====== Ventilation system, central, 1 x 720 m3/h, PE ducts, with GHE — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:ventilation_system_central_1_x_720_m3_h_pe_ducts_with_ghe__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Ventilation system, central, 1 x 720 m3/h, PE ducts, with GHE [CH], per 1 p. EF v3.1 climate change 7235 kg CO2 eq (Monte Carlo 95 % interval 6870–9310). Main contributors: Disposal, building, polyethylene/polypropylene products, to … 21 %; Spiral-seam duct, steel, DN 400, at plant 18 %; Ground heat exchanger, PE, DN 200, at plant 16 %; Ventilation equipment, central, 600-1200 m3/h, at plant 9 %; Air distribution housing, steel, 120 m3/h, at plant 6 %; Ventilation duct, PE corrugated tube, DN 75, at plant 6 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Ventilation system, central, 1 x 720 m3/h, PE ducts, with GHE | | Dataset UUID / graph id | ''%%6e9f60f5-635b-390a-9150-bfcdd7cf2a4b%%'' / ''%%activity:ventilation_system_central_1_x_720_m3_h_pe_ducts_with_ghe__ch%%'' | | Reference product, unit | Ventilation system, central, 1 x 720 m3/h, PE ducts, with GHE, 1 p | | Location | CH | | Time period | 2003-01/2003-12 | | Category | construction / ventilation\components\infrastructure | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Ventilation system for a multi family house. The house considered in the investigation includes 6 flats with 130 m2 floor area each and a ventilation rate of 120 m3/h. The influence of a smaller concrete demand due to embedment of ventilation tubes in the concrete of the floor (-4.86 kg concrete per m2 floor area) is not included.; UUID: 6e9f60f5-635b-390a-9150-bfcdd7cf2a4b This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Ventilation system, central, 1 x 720 m3/h, PE ducts, with GHE (CH). All results are given per unit of the reference flow. ==== System boundary ==== Materials used for the ventilation system. Transport of the components to the construction site. Disposal of the components included. Influence of ventilation ducts on building construction not included. No materials for renwal of components included. Operation of system not included. ==== Technology ==== Central ventilation system including 4 parallel polyethylene ground heat exchanger tubes (200 mm diameter). Air distribution from the central ventilation unit with a galvanised steel tube (400 mm diameter) to the distribution housings in the 6 flats. Distribution of fresh- and exhaust-air within the flat with polyethylene tubes (75 mm diameter). Exhaust air from the air collection housings in the 6 flats with a galvanised steel tube (400 mm diameter) to the central ventilation unit. Exhaust air from the ventilation unit to the outside air with a galvanised steel tube (400 mm diameter). ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Disposal, building, polyethylene/polypropylene products, to final disposal | technosphere | CH | 492 | kg | lognormal, GSD² 1.12 | — | 20.6 | ████ | | | Spiral-seam duct, steel, DN 400, at plant | technosphere | RER | 45 | m | lognormal, GSD² 1.12 | — | 17.6 | ████ | | | Ground heat exchanger, PE, DN 200, at plant | technosphere | RER | 120 | m | lognormal, GSD² 1.12 | — | 15.8 | ███ | | | Ventilation equipment, central, 600-1200 m3/h, at plant | technosphere | RER | 1 | p | lognormal, GSD² 1.12 | — | 9.0 | ██ | | | Air distribution housing, steel, 120 