====== Disposal, ventilation system, Bürogebäude Verenastrasse, Baden, various comp. — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:disposal_ventilation_system_b|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Disposal, ventilation system, Bürogebäude Verenastrasse, Baden, various comp. [CH], per 1 p. EF v3.1 climate change 153.8 kg CO2 eq (Monte Carlo 95 % interval 127.5–189.8). Main contributors: Disposal, building, polyethylene/polypropylene products, to … 81 %; Disposal, building, bulk iron (excluding reinforcement), to … 9 %; Disposal, building, polyvinylchloride products, to final dis… 4 %; Disposal, rubber, unspecified, 0% water, to municipal incine… 4 %; Disposal, electronics for control units 2 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Disposal, ventilation system, Bürogebäude Verenastrasse, Baden, various comp. | | Dataset UUID / graph id | ''%%8bc6ecc8-e0ae-4c2c-b84a-bf0077f4ea75%%'' / ''%%activity:disposal_ventilation_system_bürogebäude_verenastrasse_baden_various_comp__ch%%'' | | Reference product, unit | Disposal, ventilation system, Bürogebäude Verenastrasse, Baden, various comp., 1 p | | Location | CH — Specific to the technology mix encountered in sorting plants in Switzerland. | | Time period | 2014-01/2014-12 | | Category | waste management / building demolition | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Disposal of various components for a ventilation system for an office building with offices, kitchen, restaurant and car park. The inventory is based on a building with a total heated gross floor area of 7492 m2 and a total nominal air flow of 42500 m3/h, total weight of the components: 4257 kg/Unit, building with a specific air flow rate of 5.7 m3/h per m2 heated gross floor area. Data from call of bid including components for air valves, air intake, roof-hoods, dampers, fire dampers, silencers and sensors.; UUID: 8bc6ecc8-e0ae-4c2c-b84a-bf0077f4ea75 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Disposal, ventilation system, Bürogebäude Verenastrasse, Baden, various comp. (CH). All results are given per unit of the reference flow. ==== System boundary ==== Transport to dismantling facilities, machines for handling in sorting plant, electricity demand for sorting plant, final disposal of waste material. Cut-off to recycling for metals. ==== Technology ==== Disposal to a sorting plant assumed. Metal pieces, copper in cables and electronic devices are recycled, plastic parts are incinerated, inert wastes (e.g. rock wool) are landfilled. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Disposal, building, polyethylene/polypropylene products, to final disposal | technosphere | CH | 40.873 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 80.6 | ████████████████ | | | Disposal, building, bulk iron (excluding reinforcement), to sorting plant | technosphere | CH | 3936.6 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 8.6 | ██ | | | Disposal, building, polyvinylchloride products, to final disposal | technosphere | CH | 2.664 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 3.6 | █ | | | Disposal, rubber, unspecified, 0% water, to municipal incineration | technosphere | CH | 1.7161 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 3.5 | █ | | | Disposal, electronics for control units | technosphere | RER | 2.758 | kg | lognormal, GSD² 1.34 | (3,4,1,1,3,5) | 2.0 | · | | | Disposal, building, mineral wool, to sorting plant | technosphere | CH | 84.702 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.9 | · | | | Disposal, building, brick, to final disposal | technosphere | CH | 171.53 | kg | lognormal, GSD² 1.34 | (3,4,1,1,3,5) | 0.8 | · | | | Disposal, building, paint on metal, to sorting plant | technosphere | CH | 0.20601 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.0 | · | | ==== Data quality ==== 8 of 8 direct exchanges carry a declared pedigree, 8 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.0 · completeness 4.0 · temporal 1.0 · geographical 1.0 · technological 1.5 · sample size 5.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU) | | extrapolations | none | | sampling procedure | Waste-specific calculation based on production input data | | production volume | na | | uncertainty adjustments | none | | time period comment | Amount of material investigated in 2013. Disposal technology mix as used in late 1990ies | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **0.04065** | 0.0366 | 0.05498 | 1.23 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.04371** | 0.03227 | 0.07414 | 1.54 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **153.7** | 127.4 | 189.8 | 1.22 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.00723** | 0.005961 | 0.01082 | 1.36 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **153.8** | 127.5 | 189.8 | 1.22 | | EF-particulate Matter | Impact on human health | disease incidence | **2.485e-06** | 1.817e-06 | 4.371e-06 | 1.58 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **403.7** | 344.1 | 567 | 1.3 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **3.165** | 2.508 | 6.099 | 1.57 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **406.9** | 