2% water, to municipal incineration [CH] (-8.0 / +9.8 %); Disposal, building, polyurethane foam, to final disposal [CH] (-6.4 / +7.8 %); Disposal, control and wiring, central unit [CH] (-3.0 / +4.0 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.2e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 19/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 10/10 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 179 in [156, 230.6] | | time period declared | **PASS** | 2014-01/2014-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].