====== Disposal of heat dissipation system, office building Fribourg — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:disposal_of_heat_dissipation_system_office_building_fribourg__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Disposal of heat dissipation system, office building Fribourg [CH], per 1 m2. EF v3.1 climate change 0.1341 kg CO2 eq (Monte Carlo 95 % interval 0.1098–0.1652). Main contributors: Disposal, floor heating tube 81 %; Disposal, various components for heating system 15 %; Disposal, convector radiator 4 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Disposal of heat dissipation system, office building Fribourg | | Dataset UUID / graph id | ''%%9667f125-16eb-4555-bc6a-d05bc20e4915%%'' / ''%%activity:disposal_of_heat_dissipation_system_office_building_fribourg__ch%%'' | | Reference product, unit | Disposal of heat dissipation system, office building Fribourg, 1 m2 | | Location | CH — Specific to the technology mix encountered in sorting plants in Switzerland. | | Time period | 1994-01/2008-12 | | Category | waste management / building demolition | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Disposal of components for the heat dissipation system; UUID: 9667f125-16eb-4555-bc6a-d05bc20e4915 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 m2** of Disposal of heat dissipation system, office building Fribourg (CH). All results are given per unit of the reference flow. ==== System boundary ==== Transport to dismantling facilities, machines for handling in sorting plant, electricity demand for sorting plant, final disposal of waste material. Cut-off to recycling for metals. ==== Technology ==== Disposal to a sorting plant assumed. Metal pieces, copper in cables and electronic devices are recycled, plastic parts are incinerated, inert wastes are landfilled. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Disposal, floor heating tube | technosphere | CH | 0.3376 | m | lognormal, GSD² 1.07 | (1,1,1,1,1,1) | 80.9 | ████████████████ | | | Disposal, various components for heating system | technosphere | CH | 0.05048 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,1) | 15.0 | ███ | | | Disposal, convector radiator | technosphere | CH | 0.942 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,1) | 4.1 | █ | | ==== Data quality ==== 3 of 3 direct exchanges carry a declared pedigree, 3 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 1.0 · completeness 1.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 1.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Matthias Klingler; data entry: Matthias Klingler; validation (proof reading): Matthias Klingler | | extrapolations | none | | sampling procedure | Waste-specific calculation based on input data from call of bids for a heating system of a specific building. | | production volume | na | | uncertainty adjustments | none | | time period comment | Amount of material investigated in 2013. Disposal technology mix as used in late 1990ies | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 m2. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **1.422e-05** | 1.162e-05 | 2.329e-05 | 1.42 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.160e-05** | 8.720e-06 | 2.066e-05 | 1.56 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.1341** | 0.1098 | 0.1652 | 1.24 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.724e-06** | 1.416e-06 | 2.705e-06 | 1.39 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.1341** | 0.1098 | 0.1652 | 1.24 | | EF-particulate Matter | Impact on human health | disease incidence | **1.887e-10** | 1.727e-10 | 2.837e-10 | 1.28 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.0578** | 0.0482 | 0.1328 | 1.68 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **8.604e-04** | 6.963e-04 | 0.001655 | 1.56 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.05866** | 0.04927 | 0.1336 | 1.67 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **1.435e-05** | 9.936e-06 | 2.565e-05 | 1.65 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **6.804e-07** | 5.089e-07 | 2.822e-06 | 2.43 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **1.177e-04** | 8.111e-05 | 2.129e-04 | 1.65 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **6.105e-12** | 3.358e-12 | 3.899e-11 | 3.71 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **6.384e-13** | 5.828e-13 | 9.980e-13 | 1.32 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **6.743e-12** | 4.146e-12 | 3.972e-11 | 3.38 