m3/h, at plant | technosphere | CH | 12 | p | lognormal, GSD² 1.12 | — | 5.9 | █ | | | Ventilation duct, PE corrugated tube, DN 75, at plant | technosphere | RER | 400 | m | lognormal, GSD² 1.12 | — | 5.8 | █ | | | Silencer, steel, DN 125, at plant | technosphere | CH | 12 | p | lognormal, GSD² 1.12 | — | 4.7 | █ | | | Supply air inlet, steel, SS, DN 75, at plant | technosphere | RER | 30 | p | lognormal, GSD² 1.12 | — | 3.9 | █ | | | Insulation spiral-seam duct, rockwool, DN 400, 30 mm, at plant | technosphere | RER | 20 | m | lognormal, GSD² 1.12 | — | 3.5 | █ | | | Outside air intake, stainless steel, DN 370, at plant | technosphere | RER | 1 | p | lognormal, GSD² 1.12 | — | 2.6 | █ | | | Silencer, steel, DN 315, 50 mm, at plant | technosphere | CH | 2 | p | lognormal, GSD² 1.12 | — | 1.7 | · | | | Spiral-seam duct, steel, DN 125, at plant | technosphere | RER | 12 | m | lognormal, GSD² 1.12 | — | 1.5 | · | | | Overflow element, steel, approx. 40 m3/h | technosphere | RER | 18 | p | lognormal, GSD² 1.12 | — | 1.2 | · | | | Transport, freight, lorry, 3.5t gross weight, fleet average | technosphere | CH | 70.5 | tkm | lognormal, GSD² 2.06 | — | 1.1 | · | | | Excavation, hydraulic digger, average | technosphere | CH | 137 | m3 | lognormal, GSD² 1.24 | — | 0.8 | · | | | Exhaust air roof hood, steel, DN 400, at plant | technosphere | CH | 1 | p | lognormal, GSD² 1.12 | — | 0.8 | · | | | Transport, freight, lorry, fleet average | technosphere | RER | 292 | tkm | lognormal, GSD² 2.02 | — | 0.8 | · | | | Sealing tape, aluminum/PE, 50 mm wide, at plant | technosphere | RER | 200 | m | lognormal, GSD² 1.12 | — | 0.6 | · | | | Exhaust air valve, in-wall housing, plastic/steel, DN 125, at plant | technosphere | CH | 18 | p | lognormal, GSD² 1.12 | — | 0.5 | · | | | Disposal, sealing tape, aluminum/PE, 50 mm wide | technosphere | CH | 200 | m | lognormal, GSD² 1.12 | — | 0.3 | · | | | Control and wiring, central unit, at plant | technosphere | RER | 1 | p | lognormal, GSD² 1.12 | — | 0.3 | · | | | Disposal, overflow element, steel, approx. 40 m3/h | technosphere | CH | 18 | p | lognormal, GSD² 1.12 | — | 0.2 | · | | | Flexible duct, aluminum/PET, DN of 125, at plant | technosphere | RER | 10 | m | lognormal, GSD² 1.12 | — | 0.1 | · | | | Disposal, air distribution housing, steel, 120 m3/h | technosphere | CH | 12 | p | lognormal, GSD² 1.12 | — | 0.1 | · | | | Disposal, outside air intake, stainless steel, DN 370 | technosphere | CH | 1 | p | lognormal, GSD² 1.12 | — | 0.1 | · | | | Air filter, in exhaust air valve, at plant | technosphere | RER | 18 | p | lognormal, GSD² 1.12 | — | 0.1 | · | | | Disposal, control and wiring, central unit | technosphere | CH | 1 | p | lognormal, GSD² 1.12 | — | 0.1 | · | | | Air filter, central unit, 600 m3/h, at plant | technosphere | RER | 2 | p | lognormal, GSD² 1.12 | — | 0.0 | · | | | Disposal, exhaust air valve, in-wall housing, plastic/steel, DN 125 | technosphere | CH | 18 | p | lognormal, GSD² 1.12 | — | 0.0 | · | | | Disposal, ventilation equipment, central, 600-1200 m3/h | technosphere | CH | 1 | p | lognormal, GSD² 1.12 | — | 0.0 | · | | | Disposal, flexible duct, aluminum/PET, DN of 125 | technosphere | CH | 10 | m | lognormal, GSD² 1.12 | — | 0.0 | · | | | Transport, freight, lorry, 16t-32t gross weight, fleet average | technosphere | CH | 8.84 | tkm | lognormal, GSD² 2.02 | — | 0.0 | · | | | Disposal, air filter, in exhaust air valve | technosphere | CH | 18 | p | lognormal, GSD² 1.12 | — | 0.0 | · | | | Disposal, building, bulk iron (excluding reinforcement), to sorting plant | technosphere | CH | 359 | kg | lognormal, GSD² 1.12 | — | 0.0 | · | | | Disposal, insulation spiral-seam duct, rockwool, DN 400, 30 mm | technosphere | CH | 20 | m | lognormal, GSD² 1.12 | — | 0.0 | · | | | Disposal, silencer, steel, DN 125 | technosphere | CH | 12 | p | lognormal, GSD² 1.12 | — | 0.0 | · | | | Disposal, silencer, steel, DN 315, 50 mm | technosphere | CH | 2 | p | lognormal, GSD² 1.12 | — | 0.0 | · | | | Disposal, air filter, central unit, 600 m3/h | technosphere | CH | 2 | p | lognormal, GSD² 1.12 | — | 0.0 | · | | | Disposal, exhaust air roof hood, steel, DN 400 | technosphere | CH | 1 | p | lognormal, GSD² 1.12 | — | 0.0 | · | | ==== Data quality ==== 0 of 39 direct exchanges carry a declared pedigree, 39 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | none | | sampling procedure | Questionnaire and assumptions. Data valid for example building used. | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: passed; Other validation: none; | | time period comment | Amount of material investigated in 2003 | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **92** | 57.65 | 180.3 | 1.78 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **11.38** | 7.602 | 27.42 | 1.93 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **7222** | 6855 | 9292 | 1.17 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2.485** | 2.099 | 4.029 | 1.39 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **7235** | 6870 | 9310 | 1.17 | | EF-particulate Matter | Impact on human health | disease incidence | **9.628e-04** | 7.052e-04 | 0.001679 | 1.54 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.755e+04** | 2.392e+04 | 5.716e+04 | 1.58 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **652.3** | 623.8 | 1247 | 1.53 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.82e+04** | 2.473e+04 | 5.886e+04 | 1.56 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **6.445** | 5.479 | 9.941 | 1.35 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **2.472** | 1.857 | 11.99 | 2.65 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **367.4** | 208.1 | 754.1 | 1.91 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.627e-06** | 2.473e-06 | 6.978e-06 | 1.68 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.112e-06** | 1.867e-06 | 4.639e-06 | 1.6 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **4.739e-06** | 4.681e-06 | 1.045e-05 | 1.49 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.381e-04** | 1.910e-04 | 7.335e-04 | 1.93 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **9.628e-06** | 6.568e-06 | 2.028e-05 | 1.79 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.477e-04** | 1.993e-04 | 7.424e-04 | 1.9 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **1268** | 486.1 | 7852 | 4.13 | | Land use | Soil quality index | pt (soil quality index) | **2.859e+04** | 2.675e+04 | 4.819e+04 | 1.36 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **1.931e-04** | 1.746e-04 | 2.902e-04 | 1.31 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **18.12** | 17.38 | 27.4 | 1.27 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **9.363e+04** | 7.697e+04 | 1.498e+05 | 1.41 