====== Expansion vessel 80l, at plant — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:expansion_vessel_80l_at_plant__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Expansion vessel 80l, at plant [CH], per 1 p. EF v3.1 climate change 44.98 kg CO2 eq (Monte Carlo 95 % interval 40.68–54.34). Main contributors: Steel, low-alloyed, at plant 58 %; Butyl acrylate, at plant 15 %; Light fuel oil, burned in industrial furnace 1MW, non-modula… 8 %; Disposal, plastics, mixture, 15.3% water, to municipal incin… 8 %; Corrugated board, mixed fibre, single wall, at plant 4 %; Electricity, medium voltage, at grid 3 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Expansion vessel 80l, at plant | | Dataset UUID / graph id | ''%%887e0288-8c09-3010-afa9-7a047212b020%%'' / ''%%activity:expansion_vessel_80l_at_plant__ch%%'' | | Reference product, unit | Expansion vessel 80l, at plant, 1 p | | Location | CH — Production in CH. | | Time period | 2000-01/2000-12 | | Category | heat / solar\infrastructure | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Expansion vessel with a capacity of 80l; UUID: 887e0288-8c09-3010-afa9-7a047212b020 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Expansion vessel 80l, at plant (CH). All results are given per unit of the reference flow. ==== System boundary ==== Production and disposal of an expansion vessel. Including materials and energy use of production. Not including infrastructure for factory. ==== Technology ==== Expansion vessel (steel body with plastic) for heat exchange fluid used in a solar collector system. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Steel, low-alloyed, at plant | technosphere | RER | 12.2 | kg | lognormal, GSD² 1.24 | (2,1,3,1,1,5) | 58.1 | ████████████ | | | Butyl acrylate, at plant | technosphere | RER | 1.5 | kg | lognormal, GSD² 1.24 | (2,1,3,1,1,5) | 14.9 | ███ | | | Light fuel oil, burned in industrial furnace 1MW, non-modulating | technosphere | CH | 40.2 | MJ | lognormal, GSD² 1.24 | (2,1,3,1,1,5) | 8.5 | ██ | | | Disposal, plastics, mixture, 15.3% water, to municipal incineration | technosphere | CH | 1.6 | kg | lognormal, GSD² 1.24 | (2,1,3,1,1,5) | 8.5 | ██ | | | Corrugated board, mixed fibre, single wall, at plant | technosphere | CH | 1.8 | kg | lognormal, GSD² 1.24 | (2,1,3,1,1,5) | 3.7 | █ | | | Electricity, medium voltage, at grid | technosphere | CH | 17.2 | kWh | lognormal, GSD² 1.24 | (2,1,3,1,1,5) | 3.4 | █ | | | Alkyd paint, white, 60% in solvent, at plant | technosphere | RER | 0.1 | kg | lognormal, GSD² 1.24 | (2,1,3,1,1,5) | 0.7 | · | | | Hot water tank factory | technosphere | CH | 4.0000e-07 | p | lognormal, GSD² 2.34 | (5,5,3,1,5,5) | 0.4 | · | | | Disposal, polypropylene, 15.9% water, to municipal incineration | technosphere | CH | 0.07 | kg | lognormal, GSD² 1.24 | (2,1,3,1,1,5) | 0.4 | · | | | Welding, gas, steel | technosphere | RER | 1 | m | lognormal, GSD² 1.24 | (2,1,3,1,1,5) | 0.4 | · | | | Transport, freight, rail | technosphere | RER | 9.4 | tkm | lognormal, GSD² 2.1 | — | 0.3 | · | | | Polypropylene, granulate, at plant | technosphere | RER | 0.07 | kg | lognormal, GSD² 1.24 | (2,1,3,1,1,5) | 0.3 | · | | | Transport, freight, lorry, 16t-32t gross weight, fleet average | technosphere | CH | 0.784 | tkm | lognormal, GSD² 2.1 | — | 0.3 | · | | | Disposal, packaging cardboard, 19.6% water, to municipal incineration | technosphere | CH | 1.8 | kg | lognormal, GSD² 1.24 | (2,1,3,1,1,5) | 0.1 | · | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 62 | MJ | lognormal, GSD² 1.24 | (2,1,3,1,1,5) | 0.0 | · | | ==== Data quality ==== 13 of 15 direct exchanges carry a declared pedigree, 15 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.23 · completeness 1.31 · temporal 3.0 · geographical 1.0 · technological 1.31 · sample size 5.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Niels Jungbluth (ESU); data entry: Niels Jungbluth (ESU); validation (proof reading): Sebastiano Meier | | extrapolations | Estimation that the energy for production is three times higher than for the 25l vessel. | | sampling procedure | Questionnaire. | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: Passed.; Other validation: none; | | time period comment | Time of information. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **0.1079** | 0.09638 | 0.1419 | 1.22 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.1256** | 0.09094 | 0.25 | 1.65 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **44.84** | 40.54 | 54.18 | 1.16 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.01327** | 0.01159 | 0.01965 | 1.31 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **44.98** | 40.68 | 54.34 | 1.16 | | EF-particulate Matter | Impact on human health | disease incidence | **2.348e-06** | 1.946e-06 | 3.941e-06 | 1.44 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **93.19** | 85.55 | 184.2 | 1.47 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **6.548** | 5.55 | 13.66 | 1.76 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **99.74** | 92.75 | 197.7 | 1.45 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **0.02875** | 0.02621 | 0.03788 | 1.22 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **0.01302** | 0.009416 | 0.04139 | 2.13 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **0.2763** | 0.246 | 0.3776 | 1.24 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.841e-08** | 1.608e-08 | 4.461e-08 | 1.7 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.279e-08** | 9.818e-09 | 2.273e-08 | 1.52 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **3.121e-08** | 2.840e-08 | 5.975e-08 | 1.5 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **6.989e-07** | 6.189e-07 | 1.874e-06 | 1.78 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.742e-08** | 1.590e-08 | 2.768e-08 | 1.32 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **7.163e-07** | 6.367e-07 | 1.895e-06 | 1.76 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **17.52** | 6.432 | 101.1 | 4.18 | | Land use | Soil quality index | pt (soil quality index) | **268.2** | 237.8 | 395.5 | 1.29 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **7.252e-07** | 6.601e-07 | 1.047e-06 | 1.26 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **0.1241** | 0.1094 | 0.2024 | 1.36 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **592** | 541.1 | 760.5 | 1.19 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **2.568e-04** | 2.097e-04 | 3.605e-04 | 1.32 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **3.822** | -1.434e+04 | 7516 | — | Climate change 44.98 kg CO2 eq per p. Main contributors: Steel, low-alloyed, at plant 58 %; Butyl acrylate, at plant 15 %; Light fuel oil, burned in industrial furnace 1MW, non-modula… 8 %; Disposal, plastics, mixture, 15.3% water, to municipal incin… 8 %; Corrugated board, mixed fibre, single wall, at plant 4 %; Electricity, medium voltage, at grid 3 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Steel, low-alloyed, at plant 58 %; Butyl acrylate, at plant 15 %; Light fuel oil, burned in industrial furnace 1MW, non-modula… 8 %; Disposal, plastics, mixture, 15.3% water, to municipal incin… 8 %; Corrugated board, mixed fibre, single wall, at plant 4 %; Electricity, medium voltage, at grid 3 %. Most sensitive exchanges (Section 6.3): Steel, low-alloyed, at plant [RER] (-11.0 / +13.6 %); Butyl acrylate, at plant [RER] (-2.8 / +3.5 %); Light fuel oil, burned in industrial furnace 1MW, non-modulating [CH] (-1.6 / +2.0 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 0.1079 | 0.1208 | 0.894 | | Climate change-Biogenic | 0.1256 | 0.1256 | 1.000 | | Climate change-Fossil | 44.84 | 44.84 | 1.000 | | Climate change-Land use and land use change | 0.01327 | 0.01327 | 1.000 | | Climate change | 44.98 | 44.98 | 1.000 | | EF-particulate Matter | 2.348e-06 | 2.348e-06 | 1.000 | | Ecotoxicity, freshwater_inorganics | 93.19 | 99.2 | 0.940 | | Ecotoxicity, freshwater_organics | 6.548 | 6.517 | 1.005 | | Ecotoxicity, freshwater | 99.74 | 105.6 | 0.945 | | Eutrophication marine | 0.02875 | 0.02875 | 1.000 | | Eutrophication, freshwater | 0.01302 | 0.01302 | 1.000 | | Eutrophication, terrestrial | 0.2763 | 0.2888 | 0.957 | | Human toxicity, cancer_inorganics | 1.841e-08 | 1.830e-08 | 1.006 | | Human toxicity, cancer_organics | 1.279e-08 | 1.279e-08 | 1.000 | | Human toxicity, cancer | 3.121e-08 | 3.109e-08 | 1.004 | | Human toxicity, non-cancer_inorganics | 6.989e-07 | 6.947e-07 | 1.006 | | Human toxicity, non-cancer_organics | 1.742e-08 | 1.741e-08 | 1.000 | | Human toxicity, non-cancer | 7.163e-07 | 7.121e-07 | 1.006 | | Ionising radiation, human health | 17.52 | 17.52 | 1.000 | | Land use | 268.2 | 204.5 | 1.311 | | Ozone depletion | 7.252e-07 | 7.252e-07 | 1.000 | | Photochemical ozone formation - human health | 0.1241 | 0.1241 | 1.000 | | Resource use, fossils | 592 | 592.1 | 1.000 | | Resource use, minerals and metals | 2.568e-04 | 2.545e-04 | 1.009 | | Water use | 3.822 | 4.096 | 0.933 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 44.97 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 8.444e+04 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Steel, low-alloyed, at plant [RER] | 12.2 kg | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -11.0 / +13.6 | 21.1 (Human toxicity, cancer_inorganics) | | Butyl acrylate, at plant [RER] | 1.5 kg | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -2.8 / +3.5 | 8.2 (Ecotoxicity, freshwater_organics) | | Light fuel oil, burned in industrial furnace 1MW, non-modulating [CH] | 40.2 MJ | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -1.6 / +2.0 | 2.6 (Ozone depletion) | | Disposal, plastics, mixture, 15.3% water, to municipal incineration [CH] | 1.6 kg | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -1.6 / +2.0 | 2.0 (Climate change-Fossil) | | Corrugated board, mixed fibre, single wall, at plant [CH] | 1.8 kg | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.7 / +0.9 | 8.4 (Land use) | | Electricity, medium voltage, at grid [CH] | 17.2 kWh | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.7 / +0.8 | 15.7 (Ionising radiation, human health) | | Hot water tank factory [CH] | 4.000e-07 p | ×0.435 / ×2.3 | lognormal, GSD² 2.34 | -0.2 / +0.5 | 19.6 (Land use) | | Transport, freight, rail [RER] | 9.4 tkm | ×0.483 / ×2.07 | lognormal, GSD² 2.1 | -0.2 / +0.4 | 3.4 (Human toxicity, non-cancer_organics) | | Transport, freight, lorry, 16t-32t gross weight, fleet average [CH] | 0.784 tkm | ×0.483 / ×2.07 | lognormal, GSD² 2.1 | -0.2 / +0.3 | 0.8 (Eutrophication marine) | | Alkyd paint, white, 60% in solvent, at plant [RER] | 0.1 kg | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.1 / +0.2 | 1.2 (Ecotoxicity, freshwater_organics) | | Disposal, polypropylene, 15.9% water, to municipal incineration [CH] | 0.07 kg | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.1 / +0.1 | 0.1 (Climate change-Fossil) | | Welding, gas, steel [RER] | 1 m | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.1 / +0.1 | 0.4 (EF-particulate Matter) | | Polypropylene, granulate, at plant [RER] | 0.07 kg | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.1 / +0.1 | 0.2 (Ecotoxicity, freshwater_inorganics) | | Disposal, packaging cardboard, 19.6% water, to municipal incineration [CH] | 1.8 kg | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.0 / +0.0 | 0.8 (Ecotoxicity, freshwater_inorganics) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 44.98 kg CO2 eq per p (95 % interval 40.68–54.34). Dominant contributors: Steel, low-alloyed, at plant 58 %; Butyl acrylate, at plant 15 %; Light fuel oil, burned in industrial furnace 1MW, non-modula… 8 %; Disposal, plastics, mixture, 15.3% water, to municipal incin… 8 %; Corrugated board, mixed fibre, single wall, at plant 4 %; Electricity, medium voltage, at grid 3 %. Most sensitive: Steel, low-alloyed, at plant [RER] (-11.0 / +13.6 %); Butyl acrylate, at plant [RER] (-2.8 / +3.5 %); Light fuel oil, burned in industrial furnace 1MW, non-modulating [CH] (-1.6 / +2.0 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 6.0e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 20/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 15/15 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 44.98 in [40.68, 54.34] | | time period declared | **PASS** | 2000-01/2000-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Jungbluth, N. (2007) Sonnenkollektor-Anlagen. Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0. Editors: Dones R.. Volume: 6. Swiss Centre for LCI, PSI. Dübendorf and Villigen, CH. Type: Measurement on site Source: CD-ROM First author: Jungbluth, N. Year: 2007 Name of editors: Dones R. Title of anthology: Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].