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.090e-10** | 1.190e-10 | 1.541e-09 | 3.71 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.868e-12** | 3.357e-12 | 5.640e-12 | 1.3 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.129e-10** | 1.234e-10 | 1.545e-09 | 3.65 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.002184** | 8.075e-04 | 0.01291 | 4.2 | | Land use | Soil quality index | pt (soil quality index) | **0.07057** | 0.02215 | 0.1303 | — | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **2.090e-10** | 1.712e-10 | 3.203e-10 | 1.37 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **4.499e-05** | 3.335e-05 | 7.596e-05 | 1.54 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.08783** | 0.07571 | 0.1302 | 1.3 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **1.258e-08** | 1.028e-08 | 2.414e-08 | 1.57 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.001881** | -0.9113 | 0.4569 | — | Climate change 0.1341 kg CO2 eq per m2. Main contributors: Disposal, floor heating tube 81 %; Disposal, various components for heating system 15 %; Disposal, convector radiator 4 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Disposal, floor heating tube 81 %; Disposal, various components for heating system 15 %; Disposal, convector radiator 4 %. Most sensitive exchanges (Section 6.3): Disposal, floor heating tube [CH] (-5.3 / +5.7 %); Disposal, various components for heating system [CH] (-1.0 / +1.1 %); Disposal, convector radiator [CH] (-0.3 / +0.3 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 1.422e-05 | 3.103e-05 | 0.458 | | Climate change-Biogenic | 1.160e-05 | 1.160e-05 | 1.000 | | Climate change-Fossil | 0.1341 | 0.1341 | 1.000 | | Climate change-Land use and land use change | 1.724e-06 | 1.724e-06 | 1.000 | | Climate change | 0.1341 | 0.1341 | 1.000 | | EF-particulate Matter | 1.887e-10 | 1.887e-10 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.0578 | 0.0596 | 0.970 | | Ecotoxicity, freshwater_organics | 8.604e-04 | 8.577e-04 | 1.003 | | Ecotoxicity, freshwater | 0.05866 | 0.05997 | 0.978 | | Eutrophication marine | 1.435e-05 | 1.435e-05 | 1.000 | | Eutrophication, freshwater | 6.804e-07 | 6.804e-07 | 1.000 | | Eutrophication, terrestrial | 1.177e-04 | 1.494e-04 | 0.788 | | Human toxicity, cancer_inorganics | 6.105e-12 | 6.097e-12 | 1.001 | | Human toxicity, cancer_organics | 6.384e-13 | 6.384e-13 | 1.000 | | Human toxicity, cancer | 6.743e-12 | 6.735e-12 | 1.001 | | Human toxicity, non-cancer_inorganics | 2.090e-10 | 2.052e-10 | 1.019 | | Human toxicity, non-cancer_organics | 3.868e-12 | 3.867e-12 | 1.000 | | Human toxicity, non-cancer | 2.129e-10 | 2.091e-10 | 1.018 | | Ionising radiation, human health | 0.002184 | 0.002184 | 1.000 | | Land use | 0.07057 | 0.04291 | 1.645 | | Ozone depletion | 2.090e-10 | 2.090e-10 | 1.000 | | Photochemical ozone formation - human health | 4.499e-05 | 4.499e-05 | 1.000 | | Resource use, fossils | 0.08783 | 0.08783 | 1.000 | | Resource use, minerals and metals | 1.258e-08 | 1.171e-08 | 1.074 | | Water use | 0.001881 | 0.001929 | 0.975 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.1341 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 948.4 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Disposal, floor heating tube [CH] | 0.3376 m | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -5.3 / +5.7 | 5.7 (Climate change-Fossil) | | Disposal, various components for heating system [CH] | 0.05048 kg | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -1.0 / +1.1 | 2.4 (Water use) | | Disposal, convector radiator [CH] | 0.942 kg | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.3 / +0.3 | 6.3 (Ionising radiation, human health) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.1341 kg CO2 eq per m2 (95 % interval 0.1098–0.1652). Dominant contributors: Disposal, floor heating tube 81 %; Disposal, various components for heating system 15 %; Disposal, convector radiator 4 %. Most sensitive: Disposal, floor heating tube [CH] (-5.3 / +5.7 %); Disposal, various components for heating system [CH] (-1.0 / +1.1 %); Disposal, convector radiator [CH] (-0.3 / +0.3 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 m2 | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.0e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 3/3 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.1341 in [0.1098, 0.1652] | | time period declared | **PASS** | 1994-01/2008-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].