====== xxx Electricity, medium voltage, residual mix — BE ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:xxx_electricity_medium_voltage_residual_mix__be|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset xxx Electricity, medium voltage, residual mix [BE], per 1 kWh. EF v3.1 climate change 0.2512 kg CO2 eq (Monte Carlo 95 % interval 0.2249–0.4011). Main contributors: xxx Electricity, high voltage, residual mix 99 %; Sulfur hexafluoride 1 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | xxx Electricity, medium voltage, residual mix | | Dataset UUID / graph id | ''%%827f7ddf-34c7-3a9b-8387-7390842280db%%'' / ''%%activity:xxx_electricity_medium_voltage_residual_mix__be%%'' | | Reference product, unit | xxx Electricity, medium voltage, residual mix, 1 kWh | | Location | BE — undefined | | Time period | 2018-01/2018-12 | | Category | electricity / notMaintained | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== This dataset describes the transformation from high to medium voltage as well as the transmission of electricity at medium voltage. Time period: Time of publications. Version: 1 Energy values: Undefined Local category: Elektrizität Local subcategory: Erzeugungsmix UVEK 2022 source file:726-Strommixe-EU_v0.8._X-Residual Mix Distribution.xml UUID: 827f7ddf-34c7-3a9b-8387-7390842280db This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kWh** of xxx Electricity, medium voltage, residual mix (BE). All results are given per unit of the reference flow. ==== System boundary ==== Included are the electricity production in BE, the transmission network and direct SF6-emissions to air. Electricity losses during medium-voltage transmission and transformation from high-voltage are accounted for. ==== Technology ==== undefined ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | xxx Electricity, high voltage, residual mix | technosphere | BE | 1.0066 | kWh | lognormal, GSD² 1.13 | — | 98.6 | ████████████████████ | | | Transmission network, electricity, medium voltage | technosphere | CH | 1.8628e-08 | km | lognormal, GSD² 3.28 | — | 0.2 | · | | | Sulphur hexafluoride, liquid, at plant | technosphere | RER | 1.1591e-07 | kg | lognormal, GSD² 1.25 | — | 0.0 | · | | | Sulfur hexafluoride | elementary | air/Unknown | 1.1591e-07 | kg | lognormal, GSD² 1.58 | — | 1.2 | · | | | Waste Heat | elementary | air/Unknown | 0.022617 | MJ | lognormal, GSD² 1.24 | — | 0.0 | · | | | Waste Heat | elementary | soil/Unknown | 0.0011904 | MJ | lognormal, GSD² 1.24 | — | 0.0 | · | | ==== Data quality ==== 0 of 6 direct exchanges carry a declared pedigree, 6 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Luana Krebs (TREEZE); data entry: Luana Krebs (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | | | sampling procedure | | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: 10.02.2021; Other validation: G:\Projekte laufend\726 Umweltbilanz Strommix Schweiz 2018\EcoSpold[726-Strommixe-EU_v0.8.xlsx]X-Process; | | time period comment | Time of publications. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **1.990e-04** | 1.922e-04 | 4.261e-04 | 1.5 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.481e-04** | 1.044e-04 | 6.531e-04 | 2.56 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.251** | 0.2247 | 0.4004 | 1.35 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **3.565e-05** | 3.152e-05 | 7.858e-05 | 1.6 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.2512** | 0.2249 | 0.4011 | 1.35 | | EF-particulate Matter | Impact on human health | disease incidence | **4.850e-09** | 4.086e-09 | 8.884e-09 | 1.5 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.7084** | 0.5398 | 2.851 | 2.4 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.01885** | 0.01523 | 0.06864 | 2.16 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.7273** | 0.5587 | 2.89 | 2.38 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **1.274e-04** | 1.230e-04 | 2.314e-04 | 1.39 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **1.335e-05** | 1.144e-05 | 7.721e-05 | 2.68 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **7.782e-04** | 7.333e-04 | 0.001604 | 1.51 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.542e-11** | 1.609e-11 | 4.891e-11 | 1.74 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **4.721e-11** | 3.327e-11 | 9.104e-11 | 1.69 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **6.263e-11** | 5.317e-11 | 1.256e-10 | 1.54 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.638e-10** | 9.008e-10 | 2.524e-09 | 1.66 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **6.612e-11** | 5.828e-11 | 1.775e-10 | 1.76 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **8.299e-10** | 9.711e-10 | 2.661e-09 | 1.65 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.6445** | 0.2208 | 3.566 | 4.27 | | Land use | Soil quality index | pt (soil quality index) | **2.545** | 1.755 | 4.446 | 1.61 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **1.195e-08** | 9.718e-09 | 2.845e-08 | 1.7 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **4.937e-04** | 4.456e-04 | 0.001166 | 1.67 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **9.632** | 8.433 | 17.17 | 1.44 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **3.696e-07** | 3.471e-07 | 7.729e-07 | 1.5 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.06154** | -16.64 | 8.769 | — | Climate change 0.2512 kg CO2 eq per kWh. Main contributors: xxx Electricity, high voltage, residual mix 99 %; Sulfur hexafluoride 1 