====== Ventilation system, Geschäftshaus B, Esslingen, various components — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:ventilation_system_gesch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Ventilation system, Geschäftshaus B, Esslingen, various components [CH], per 1 p. EF v3.1 climate change 1456 kg CO2 eq (Monte Carlo 95 % interval 1341–1772). Main contributors: Chromium steel 18/8, at plant 51 %; Steel, converter, unalloyed, at plant 17 %; Metal working factory operation, average heat energy 6 %; Sheet rolling, chromium steel 5 %; Sheet rolling, steel 4 %; Electricity, medium voltage, production ENTSO-E, at grid 4 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Ventilation system, Geschäftshaus B, Esslingen, various components | | Dataset UUID / graph id | ''%%8e74122d-d293-3307-80bb-537fd671e2ef%%'' / ''%%activity:ventilation_system_geschäftshaus_b_esslingen_various_components__ch%%'' | | Reference product, unit | Ventilation system, Geschäftshaus B, Esslingen, various components, 1 p | | Location | CH | | Time period | 2014-01/2014-12 | | Category | ventilation / production of components | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Production of various components for a ventilation system for an office building with offices only (no kitchen, restaurant or car park). The inventory is based on a building with a total heated gross floor area of 2472 m2 and a total nominal air flow of 5700 m3/h, total weight of the components: 351 kg/Unit, building with a specific air flow rate of 2.3 m3/h per m2 heated gross floor area. Data from call of bid including components for air valves, air intake, roof-hoods, dampers, fire dampers, silencers and sensors.; UUID: 8e74122d-d293-3307-80bb-537fd671e2ef This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Ventilation system, Geschäftshaus B, Esslingen, various components (CH). All results are given per unit of the reference flow. ==== System boundary ==== Materials used for the production. Energy use for the different production steps and for heating the production building. Transport of raw materials to the plant. Estimation for infrastructure of the production site included. ==== Technology ==== Technology, materials and components used for ventilation systems in commercial and public buildings ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Chromium steel 18/8, at plant | technosphere | RER | 168.19 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 51.0 | ██████████ | | | Steel, converter, unalloyed, at plant | technosphere | RER | 102.96 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 17.0 | ███ | | | Metal working factory operation, average heat energy | technosphere | RER | 350.73 | kg | lognormal, GSD² 1.27 | (2,4,2,1,3,4) | 6.2 | █ | | | Sheet rolling, chromium steel | technosphere | RER | 168.19 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 5.0 | █ | | | Sheet rolling, steel | technosphere | RER | 163.43 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 4.2 | █ | | | Electricity, medium voltage, production ENTSO-E, at grid | technosphere | ENTSO-E | 210.44 | kWh | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 4.0 | █ | | | Zinc coating, coils | technosphere | RER | 13.892 | m2 | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 3.9 | █ | | | Steel, electric, un- and low-alloyed, at plant | technosphere | RER | 60.471 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 2.3 | · | | | Polycarbonate, at plant | technosphere | RER | 3.0432 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 1.7 | · | | | Metal working factory | technosphere | RER | 1.6063e-07 | p | lognormal, GSD² 3.07 | (2,4,2,1,3,4) | 1.1 | · | | | Aluminium, production mix, wrought alloy, at plant | technosphere | RER | 3.0837 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 1.1 | · | | | Printed wiring board, through-hole mounted, unspec., solder mix, at plant | technosphere | GLO | 0.22354 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.6 | · | | | Synthetic rubber, at plant | technosphere | RER | 2.1685 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.4 | · | | | Brass, at plant | technosphere | CH | 2.5565 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.4 | · | | | Transport, freight, rail | technosphere | RER | 203.99 | tkm | lognormal, GSD² 2.14 | (4,5,1,1,1,5) | 0.2 | · | | | Injection moulding | technosphere | RER | 3.1172 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.2 | · | | | Autoclaved aerated concrete block, at plant | technosphere | CH | 7.7629 | kg | lognormal, GSD² 1.34 | (3,4,1,1,3,5) | 0.2 | · | | | Transport, freight, lorry, 16t-32t gross weight, fleet average | technosphere | CH | 17.537 | tkm | lognormal, GSD² 2.14 | (4,5,1,1,1,5) | 0.2 | · | | | Sheet rolling, aluminium | technosphere | RER | 3.0837 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.1 | · | | | Wire drawing, copper | technosphere | RER | 2.6245 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.1 | · | | | Zinc, primary, at regional storage | technosphere | RER | 0.122 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.0 | · | | | Polyvinylchloride, at regional storage | technosphere | RER | 0.074 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.0 | · | | | Powder coating, steel | technosphere | RER | 0.037009 | m2 | lognormal, GSD² 1.32 | (4,4,1,1,1,5) | 0.0 | · | | | Copper, at regional storage | technosphere | RER | 0.068 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.0 | · | | | Casting, bronze | technosphere | CH | 0.122 | kg | lognormal, GSD² 1.34 | (3,4,1,1,3,5) | 0.0 | · | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 757.58 | MJ | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.0 | · | | ==== Data quality ==== 26 of 26 direct exchanges carry a declared pedigree, 26 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.04 · completeness 4.08 · temporal 1.08 · geographical 1.0 · technological 1.31 · sample size 4.92. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU) | | extrapolations | none | | sampling procedure | Data from call of bids for a ventilation system of a specific building used. Data completed with information from literature and from manufacturers | | production volume | na | | uncertainty adjustments | none | | time period comment | Amount of material investigated in 2013. Process information partly from 2003 to 2012 | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **10.41** | 8.168 | 17.1 | 1.45 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **6.1** | 3.977 | 13.08 | 1.8 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1450** | 1336 | 1765 | 1.15 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.4194** | 0.3809 | 0.6473 | 1.31 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1456** | 1341 | 1772 | 1.15 | | EF-particulate Matter | Impact on human health | disease incidence | **1.354e-04** | 1.134e-04 | 2.024e-04 | 1.35 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **6186** | 5843 | 1.06e+04 | 1.35 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **80.09** | 76.82 | 969.3 | 3.55 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **6266** | 5920 | 1.093e+04 | 1.41 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **1.39** | 1.269 | 1.957 | 1.25 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **0.6767** | 0.4838 | 2.463 | 2.32 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **32.52** | 23.02 | 61.26 | 1.65 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.299e-06** | 1.169e-06 | 2.592e-06 | 1.5 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.213e-07** | 4.385e-07 | 8.503e-07 | 1.39 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.820e-06** | 1.713e-06 | 3.236e-06 | 1.38 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **6.283e-05** | 5.355e-05 | 1.643e-04 | 1.79 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.234e-06** | 9.761e-07 | 2.230e-06 | 1.53 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **6.406e-05** | 5.482e-05 | 1.652e-04 | 1.77 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **384.4** | 137.7 | 2404 | 4.32 | | Land use | Soil quality index | pt (soil quality index) | **8604** | 7407 | 1.586e+04 | 1.47 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **2.550e-05** | 2.322e-05 | 4.037e-05 | 1.32 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **4.577** | 4.28 | 6.897 | 1.28 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **1.701e+04** | 1.544e+04 | 2.361e+04 | 1.24 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.03547** | 0.005719 | 0.09035 | — | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **168.1** | -1.374e+06 | 7.468e+05 | — | Climate change 1456 kg CO2 eq per p. Main contributors: Chromium steel 18/8, at plant 51 %; Steel, converter, unalloyed, at plant 17 %; Metal working factory operation, average heat energy 6 %; Sheet rolling, chromium steel 5 %; Sheet rolling, steel 4 %; Electricity, medium voltage, production ENTSO-E, at grid 4 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Chromium steel 18/8, at plant 51 %; Steel, converter, unalloyed, at plant 17 %; Metal working factory operation, average heat energy 6 %; Sheet rolling, chromium steel 5 %; Sheet rolling, steel 4 %; Electricity, medium voltage, production ENTSO-E, at grid 4 %. Most sensitive exchanges (Section 6.3): Chromium steel 18/8, at plant [RER] (-10.3 / +13.0 %); Steel, converter, unalloyed, at plant [RER] (-3.5 / +4.3 %); Metal working factory operation, average heat energy [RER] (-1.3 / +1.6 %). ==== Independent recalculation ==== The publisher publishes no LCIA result for this dataset; the closure check of Section 7 is the recalculation test. ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Chromium steel 18/8, at plant [RER] | 168.2 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -10.3 / +13.0 | 18.6 (Human toxicity, cancer_inorganics) | | Steel, converter, unalloyed, at plant [RER] | 103 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -3.5 / +4.3 | 6.8 (Human toxicity, cancer_organics) | | Metal working factory operation, average heat energy [RER] | 350.7 kg | ×0.791 / ×1.26 | lognormal, GSD² 1.27 | -1.3 / +1.6 | 8.9 (Water use) | | Metal working factory [RER] | 1.606e-07 p | ×0.333 / ×3 | lognormal, GSD² 3.07 | -0.7 / +2.2 | 45.8 (Land use) | | Sheet rolling, chromium steel [RER] | 168.2 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -1.0 / +1.3 | 5.2 (Ecotoxicity, freshwater_inorganics) | | Sheet rolling, steel [RER] | 163.4 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.9 / +1.1 | 2.0 (Water use) | | Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] | 210.4 kWh | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.8 / +1.0 | 5.0 (Ionising radiation, human health) | | Zinc coating, coils [RER] | 13.89 m2 | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.8 / +1.0 | 16.6 (Eutrophication, terrestrial) | | Steel, electric, un- and low-alloyed, at plant [RER] | 60.47 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.5 / +0.6 | 1.5 (Ecotoxicity, freshwater_organics) | | Polycarbonate, at plant [RER] | 3.043 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.3 / +0.4 | 2.1 (Ecotoxicity, freshwater_inorganics) | | Aluminium, production mix, wrought alloy, at plant [RER] | 3.084 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.2 / +0.3 | 1.3 (Climate change-Land use and land use change) | | Transport, freight, rail [RER] | 204 tkm | ×0.474 / ×2.11 | lognormal, GSD² 2.14 | -0.1 / +0.3 | 1.4 (Land use) | | Transport, freight, lorry, 16t-32t gross weight, fleet average [CH] | 17.54 tkm | ×0.474 / ×2.11 | lognormal, GSD² 2.14 | -0.1 / +0.2 | 0.8 (Ecotoxicity, freshwater_organics) | | Printed wiring board, through-hole mounted, unspec., solder mix, at plant [GLO] | 0.2235 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.1 / +0.2 | 3.0 (Resource use, minerals and metals) | | Synthetic rubber, at plant [RER] | 2.168 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.1 / +0.1 | 0.6 (Climate change-Land use and land use change) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 1456 kg CO2 eq per p (95 % interval 1341–1772). Dominant contributors: Chromium steel 18/8, at plant 51 %; Steel, converter, unalloyed, at plant 17 %; Metal working factory operation, average heat energy 6 %; Sheet rolling, chromium steel 5 %; Sheet rolling, steel 4 %; Electricity, medium voltage, production ENTSO-E, at grid 4 %. Most sensitive: Chromium steel 18/8, at plant [RER] (-10.3 / +13.0 %); Steel, converter, unalloyed, at plant [RER] (-3.5 / +4.3 %); Metal working factory operation, average heat energy [RER] (-1.3 / +1.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 4.4e-16 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 26/26 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 1456 in [1341, 1772] | | time period declared | **PASS** | 2014-01/2014-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].