====== Electricity, photovoltaic mix facade, at plant — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:electricity_photovoltaic_mix_facade_at_plant__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity, photovoltaic mix facade, at plant [CH], per 1 kWh. EF v3.1 climate change 0.04669 kg CO2 eq (Monte Carlo 95 % interval 0.0403–0.09405). Main contributors: Electricity, PV, at 3kWp facade installation, multi-Si, pane… 45 %; Electricity, PV, at 3kWp facade installation, single-Si, pan… 24 %; Electricity, PV, at 3kWp facade, multi-Si, laminated, integr… 20 %; Electricity, PV, at 3kWp facade, single-Si, laminated, integ… 11 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Electricity, photovoltaic mix facade, at plant | | Dataset UUID / graph id | ''%%85b2378e-5b5b-303f-ba28-36226a6b1464%%'' / ''%%activity:electricity_photovoltaic_mix_facade_at_plant__ch%%'' | | Reference product, unit | Electricity, photovoltaic mix facade, at plant, 1 kWh | | Location | CH | | Time period | 2005-01/2018-12 | | Category | energy supply, kbob recommendation / electricity, delivered via network | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== UUID: 85b2378e-5b5b-303f-ba28-36226a6b1464 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kWh** of Electricity, photovoltaic mix facade, at plant (CH). All results are given per unit of the reference flow. ==== System boundary ==== This data set describes the share of the different facade PV technologies ==== Technology ==== — ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electricity, PV, at 3kWp facade installation, multi-Si, panel, mounted | technosphere | CH | 0.43584 | kWh | lognormal, GSD² 1.05 | — | 45.2 | █████████ | | | Electricity, PV, at 3kWp facade installation, single-Si, panel, mounted | technosphere | CH | 0.23082 | kWh | lognormal, GSD² 1.05 | — | 23.7 | █████ | | | Electricity, PV, at 3kWp facade, multi-Si, laminated, integrated | technosphere | CH | 0.21792 | kWh | lognormal, GSD² 1.05 | — | 20.3 | ████ | | | Electricity, PV, at 3kWp facade, single-Si, laminated, integrated | technosphere | CH | 0.11541 | kWh | lognormal, GSD² 1.05 | — | 10.8 | ██ | | ==== Data quality ==== 0 of 4 direct exchanges carry a declared pedigree, 4 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Rolf Frischknecht (TREEZE); data entry: Rolf Frischknecht (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | none | | sampling procedure | unknown | | production volume | unknown | | uncertainty adjustments | none | | validation details | 12.09.2023 | | time period comment | Time of publications. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **2.288e-04** | 2.085e-04 | 4.182e-04 | 1.42 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2.114e-04** | 1.353e-04 | 6.863e-04 | 2.28 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.04645** | 0.04011 | 0.09314 | 1.54 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2.786e-05** | 2.335e-05 | 5.168e-05 | 1.51 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.04669** | 0.0403 | 0.09405 | 1.54 | | EF-particulate Matter | Impact on human health | disease incidence | **1.721e-09** | 1.579e-09 | 8.848e-09 | 2.34 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.3039** | 0.2857 | 0.7969 | 1.69 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.006064** | 0.005783 | 0.01345 | 1.58 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.3099** | 0.2916 | 0.8102 | 1.68 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **6.097e-05** | 5.319e-05 | 1.317e-04 | 1.54 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **7.020e-05** | 4.754e-05 | 4.405e-04 | 3.09 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **4.570e-04** | 4.174e-04 | 9.196e-04 | 1.48 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.675e-11** | 2.726e-11 | 7.968e-11 | 1.79 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.254e-11** | 1.082e-11 | 3.014e-11 | 1.68 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **3.929e-11** | 4.109e-11 | 1.044e-10 | 1.66 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.804e-09** | 1.817e-09 | 5.206e-09 | 1.77 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **8.541e-11** | 6.791e-11 | 1.602e-10 | 1.58 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.889e-09** | 1.896e-09 | 5.323e-09 | 1.74 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.01156** | 0.004064 | 0.09536 | 4.97 | | Land use | Soil quality index | pt (soil quality index) | **0.3519** | 0.3074 | 0.8184 | 1.63 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **1.831e-09** | 1.588e-09 | 4.032e-09 | 1.57 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **1.569e-04** | 1.456e-04 | 3.127e-04 | 1.46 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.6253** | 0.5427 | 1.357 | 1.57 