====== 3kWp flat roof installation, single-Si, on roof — CN ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:3kwp_flat_roof_installation_single_si_on_roof__cn|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset 3kWp flat roof installation, single-Si, on roof [CN], per 1 p. EF v3.1 climate change 3039 kg CO2 eq (Monte Carlo 95 % interval 2650–4237). Main contributors: Photovoltaic panel, single-Si, at plant 59 %; Inverter, 2.5 kW, average, at plant 21 %; Flat roof construction, on roof 13 %; Electric installation, photovoltaic plant, at plant 4 %; Treatment, c-Si PV module 2 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | 3kWp flat roof installation, single-Si, on roof | | Dataset UUID / graph id | ''%%6c54f878-eab9-38b1-8d43-10520af5c4a7%%'' / ''%%activity:3kwp_flat_roof_installation_single_si_on_roof__cn%%'' | | Reference product, unit | 3kWp flat roof installation, single-Si, on roof, 1 p | | Location | CN — Installation in China. | | Time period | 2000-01/2018-12 | | Category | photovoltaic / production of components | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Photovoltaic installation with a capacity of 3kWp and a life time of 30 years installed in China. The efficiency of single-Si PV modules is 17.9% (Fraunhofer ISE Photovoltaics Report 2019). The share of rejected or replaced PV modules is estimated at 3%. The inverter is assumed to be replaced once during the service life of the PV system.; Synonyms: monocrystalline, single crystalline, silicon; UUID: 6c54f878-eab9-38b1-8d43-10520af5c4a7 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of 3kWp flat roof installation, single-Si, on roof (CN). All results are given per unit of the reference flow. ==== System boundary ==== All components for the installation of a 3kWp photovoltaic plant, energy use for the mounting, transport of materials and persons to the construction place. Disposal of components after end of life. ==== Technology ==== Current technology for mounting of panels or laminates, electric installations and other components. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Photovoltaic panel, single-Si, at plant | technosphere | CN | 15.846 | m2 | lognormal, GSD² 1.36 | (3,4,3,1,1,5) | 59.5 | ████████████ | | | Inverter, 2.5 kW, average, at plant | technosphere | RER | 2.4 | p | lognormal, GSD² 1.24 | — | 20.9 | ████ | | | Flat roof construction, on roof | technosphere | RER | 15.385 | m2 | lognormal, GSD² 1.23 | — | 13.1 | ███ | | | Electric installation, photovoltaic plant, at plant | technosphere | CH | 1 | p | lognormal, GSD² 2.09 | (3,4,3,1,1,5) | 4.1 | █ | | | Treatment, c-Si PV module | technosphere | RER | 208.39 | kg | lognormal, GSD² 1.28 | (3,4,3,1,1,5) | 1.9 | · | | | Transport, freight, lorry, 7.5t-16t gross weight, fleet average | technosphere | RER | 34.082 | tkm | lognormal, GSD² 2.09 | (3,4,3,1,1,5) | 0.5 | · | | | Electricity, low voltage, at grid | technosphere | CN | 1.02 | kWh | lognormal, GSD² 1.28 | (3,4,3,1,1,5) | 0.0 | · | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 3.672 | MJ | lognormal, GSD² 1.28 | (3,4,3,1,1,5) | 0.0 | · | | ==== Data quality ==== 6 of 8 direct exchanges carry a declared pedigree, 8 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.0 · completeness 4.0 · temporal 3.0 · geographical 1.0 · technological 1.0 · sample size 5.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Philippe Stolz (TREEZE); data entry: Philippe Stolz (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | Estimations for lifetime of PV modules (30a) and inverters (15a) as well as for transport distances. Modules are assumed to be produced in China. | | sampling procedure | Publication for efficiency, mounting systems and own estimations for other components. | | production volume | Total installed capacity in 2018: approximately 175 GWp in China. | | uncertainty adjustments | | | validation details | Proof reading validation: 30.09.2020; Other validation: G:\Projekte laufend\174 Photovoltaic, IEA Task 12\2017 Global supply chain\EcoSpold[174-photovoltaics-global-supply-chain-v2.5.xlsx]X-Process; | | time period comment | Average module efficiency in 2018. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **12.95** | 11.43 | 19.04 | 1.3 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **13.12** | 7.695 | 33.3 | 2.06 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **3025** | 2639 | 4213 | 1.28 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.522** | 1.223 | 2.42 | 1.42 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **3039** | 2650 | 4237 | 1.28 | | EF-particulate Matter | Impact on human health | disease incidence | **1.009e-04** | 9.194e-05 | 4.517e-04 | 2.12 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.977e+04** | 1.811e+04 | 3.672e+04 | 1.45 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **363.7** | 334.7 | 660.6 | 1.41 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.013e+04** | 1.854e+04 | 3.731e+04 | 1.45 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **3.943** | 3.338 | 6.198 | 1.38 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **4.296** | 2.743 | 26.61 | 3.17 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **25.46** | 22.63 | 39.79 | 1.34 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.664e-06** | 1.639e-06 | 4.686e-06 | 1.73 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.556e-07** | 6.295e-07 | 1.301e-06 | 1.46 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.419e-06** | 2.433e-06 | 5.611e-06 | 1.56 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.121e-04** | 1.062e-04 | 3.036e-04 | 1.77 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.237e-06** | 3.726e-06 | 1.004e-05 | 1.69 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.173e-04** | 1.117e-04 | 3.092e-04 | 1.74 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **646.6** | 211.2 | 4504 | 4.76 | | Land use | Soil quality index | pt (soil quality index) | **2.125e+04** | 1.835e+04 | 3.589e+04 | 1.42 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **1.081e-04** | 9.285e-05 | 1.704e-04 | 1.37 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **9.063** | 8.256 | 13.77 | 1.3 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **3.972e+04** | 3.424e+04 | 6.06e+04 | 1.34 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.4853** | 0.3687 | 0.6966 | 1.39 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **2472** | -6.255e+05 | 3.438e+05 | — | Climate change 3039 kg CO2 eq per p. Main contributors: Photovoltaic panel, single-Si, at plant 59 %; Inverter, 2.5 kW, average, at plant 21 %; Flat roof construction, on roof 13 %; Electric installation, photovoltaic plant, at plant 4 %; Treatment, c-Si PV module 2 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Photovoltaic panel, single-Si, at plant 59 %; Inverter, 2.5 kW, average, at plant 21 %; Flat roof construction, on roof 13 %; Electric installation, photovoltaic plant, at plant 4 %; Treatment, c-Si PV module 2 %. Most sensitive exchanges (Section 6.3): Photovoltaic panel, single-Si, at plant [CN] (-15.4 / +20.8 %); Inverter, 2.5 kW, average, at plant [RER] (-3.9 / +4.8 %); Electric installation, photovoltaic plant, at plant [CH] (-2.1 / +4.4 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 12.95 | 13.81 | 0.938 | | Climate change-Biogenic | 13.12 | 13.12 | 1.000 | | Climate change-Fossil | 3025 | 3025 | 1.000 | | Climate change-Land use and land use change | 1.522 | 1.522 | 1.000 | | Climate change | 3039 | 3039 | 1.000 | | EF-particulate Matter | 1.009e-04 | 1.009e-04 | 1.000 | | Ecotoxicity, freshwater_inorganics | 1.977e+04 | 2.034e+04 | 0.972 | | Ecotoxicity, freshwater_organics | 363.7 | 306.8 | 1.186 | | Ecotoxicity, freshwater | 2.013e+04 | 2.051e+04 | 0.982 | | Eutrophication marine | 3.943 | 3.943 | 1.000 | | Eutrophication, freshwater | 4.296 | 4.296 | 1.000 | | Eutrophication, terrestrial | 25.46 | 26.42 | 0.964 | | Human toxicity, cancer_inorganics | 1.664e-06 | 1.655e-06 | 1.005 | | Human toxicity, cancer_organics | 