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.1341** | -0.2902 | 0.9175 | — | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **471.5** | -9.272e+05 | 4.489e+05 | — | Climate change 7235 kg CO2 eq per p. Main contributors: Disposal, building, polyethylene/polypropylene products, to … 21 %; Spiral-seam duct, steel, DN 400, at plant 18 %; Ground heat exchanger, PE, DN 200, at plant 16 %; Ventilation equipment, central, 600-1200 m3/h, at plant 9 %; Air distribution housing, steel, 120 m3/h, at plant 6 %; Ventilation duct, PE corrugated tube, DN 75, at plant 6 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Disposal, building, polyethylene/polypropylene products, to … 21 %; Spiral-seam duct, steel, DN 400, at plant 18 %; Ground heat exchanger, PE, DN 200, at plant 16 %; Ventilation equipment, central, 600-1200 m3/h, at plant 9 %; Air distribution housing, steel, 120 m3/h, at plant 6 %; Ventilation duct, PE corrugated tube, DN 75, at plant 6 %. Most sensitive exchanges (Section 6.3): Disposal, building, polyethylene/polypropylene products, to final disposal [CH] (-2.2 / +2.4 %); Spiral-seam duct, steel, DN 400, at plant [RER] (-1.8 / +2.1 %); Ground heat exchanger, PE, DN 200, at plant [RER] (-1.7 / +1.9 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 92 | 94.27 | 0.976 | | Climate change-Biogenic | 11.38 | 11.38 | 1.000 | | Climate change-Fossil | 7222 | 7222 | 1.000 | | Climate change-Land use and land use change | 2.485 | 2.485 | 1.000 | | Climate change | 7235 | 7235 | 1.000 | | EF-particulate Matter | 9.628e-04 | 9.628e-04 | 1.000 | | Ecotoxicity, freshwater_inorganics | 2.755e+04 | 2.758e+04 | 0.999 | | Ecotoxicity, freshwater_organics | 652.3 | 646.6 | 1.009 | | Ecotoxicity, freshwater | 2.82e+04 | 2.82e+04 | 1.000 | | Eutrophication marine | 6.445 | 6.444 | 1.000 | | Eutrophication, freshwater | 2.472 | 2.472 | 1.000 | | Eutrophication, terrestrial | 367.4 | 369.6 | 0.994 | | Human toxicity, cancer_inorganics | 2.627e-06 | 2.612e-06 | 1.006 | | Human toxicity, cancer_organics | 2.112e-06 | 2.112e-06 | 1.000 | | Human toxicity, cancer | 4.739e-06 | 4.724e-06 | 1.003 | | Human toxicity, non-cancer_inorganics | 2.381e-04 | 2.375e-04 | 1.002 | | Human toxicity, non-cancer_organics | 9.628e-06 | 9.627e-06 | 1.000 | | Human toxicity, non-cancer | 2.477e-04 | 2.471e-04 | 1.002 | | Ionising radiation, human health | 1268 | 1268 | 1.000 | | Land use | 2.859e+04 | 2.189e+04 | 1.306 | | Ozone depletion | 1.931e-04 | 1.931e-04 | 1.000 | | Photochemical ozone formation - human health | 18.12 | 18.12 | 1.000 | | Resource use, fossils | 9.363e+04 | 9.365e+04 | 1.000 | | Resource use, minerals and metals | 0.1341 | 0.1314 | 1.021 | | Water use | 471.5 | 513.2 | 0.919 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 7235 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 1.604e+07 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Disposal, building, polyethylene/polypropylene products, to final disposal [CH] | 492 kg | ×0.895 / ×1.12 | lognormal, GSD² 1.12 | -2.2 / +2.4 | 2.4 (Climate change-Fossil) | | Spiral-seam duct, steel, DN 400, at plant [RER] | 45 m | ×0.895 / ×1.12 | lognormal, GSD² 1.12 | -1.8 / +2.1 | 5.6 (Eutrophication, terrestrial) | | Ground heat exchanger, PE, DN 200, at plant [RER] | 120 m | ×0.895 / ×1.12 | lognormal, GSD² 1.12 | -1.7 / +1.9 | 3.9 (Resource use, fossils) | | Ventilation equipment, central, 600-1200 