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **7.962e-06** | 6.412e-06 | 1.178e-05 | 1.37 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.02318** | -13.3 | 6.811 | — | Climate change 0.04669 kg CO2 eq per kWh. Main contributors: Electricity, PV, at 3kWp facade installation, multi-Si, pane… 45 %; Electricity, PV, at 3kWp facade installation, single-Si, pan… 24 %; Electricity, PV, at 3kWp facade, multi-Si, laminated, integr… 20 %; Electricity, PV, at 3kWp facade, single-Si, laminated, integ… 11 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electricity, PV, at 3kWp facade installation, multi-Si, pane… 45 %; Electricity, PV, at 3kWp facade installation, single-Si, pan… 24 %; Electricity, PV, at 3kWp facade, multi-Si, laminated, integr… 20 %; Electricity, PV, at 3kWp facade, single-Si, laminated, integ… 11 %. Most sensitive exchanges (Section 6.3): Electricity, PV, at 3kWp facade installation, multi-Si, panel, mounted [CH] (-2.1 / +2.2 %); Electricity, PV, at 3kWp facade installation, single-Si, panel, mounted [CH] (-1.1 / +1.2 %); Electricity, PV, at 3kWp facade, multi-Si, laminated, integrated [CH] (-1.0 / +1.0 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh: ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 2.288e-04 | 2.429e-04 | 0.942 | | Climate change-Biogenic | 2.114e-04 | 2.114e-04 | 1.000 | | Climate change-Fossil | 0.04645 | 0.04645 | 1.000 | | Climate change-Land use and land use change | 2.786e-05 | 2.786e-05 | 1.000 | | Climate change | 0.04669 | 0.04669 | 1.000 | | EF-particulate Matter | 1.721e-09 | 1.721e-09 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.3039 | 0.3132 | 0.970 | | Ecotoxicity, freshwater_organics | 0.006064 | 0.005102 | 1.189 | | Ecotoxicity, freshwater | 0.3099 | 0.3161 | 0.981 | | Eutrophication marine | 6.097e-05 | 6.097e-05 | 1.000 | | Eutrophication, freshwater | 7.020e-05 | 7.020e-05 | 1.000 | | Eutrophication, terrestrial | 4.570e-04 | 4.741e-04 | 0.964 | | Human toxicity, cancer_inorganics | 2.675e-11 | 2.660e-11 | 1.006 | | Human toxicity, cancer_organics | 1.254e-11 | 1.254e-11 | 1.000 | | Human toxicity, cancer | 3.929e-11 | 3.914e-11 | 1.004 | | Human toxicity, non-cancer_inorganics | 1.804e-09 | 1.793e-09 | 1.006 | | Human toxicity, non-cancer_organics | 8.541e-11 | 8.537e-11 | 1.000 | | Human toxicity, non-cancer | 1.889e-09 | 1.879e-09 | 1.006 | | Ionising radiation, human health | 0.01156 | 0.01156 | 1.000 | | Land use | 0.3519 | 0.2885 | 1.220 | | Ozone depletion | 1.831e-09 | 1.831e-09 | 1.000 | | Photochemical ozone formation - human health | 1.569e-04 | 1.569e-04 | 1.000 | | Resource use, fossils | 0.6253 | 0.6255 | 1.000 | | Resource use, minerals and metals | 7.962e-06 | 7.938e-06 | 1.003 | | Water use | 0.02318 | 0.02313 | 1.002 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.04665 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 131.7 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Electricity, PV, at 3kWp facade installation, multi-Si, panel, mounted [CH] | 0.4358 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -2.1 / +2.2 | 2.3 (Climate change-Land use and land use change) | | Electricity, PV, at 3kWp facade installation, single-Si, panel, mounted [CH] | 0.2308 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -1.1 / +1.2 | 1.9 (Water use) | | Electricity, PV, at 3kWp facade, multi-Si, laminated, integrated [CH] | 0.2179 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -1.0 / +1.0 | 1.1 (Resource use, minerals and metals) | | Electricity, PV, at 3kWp facade, single-Si, laminated, integrated [CH] | 0.1154 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.5 / +0.5 | 0.9 (Water use) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.04669 kg CO2 eq per kWh (95 % interval 0.0403–0.09405). Dominant contributors: Electricity, PV, at 3kWp facade installation, multi-Si, pane… 45 %; Electricity, PV, at 3kWp facade installation, single-Si, pan… 24 %; Electricity, PV, at 3kWp facade, multi-Si, laminated, integr… 20 %; Electricity, PV, at 3kWp facade, single-Si, laminated, integ… 11 %. Most sensitive: Electricity, PV, at 3kWp facade installation, multi-Si, panel, mounted [CH] (-2.1 / +2.2 %); Electricity, PV, at 3kWp facade installation, single-Si, panel, mounted [CH] (-1.1 / +1.2 %); Electricity, PV, at 3kWp facade, multi-Si, laminated, integrated [CH] (-1.0 / +1.0 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kWh | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.1e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 22/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 4/4 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.04669 in [0.0403, 0.09405] | | time period declared | **PASS** | 2005-01/2018-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Report — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].