7.556e-07 | 7.555e-07 | 1.000 | | Human toxicity, cancer | 2.419e-06 | 2.411e-06 | 1.003 | | Human toxicity, non-cancer_inorganics | 1.121e-04 | 1.115e-04 | 1.005 | | Human toxicity, non-cancer_organics | 5.237e-06 | 5.234e-06 | 1.000 | | Human toxicity, non-cancer | 1.173e-04 | 1.167e-04 | 1.005 | | Ionising radiation, human health | 646.6 | 646.6 | 1.000 | | Land use | 2.125e+04 | 1.738e+04 | 1.222 | | Ozone depletion | 1.081e-04 | 1.081e-04 | 1.000 | | Photochemical ozone formation - human health | 9.063 | 9.062 | 1.000 | | Resource use, fossils | 3.972e+04 | 3.973e+04 | 1.000 | | Resource use, minerals and metals | 0.4853 | 0.4838 | 1.003 | | Water use | 2472 | 2498 | 0.990 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 3036 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 7.569e+06 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Photovoltaic panel, single-Si, at plant [CN] | 15.85 m2 | ×0.741 / ×1.35 | lognormal, GSD² 1.36 | -15.4 / +20.8 | 32.9 (Water use) | | Inverter, 2.5 kW, average, at plant [RER] | 2.4 p | ×0.813 / ×1.23 | lognormal, GSD² 1.24 | -3.9 / +4.8 | 18.8 (Resource use, minerals and metals) | | Electric installation, photovoltaic plant, at plant [CH] | 1 p | ×0.486 / ×2.06 | lognormal, GSD² 2.09 | -2.1 / +4.4 | 49.2 (Human toxicity, non-cancer_organics) | | Flat roof construction, on roof [RER] | 15.38 m2 | ×0.817 / ×1.22 | lognormal, GSD² 1.23 | -2.4 / +2.9 | 4.7 (Climate change-Land use and land use change) | | Treatment, c-Si PV module [RER] | 208.4 kg | ×0.782 / ×1.28 | lognormal, GSD² 1.28 | -0.4 / +0.5 | 1.2 (Climate change-Land use and land use change) | | Transport, freight, lorry, 7.5t-16t gross weight, fleet average [RER] | 34.08 tkm | ×0.486 / ×2.06 | lognormal, GSD² 2.09 | -0.2 / +0.5 | 3.8 (Climate change-Land use and land use change) | | Electricity, low voltage, at grid [CN] | 1.02 kWh | ×0.782 / ×1.28 | lognormal, GSD² 1.28 | -0.0 / +0.0 | 0.0 (Human toxicity, cancer_organics) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== ^ Source ^ Scope ^ Value ^ This dataset ^ Ratio ^ Note ^ | bafu | 3kWp flat roof installation, single-Si, on roof [APAC] | 2967 kg CO2 eq | 3039 | 1.02 | same dataset name, other location | | bafu | 3kWp flat roof installation, single-Si, on roof [US] | 3034 kg CO2 eq | 3039 | 1.00 | same dataset name, other location | | bafu | 3kWp flat roof installation, single-Si, on roof [CH] | 3042 kg CO2 eq | 3039 | 1.00 | same dataset name, other location | | bafu | 3kWp flat roof installation, single-Si, on roof [RER] | 3042 kg CO2 eq | 3039 | 1.00 | same dataset name, other location | ==== Conclusions and limitations ==== GWP100 3039 kg CO2 eq per p (95 % interval 2650–4237). Dominant contributors: Photovoltaic panel, single-Si, at plant 59 %; Inverter, 2.5 kW, average, at plant 21 %; Flat roof construction, on roof 13 %; Electric installation, photovoltaic plant, at plant 4 %; Treatment, c-Si PV module 2 %. Most sensitive: Photovoltaic panel, single-Si, at plant [CN] (-15.4 / +20.8 %); Inverter, 2.5 kW, average, at plant [RER] (-3.9 / +4.8 %); Electric installation, photovoltaic plant, at plant [CH] (-2.1 / +4.4 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.1e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 22/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 8/8 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 3039 in [2650, 4237] | | time period declared | **PASS** | 2000-01/2018-12 | | geography is a known location code | **PASS** | CN | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 1 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Frischknecht Rolf Stolz Philippe Krebs Luana de Wild-Scholten Mariska Sinha Parikhit (2020). Task 12 PV Sustainability - Life Cycle Inventories and Life Cycle Assessments of Photovoltaic Systems. Office of Scientific and Technical Information (OSTI). https://doi.org/10.2172/2308831 — //published source; matched in Crossref (author, year ±1, title overlap)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].