====== Disposal, ventilation system, Bürogebäude Verenastrasse, Baden — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:disposal_ventilation_system_b|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Disposal, ventilation system, Bürogebäude Verenastrasse, Baden [CH], per 1 p. EF v3.1 climate change 4778 kg CO2 eq (Monte Carlo 95 % interval 4401–5673). Main contributors: Disposal, ventilation unit 13000 m3/h, w. rotary heat exchan… 23 %; Disposal, ventilation unit 13000 m3/h, w. circuit connected … 18 %; Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alum… 12 %; Disposal, ventilation unit 6700 m3/h, w. cross plate heat ex… 11 %; Disposal, ventilation duct, steel, zinc coated, s= 0.75mm 7 %; Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm 6 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Disposal, ventilation system, Bürogebäude Verenastrasse, Baden | | Dataset UUID / graph id | ''%%8ec3aded-88de-4450-b962-32a59b431a9f%%'' / ''%%activity:disposal_ventilation_system_bürogebäude_verenastrasse_baden__ch%%'' | | Reference product, unit | Disposal, ventilation system, Bürogebäude Verenastrasse, Baden, 1 p | | Location | CH — Specific to the technology mix encountered in sorting plants in Switzerland. | | Time period | 2014-01/2014-12 | | Category | waste management / building demolition | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Disposal of a ventilation system for an office building with offices, kitchen, restaurant and car park. The inventory is based on a building with a total heated gross floor area of 7492 m2 and a total nominal air flow of 42500 m3/h, total weight of the components: 10121 kg/Unit, building with a specific air flow rate of 5.7 m3/h per m2 heated gross floor area. Data from call of bid including components for air handling units, ducts including insulation, air valves, roof-hoods, dampers, fire dampers, silencers. The data represent a ductwork mainly made of galvanized steel and includes air handling units mainly with heat recovery. System with central air handling units. Building without ground heat exchanger.; UUID: 8ec3aded-88de-4450-b962-32a59b431a9f This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Disposal, ventilation system, Bürogebäude Verenastrasse, Baden (CH). All results are given per unit of the reference flow. ==== System boundary ==== Transport to dismantling facilities, machines for handling in sorting plant, electricity demand for sorting plant, final disposal of waste material. Cut-off to recycling for metals. ==== Technology ==== Disposal to a sorting plant assumed. Metal pieces, copper in cables and electronic devices are recycled, plastic parts are incinerated, inert wastes (e.g. rock wool) are landfilled. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Disposal, ventilation unit 13000 m3/h, w. rotary heat exchanger | technosphere | CH | 1.292 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 22.5 | █████ | | | Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger | technosphere | CH | 1 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 17.5 | ████ | | | Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil | technosphere | CH | 3664.7 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 12.5 | ██ | | | Disposal, ventilation unit 6700 m3/h, w. cross plate heat excanger | technosphere | CH | 0.972 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 10.7 | ██ | | | Disposal, ventilation duct, steel, zinc coated, s= 0.75mm | technosphere | CH | 1872.1 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 7.2 | █ | | | Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm | technosphere | CH | 837.61 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 5.8 | █ | | | Disposal, ventilation duct, steel, zinc coated, s= 0.87mm | technosphere | CH | 1031.8 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 4.1 | █ | | | Disposal, ventilation system, Bürogebäude Verenastrasse, Baden, various comp. | technosphere | CH | 1 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 3.2 | █ | | | Disposal, silencer for ventilator unit 13000 m3/h, modular | technosphere | CH | 4.584 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 2.4 | · | | | Disposal, ventilator unit 3500 m3/h, modular, w. filter, without silencer | technosphere | CH | 0.974 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 2.4 | · | | | Disposal, ventilation duct, steel, zinc coated, s= 1.25mm | technosphere | CH | 459.02 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.9 | · | | | Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil | technosphere | CH | 316.52 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.7 | · | | | Disposal, ventilation duct, steel, zinc coated, s= 0.62mm | technosphere | CH | 425.66 