====== Heat, at groundwater heat pump, brine-water, 15kW, cert. elec., in old building — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:heat_at_groundwater_heat_pump_brine_water_15kw_cert_elec_in_old_building__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Heat, at groundwater heat pump, brine-water, 15kW, cert. elec., in old building [CH], per 1 MJ. EF v3.1 climate change 0.003722 kg CO2 eq (Monte Carlo 95 % interval 0.003134–0.006153). Main contributors: Electricity, low voltage, certified electricity, at grid 34 %; Pentafluoroethane 25 %; Disposal, heat pump, brine-water, 15kW 15 %; Heat pump, brine-water, 15kW 15 %; Delivery and return well for groundwater heat pump, 9m, 7 %; Difluoromethane 5 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Heat, at groundwater heat pump, brine-water, 15kW, cert. elec., in old building | | Dataset UUID / graph id | ''%%6f05f241-dc25-321a-b426-d9375a047e3d%%'' / ''%%activity:heat_at_groundwater_heat_pump_brine_water_15kw_cert_elec_in_old_building__ch%%'' | | Reference product, unit | Heat, at groundwater heat pump, brine-water, 15kW, cert. elec., in old building, 1 MJ | | Location | CH — Data apply to the supply in Switzerland. | | Time period | 2019-01/2020-12 | | Category | heat / heat pumps\heating systems | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Heat from a brine-water heat pump, 15kW with heat source form groundwater, 9m deep and certified electricity mix (CH). Lifetime of the heating system is 20 years. SPF=3.2. Loss of coolant is 2% (of the total amount in the system) per year.; UUID: 6f05f241-dc25-321a-b426-d9375a047e3d This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 MJ** of Heat, at groundwater heat pump, brine-water, 15kW, cert. elec., in old building (CH). All results are given per unit of the reference flow. ==== System boundary ==== Included are the share of the production of the brine-water heatpump with a lifetime of 20years scaled for 1MJ. Also the the groundwater delivery and return with a lifetime of 20 years is part of this process. ==== Technology ==== undefined ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electricity, low voltage, certified electricity, at grid | technosphere | CH | 0.086806 | kWh | lognormal, GSD² 1.22 | — | 33.8 | ███████ | | | Disposal, heat pump, brine-water, 15kW | technosphere | CH | 4.4092e-07 | p | lognormal, GSD² 3.05 | — | 14.9 | ███ | | | Heat pump, brine-water, 15kW | technosphere | RER | 4.4092e-07 | p | lognormal, GSD² 3.05 | — | 14.5 | ███ | | | Delivery and return well for groundwater heat pump, 9m, | technosphere | CH | 4.4092e-07 | p | lognormal, GSD² 3.05 | — | 6.8 | █ | | | Trifluoromethane, at plant | technosphere | GLO | 2.4691e-07 | kg | lognormal, GSD² 2.29 | — | 0.1 | · | | | 1,1-difluoroethane, HFC-152a, at plant | technosphere | US | 2.4691e-07 | kg | lognormal, GSD² 2.29 | — | 0.0 | · | | | Pentafluoroethane | elementary | air/Ground level / Urban (>1000 people/s… | 2.4691e-07 | kg | lognormal, GSD² 1.56 | — | 24.8 | █████ | | | Difluoromethane | elementary | air/Ground level / Urban (>1000 people/s… | 2.4691e-07 | kg | lognormal, GSD² 1.56 | — | 5.1 | █ | | | Energy, Geothermal, Converted | elementary | natural resource | 0.74359 | MJ | lognormal, GSD² 1.22 | — | 0.0 | · | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 0.3125 | MJ | lognormal, GSD² 1.22 | — | 0.0 | · | | ==== Data quality ==== 0 of 10 direct exchanges carry a declared pedigree, 10 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Livia Waldburger (CARBOTECH); data entry: Thomas Kaegi (CARBOTECH); validation (proof reading): Andy Spoerri (EBP) | | extrapolations | none | | sampling procedure | heat efficieny based on literature | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: 19.02.2021; Other validation: Z:\Schreibtisch\WinShare\BAFU Heizsysteme\A_zum konvertieren\WP[EcoSpold_heat at groundwater heat pump_15-50kW_certified electricity mix_v0.1_lwa.xlsx]X-Process; | | time period comment | Time of publications. