====== Heat pump, air-water, 7kW — RER ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:heat_pump_air_water_7kw__rer|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Heat pump, air-water, 7kW [RER], per 1 p. EF v3.1 climate change 1634 kg CO2 eq (Monte Carlo 95 % interval 1458–2308). Main contributors: Steel, low-alloyed, at plant 19 %; Aluminium, primary, at plant 18 %; Electronic component, unspecified, at plant 17 %; Pentafluoroethane 12 %; Electricity, medium voltage, production ENTSO-E, at grid 9 %; Natural gas, burned in industrial furnace 1MWth 7 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Heat pump, air-water, 7kW | | Dataset UUID / graph id | ''%%8cddf964-9457-3e49-90bc-a607d4f7b4c5%%'' / ''%%activity:heat_pump_air_water_7kw__rer%%'' | | Reference product, unit | Heat pump, air-water, 7kW, 1 p | | Location | RER — Data apply to the supply in Switzerland. | | Time period | 2019-01/2020-12 | | Category | heat / heat pumps\heating systems | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Inventory for the production of an air-water heat pump, 7kW with a life time of 20 years.; Synonyms: Wärmepumpe mit Wärmetauscher Luft/ Wasser 7kW; UUID: 8cddf964-9457-3e49-90bc-a607d4f7b4c5 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Heat pump, air-water, 7kW (RER). All results are given per unit of the reference flow. ==== System boundary ==== Infrastructure of the air-water heat pump including all material inputs (pipes, air heat exchanger, coolant) and also the energy use for the construction of the heat pump components. ==== Technology ==== average technology available on market ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Steel, low-alloyed, at plant | technosphere | RER | 146.9 | kg | lognormal, GSD² 1.4 | — | 19.2 | ████ | | | Aluminium, primary, at plant | technosphere | RER | 32.3 | kg | lognormal, GSD² 1.4 | — | 17.6 | ████ | | | Electronic component, unspecified, at plant | technosphere | GLO | 1.5 | kg | lognormal, GSD² 1.4 | — | 16.6 | ███ | | | Electricity, medium voltage, production ENTSO-E, at grid | technosphere | ENTSO-E | 557.2 | kWh | lognormal, GSD² 1.55 | — | 9.3 | ██ | | | Natural gas, burned in industrial furnace 1MWth | technosphere | CH | 1498.4 | MJ | lognormal, GSD² 1.22 | — | 7.0 | █ | | | Copper, at regional storage | technosphere | RER | 59.2 | kg | lognormal, GSD² 1.4 | — | 5.8 | █ | | | Tube insulation, elastomere, at plant | technosphere | DE | 12.1 | kg | lognormal, GSD² 1.4 | — | 3.3 | █ | | | Disposal, plastics, mixture, 15.3% water, to municipal incineration | technosphere | CH | 13.3 | kg | lognormal, GSD² 1.4 | — | 1.9 | · | | | Heat, biomethane, at industrial furnace 1MW | technosphere | CH | 704.37 | MJ | lognormal, GSD² 1.55 | — | 1.7 | · | | | Trifluoromethane, at plant | technosphere | GLO | 1.75 | kg | lognormal, GSD² 1.62 | — | 1.0 | · | | | 1,1-difluoroethane, HFC-152a, at plant | technosphere | US | 1.75 | kg | lognormal, GSD² 1.62 | — | 0.5 | · | | | Light fuel oil, burned in industrial furnace 1MW, non-modulating | technosphere | RER | 47.296 | MJ | lognormal, GSD² 1.22 | — | 0.3 | · | | | Rock wool, at plant | technosphere | CH | 4 | kg | lognormal, GSD² 1.31 | — | 0.3 | · | | | Lubricating oil, at plant | technosphere | RER | 2.2 | kg | lognormal, GSD² 1.55 | — | 0.2 | · | | | Heat, mixed chips from forest, at furnace 1000kW | technosphere | CH | 571 | MJ | lognormal, GSD² 1.55 | — | 0.2 | · | | | Polyvinylchloride, bulk polymerised, at plant | technosphere | RER | 1.2 | kg | lognormal, GSD² 1.4 | — | 0.2 | · | | | Transport, freight, rail | technosphere | RER | 154 | tkm | lognormal, GSD² 2.34 | — | 0.2 | · | | | Transport, freight, lorry, 16t-32t gross weight, fleet average | technosphere | CH | 12.8 | tkm | lognormal, GSD² 2.34 | — | 0.1 | · | | | Pentafluoroethane | elementary | air/Ground level / Urban (>1000 people/s… | 0.0525 | kg | lognormal, GSD² 1.56 | — | 12.0 | ██ | | | Difluoromethane | elementary | air/Ground level / Urban (>1000 people/s… | 0.0525 | kg | lognormal, GSD² 1.56 | — | 2.5 | · | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 2005.9 | MJ | lognormal, GSD² 1.4 | — | 0.0 | · | | | Industrial area | elementary | natural resource | 8.26 | m2.a | lognormal, GSD² 1.57 | — | 0.0 | · | | | Industrial area | elementary | natural resource | 2.28 | m2.a | lognormal, GSD² 1.57 | — | 0.0 | · | | | Water | elementary | natural resource | 0.95 | m3 | lognormal, GSD² 1.4 | — | 0.0 | · | | ==== Data quality ==== 0 of 24 direct exchanges carry a declared pedigree, 24 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Cyrill Kern (CARBOTECH); data entry: Thomas Kaegi (CARBOTECH); validation (proof reading): Andy Spoerri (EBP) | | extrapolations | | | sampling procedure | Data provided by manufacturer | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: 19.02.2021; Other validation: Z:\Schreibtisch\WinShare\BAFU Heizsysteme\A_zum konvertieren\WP[EcoSpold_heat pump, air-water _NEU 7kW.xlsx]X-Process; | | time period comment | undefined | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **13.88** | 11.1 | 20.29 | 1.37 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **21.97** | 13.95 | 39.89 | 1.68 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1611** | 1432 | 2287 | 1.26 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.8658** | 0.6674 | 1.386 | 1.45 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1634** | 1458 | 2308 | 1.26 | | EF-particulate Matter | Impact on human health | disease incidence | **8.599e-05** | 7.667e-05 | 1.339e-04 | 1.33 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **7546** | 6808 | 1.905e+04 | 1.72 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **245.9** | 211.3 | 467.8 | 1.57 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **7792** | 7063 | 1.952e+04 | 1.7 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **1.761** | 1.439 | 3.287 | 1.55 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **5.212** | 3.103 | 38.64 | 3.53 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **17.22** | 13.96 | 28.98 | 1.47 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.885e-06** | 1.669e-06 | 5.331e-06 | 1.87 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **6.255e-07** | 5.258e-07 | 1.100e-06 | 1.47 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.511e-06** | 2.325e-06 | 6.133e-06 | 1.7 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.455e-04** | 1.167e-04 | 4.236e-04 | 1.97 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.015e-05** | 6.090e-06 | 2.119e-05 | 1.84 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.556e-04** | 1.289e-04 | 4.367e-04 | 1.92 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **534.1** | 181.3 | 3273 | 4.44 | | Land use | Soil quality index | pt (soil quality index) | **1.549e+04** | 1.329e+04 | 2.451e+04 | 1.36 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **0.002293** | 0.001016 | 0.005668 | 2.36 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **5.932** | 5.177 | 9.587 | 1.38 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **1.97e+04** | 1.738e+04 | 3.13e+04 | 1.35 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.3581** | 0.1972 | 0.9267 | 2.22 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **186.2** | -5.085e+05 | 2.699e+05 | — | Climate change 1634 kg CO2 eq per p. Main contributors: Steel, low-alloyed, at plant 19 %; Aluminium, primary, at plant 18 %; Electronic component, unspecified, at plant 17 %; Pentafluoroethane 12 %; Electricity, medium voltage, production ENTSO-E, at grid 9 %; Natural gas, burned in industrial furnace 1MWth 7 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Steel, low-alloyed, at plant 19 %; Aluminium, primary, at plant 18 %; Electronic component, unspecified, at plant 17 %; Pentafluoroethane 12 %; Electricity, medium voltage, production ENTSO-E, at grid 9 %; Natural gas, burned in industrial furnace 1MWth 7 %. Most sensitive exchanges (Section 6.3): Steel, low-alloyed, at plant [RER] (-5.4 / +7.4 %); Aluminium, primary, at plant [RER] (-4.9 / +6.8 %); Electronic component, unspecified, at plant [GLO] (-4.6 / +6.4 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 13.88 | 15.17 | 0.914 | | Climate change-Biogenic | 21.97 | 21.97 | 1.000 | | Climate change-Fossil | 1611 | 1611 | 1.000 | | Climate change-Land use and land use change | 0.8658 | 0.8658 | 1.000 | | Climate change | 1634 | 1634 | 1.000 | | EF-particulate Matter | 8.599e-05 | 8.599e-05 | 1.000 | | Ecotoxicity, freshwater_inorganics | 7546 | 7834 | 0.963 | | Ecotoxicity, freshwater_organics | 245.9 | 233.5 | 1.053 | | Ecotoxicity, freshwater | 7792 | 7971 | 0.977 | | Eutrophication marine | 1.761 | 1.761 | 1.000 | | Eutrophication, freshwater | 5.212 | 5.212 | 1.000 | | Eutrophication, terrestrial | 17.22 | 18.11 | 0.951 | | Human toxicity, cancer_inorganics | 1.885e-06 | 1.874e-06 | 1.006 | | Human toxicity, cancer_organics | 6.255e-07 | 6.255e-07 | 1.000 | | Human