====== xxx Electricity, medium voltage, residual mix — SK ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:xxx_electricity_medium_voltage_residual_mix__sk|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset xxx Electricity, medium voltage, residual mix [SK], per 1 kWh. EF v3.1 climate change 0.2274 kg CO2 eq (Monte Carlo 95 % interval 0.2086–0.2764). Main contributors: xxx Electricity, high voltage, residual mix 98 %; Sulfur hexafluoride 1 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | xxx Electricity, medium voltage, residual mix | | Dataset UUID / graph id | ''%%872f686f-5f80-3af4-b449-f990fb5d659d%%'' / ''%%activity:xxx_electricity_medium_voltage_residual_mix__sk%%'' | | Reference product, unit | xxx Electricity, medium voltage, residual mix, 1 kWh | | Location | SK — undefined | | Time period | 2018-01/2018-12 | | Category | electricity / notMaintained | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== This dataset describes the transformation from high to medium voltage as well as the transmission of electricity at medium voltage. Time period: Time of publications. Version: 1 Energy values: Undefined Local category: Elektrizität Local subcategory: Erzeugungsmix UVEK 2022 source file:726-Strommixe-EU_v0.8._X-Residual Mix Distribution.xml UUID: 872f686f-5f80-3af4-b449-f990fb5d659d This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kWh** of xxx Electricity, medium voltage, residual mix (SK). All results are given per unit of the reference flow. ==== System boundary ==== Included are the electricity production in SK, the transmission network and direct SF6-emissions to air. Electricity losses during medium-voltage transmission and transformation from high-voltage are accounted for. ==== Technology ==== undefined ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | xxx Electricity, high voltage, residual mix | technosphere | SK | 1.0051 | kWh | lognormal, GSD² 1.13 | — | 98.5 | ████████████████████ | | | Transmission network, electricity, medium voltage | technosphere | CH | 1.8628e-08 | km | lognormal, GSD² 3.28 | — | 0.3 | · | | | Sulphur hexafluoride, liquid, at plant | technosphere | RER | 1.1543e-07 | kg | lognormal, GSD² 1.25 | — | 0.0 | · | | | Sulfur hexafluoride | elementary | air/Unknown | 1.1543e-07 | kg | lognormal, GSD² 1.58 | — | 1.3 | · | | | Waste Heat | elementary | soil/Unknown | 9.2330e-04 | MJ | lognormal, GSD² 1.24 | — | 0.0 | · | | | Waste Heat | elementary | air/Unknown | 0.017543 | MJ | lognormal, GSD² 1.24 | — | 0.0 | · | | ==== Data quality ==== 0 of 6 direct exchanges carry a declared pedigree, 6 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Luana Krebs (TREEZE); data entry: Luana Krebs (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | | | sampling procedure | | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: 10.02.2021; Other validation: G:\Projekte laufend\726 Umweltbilanz Strommix Schweiz 2018\EcoSpold[726-Strommixe-EU_v0.8.xlsx]X-Process; | | time period comment | Time of publications. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **3.178e-04** | 2.989e-04 | 4.098e-04 | 1.17 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2.210e-04** | 1.803e-04 | 4.186e-04 | 1.54 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.2267** | 0.2081 | 0.2756 | 1.15 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **4.468e-04** | 2.367e-04 | 9.433e-04 | 2 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.2274** | 0.2086 | 0.2764 | 1.15 | | EF-particulate Matter | Impact on human health | disease incidence | **8.045e-09** | 6.463e-09 | 1.260e-08 | 1.43 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.672** | 0.5565 | 1.352 | 1.55 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.007176** | 0.00625 | 0.01842 | 1.73 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.6792** | 0.5648 | 1.364 | 1.55 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **2.012e-04** | 1.851e-04 | 2.537e-04 | 1.17 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **2.497e-04** | 9.976e-05 | 8.553e-04 | 2.98 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **9.013e-04** | 8.395e-04 | 0.001223 | 1.21 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **4.152e-11** | 4.369e-11 | 1.231e-10 | 1.71 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.006e-10** | 6.054e-11 | 1.818e-10 | 1.75 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.421e-10** | 1.222e-10 | 2.745e-10 | 1.52 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.064e-09** | 2.152e-09 | 5.712e-09 | 1.65 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.403e-11** | 4.875e-11 | 9.759e-11 | 1.41 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.118e-09** | 2.215e-09 | 5.790e-09 | 1.64 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.8569** | 0.2925 | 4.684 | 4.28 | | Land use | Soil quality index | pt (soil quality index) | **5.281** | 3.283 | 9.089 | 1.69 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **7.601e-09** | 5.629e-09 | 1.413e-08 | 1.63 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **4.677e-04** | 4.337e-04 | 6.633e-04 | 1.24 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **10.13** | 8.728 | 13.3 | 1.24 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **2.105e-07** | 1.774e-07 | 4.549e-07 | 1.62 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.09695** | -210.1 | 102.7 | — | Climate change 0.2274 kg CO2 eq per kWh. Main contributors: xxx Electricity, high voltage, residual mix 98 %; Sulfur hexafluoride 1 