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 MJ. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **1.313e-05** | 8.193e-06 | 3.152e-05 | 2.02 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **7.803e-05** | 5.694e-05 | 1.212e-04 | 1.47 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.003574** | 0.002996 | 0.006006 | 1.42 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **7.036e-05** | 4.388e-05 | 1.132e-04 | 1.65 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.003722** | 0.003134 | 0.006153 | 1.41 | | EF-particulate Matter | Impact on human health | disease incidence | **1.048e-10** | 8.431e-11 | 2.339e-10 | 1.69 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.009074** | 0.00774 | 0.02769 | 1.96 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.903e-04** | 1.481e-04 | 5.657e-04 | 1.98 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.009264** | 0.007913 | 0.02823 | 1.95 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **2.065e-06** | 1.655e-06 | 4.887e-06 | 1.78 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **4.362e-06** | 2.329e-06 | 3.392e-05 | 3.92 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **2.437e-05** | 1.897e-05 | 5.099e-05 | 1.65 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.110e-12** | 1.654e-12 | 7.590e-12 | 2.21 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.140e-12** | 8.230e-13 | 2.229e-12 | 1.68 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **3.250e-12** | 2.619e-12 | 9.687e-12 | 1.92 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.406e-10** | 1.008e-10 | 6.020e-10 | 2.53 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.024e-11** | 5.460e-12 | 2.810e-11 | 2.39 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.509e-10** | 1.072e-10 | 6.379e-10 | 2.49 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **3.659e-04** | 1.429e-04 | 0.002811 | 4.59 | | Land use | Soil quality index | pt (soil quality index) | **0.04576** | 0.03041 | 0.08674 | 1.7 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **1.172e-09** | 4.434e-10 | 3.903e-09 | 3.19 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **6.955e-06** | 5.457e-06 | 1.540e-05 | 1.71 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.0173** | 0.01383 | 0.03988 | 1.73 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **2.723e-07** | 1.221e-07 | 9.699e-07 | 2.77 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **2.157e-04** | -2.947 | 1.339 | — | Climate change 0.003722 kg CO2 eq per MJ. Main contributors: Electricity, low voltage, certified electricity, at grid 34 %; Pentafluoroethane 25 %; Disposal, heat pump, brine-water, 15kW 15 %; Heat pump, brine-water, 15kW 15 %; Delivery and return well for groundwater heat pump, 9m, 7 %; Difluoromethane 5 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electricity, low voltage, certified electricity, at grid 34 %; Pentafluoroethane 25 %; Disposal, heat pump, brine-water, 15kW 15 %; Heat pump, brine-water, 15kW 15 %; Delivery and return well for groundwater heat pump, 9m, 7 %; Difluoromethane 5 %. Most sensitive exchanges (Section 6.3): Disposal, heat pump, brine-water, 15kW [CH] (-9.9 / +29.5 %); Heat pump, brine-water, 15kW [RER] (-9.7 / +28.8 %); Pentafluoroethane [air/Ground level / Urban (>1000 people/square mile)] (-8.8 / +13.5 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 1.313e-05 | 1.517e-05 | 0.865 | | Climate change-Biogenic | 7.803e-05 | 7.803e-05 | 1.000 | | Climate change-Fossil | 0.003574 | 0.003574 | 1.000 | | Climate change-Land use and land use change | 7.036e-05 | 7.036e-05 | 1.000 | | Climate change | 0.003722 | 0.003722 | 1.000 | | EF-particulate Matter | 1.048e-10 | 1.048e-10 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.009074 | 0.009454 | 0.960 | | Ecotoxicity, freshwater_organics | 1.903e-04 | 1.789e-04 | 1.064 | | Ecotoxicity, freshwater | 0.009264 | 0.009573 | 0.968 | | Eutrophication marine | 2.065e-06 | 2.065e-06 | 1.000 | | Eutrophication, freshwater | 4.362e-06 | 4.362e-06 | 1.000 | | Eutrophication, terrestrial | 2.437e-05 | 2.462e-05 | 0.990 | | Human toxicity, cancer_inorganics | 2.110e-12 | 2.103e-12 | 1.004 | | Human toxicity, cancer_organics | 1.140e-12 | 1.140e-12 | 1.000 | | Human toxicity, cancer | 3.250e-12 | 3.243e-12 | 1.002 | | Human toxicity, non-cancer_inorganics | 1.406e-10 | 1.402e-10 | 1.003 | | Human toxicity, non-cancer_organics | 1.024e-11 | 1.024e-11 | 1.000 | | Human toxicity, non-cancer | 1.509e-10 | 1.504e-10 | 1.003 | | Ionising radiation, human health | 3.659e-04 | 3.659e-04 | 1.000 | | Land use | 0.04576 | 0.03438 | 1.331 | | Ozone depletion | 1.172e-09 | 1.172e-09 | 1.000 | | Photochemical ozone formation - human health | 6.955e-06 | 6.955e-06 | 1.000 | | Resource use, fossils | 0.0173 | 0.01731 | 1.000 | | Resource use, minerals and metals | 2.723e-07 | 2.717e-07 | 1.002 | | Water use | 2.157e-04 | 2.367e-04 | 0.911 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.003717 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 12.81 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Disposal, heat pump, brine-water, 15kW [CH] | 4.409e-07 p | ×0.335 / ×2.98 | lognormal, GSD² 3.05 | -9.9 / +29.5 | 30.7 (Climate change-Fossil) | | Heat pump, brine-water, 15kW [RER] | 4.409e-07 p | ×0.335 / ×2.98 | lognormal, GSD² 3.05 | -9.7 / +28.8 | 137.7 (Ozone depletion) | | Pentafluoroethane [air/Ground level / Urban (>1000 people/square mile)] | 2.469e-07 kg | ×0.647 / ×1.55 | lognormal, GSD² 1.56 | -8.8 / +13.5 | 14.1 (Climate change-Fossil) | | Delivery and return well for groundwater heat pump, 9m, [CH] | 4.409e-07 p | ×0.335 / ×2.98 | lognormal, GSD² 3.05 | -4.5 / +13.4 | 30.2 (Water use) | | Electricity, low voltage, certified electricity, at grid [CH] | 0.08681 kWh | ×0.826 / ×1.21 | lognormal, GSD² 1.22 | -5.9 / +7.1 | 21.0 (Climate change-Land use and land use change) | | Difluoromethane [air/Ground level / Urban (>1000 people/square mile)] | 2.469e-07 kg | ×0.647 / ×1.55 | lognormal, GSD² 1.56 | -1.8 / +2.8 | 2.9 (Climate change-Fossil) | | Trifluoromethane, at plant [GLO] | 2.469e-07 kg | ×0.445 / ×2.25 | lognormal, GSD² 2.29 | -0.0 / +0.1 | 33.7 (Ozone depletion) | | 1,1-difluoroethane, HFC-152a, at plant [US] | 2.469e-07 kg | ×0.445 / ×2.25 | lognormal, GSD² 2.29 | -0.0 / +0.0 | 0.2 (Ionising radiation, human health) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.003722 kg CO2 eq per MJ (95 % interval 0.003134–0.006153). Dominant contributors: Electricity, low voltage, certified electricity, at grid 34 %; Pentafluoroethane 25 %; Disposal, heat pump, brine-water, 15kW 15 %; Heat pump, brine-water, 15kW 15 %; Delivery and return well for groundwater heat pump, 9m, 7 %; Difluoromethane 5 %. Most sensitive: Disposal, heat pump, brine-water, 15kW [CH] (-9.9 / +29.5 %); Heat pump, brine-water, 15kW [RER] (-9.7 / +28.8 %); Pentafluoroethane [air/Ground level / Urban (>1000 people/square mile)] (-8.8 / +13.5 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 MJ | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.9e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 10/10 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.003722 in [0.003134, 0.006153] | | time period declared | **PASS** | 2019-01/2020-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Kägi Thomas, Livia Waldburger, Cyril Kern, Gavin Roberts, Mischa Zschokke, Flora Conte, Lea Weber (2020) LCI of heating systems. Carbotech im Auftrag des BAFU. Carbotech AG. Zürich. CH. Type: Separate publication Source: Report First author: Kägi Thomas Other authors: Livia Waldburger, Cyril Kern, Gavin Roberts, Mischa Zschokke, Flora Conte, Lea Weber Year: 2020 Title of anthology: Carbotech im Au… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].