toxicity, cancer | 2.511e-06 | 2.500e-06 | 1.004 | | Human toxicity, non-cancer_inorganics | 1.455e-04 | 1.448e-04 | 1.004 | | Human toxicity, non-cancer_organics | 1.015e-05 | 1.015e-05 | 1.000 | | Human toxicity, non-cancer | 1.556e-04 | 1.550e-04 | 1.004 | | Ionising radiation, human health | 534.1 | 534.1 | 1.000 | | Land use | 1.549e+04 | 1.088e+04 | 1.424 | | Ozone depletion | 0.002293 | 0.002293 | 1.000 | | Photochemical ozone formation - human health | 5.932 | 5.932 | 1.000 | | Resource use, fossils | 1.97e+04 | 1.971e+04 | 1.000 | | Resource use, minerals and metals | 0.3581 | 0.3578 | 1.001 | | Water use | 186.2 | 172.5 | 1.080 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 1634 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 5.143e+06 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Steel, low-alloyed, at plant [RER] | 146.9 kg | ×0.721 / ×1.39 | lognormal, GSD² 1.4 | -5.4 / +7.4 | 9.6 (EF-particulate Matter) | | Aluminium, primary, at plant [RER] | 32.3 kg | ×0.721 / ×1.39 | lognormal, GSD² 1.4 | -4.9 / +6.8 | 18.2 (Climate change-Land use and land use change) | | Electronic component, unspecified, at plant [GLO] | 1.5 kg | ×0.721 / ×1.39 | lognormal, GSD² 1.4 | -4.6 / +6.4 | 30.9 (Resource use, minerals and metals) | | Pentafluoroethane [air/Ground level / Urban (>1000 people/square mile)] | 0.0525 kg | ×0.647 / ×1.55 | lognormal, GSD² 1.56 | -4.2 / +6.6 | 6.7 (Climate change-Fossil) | | Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] | 557.2 kWh | ×0.652 / ×1.53 | lognormal, GSD² 1.55 | -3.2 / +5.0 | 20.1 (Ionising radiation, human health) | | Copper, at regional storage [RER] | 59.2 kg | ×0.721 / ×1.39 | lognormal, GSD² 1.4 | -1.6 / +2.3 | 35.6 (Human toxicity, non-cancer_organics) | | Natural gas, burned in industrial furnace 1MWth [CH] | 1498 MJ | ×0.826 / ×1.21 | lognormal, GSD² 1.22 | -1.2 / +1.5 | 2.0 (Resource use, fossils) | | Difluoromethane [air/Ground level / Urban (>1000 people/square mile)] | 0.0525 kg | ×0.647 / ×1.55 | lognormal, GSD² 1.56 | -0.9 / +1.4 | 1.4 (Climate change-Fossil) | | Tube insulation, elastomere, at plant [DE] | 12.1 kg | ×0.721 / ×1.39 | lognormal, GSD² 1.4 | -0.9 / +1.3 | 3.2 (Climate change-Land use and land use change) | | Heat, biomethane, at industrial furnace 1MW [CH] | 704.4 MJ | ×0.652 / ×1.53 | lognormal, GSD² 1.55 | -0.6 / +0.9 | 39.2 (Climate change-Biogenic) | | Disposal, plastics, mixture, 15.3% water, to municipal incineration [CH] | 13.3 kg | ×0.721 / ×1.39 | lognormal, GSD² 1.4 | -0.5 / +0.7 | 0.8 (Climate change-Fossil) | | Trifluoromethane, at plant [GLO] | 1.75 kg | ×0.621 / ×1.61 | lognormal, GSD² 1.62 | -0.4 / +0.6 | 59.5 (Ozone depletion) | | 1,1-difluoroethane, HFC-152a, at plant [US] | 1.75 kg | ×0.621 / ×1.61 | lognormal, GSD² 1.62 | -0.2 / +0.3 | 0.4 (Water use) | | Transport, freight, rail [RER] | 154 tkm | ×0.435 / ×2.3 | lognormal, GSD² 2.34 | -0.1 / +0.2 | 0.7 (Land use) | | Transport, freight, lorry, 16t-32t gross weight, fleet average [CH] | 12.8 tkm | ×0.435 / ×2.3 | lognormal, GSD² 2.34 | -0.1 / +0.2 | 0.3 (Photochemical ozone formation - human health) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 1634 kg CO2 eq per p (95 % interval 1458–2308). Dominant contributors: Steel, low-alloyed, at plant 19 %; Aluminium, primary, at plant 18 %; Electronic component, unspecified, at plant 17 %; Pentafluoroethane 12 %; Electricity, medium voltage, production ENTSO-E, at grid 9 %; Natural gas, burned in industrial furnace 1MWth 7 %. Most sensitive: Steel, low-alloyed, at plant [RER] (-5.4 / +7.4 %); Aluminium, primary, at plant [RER] (-4.9 / +6.8 %); Electronic component, unspecified, at plant [GLO] (-4.6 / +6.4 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 4.7e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 24/24 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 1634 in [1458, 2308] | | time period declared | **PASS** | 2019-01/2020-12 | | geography is a known location code | **PASS** | RER | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Kägi Thomas, Livia Waldburger, Cyril Kern, Gavin Roberts, Mischa Zschokke, Flora Conte, Lea Weber (2020) LCI of heating systems. Carbotech im Auftrag des BAFU. Carbotech AG. Zürich. CH. Type: Separate publication Source: Report First author: Kägi Thomas Other authors: Livia Waldburger, Cyril Kern, Gavin Roberts, Mischa Zschokke, Flora Conte, Lea Weber Year: 2020 Title of anthology: Carbotech im Au… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].