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.6 | · | | | Disposal, EI 60 fire insulation, 70mm, 120kg/m3, reinforced alumium foil | technosphere | CH | 234.67 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.4 | · | | | Disposal, flexible duct, aluminum/PET, DN of 125 | technosphere | CH | 251.2 | m | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.4 | · | | | Disposal, ventilation duct, steel, zinc coated, s= 1.0mm | technosphere | CH | 308.84 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.2 | · | | | Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm | technosphere | CH | 115.81 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.8 | · | | | Disposal, silencer for ventilator unit 6700 m3/h, modular, Device | technosphere | CH | 1.944 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.7 | · | | | Disposal, silencer for ventilator unit 3500 m3/h, modular | technosphere | CH | 0.974 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.3 | · | | | Disposal, ventilation duct, steel, zinc coated, s= 1.5mm | technosphere | CH | 57.001 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.2 | · | | | Disposal, ventilation system, Bürogebäude Verenastrasse, Baden, special comp. | technosphere | CH | 1 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.2 | · | | | Disposal, thermal insulation, 30mm, 40kg/m3, stainless steel cladding | technosphere | CH | 184.8 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.2 | · | | | Disposal, thermal insulation, 60mm, 40kg/m3, stainless steel cladding | technosphere | CH | 95.891 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · | | ==== Data quality ==== 23 of 23 direct exchanges carry a declared pedigree, 23 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.3 · completeness 4.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 5.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU) | | extrapolations | none | | sampling procedure | Waste-specific calculation based on production input data | | production volume | na | | uncertainty adjustments | none | | time period comment | Amount of material investigated in 2013. Disposal technology mix as used in late 1990ies | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **1.308** | 1.196 | 2.631 | 1.49 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.9588** | 0.7657 | 1.832 | 1.56 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **4777** | 4400 | 5671 | 1.14 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.1655** | 0.1445 | 0.2488 | 1.32 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **4778** | 4401 | 5673 | 1.14 | | EF-particulate Matter | Impact on human health | disease incidence | **9.349e-05** | 6.246e-05 | 1.880e-04 | 1.75 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.903e+04** | 1.495e+04 | 3.021e+04 | 1.44 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **73.97** | 64.89 | 138.4 | 1.49 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.911e+04** | 1.504e+04 | 3.031e+04 | 1.43 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **1.505** | 1.247 | 3.371 | 1.67 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **0.7122** | 0.1311 | 19.18 | 14.1 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **10.65** | 8.561 | 26.85 | 1.77 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.232e-07** | 2.294e-07 | 8.723e-07 | 1.97 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **9.385e-08** | 8.550e-08 | 1.424e-07 | 1.3 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **3.171e-07** | 3.310e-07 | 9.636e-07 | 1.73 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.393e-05** | 1.373e-05 | 4.959e-05 | 1.92 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.301e-07** | 5.927e-07 | 1.103e-06 | 1.37 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.466e-05** | 1.464e-05 | 5.046e-05 | 1.89 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **162.3** | 61.72 | 957.4 | 4.17 | | Land use | Soil quality index | pt (soil quality index) | **6175** | 862.1 | 1.398e+04 | — | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **1.774e-05** | 1.624e-05 | 2.845e-05 | 1.32 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **4.139** | 3.442 | 9.194 | 1.63 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **7919** | 7409 | 1.251e+04 | 1.31 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.001094** | 9.444e-04 | 0.002173 | 1.52 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **632.9** | -6.815e+04 | 3.622e+04 | — | Climate change 4778 kg CO2 eq per p. Main contributors: Disposal, ventilation unit 13000 m3/h, w. rotary heat exchan… 23 %; Disposal, ventilation unit 13000 m3/h, w. circuit connected … 18 %; Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alum… 12 %; Disposal, ventilation unit 