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: xxx Electricity, high voltage, residual mix 99 %; Sulfur hexafluoride 1 %. Most sensitive exchanges (Section 6.3): xxx Electricity, high voltage, residual mix [BE] (-11.1 / +12.5 %); Sulfur hexafluoride [air/Unknown] (-0.4 / +0.7 %); Transmission network, electricity, medium voltage [CH] (-0.2 / +0.5 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh: ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 1.990e-04 | 2.821e-04 | 0.706 | | Climate change-Biogenic | 1.481e-04 | 1.454e-04 | 1.018 | | Climate change-Fossil | 0.251 | 0.2503 | 1.003 | | Climate change-Land use and land use change | 3.565e-05 | 3.538e-05 | 1.008 | | Climate change | 0.2512 | 0.2505 | 1.003 | | EF-particulate Matter | 4.850e-09 | 4.830e-09 | 1.004 | | Ecotoxicity, freshwater_inorganics | 0.7084 | 0.7256 | 0.976 | | Ecotoxicity, freshwater_organics | 0.01885 | 0.01878 | 1.003 | | Ecotoxicity, freshwater | 0.7273 | 0.744 | 0.977 | | Eutrophication marine | 1.274e-04 | 1.264e-04 | 1.008 | | Eutrophication, freshwater | 1.335e-05 | 1.326e-05 | 1.007 | | Eutrophication, terrestrial | 7.782e-04 | 0.001127 | 0.691 | | Human toxicity, cancer_inorganics | 1.542e-11 | 1.468e-11 | 1.051 | | Human toxicity, cancer_organics | 4.721e-11 | 4.709e-11 | 1.003 | | Human toxicity, cancer | 6.263e-11 | 6.177e-11 | 1.014 | | Human toxicity, non-cancer_inorganics | 7.638e-10 | 7.141e-10 | 1.069 | | Human toxicity, non-cancer_organics | 6.612e-11 | 6.683e-11 | 0.989 | | Human toxicity, non-cancer | 8.299e-10 | 7.810e-10 | 1.063 | | Ionising radiation, human health | 0.6445 | 0.6444 | 1.000 | | Land use | 2.545 | 2.139 | 1.190 | | Ozone depletion | 1.195e-08 | 1.189e-08 | 1.005 | | Photochemical ozone formation - human health | 4.937e-04 | 4.983e-04 | 0.991 | | Resource use, fossils | 9.632 | 9.617 | 1.002 | | Resource use, minerals and metals | 3.696e-07 | 3.539e-07 | 1.044 | | Water use | 0.06154 | 0.0615 | 1.001 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.2503 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 646.9 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | xxx Electricity, high voltage, residual mix [BE] | 1.007 kWh | ×0.888 / ×1.13 | lognormal, GSD² 1.13 | -11.1 / +12.5 | 12.6 (Ionising radiation, human health) | | Sulfur hexafluoride [air/Unknown] | 1.159e-07 kg | ×0.637 / ×1.57 | lognormal, GSD² 1.58 | -0.4 / +0.7 | 0.7 (Climate change-Fossil) | | Transmission network, electricity, medium voltage [CH] | 1.863e-08 km | ×0.312 / ×3.21 | lognormal, GSD² 3.28 | -0.2 / +0.5 | 92.9 (Human toxicity, cancer_inorganics) | | Sulphur hexafluoride, liquid, at plant [RER] | 1.159e-07 kg | ×0.803 / ×1.24 | lognormal, GSD² 1.25 | -0.0 / +0.0 | 0.0 (Climate change-Fossil) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== ^ Source ^ Scope ^ Value ^ This dataset ^ Ratio ^ Note ^ | bafu | xxx Electricity, medium voltage, residual mix [AT] | 0.004437 kg CO2 eq | 0.2512 | 56.61 | same dataset name, other location | | bafu | xxx Electricity, medium voltage, residual mix [FR] | 0.07251 kg CO2 eq | 0.2512 | 3.46 | same dataset name, other location | | bafu | xxx Electricity, medium voltage, residual mix [SE] | 0.07718 kg CO2 eq | 0.2512 | 3.25 | same dataset name, other location | | bafu | xxx Electricity, medium voltage, residual mix [SK] | 0.2274 kg CO2 eq | 0.2512 | 1.10 | same dataset name, other location | | bafu | xxx Electricity, medium voltage, residual mix [LV] | 0.3012 kg CO2 eq | 0.2512 | 0.83 | same dataset name, other location | | bafu | xxx Electricity, medium voltage, residual mix [CZ] | 0.6885 kg CO2 eq | 0.2512 | 0.36 | same dataset name, other location | | bafu | xxx Electricity, medium voltage, residual mix [MT] | 0.7968 kg CO2 eq | 0.2512 | 0.32 | same dataset name, other location | | bafu | xxx Electricity, medium voltage, residual mix [DE] | 0.8093 kg CO2 eq | 0.2512 | 0.31 | same dataset name, other location | | bafu | xxx Electricity, medium voltage, residual mix [CY] | 0.9228 kg CO2 eq | 0.2512 | 0.27 | same dataset name, other location | | bafu | xxx Electricity, medium voltage, residual mix [PL] | 1.026 kg CO2 eq | 0.2512 | 0.24 | same dataset name, other location | ==== Conclusions and limitations ==== GWP100 0.2512 kg CO2 eq per kWh (95 % interval 0.2249–0.4011). Dominant contributors: xxx Electricity, high voltage, residual mix 99 %; Sulfur hexafluoride 1 %. Most sensitive: xxx Electricity, high voltage, residual mix [BE] (-11.1 / +12.5 %); Sulfur hexafluoride [air/Unknown] (-0.4 / +0.7 %); Transmission network, electricity, medium voltage [CH] (-0.2 / +0.5 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kWh | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.8e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | **PASS** | graph / published = 1.003; categories within ±5 %: 19/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 6/6 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.2512 in [0.2249, 0.4011] | | time period declared | **PASS** | 2018-01/2018-12 | | geography is a known location code | **PASS** | BE | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Krebs L., Stolz P., Frischknecht R. (2020) Umweltbilanz Strommix Schweiz 2018. Project reports. Volume: 723. treeze Ltd.. Uster, CH. Type: Separate publication First author: Krebs L. Other authors: Stolz P., Frischknecht R. Year: 2020 Title of anthology: Project reports Place of publication: Uster, CH Publisher: treeze Ltd. Volume No: 723 — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].