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: xxx Electricity, high voltage, residual mix 98 %; Sulfur hexafluoride 1 %. Most sensitive exchanges (Section 6.3): xxx Electricity, high voltage, residual mix [SK] (-11.0 / +12.4 %); Sulfur hexafluoride [air/Unknown] (-0.5 / +0.7 %); Transmission network, electricity, medium voltage [CH] (-0.2 / +0.6 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh: ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 3.178e-04 | 9.432e-04 | 0.337 | | Climate change-Biogenic | 2.210e-04 | 2.204e-04 | 1.002 | | Climate change-Fossil | 0.2267 | 0.2266 | 1.001 | | Climate change-Land use and land use change | 4.468e-04 | 4.468e-04 | 1.000 | | Climate change | 0.2274 | 0.2272 | 1.001 | | EF-particulate Matter | 8.045e-09 | 8.041e-09 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.672 | 0.716 | 0.939 | | Ecotoxicity, freshwater_organics | 0.007176 | 0.007072 | 1.015 | | Ecotoxicity, freshwater | 0.6792 | 0.7229 | 0.940 | | Eutrophication marine | 2.012e-04 | 2.009e-04 | 1.001 | | Eutrophication, freshwater | 2.497e-04 | 2.497e-04 | 1.000 | | Eutrophication, terrestrial | 9.013e-04 | 0.001435 | 0.628 | | Human toxicity, cancer_inorganics | 4.152e-11 | 3.315e-11 | 1.252 | | Human toxicity, cancer_organics | 1.006e-10 | 1.006e-10 | 1.000 | | Human toxicity, cancer | 1.421e-10 | 1.337e-10 | 1.063 | | Human toxicity, non-cancer_inorganics | 2.064e-09 | 1.792e-09 | 1.152 | | Human toxicity, non-cancer_organics | 5.403e-11 | 5.417e-11 | 0.998 | | Human toxicity, non-cancer | 2.118e-09 | 1.846e-09 | 1.147 | | Ionising radiation, human health | 0.8569 | 0.8569 | 1.000 | | Land use | 5.281 | 4.249 | 1.243 | | Ozone depletion | 7.601e-09 | 7.589e-09 | 1.002 | | Photochemical ozone formation - human health | 4.677e-04 | 4.686e-04 | 0.998 | | Resource use, fossils | 10.13 | 10.13 | 1.000 | | Resource use, minerals and metals | 2.105e-07 | 2.052e-07 | 1.025 | | Water use | 0.09695 | 0.1048 | 0.925 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.2271 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 722.2 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | xxx Electricity, high voltage, residual mix [SK] | 1.005 kWh | ×0.888 / ×1.13 | lognormal, GSD² 1.13 | -11.0 / +12.4 | 12.6 (Ionising radiation, human health) | | Sulfur hexafluoride [air/Unknown] | 1.154e-07 kg | ×0.637 / ×1.57 | lognormal, GSD² 1.58 | -0.5 / +0.7 | 0.7 (Climate change-Fossil) | | Transmission network, electricity, medium voltage [CH] | 1.863e-08 km | ×0.312 / ×3.21 | lognormal, GSD² 3.28 | -0.2 / +0.6 | 67.0 (Resource use, minerals and metals) | | Sulphur hexafluoride, liquid, at plant [RER] | 1.154e-07 kg | ×0.803 / ×1.24 | lognormal, GSD² 1.25 | -0.0 / +0.0 | 0.0 (Climate change-Fossil) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== ^ Source ^ Scope ^ Value ^ This dataset ^ Ratio ^ Note ^ | bafu | xxx Electricity, medium voltage, residual mix [AT] | 0.004437 kg CO2 eq | 0.2274 | 51.24 | same dataset name, other location | | bafu | xxx Electricity, medium voltage, residual mix [FR] | 0.07251 kg CO2 eq | 0.2274 | 3.14 | same dataset name, other location | | bafu | xxx Electricity, medium voltage, residual mix [SE] | 0.07718 kg CO2 eq | 0.2274 | 2.95 | same dataset name, other location | | bafu | xxx Electricity, medium voltage, residual mix [BE] | 0.2512 kg CO2 eq | 0.2274 | 0.91 | same dataset name, other location | | bafu | xxx Electricity, medium voltage, residual mix [LV] | 0.3012 kg CO2 eq | 0.2274 | 0.75 | same dataset name, other location | | bafu | xxx Electricity, medium voltage, residual mix [CZ] | 0.6885 kg CO2 eq | 0.2274 | 0.33 | same dataset name, other location | | bafu | xxx Electricity, medium voltage, residual mix [MT] | 0.7968 kg CO2 eq | 0.2274 | 0.29 | same dataset name, other location | | bafu | xxx Electricity, medium voltage, residual mix [DE] | 0.8093 kg CO2 eq | 0.2274 | 0.28 | same dataset name, other location | | bafu | xxx Electricity, medium voltage, residual mix [CY] | 0.9228 kg CO2 eq | 0.2274 | 0.25 | same dataset name, other location | | bafu | xxx Electricity, medium voltage, residual mix [PL] | 1.026 kg CO2 eq | 0.2274 | 0.22 | same dataset name, other location | ==== Conclusions and limitations ==== GWP100 0.2274 kg CO2 eq per kWh (95 % interval 0.2086–0.2764). Dominant contributors: xxx Electricity, high voltage, residual mix 98 %; Sulfur hexafluoride 1 %. Most sensitive: xxx Electricity, high voltage, residual mix [SK] (-11.0 / +12.4 %); Sulfur hexafluoride [air/Unknown] (-0.5 / +0.7 %); Transmission network, electricity, medium voltage [CH] (-0.2 / +0.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kWh | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.5e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | **PASS** | graph / published = 1.001; categories within ±5 %: 15/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 6/6 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.2274 in [0.2086, 0.2764] | | time period declared | **PASS** | 2018-01/2018-12 | | geography is a known location code | **PASS** | SK | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Krebs L., Stolz P., Frischknecht R. (2020) Umweltbilanz Strommix Schweiz 2018. Project reports. Volume: 723. treeze Ltd.. Uster, CH. Type: Separate publication First author: Krebs L. Other authors: Stolz P., Frischknecht R. Year: 2020 Title of anthology: Project reports Place of publication: Uster, CH Publisher: treeze Ltd. Volume No: 723 — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].