====== Heat, residential, by transfer of geothermal heat using water source heat pump using electricity from grid — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:heat_residential_by_transfer_of_geothermal_heat_using_water_source_heat_pump_using_electricity_from_grid__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Heat, residential, by transfer of geothermal heat using water source heat pump using electricity from grid [CH], per 1 MJ. EF v3.1 climate change 0.01379 kg CO2 eq (Monte Carlo 95 % interval 0.008509–0.03251). Main contributors: Electricity, low voltage, at grid 50 %; Trifluoromethane 27 %; Heat pump 10 kW production for water source heat pump system 23 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Heat, residential, by transfer of geothermal heat using water source heat pump using electricity from grid | | Dataset UUID / graph id | ''%%952a6a9b-77fa-3f02-a42e-45e650e25faa%%'' / ''%%activity:heat_residential_by_transfer_of_geothermal_heat_using_water_source_heat_pump_using_electricity_from_grid__ch%%'' | | Reference product, unit | Heat, residential, by transfer of geothermal heat using water source heat pump using electricity from grid, 1 MJ | | Location | CH | | Time period | 2024-01/2024-01 | | Category | energy, obsolete / heat, obsolete\heat pumps, obsolete\transformation | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== This dataset represents the supply of 1 megajoule of heat in a residence, by transfer of geothermal heat in a water source heat pump. The electricity is from grid. Heat conversion efficiency [% LHV input]: 390%. LHV [MJ/kg]: 3.6. Market price [Euro/MJ]: 0.03. Distribution loss [% output]: 0%. Storage loss [% output]: 0%. Synthesis efficiency [% LHV input]: 0%. Hydrogen production efficiency [% LHV input]: 0. Grid loss [%]: 0.06. CO2 biogenic share [%]: 0%. Power [kW]: 10. Lifetime [years]: 20. Annual operation [hours]: 2100. : . For more information, refer to: Sacchi, R., Bauer, C. LCA of Power-to-X processes and applications in the residential sector. Paul Scherrer Institut, 2023. Source: Sacchi, R., Bauer, C. LCA of Power-to-X processes and applications in the residential sector. Paul Scherrer Institut, 2023. UUID: 952a6a9b-77fa-3f02-a42e-45e650e25faa This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 MJ** of Heat, residential, by transfer of geothermal heat using water source heat pump using electricity from grid (CH). All results are given per unit of the reference flow. ==== System boundary ==== — ==== Technology ==== — ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electricity, low voltage, at grid | technosphere | CH | 0.07123 | kWh | lognormal, GSD² 2.56 | — | 50.1 | ██████████ | | | Heat pump 10 kW production for water source heat pump system | technosphere | CH | 6.6140e-07 | p | lognormal, GSD² 4.25 | — | 22.6 | █████ | | | Treatment of heat pump 10 kW production for air source heat pump system | technosphere | CH | 6.6140e-07 | unit | lognormal, GSD² 2.56 | — | 0.3 | · | | | Air filter, in exhaust air valve, at plant | technosphere | RER | 1.3230e-05 | p | lognormal, GSD² 2.56 | — | 0.0 | · | | | Trifluoromethane, at plant | technosphere | GLO | 2.5130e-07 | kg | lognormal, GSD² 2.56 | — | 0.0 | · | | | 1,1-difluoroethane, HFC-152a, at plant | technosphere | US | 2.5130e-07 | kg | lognormal, GSD² 2.56 | — | 0.0 | · | | | Lubricating oil, at plant | technosphere | RER | 3.9680e-07 | kg | lognormal, GSD² 2.56 | — | 0.0 | · | | | Transport, freight, lorry, 16t-32t gross weight, fleet average | technosphere | CH | 3.8230e-08 | tkm | lognormal, GSD² 2.21 | — | 0.0 | · | | | Transport, freight, rail, electricity with shunting | technosphere | CH | 3.1470e-07 | tkm | lognormal, GSD² 2.21 | — | 0.0 | · | | | Trifluoromethane | elementary | air/Unknown | 2.5130e-07 | kg | lognormal, GSD² 2.79 | — | 26.6 | █████ | | | 1,1-Difluoroethane | elementary | air/Unknown | 2.5130e-07 | kg | lognormal, GSD² 2.79 | — | 0.3 | · | | | Energy, Geothermal, Converted | elementary | natural resource | 1 | MJ | lognormal, GSD² 2.56 | — | 0.0 | · | | ==== Data quality ==== 0 of 12 direct exchanges carry a declared pedigree, 12 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Romain Sacchi (PSI); data entry: Romain Sacchi (PSI); validation (proof reading): Romain Sacchi (PSI) | | sampling procedure | Sampling procedure: Literature data | | validation details | Proof reading validation: Passed, Other validation: none, Validator: Rolf Frischknecht, Telephone: 0041 44 940 61 91, E-mail: frischknecht@treeze.ch, Company: treeze, Country: CH | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 MJ. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **3.377e-05** | 1.681e-05 | 1.165e-04 | 2.63 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.924e-04** | 8.450e-05 | 5.300e-04 | 2.6 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.01358** | 0.008419 | 0.03214 | 1.97 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2.322e-05** | 9.252e-06 | 6.224e-05 | 2.61 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.01379** | 0.008509 | 0.03251 | 1.97 | | EF-particulate Matter | Impact on human health | disease incidence | **4.339e-10** | 2.265e-10 | 1.286e-09 | 2.38 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.03998** | 0.02328 | 0.1635 | 2.61 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **7.742e-04** | 4.473e-04 | 0.003304 | 2.74 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.04076** | 0.02389 | 0.1658 | 2.6 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **8.107e-06** | 4.407e-06 | 2.483e-05 | 2.32 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **1.024e-05** | 4.698e-06 | 6.688e-05 | 3.79 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **6.081e-05** | 3.333e-05 | 1.876e-04 | 2.37 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.919e-12** | 2.295e-12 | 2.140e-11 | 3.06 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.540e-12** | 1.722e-12 | 9.644e-12 | 2.35 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **7.459e-12** | 4.497e-12 | 2.823e-11 | 2.56 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.835e-10** | 1.588e-10 | 1.718e-09 | 3.33 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.610e-11** | 7.045e-12 | 6.813e-11 | 3.12 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.996e-10** | 1.679e-10 | 1.789e-09 | 3.29 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.05182** | 0.01363 | 0.3089 | 5.27 | | Land use | Soil quality index | pt (soil quality index) | **0.1143** | 0.05228 | 0.3172 | 2.51 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **2.481e-09** | 1.083e-09 | 8.834e-09 | 2.92 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **2.335e-05** | 1.340e-05 | 7.700e-05 | 2.4 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.5679** | 0.2758 | 1.46 | 2.36 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **1.185e-07** | 5.487e-08 | 4.263e-07 | 2.82 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.004765** | -21.09 | 10.97 | — | Climate change 0.01379 kg CO2 eq per MJ. Main contributors: Electricity, low voltage, at grid 50 %; Trifluoromethane 27 %; Heat pump 10 kW production for water source heat pump system 23 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electricity, low voltage, at grid 50 %; Trifluoromethane 27 %; Heat pump 10 kW production for water source heat pump system 23 %. Most sensitive exchanges (Section 6.3): Electricity, low voltage, at grid [CH] (-30.2 / +76.0 %); Heat pump 10 kW production for water source heat pump system [CH] (-17.1 / +70.8 %); Trifluoromethane [air/Unknown] (-16.9 / +46.0 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 3.377e-05 | 3.648e-05 | 0.926 | | Climate change-Biogenic | 1.924e-04 | 1.924e-04 | 1.000 | | Climate change-Fossil | 0.01358 | 0.01358 | 1.000 | | Climate change-Land use and land use change | 2.322e-05 | 2.322e-05 | 1.000 | | Climate change | 0.01379 | 0.01379 | 1.000 | | EF-particulate Matter | 4.339e-10 | 4.339e-10 