m3/h, at plant [RER] | 1 p | ×0.895 / ×1.12 | lognormal, GSD² 1.12 | -0.9 / +1.1 | 2.1 (Eutrophication, freshwater) | | Transport, freight, lorry, 3.5t gross weight, fleet average [CH] | 70.5 tkm | ×0.493 / ×2.03 | lognormal, GSD² 2.06 | -0.5 / +1.1 | 6.3 (Ozone depletion) | | Air distribution housing, steel, 120 m3/h, at plant [CH] | 12 p | ×0.895 / ×1.12 | lognormal, GSD² 1.12 | -0.6 / +0.7 | 1.1 (EF-particulate Matter) | | Ventilation duct, PE corrugated tube, DN 75, at plant [RER] | 400 m | ×0.895 / ×1.12 | lognormal, GSD² 1.12 | -0.6 / +0.7 | 1.4 (Resource use, fossils) | | Transport, freight, lorry, fleet average [RER] | 292 tkm | ×0.502 / ×1.99 | lognormal, GSD² 2.02 | -0.4 / +0.8 | 8.5 (Climate change-Land use and land use change) | | Silencer, steel, DN 125, at plant [CH] | 12 p | ×0.895 / ×1.12 | lognormal, GSD² 1.12 | -0.5 / +0.6 | 1.6 (Human toxicity, cancer_organics) | | Supply air inlet, steel, SS, DN 75, at plant [RER] | 30 p | ×0.895 / ×1.12 | lognormal, GSD² 1.12 | -0.4 / +0.5 | 0.8 (Human toxicity, cancer_inorganics) | | Insulation spiral-seam duct, rockwool, DN 400, 30 mm, at plant [RER] | 20 m | ×0.895 / ×1.12 | lognormal, GSD² 1.12 | -0.4 / +0.4 | 1.1 (Climate change-Land use and land use change) | | Outside air intake, stainless steel, DN 370, at plant [RER] | 1 p | ×0.895 / ×1.12 | lognormal, GSD² 1.12 | -0.3 / +0.3 | 0.9 (Human toxicity, cancer_inorganics) | | Silencer, steel, DN 315, 50 mm, at plant [CH] | 2 p | ×0.895 / ×1.12 | lognormal, GSD² 1.12 | -0.2 / +0.2 | 0.6 (Human toxicity, cancer_organics) | | Excavation, hydraulic digger, average [CH] | 137 m3 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.2 / +0.2 | 0.7 (Human toxicity, non-cancer_organics) | | Spiral-seam duct, steel, DN 125, at plant [RER] | 12 m | ×0.895 / ×1.12 | lognormal, GSD² 1.12 | -0.2 / +0.2 | 0.5 (Eutrophication, terrestrial) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 7235 kg CO2 eq per p (95 % interval 6870–9310). Dominant contributors: Disposal, building, polyethylene/polypropylene products, to … 21 %; Spiral-seam duct, steel, DN 400, at plant 18 %; Ground heat exchanger, PE, DN 200, at plant 16 %; Ventilation equipment, central, 600-1200 m3/h, at plant 9 %; Air distribution housing, steel, 120 m3/h, at plant 6 %; Ventilation duct, PE corrugated tube, DN 75, at plant 6 %. Most sensitive: Disposal, building, polyethylene/polypropylene products, to final disposal [CH] (-2.2 / +2.4 %); Spiral-seam duct, steel, DN 400, at plant [RER] (-1.8 / +2.1 %); Ground heat exchanger, PE, DN 200, at plant [RER] (-1.7 / +1.9 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 5.1e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 23/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 39/39 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 7235 in [6870, 9310] | | time period declared | **PASS** | 2003-01/2003-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Hässig, W., Primas, A. (2007) Ökologische Aspekte der Komfortlüftungen im Wohnbereich. Final report ecoinvent Data v2.0. Volume: 25. Swiss Centre for LCI, B+H. Dübendorf and Zürich, CH. Type: Measurement on site Source: CD-ROM First author: Hässig, W. Other authors: Primas, A. Year: 2007 Title of anthology: Final report ecoinvent Data v2.0 Place of publication: Dübendorf and Zürich, CH Publisher: … — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].