6700 m3/h, w. cross plate heat ex… 11 %; Disposal, ventilation duct, steel, zinc coated, s= 0.75mm 7 %; Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm 6 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Disposal, ventilation unit 13000 m3/h, w. rotary heat exchan… 23 %; Disposal, ventilation unit 13000 m3/h, w. circuit connected … 18 %; Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alum… 12 %; Disposal, ventilation unit 6700 m3/h, w. cross plate heat ex… 11 %; Disposal, ventilation duct, steel, zinc coated, s= 0.75mm 7 %; Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm 6 %. Most sensitive exchanges (Section 6.3): Disposal, ventilation unit 13000 m3/h, w. rotary heat exchanger [CH] (-4.6 / +5.7 %); Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger [CH] (-3.6 / +4.5 %); Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil [CH] (-2.4 / +2.9 %). ==== Independent recalculation ==== The publisher publishes no LCIA result for this dataset; the closure check of Section 7 is the recalculation test. ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Disposal, ventilation unit 13000 m3/h, w. rotary heat exchanger [CH] | 1.292 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -4.6 / +5.7 | 9.3 (Water use) | | Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger [CH] | 1 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -3.6 / +4.5 | 7.2 (Water use) | | Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil [CH] | 3665 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -2.4 / +2.9 | 10.5 (Eutrophication, freshwater) | | Disposal, ventilation unit 6700 m3/h, w. cross plate heat excanger [CH] | 0.972 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -2.2 / +2.7 | 3.8 (Water use) | | Disposal, ventilation duct, steel, zinc coated, s= 0.75mm [CH] | 1872 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -1.4 / +1.7 | 4.1 (Ionising radiation, human health) | | Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm [CH] | 837.6 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -1.1 / +1.4 | 1.4 (Climate change-Fossil) | | Disposal, ventilation duct, steel, zinc coated, s= 0.87mm [CH] | 1032 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.8 / +1.0 | 2.6 (Ionising radiation, human health) | | Disposal, ventilation system, Bürogebäude Verenastrasse, Baden, various comp. [CH] | 1 p | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.6 / +0.8 | 1.2 (Ionising radiation, human health) | | Disposal, silencer for ventilator unit 13000 m3/h, modular [CH] | 4.584 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.5 / +0.6 | 1.4 (Eutrophication marine) | | Disposal, ventilator unit 3500 m3/h, modular, w. filter, without silencer [CH] | 0.974 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.5 / +0.6 | 0.9 (Water use) | | Disposal, ventilation duct, steel, zinc coated, s= 1.25mm [CH] | 459 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.4 / +0.5 | 1.7 (Ionising radiation, human health) | | Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil [CH] | 316.5 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.3 / +0.4 | 4.5 (Eutrophication, freshwater) | | Disposal, ventilation duct, steel, zinc coated, s= 0.62mm [CH] | 425.7 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.3 / +0.4 | 0.8 (Ionising radiation, human health) | | Disposal, EI 60 fire insulation, 70mm, 120kg/m3, reinforced alumium foil [CH] | 234.7 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.3 / +0.3 | 4.7 (Eutrophication, freshwater) | | Disposal, flexible duct, aluminum/PET, DN of 125 [CH] | 251.2 m | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.3 / +0.3 | 0.3 (Human toxicity, non-cancer_inorganics) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 4778 kg CO2 eq per p (95 % interval 4401–5673). Dominant contributors: Disposal, ventilation unit 13000 m3/h, w. rotary heat exchan… 23 %; Disposal, ventilation unit 13000 m3/h, w. circuit connected … 18 %; Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alum… 12 %; Disposal, ventilation unit 6700 m3/h, w. cross plate heat ex… 11 %; Disposal, ventilation duct, steel, zinc coated, s= 0.75mm 7 %; Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm 6 %. Most sensitive: Disposal, ventilation unit 13000 m3/h, w. rotary heat exchanger [CH] (-4.6 / +5.7 %); Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger [CH] (-3.6 / +4.5 %); Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil [CH] (-2.4 / +2.9 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.9e-16 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 23/23 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 4778 in [4401, 5673] | | time period declared | **PASS** | 2014-01/2014-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].