====== xx Heat, air-water heat pump 10kW, at heat radiator — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:xx_heat_air_water_heat_pump_10kw_at_heat_radiator__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset xx Heat, air-water heat pump 10kW, at heat radiator [CH], per 1 MJ. EF v3.1 climate change 0.01569 kg CO2 eq (Monte Carlo 95 % interval 0.01348–0.02283). Main contributors: Heat, at heat pump, air-water, 15kW, CH electricity, in old … 90 %; Heat distribution, hydronic radiant floor heating, 150m2 10 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | xx Heat, air-water heat pump 10kW, at heat radiator | | Dataset UUID / graph id | ''%%6d661f73-707f-3054-b8ee-93a9ae32fb83%%'' / ''%%activity:xx_heat_air_water_heat_pump_10kw_at_heat_radiator__ch%%'' | | Reference product, unit | xx Heat, air-water heat pump 10kW, at heat radiator, 1 MJ | | Location | CH — Operation in Switzerland (i.e. Swiss electricity mix) | | Time period | 1998-01/2000-12 | | Category | energy, obsolete / heat, obsolete\heat pumps, obsolete | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Heat after distribution.; UUID: 6d661f73-707f-3054-b8ee-93a9ae32fb83 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 MJ** of xx Heat, air-water heat pump 10kW, at heat radiator (CH). All results are given per unit of the reference flow. ==== System boundary ==== Includes heat from heat pump and heat distribution. ==== Technology ==== Based on average SPF2 (Seasonal Performance Factor, including auxiliary energy) of air-water heat pumps installed in year 1998 operating in Switzerland. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Heat, at heat pump, air-water, 15kW, CH electricity, in old building | technosphere | CH | 1.05 | MJ | lognormal, GSD² 1.05 | — | 90.2 | ██████████████████ | | | Heat distribution, hydronic radiant floor heating, 150m2 | technosphere | CH | 7.2900e-07 | p | lognormal, GSD² 1.5 | — | 9.8 | ██ | | ==== Data quality ==== 0 of 2 direct exchanges carry a declared pedigree, 2 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Thomas Heck; data entry: Thomas Heck; validation (proof reading): Gerald Rebitzer | | extrapolations | none | | sampling procedure | Literature | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: prepared; Other validation: none; | | time period comment | undefined | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 MJ. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **3.541e-05** | 2.839e-05 | 6.816e-05 | 1.56 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2.930e-04** | 2.051e-04 | 4.953e-04 | 1.57 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.01536** | 0.01322 | 0.02245 | 1.31 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **3.475e-05** | 2.329e-05 | 5.534e-05 | 1.55 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.01569** | 0.01348 | 0.02283 | 1.31 | | EF-particulate Matter | Impact on human health | disease incidence | **5.788e-10** | 4.447e-10 | 1.073e-09 | 1.55 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.04114** | 0.03648 | 0.1029 | 1.7 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **9.042e-04** | 8.038e-04 | 0.002386 | 1.76 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.04205** | 0.03739 | 0.1047 | 1.69 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **1.061e-05** | 9.044e-06 | 1.704e-05 | 1.38 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **1.341e-05** | 7.982e-06 | 6.507e-05 | 2.83 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **7.511e-05** | 6.496e-05 | 1.272e-04 | 1.42 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.999e-12** | 3.473e-12 | 1.293e-11 | 1.92 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **8.344e-12** | 5.700e-12 | 2.127e-11 | 1.93 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.234e-11** | 1.034e-11 | 2.990e-11 | 1.71 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.492e-10** | 2.057e-10 | 9.658e-10 | 2.17 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.652e-11** | 9.961e-12 | 4.736e-11 | 2.21 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.658e-10** | 2.165e-10 | 1.002e-09 | 2.15 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.07816** | 0.02724 | 0.4492 | 4.22 | | Land use | Soil quality index | pt (soil quality index) | **0.1695** | 0.1137 | 0.3027 | 1.69 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **3.136e-09** | 1.894e-09 | 8.101e-09 | 2.1 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **2.748e-05** | 2.388e-05 | 5.058e-05 | 1.47 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.7982** | 0.6193 | 1.208 | 1.41 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **3.265e-07** | 1.703e-07 | 9.885e-07 | 2.59 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.006958** | -25.03 | 13.6 | — | Climate change 0.01569 kg CO2 eq per MJ. Main contributors: Heat, at heat pump, air-water, 15kW, CH electricity, in old … 90 %; Heat distribution, hydronic radiant floor heating, 150m2 10 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Heat, at heat pump, air-water, 15kW, CH electricity, in old … 90 %; Heat distribution, hydronic radiant floor heating, 150m2 10 %. Most sensitive exchanges (Section 6.3): Heat, at heat pump, air-water, 15kW, CH electricity, in old building [CH] (-4.2 / +4.4 %); Heat distribution, hydronic radiant floor heating, 150m2 [CH] (-3.2 / +4.8 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 3.541e-05 | 3.949e-05 | 0.897 | | Climate change-Biogenic | 2.930e-04 | 2.930e-04 | 1.000 | | Climate change-Fossil | 0.01536 | 0.01536 | 1.000 | | Climate change-Land use and land use change | 3.475e-05 | 3.475e-05 | 1.000 | | Climate change | 0.01569 | 0.01569 | 1.000 | | EF-particulate Matter | 5.788e-10 | 5.788e-10 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.04114 | 0.04394 | 0.936 | | Ecotoxicity, freshwater_organics | 9.042e-04 | 8.801e-04 | 1.027 | | Ecotoxicity, freshwater | 0.04205 | 0.04475 | 0.940 | | Eutrophication marine | 1.061e-05 | 1.058e-05 | 1.003 | | Eutrophication, freshwater | 1.341e-05 | 1.341e-05 | 1.000 | | Eutrophication, terrestrial | 7.511e-05 | 8.469e-05 | 0.887 | | Human toxicity, cancer_inorganics | 3.999e-12 | 3.856e-12 | 1.037 | | Human toxicity, cancer_organics | 8.344e-12 | 8.344e-12 | 1.000 | | Human toxicity, cancer | 1.234e-11 | 1.220e-11 | 1.012 | | Human toxicity, non-cancer_inorganics | 2.492e-10 | 2.420e-10 | 1.030 | | Human toxicity, non-cancer_organics | 1.652e-11 | 1.651e-11 | 1.000 | | Human toxicity, non-cancer | 2.658e-10 | 2.585e-10 | 1.028 | | Ionising radiation, human health | 0.07816 | 0.07816 | 1.000 | | Land use | 0.1695 | 0.1357 | 1.249 | | Ozone depletion | 3.136e-09 | 3.136e-09 | 1.000 | | Photochemical ozone formation - human health | 2.748e-05 | 2.748e-05 | 1.000 | | Resource use, fossils | 0.7982 | 0.7983 | 1.000 | | Resource use, minerals and metals | 3.265e-07 | 3.252e-07 | 1.004 | | Water use | 0.006958 | 0.007723 | 0.901 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.01568 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 61.11 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Heat, at heat pump, air-water, 15kW, CH electricity, in old building [CH] | 1.05 MJ | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -4.2 / +4.4 | 4.9 (Resource use, minerals and metals) | | Heat distribution, hydronic radiant floor heating, 150m2 [CH] | 7.290e-07 p | ×0.672 / ×1.49 | lognormal, GSD² 1.5 | -3.2 / +4.8 | 20.1 (Human toxicity, cancer_organics) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== ^ Source ^ Scope ^ Value ^ This dataset ^ Ratio ^ Note ^ | bafu | xx Heat, air-water heat pump 10kW, at heat radiator [RER] | 0.04089 kg CO2 eq | 0.01569 | 0.38 | same dataset name, other location | ==== Conclusions and limitations ==== GWP100 0.01569 kg CO2 eq per MJ (95 % interval 0.01348–0.02283). Dominant contributors: Heat, at heat pump, air-water, 15kW, CH electricity, in old … 90 %; Heat distribution, hydronic radiant floor heating, 150m2 10 %. Most sensitive: Heat, at heat pump, air-water, 15kW, CH electricity, in old building [CH] (-4.2 / +4.4 %); Heat distribution, hydronic radiant floor heating, 150m2 [CH] (-3.2 / +4.8 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 MJ | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 1.9e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 19/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 2/2 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.01569 in [0.01348, 0.02283] | | time period declared | **PASS** | 1998-01/2000-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Heck, T. (2007) Wärmepumpen. Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0. Editors: Dones R.. Volume: 6. Swiss Centre for LCI, PSI. Dübendorf and Villigen, CH. Type: Measurement on site Source: CD-ROM First author: Heck, T. Year: 2007 Name of editors: Dones R. Title of anthology: Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0 Place of publicati… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].