347.7 | 571.8 | 1.3 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **0.03399** | 0.02868 | 0.04689 | 1.29 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **0.01173** | 0.004423 | 0.296 | 8.58 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **0.2864** | 0.2404 | 0.3927 | 1.29 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **6.531e-09** | 5.694e-09 | 2.990e-08 | 2.36 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.653e-09** | 2.413e-09 | 3.863e-09 | 1.28 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **9.183e-09** | 8.591e-09 | 3.301e-08 | 2.01 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.803e-07** | 3.271e-07 | 1.664e-06 | 2.29 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.895e-08** | 1.631e-08 | 2.672e-08 | 1.29 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **3.993e-07** | 3.469e-07 | 1.686e-06 | 2.23 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **8.315** | 3.046 | 44.52 | 4.19 | | Land use | Soil quality index | pt (soil quality index) | **255.9** | 139.2 | 437.8 | — | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **7.055e-07** | 5.985e-07 | 1.036e-06 | 1.32 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **0.1221** | 0.1025 | 0.1685 | 1.29 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **309.1** | 269.5 | 409.3 | 1.24 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **4.649e-05** | 3.694e-05 | 9.122e-05 | 1.6 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **13.36** | -3150 | 1758 | — | Climate change 153.8 kg CO2 eq per p. Main contributors: Disposal, building, polyethylene/polypropylene products, to … 81 %; Disposal, building, bulk iron (excluding reinforcement), to … 9 %; Disposal, building, polyvinylchloride products, to final dis… 4 %; Disposal, rubber, unspecified, 0% water, to municipal incine… 4 %; Disposal, electronics for control units 2 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Disposal, building, polyethylene/polypropylene products, to … 81 %; Disposal, building, bulk iron (excluding reinforcement), to … 9 %; Disposal, building, polyvinylchloride products, to final dis… 4 %; Disposal, rubber, unspecified, 0% water, to municipal incine… 4 %; Disposal, electronics for control units 2 %. Most sensitive exchanges (Section 6.3): Disposal, building, polyethylene/polypropylene products, to final disposal [CH] (-16.3 / +20.5 %); Disposal, building, bulk iron (excluding reinforcement), to sorting plant [CH] (-1.7 / +2.2 %); Disposal, building, polyvinylchloride products, to final disposal [CH] (-0.7 / +0.9 %). ==== Independent recalculation ==== The publisher publishes no LCIA result for this dataset; the closure check of Section 7 is the recalculation test. ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Disposal, building, polyethylene/polypropylene products, to final disposal [CH] | 40.87 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -16.3 / +20.5 | 20.5 (Climate change-Fossil) | | Disposal, building, bulk iron (excluding reinforcement), to sorting plant [CH] | 3937 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -1.7 / +2.2 | 23.3 (Ionising radiation, human health) | | Disposal, building, polyvinylchloride products, to final disposal [CH] | 2.664 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.7 / +0.9 | 20.2 (Water use) | | Disposal, rubber, unspecified, 0% water, to municipal incineration [CH] | 1.716 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.7 / +0.9 | 0.9 (Climate change-Fossil) | | Disposal, electronics for control units [RER] | 2.758 kg | ×0.751 / ×1.33 | lognormal, GSD² 1.34 | -0.5 / +0.7 | 5.5 (Human toxicity, non-cancer_inorganics) | | Disposal, building, brick, to final disposal [CH] | 171.5 kg | ×0.751 / ×1.33 | lognormal, GSD² 1.34 | -0.2 / +0.3 | 17.6 (EF-particulate Matter) | | Disposal, building, mineral wool, to sorting plant [CH] | 84.7 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.2 / +0.2 | 12.0 (Eutrophication, freshwater) | | Disposal, building, paint on metal, to sorting plant [CH] | 0.206 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.0 / +0.0 | 0.0 (Human toxicity, non-cancer_organics) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 153.8 kg CO2 eq per p (95 % interval 127.5–189.8). Dominant contributors: Disposal, building, polyethylene/polypropylene products, to … 81 %; Disposal, building, bulk iron (excluding reinforcement), to … 9 %; Disposal, building, polyvinylchloride products, to final dis… 4 %; Disposal, rubber, unspecified, 0% water, to municipal incine… 4 %; Disposal, electronics for control units 2 %. Most sensitive: Disposal, building, polyethylene/polypropylene products, to final disposal [CH] (-16.3 / +20.5 %); Disposal, building, bulk iron (excluding reinforcement), to sorting plant [CH] (-1.7 / +2.2 %); Disposal, building, polyvinylchloride products, to final disposal [CH] (-0.7 / +0.9 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.7e-16 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 8/8 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 153.8 in [127.5, 189.8] | | time period declared | **PASS** | 2014-01/2014-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].