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.03998 | 0.04192 | 0.954 | | Ecotoxicity, freshwater_organics | 7.742e-04 | 7.608e-04 | 1.018 | | Ecotoxicity, freshwater | 0.04076 | 0.04267 | 0.955 | | Eutrophication marine | 8.107e-06 | 8.084e-06 | 1.003 | | Eutrophication, freshwater | 1.024e-05 | 1.024e-05 | 1.000 | | Eutrophication, terrestrial | 6.081e-05 | 6.759e-05 | 0.900 | | Human toxicity, cancer_inorganics | 3.919e-12 | 3.821e-12 | 1.026 | | Human toxicity, cancer_organics | 3.540e-12 | 3.540e-12 | 1.000 | | Human toxicity, cancer | 7.459e-12 | 7.361e-12 | 1.013 | | Human toxicity, non-cancer_inorganics | 2.835e-10 | 2.787e-10 | 1.017 | | Human toxicity, non-cancer_organics | 1.610e-11 | 1.610e-11 | 1.000 | | Human toxicity, non-cancer | 2.996e-10 | 2.948e-10 | 1.017 | | Ionising radiation, human health | 0.05182 | 0.05182 | 1.000 | | Land use | 0.1143 | 0.09244 | 1.237 | | Ozone depletion | 2.481e-09 | 2.481e-09 | 1.000 | | Photochemical ozone formation - human health | 2.335e-05 | 2.335e-05 | 1.000 | | Resource use, fossils | 0.5679 | 0.5679 | 1.000 | | Resource use, minerals and metals | 1.185e-07 | 1.176e-07 | 1.008 | | Water use | 0.004765 | 0.005228 | 0.911 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.01378 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 46.59 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Electricity, low voltage, at grid [CH] | 0.07123 kWh | ×0.397 / ×2.52 | lognormal, GSD² 2.56 | -30.2 / +76.0 | 149.8 (Ionising radiation, human health) | | Heat pump 10 kW production for water source heat pump system [CH] | 6.614e-07 p | ×0.242 / ×4.13 | lognormal, GSD² 4.25 | -17.1 / +70.8 | 192.3 (Human toxicity, non-cancer_inorganics) | | Trifluoromethane [air/Unknown] | 2.513e-07 kg | ×0.366 / ×2.73 | lognormal, GSD² 2.79 | -16.9 / +46.0 | 46.7 (Climate change-Fossil) | | Treatment of heat pump 10 kW production for air source heat pump system [CH] | 6.614e-07 unit | ×0.397 / ×2.52 | lognormal, GSD² 2.56 | -0.2 / +0.5 | 1.8 (Ecotoxicity, freshwater_inorganics) | | 1,1-Difluoroethane [air/Unknown] | 2.513e-07 kg | ×0.366 / ×2.73 | lognormal, GSD² 2.79 | -0.2 / +0.5 | 0.5 (Climate change-Fossil) | | Air filter, in exhaust air valve, at plant [RER] | 1.323e-05 p | ×0.397 / ×2.52 | lognormal, GSD² 2.56 | -0.0 / +0.0 | 0.1 (Ecotoxicity, freshwater_organics) | | Trifluoromethane, at plant [GLO] | 2.513e-07 kg | ×0.397 / ×2.52 | lognormal, GSD² 2.56 | -0.0 / +0.0 | 19.7 (Ozone depletion) | | 1,1-difluoroethane, HFC-152a, at plant [US] | 2.513e-07 kg | ×0.397 / ×2.52 | lognormal, GSD² 2.56 | -0.0 / +0.0 | 0.0 (Acidification) | | Lubricating oil, at plant [RER] | 3.968e-07 kg | ×0.397 / ×2.52 | lognormal, GSD² 2.56 | -0.0 / +0.0 | 0.1 (Ecotoxicity, freshwater_organics) | | Transport, freight, lorry, 16t-32t gross weight, fleet average [CH] | 3.823e-08 tkm | ×0.46 / ×2.17 | lognormal, GSD² 2.21 | -0.0 / +0.0 | 0.0 (Photochemical ozone formation - human health) | | Transport, freight, rail, electricity with shunting [CH] | 3.147e-07 tkm | ×0.46 / ×2.17 | lognormal, GSD² 2.21 | -0.0 / +0.0 | 0.0 (Land use) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.01379 kg CO2 eq per MJ (95 % interval 0.008509–0.03251). Dominant contributors: Electricity, low voltage, at grid 50 %; Trifluoromethane 27 %; Heat pump 10 kW production for water source heat pump system 23 %. Most sensitive: Electricity, low voltage, at grid [CH] (-30.2 / +76.0 %); Heat pump 10 kW production for water source heat pump system [CH] (-17.1 / +70.8 %); Trifluoromethane [air/Unknown] (-16.9 / +46.0 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 MJ | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.5e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 12/12 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.01379 in [0.008509, 0.03251] | | time period declared | **PASS** | 2024-01/2024-01 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Report — //source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].